DVM. Digital Power Meter DVM. Features. Technical Data. Typical Application Diagram. Case Dimensions. Ordering Information. Front. Panel Cutout.

Similar documents
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Power Meter Series 700

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Applications. diris_826_a_1_gb_cat

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Energy Management Power Analyzer Type WM14-96 Basic Version

M2M The measure of efficiency

A project to optimise quality and energy efficiency must include metering

Quick Connect. quick - simple - efficient.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

T Substation Maintenance and Commissioning Test Equipment

Energy Management Energy Meter Type EM23 DIN

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Eaton s E-Series protective relay family

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Multilin EPM GE Grid Solutions. High Accuracy Power & Energy Measurement. Monitoring & Metering. Advanced Communications.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Voltage Regulator SPAU 341 C. Product Guide

Metering Devices IQ Analyzer 6400/6600 Series

Metering devices. Features The high-quality measuring technology of the device facilitates 4-quadrant power metering. In this way, metering

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Digital single-phase Energy-meters. Direct till 32 A 1 module DIN page 5. Direct till 45 A 1 module DIN page 6. Direct till 80 A 2 modules DIN page 7

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

EARTH LEAKAGE PROTECTION: CONTENTS

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Panel Meters and Controllers Modular Panel Meter Type EDM 35

EM-PQ 1500 Power Quality Monitor. Operating Manual

One Meter Works for Both Energy Saving and Power Quality Surveillance

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

March 15th 2005 EI Solutions - Submetering 1

PCS0100en Persy Control Services B.V. Netherlands

DS 600. A contact free flux gate based current measurement sensor 600A rms

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Waveguide Access Point WGA631. Product Guide

3-phase, bidirectional energy meter

Three-phase monitoring relay CM-PFE

FREJA 300 Relay Testing System

RM4TG20 three-phase network control relay RM4-T - range V

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

TX OPEN RS232/485 module

Installation manual. Generator Paralleling Controller GPC multi-line C

NC-12 Modbus Application

Counter for Energy. We make energy measurable and secure your future.

Communicate and view data from meters with one simple device

Application/Connection Examples

Elster Metering Systems. EC Directive 2004/22/EC

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

DIRIS A40/A41 RS485 JBUS/MODBUS. Operating instructions F GB D I NL E P

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

OZW30. Central Unit SYNERGYR

Digital Clamp-on DMMs with uncompromising performance

Electrical Measuring Instruments

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

SINEAX U553 Transducer for AC Voltage

IntesisBox Modbus Server Fidelio IP

San Diego Community College District

PowerLogic power-monitoring units. PM5350 power meter. Technical data sheet

Main catalog. Electricity meters For modular enclosures and DIN rail

Electronic overload relay EF19 and EF45

Polyphase kwh Electricity Meter

How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Power Meter Series 800

1. INTRODUCTION FEATURES 2. PROGRAMMING

Maximum Demand Control

Rack mounted telephone- and leased line modem for industrial applications

UMG 96L. Universal Measuring Device. Operating Instructions. Brief instructions see last page

ADM1TE 5/30A DIN rail single phase two wire energy meter

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Panorama Electricity meters For reliable values of energy consumption

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Digital Pressure Measuring Instrument MDR480

Managing. Energy management and power analysis

CompactLogix Power Supplies Specifications

Uninterruptible Power Supply

Measuring transducers for all electrical AC-variables

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Telephone- and leased line modem for industrial applications TD-36

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

E-STOP relays, safety gate monitors

Contents. Energy saving screen saver. Harmonics measurings up the 15 th or 50 th. Relays with OR option. 0.5% accuracy in voltage and current

E-Series protective relay family

Transcription:

Digital Power Meter DVM Built-in selector switch Easy-to-read, 14.2mm digit display DIN size casing Technical Data Auxiliary supply : 198 ~ 265 V AC : 94 ~ 127 V AC VA rating : 3 VA Input frequency : 47 ~ 66 Hz Maximum input voltage : 500 Vrms Approximate weight : 0.6 kg Typical Application Diagram DVM360 Series DVM100 Series L N N 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 7 8 9 10 11 12 Aux Supply AC 240 V Aux Supply AC 240 V 91.5 mm 87 mm 91.0 ± 0.5 mm Panel Cutout 91.0 ± 0.5 mm DVM DVM360-240A DVM100-240A DVM360-110A DVM100-110A

DAM Typical Application Diagram 1 DAM330 / 3000 Series 2 3 4 5 7 8 9 10 11 12 Aux Supply AC 240 V 6 Built-in selector switch Easy-to-read, 14.2mm digit display DIN size casing Wide selection of current transformer (CT) ratio Technical Data Auxiliary supply : 198 ~ 265 V AC : 94 ~ 127 V AC VA rating : 3 VA Input frequency : 47 ~ 66 Hz Maximum input : 6 A continuous Ammeter CT ratio :.../5 A Class : 1.0 Approximate weight : 0.7 kg L N 91.5 mm 87 mm 1 DAM100 / 1000 Series 2 3 4 5 7 8 9 10 11 12 Aux Supply AC 240 V 6 91.0 ± 0.5 mm Panel Cutout 91.0 ± 0.5 mm Digital Power Meter DAM

Digital Power Meter DAM For primary current from 60 A to 500 A DAM 330 - XXXX DAM 100 - XXXX Order number Model DAM 330 & DAM 100 ORDER NUMBER *CT RATIO 0060 60 / 5 A 0100 100 / 5 A 0150 150 / 5 A 0200 0250 0300 0400 0500 200 / 5 A 250 / 5 A 300 / 5 A 400 / 5 A 500 / 5 A Example: Model DAM 330-0060 for digital ammeter with CT ratio 60 / 5 A. *CT : / SERIES DAM330 DAM3000 DAM100 DAM1000 Current Transformer For other CT ratio, please contact the manufacturer. DAM330 - xxxx - 240A DAM100 - xxxx - 240A DAM330 - xxxx - 110A DAM100 - xxxx - 110A DAM3000 - xxxx - 240A DAM1000 - xxxx - 240A DAM3000 - xxxx - 110A DAM1000 - xxxx - 110A WITH SELECTOR WITHOUT SELECTOR For primary current from 600 A to 5000 A DAM 3000 - XXXX DAM 1000 - XXXX DISPLAY FORMAT 600 Order number Model DAM3000 & DAM1000 ORDER NUMBER *CT RATIO 600 / 5 A 800 800 / 5 A 1000 1000 / 5 A 1200 1500 1600 2000 2400 UNIT A A A A 1200 / 5 A 1500 / 5 A 1600 / 5 A 2000 / 5 A 2400 / 5 A 2500 2500 / 5 A 3000 3000 / 5 A 3200 3200 / 5 A 3500 3500 / 5 A 4000 4000 / 5 A 4500 4500 / 5 A 5000 5000 / 5 A

DPM680 Measurement Parameters: Phase & Line Voltages (L-N) Phase Current & Neutral Current Bidirectional kw, kvar & kva Bidirectional kwh, kvarh & kvah Frequency Total & Displacement Power Factor Voltage Total Harmonic Distortion Current Total Harmonic Distortion Thermal Current Demand Power Demand Current Sequence Components Voltage Sequence Components Digital Power Meter TFT Colour LCD Display Serial RS-485 Modbus RTU Modbus TCP/IP Built-in Webserver Voltage & Current Waveform Display Voltage & Current Harmonics Display Technical Data WIRING SYSTEMS 3-phase 4-wire system 3-phase 3-wire system CURRENT MEASUREMENT (TRMS) Nominal current : 5 A Min. measurement : 5 ma : 0.2% of full scale Burden : < 0.05 VA at 5 A Measurement range : 10 A Pulsed withstand : 100 A for 1 sec CT primary : 5 ~ 50,000 A VOLTAGE MEASUREMENT (TRMS) Nominal phase voltage : 0 ~ 300 V AC Minimum measurement : 10 V : 0.2% at full scale Phase voltage via VT : 60 ~ 50,000 V POWER MEASUREMENT Real power, apparent power, reactive power : 0.5% POWER FACTOR MEASUREMENT Total and displacement power factor : 0.5% POWER & THERMAL CURRENT DEMAND Interval : 1 ~ 30 mins VOLTAGE AND CURRENT SEQUENCE COMPONENTS Positive, negative and zero sequence FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 Hz : 0.2% ENERGY MEASUREMENT ACCURACY Active : IEC 62053-22 class 0.5 Reactive : IEC 62053-23 class 2 HARMONICS DISPLAY Fundamental up to 32nd order VOLTAGE & CURRENT WAVEFORM DISPLAY Simultaneous 3-phase voltage or current waveforms COMMUNICATION Interface : Modbus RTU : Isolated RS485 Interface Interface : Modbus TCP/IP : Ethernet 10M/100M BaseT : HTTP Server : Ethernet 10M/100M BaseT AUXILIARY POWER SUPPLY AC voltage : 90 ~ 415 V AC Frequency : 50 / 60 Hz DC voltage : 100 ~ 300 V DC Power consumption : 3W typical Sustained overload : 500 V AC ENVIRONMENTAL CONDITIONS Overvoltage category : IV Pollution degree : 2 Operating temperature : -10 C ~ +55 C Storage temperature : -20 C ~ +70 C Humidity : 0 95%, non condensing MECHANICAL Mounting : according to DIN 43700 / ANSI C39.1 Dimension (mm) : 96(w) x 96(h) x 100(d) Enclosure protection : IP63 at the panel IP20 at the body Approximate weight : 0.5 kg DPM 680

Digital Power Meter Typical Application Diagrams 3-PHASE 4-WIRE SYSTEM : 4 CTs, Direct V Input AUX 100~300 V DC l2 Ethernet 3-PHASE 4-WIRE SYSTEM : 3 CTs, Direct V Input AUX 100~300 V DC l2 Ethernet 90 mm 3-PHASE 3-WIRE SYSTEM : 3 CTs, 3 VTs 3-PHASE 3-WIRE SYSTEM : 3 CTs, Direct V Input 83 mm AUX 100~300 V DC l2 Ethernet AUX 100~300 V DC l2 Ethernet 17 mm Rear 100 mm 86 mm Test Standards Cut-Out Recommendations IEC 61010-1 Safety requirements. IEC 61326-1 EMC requirements. 91±0.5mm 91±0.5mm 101.6±0.5mm DPM 680 DPM 680-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC

Technical Data DISPLAY TYPE LCD display MEASUREMENTS 3-phase 4-wire system 3-phase 3-wire system CURRENT MEASUREMENT (TRMS) CT primary : 5 ~ 8000 A CT secondary : 5 A Minimum measurement : 5 ma : 0.5% from 1A to 6 A (secondary) Burden : < 0.05 VA at 5 A Sustained overload : 6 A VOLTAGE MEASUREMENT (TRMS) Nominal phase voltage : 20 ~ 300 V AC Minimum measurement : 10 V : 0.5% at full scale Phase voltage via VT : 60 ~ 33,000 V DPM380 DPM380B POWER MEASUREMENT Real power, apparent power, reactive power measurement Measuring updating period : 1 s : 1.0% ACTIVE POWER DEMAND Interval : 1 ~ 30 mins POWER FACTOR MEASUREMENT Total and displacement power factor : 1.0% FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 Hz Measurement updating period : 1s : 0.5% ENERGY ACCURACY Active (according to IEC 62053-21) : class 1 Reactive (according to IEC 62053-23) : class 2 LCD display with back lighting communication (for DPM380 only) MEASUREMENT PARAMETERS: Phase Voltage (L-N) Line Voltage (L-L) Phase Current and Neutral Current Bidirectional kw (per phase & total) Bidirectional kvar (per phase & total) Bidirectional kva (per phase & total) Frequency Power Factor (per phase & total) Energy (+ and - ) for kwh, kvarh and kvah THD Phase Voltage ( L-N ) THD Phase Current Active Power Demand AUXILIARY POWER SUPPLY AC voltage : 90 ~ 415 V AC Frequency : 50 / 60 Hz DC voltage : 100 ~ 300 V DC Power consumption : <3 VA COMMUNICATION Hardware interface : Isolated RS485 : Baud rate : 2400, 4800, 9600, 19200, 38400 ENVIRONMENTAL CONDITIONS Operating temperature : -10 C ~ +55 C Storage temperature : -20 C ~ +70 C Humidity : 0 95%, non condensing MECHANICAL Mounting Dimension (mm) Approximate weight : Panel mounting : 96(w) x 96(h) x 100(d) : 0.5 kg Digital Power Meter DPM 380 / 380B

3-PHASE 4-WIRE SYSTEM WITH 4 CTs CONNECTION AUX 100~300 V DC l2 * For DPM380 only + 90 mm Digital Power Meter Typical Application Diagram 83 mm 10 0m m 17 mm 3-PHASE 4-WIRE SYSTEM WITH 3 CTs CONNECTION Rear ea AUX 100~300 V DC 86 mm 86 mm l2 * For DPM380 only - Cut-Out Recommendations + 91±0.5mm Electromagnetic Compatibility (EMC) 91±0.5mm DPM 380 / 380B Part 6-2: Generic Standards IEC61000-6-2 Immunity for industrial environments. Part 6-4: Generic Standards IEC61000-6-4 Emission standard for industrial environments. DPM 380-415AD DPM 380B-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC, with Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC 101.6±0.5mm

Technical Data DISPLAY TYPE LCD display MEASUREMENTS 3-phase 4-wire system CURRENT MEASUREMENT (TRMS) CT primary : 5 ~ 8000 A CT secondary : 5 A Minimum measurement : 10 ma : 0.5% from 1A to 6 A (secondary) Burden : < 0.03 VA at 5 A Sustained overload : 6 A VOLTAGE MEASUREMENT (TRMS) Nominal phase voltage : 70 ~ 300 V AC Minimum measurement : 10 V : 0.5% at full scale DM38 POWER MEASUREMENT Real power, apparent power, reactive power measurement Measuring updating period : 1 s : 1.0% POWER FACTOR MEASUREMENT Total and displacement power factor : 1.0% LCD display with back lighting communication DIN rail type MEASUREMENT PARAMETERS: Phase Voltage ( L-N ) Line Voltage ( L-L ) Phase Current Bidirectional kw (per phase & total) Bidirectional kvar (per phase & total) Bidirectional kva (per phase & total) Frequency FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 Hz Measurement updating period : 1s : 0.5% ENERGY ACCURACY Active (according to IEC 62053-21) : class 1 Reactive (according to IEC 62053-23) : class 2 Power Factor (per phase & total) Energy (+ and - ) for kwh, kvarh and kvah THD Phase Voltage ( L-N ) THD Phase Current POWER SUPPLY Self supplied Frequency Power consumption : 100 ~ 240 V AC : 50 / 60 Hz : <3 VA COMMUNICATION Hardware interface : Isolated RS485 : Baud rate : 2400, 4800, 9600, 19200, 38400 ENVIRONMENTAL CONDITIONS Operating temperature : -10 C ~ +55 C Storage temperature : -20 C ~ +70 C Humidity : 0 95%, non condensing MECHANICAL Mounting Dimension (mm) Approximate weight : DIN rail : 65(w) x 85(h) x 50(d) : 0.3 kg Digital Power Meter DM 38

Digital Power Meter Typical Application Diagram DM 38 CONNECTION DIAGRAM 1 2 3 4 5 6 I1 I2 I3 7 8 9 10 11 - + 120 Ohm 12 13 14 15 16 17 18 19 20 21 22! P1 P2 X DM38 NOTE: Current transformer secondary terminal MUST NOT be earthed. Electromagnetic Compatibility (EMC) Part 6-2: Generic Standards IEC61000-6-2 Immunity for industrial environments. Part 6-4: Generic Standards IEC61000-6-4 Emission standard for industrial environments. 65 mm 45.5 mm 85 mm DM 38-240A Self Powered 100~240 V AC 71 mm 50 mm DM 38 15.5 mm