RE 92730/ Compact Unit A10CO

Similar documents
A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Variable Displacement Pump AA10VSO

Series TMM Axial Piston Motor. Technical Information

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Variable Displacement Pump A7VO

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

Variable Displacement Pump A10VSO for open circuits

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Axial Piston Variable Pump A10VSO

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Fixed displacement vane pumps

Axial Piston Fixed Displacement Motor A2FM

PUMP AND MOTOR DIVISION

Rexroth Hydraulic Pump A10VO Series User Manual

Series PVP Variable Volume Piston Pumps

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Radial piston pumps type R and RG

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

Axial Piston Variable Pump KVA

Unit 24: Applications of Pneumatics and Hydraulics

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

Chapter 5: Flow Valves

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

Rickmeier Solutions. Gear pumps for superior Lubrication


Internal gear pump PGF Series 2X and 3X

Unit 24: Applications of Pneumatics and Hydraulics

Hydraulic Control Solutions

DuraForce HPV Variable Pumps for Closed Loop Operation

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Pressure reducing valve, direct operated, Type ZDR 6 D

Axial Piston Variable Motor A6VM

Pressure relief valves Size 6

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

Table of Contents. M Series Variable Displacement Piston Pumps

HMC Series Dual Displacement Staffa Motor

Flow divider (flow distributor), type TQ

Dual Path Mobile Pump

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

Fixed Displacement Pump A2FO

PVM Piston Pumps Service Manual

Pressure Relief Valves SPV, SPVF

Line rupture protection valves type LB

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

Vickers PVM Piston Pumps

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Pressure and flow control system

PLQE. The base of the economy gearboxes with square output flange. Economy Line. Formerly PLE

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

Eco130 Series. Medium Pressure Filters Max l/min. 30 bar. Modular system for industrial applications. Applications: Contact Information:

Hydraulic multidisc Brake H420

Vickers. Piston Pumps

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Axial Piston Variable Pump A10VSO

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

Transfer Gear Pumps KF

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

15/40/80CN Series Medium Pressure Filters

PVH131/141 Variable Displacement Piston Pump - 11 Design

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

High Pressure Gear Motors KM 1

220 Series Piston Pump Typical Applications Features and Benefits

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Hydraulic control unit series


HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Chapter 6: Check Valves

2/2 and 3/2 Way Size 6 Seat Valves

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

ZF W325 Vertical offset, direct mount marine transmission.

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

SOLENOID VALVES 3-4 WAY

Specifications for Volkswagen Industrial Engine

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series

3/2- and 2/2-way cartridge valve type BVE

MACHINE TOOL SPINDLE DRIVE GEARBOXES MSD RAM-MSD

Series 40 Axial Piston Motors. Technical Information

Tool Turrets and Tool Discs

2-way flow control valve Type 2FRM 6

GoTo Europe Focused Delivery Program. Product overview industrial and mobile hydraulics

KDG3V-5/7/8, 10 Series

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Transcription:

Compact Unit ACO 52-series, axial piston in swashplate design RE 92730/01.98 NG 45 Nominal pressure 250 bar Peak pressure 315 bar The AVO compact unit was designed specifically for mobile applications where it is necessary to boost the A-inlet with a full flow boost pump, i.e. hydraulic systems for agricultural tractors, running on oil from the transmission (common oil systems). This enables also an effective filtration in the A-inlet line. A boost pump with a some what larger displacement can provide extra oil for lubricating purposes. Central hydraulic unit for mounting to transmission p.t.o. in mobile applications Integrated boost pump AVO main pump with controller Filter mounting capability Integrated pressure relief valves Reduced pipework Compact design Transmission lubrication port Measurement or monitoring ports Integrated case drain port inside pilot diameter 1/8

Type key Hydraulic fluid Mineral oil (without prefix) Axial-piston pump Compact unit in swashplate design, adjustable Nominal pressure 250 bar, peak pressure 315 bar Operating mode Pump, open-circuit Size Displacement volume V g max (cm 3 ) AC O 45 / 52 V C H00 2 AC O 45 Control options Pressure controller DR DR Pressure controller, remote controlled DRG DRG Pressure and flow controller DFR DFR DFR 1 DFR1 without connection from to tank Series } see RE 92703 52 Direction of rotation Viewing drive shaft cw anti-cw R L Seals FPM (fluororubber to DIN ISO 1629) Shaft end Spline shaft SAE, shortened 1" Spline shaft SAE, shortened (higher through-drive torque) 1" Spline shaft SAE, shortened 7/8" Mounting flange SAE 2-hole V S R U C Port for service lines Pressure port B metric thread side ports 07 Suction port S Pressure port B Suction port S SAE on opposite sides, metric fixing thread 12 Boost pump with integrated boost pump H00 Valves with integrated pressure relief valves 2 Filtration Filter installed in boost circuit F without filter, mounting option only D = available = in preparation 2/8

Hydraulic fluid Please refer to our catalogue sheets RE 90220 (mineral oil) and RE 90221 (environmentally friendly hydraulic fluids) for detailed information on selecting hydraulic fluids and on service conditions before the project planning stage. Operation with environmentally friendly hydraulic fluids may result in modifications to the technical specifications; please consult us if necessary. Service viscosity range We recommend selecting the service viscosity (at operating temperature) in the range of ν opt = opt. opt. service viscosity 16...36 mm 2 /s for optimum efficiency and useful life, in relation to tank temperature (open circuit). Limiting viscosity range Service limits are set at the following values: ν min = mm 2 /s briefly at max. permissible leakage oil temperature of 90 C. ν max = 00 mm 2 /s briefly on cold start. Temperature range (see selection chart) t min = 25 C t max = +90 C Comment on selecting hydraulic fluid To select the correct hydraulic fluid it is necessary to know the operating temperature in the tank (open circuit) in relation to ambient temperature. The hydraulic fluid must be selected in such a way that service viscosity lies within the optimum range (ν opt ) for the operating temperature span, see shaded area in the chart. We recommend selecting the next higher viscosity class in each case. Example: An ambient temperature of C will produce an operating temperature in the tank of 60 C. Given the optimum service viscosity range (ν opt ; shaded area), this will require viscosity classes VG 46 or VG 68; class to select: VG 68. Note: The leakage oil temperature, affected by pressure and speed, is always higher than tank temperature. However, temperature must not exceed 90 C anywhere in the system. Please contact us if it is not possible to meet the above conditions due to extreme service parameters or high ambient temperature. Selection chart Viscosity ν (mm Viskosität (mm 2 2 /s) /s) 00 600 400 200 0 80 60 40 20 15-20 0 20 40 60 80 0 00 VG 22 VG 68 VG 46 VG 32 VG 0 36 16 ν opt 25 30 50 70 90 Temperatur temperature t ( t ( C) t min = 25 C t max = + 90 C Druckflüssigkeitstemperaturbereich Hydraulic fluid range Hydraulic fluid filtering at the axial piston pump To ensure operational reliability, the service fluid must conform to at least purity class 9 to NAS 1638 18/15 to ISO/DIS 4406. 3/8

Technical specifications Service pressure range, input Absolute pressure at port S p abs min 0.8 bar p abs max 5 bar Service pressure range, output Pressure at port B Nominal pressure p N 250 bar Peak pressure p max 315 bar (pressures to DIN 24312) Leakage fluid pressure Maximum permissible leakage fluid pressure (at port L, L 1 ): p L max 2 bar absolut Always given with end-face leakage oil bore allowing unrestricted drainage into transmission housing. Pressure at lubrication oil port G: p abs min = 1bar Direction of flow S to B. Table of values (theoretical values, ignoring η mh and η v ; values rounded) Size 45 Displacement volume V g max cm 3 45 Max. speed * at V g max n o max rpm 2750 Max. volumetric flow (delivery) at n o max q Vo max L/min 123 Max. power ( p = 250 bar) at n o max P o max kw 52 Max. torque ( p = 250 bar) at V g max T max Nm 181 Moment of inertia around drive axle J kgm 2 0.0047 Fluid capacity L 0.6 Mass (without fluid) m kg 27.2 Permissible load on drive shaft: max. permissible axial force F ax max N 1500 max. permissible lateral force F q max N 1500 *intermittently 3000 rpm Application of force F q ± F ax /2 /2 Calculating size V g n η v Volumetric flow q V = 00 [L/min] Drive torque 1.59 V g p T = 0 η mh [Nm] 2π T n T n q V p Drive power P = = = [kw] 60000 9549 600 η t V g = geometric displacement volume [cm 3 ] per revolution p = pressure differential [bar] n = speed [rpm] η v = volumetric efficiency η mh = mechanical-hydraulic efficiency η t = total efficiency (η t = η v η mh ) 4/8

Characteristic curves for pump with pressure controller DR Drive power and delivery rate (volumetric flow) (service fluid: hydraulic oil ISO VG 46 DIN 51519, t = 50 C) Size 45 n = 1500 rpm n = 2600 rpm 120 60 Volume rate of flow q V [L/min] 0 80 60 40 20 0 50 q V P qv max P qv 0 150 200 Service pressure p [bar] 250 50 40 30 20 0 Drive power P[kW] 5/8

Before finalising your design, please request certified assembly drawing. Subject to alteration without notice. Unit dimensions size 45, clockwise direction of rotation DR Type ACO 45 DFR DFR1 /52 R -V U C 07 H00 2 D DRG 12 F 31 2 ø7/8" 21,5 15,1 1 W 90 80 87 127,5 L 1 L 9,5 G A/C S M1 G M2 C 21 1 3/8" UNF ø57 41 32 70,5 2,5 185 244 Shaft 22-4 (SAE B) shortened SAE J744 OCT 83 30 mesh angle, 13 teeth, 16/32 pitch 175 Filter supplied with unit for type F 235 B View W ø94 V 9 B SW 19 50 Nm SW 19 Nm SW 6 View V Pressure port B model 12 52,4 +0,2-0,2 M 26,2 +0,2-0,2 C S 25 Ports see page 7 6/8

Before finalising your design, please request certified assembly drawing. Subject to alteration without notice. Unit dimensions size 45, anti-clockwise direction of rotation DR Type ACO 45 DFR DFR1 /52 L -V U C 07 H00 2 D DRG 12 F 141,5 9 2,5 V 244 Shaft 22-4 (SAE B) shortened SAE J744 OCT 83 30 mesh angle, 13 teeth, 16/32 pitch 31 L 1 21,5 L W 15,1 ø7/8" S M1 G M2 A/C G 21 1,5 9,5 Filter supplied with unit for type F dimensions see page 6 1 3/8" UNF ø57 185 99,2 View W B 175 SW19 50Nm ø94 SW19 Nm SW 6 157 80 B C S 164 70,5 2 Ansicht View VV Pressure Anschluß port B B, Ausf. model 12 12 Ports Model 07 Model 12 B Pressure port M33x2 SAE 1" (standard pressure) S Suction port M48x2 M48x2 A/C Filter port, feed pump 1 3/8" UNF-2B 1 3/8" UNF-2B to DIN 71457-A1,2 L Case drain port M12x1,5 integrated M12x1,5 integrated L 1 Case drain port 7/8-14UNF-2B 7/8-14UNF-2B 25 26,2 +0,2-0,2 M 52,4 +0,2-0,2 Control pressure port M14x1,5 M14x1,5 with pressure controller DR port closed G Transmission lubrication port M18x1,5 M18x1,5 M 1, M 2 Measurement ports Mx1 Mx1 7/8

Circuit diagram Type ACO 45 DFR /52 - V U C H00 2D F Filter supplied with unit for type F must be set % higher than DR-control not supplied with unit p = max 0.2 bar at 130 L/min Ports B Pressure port S Suction port A/C Filter port, feed pump L, L 1 Case drain ports Control pressure port with pressure controller DR port closed G Transmission lubrication port M 1, M 2 Measurement ports GmbH, Werk Horb, D 72160 Horb, An den Kelterwiesen 14, Phone (07451) 920, Telex 765 321, Fax (07451) 8221 8/8 The data in this document is quoted solely for purposes of product description and should not be considered to constitute guaranteed and legally binding properties. Not to be reproduced or copied subject to technical change.