Polaris Deformity System Trivium Derotation System



Similar documents
Lentur Cable System. Surgical Technique

Degenerative Spine Solutions

September 25, Dear Ms. McCoy:

SILO Spinal System TSRH. Surgical Technique. as described by:

How To Use A Phoenix Retrograde Femoral Nail

TABLE OF CONTENTS. Indications and Contraindications 3. Features and Benefits 4. Ease of connection 4 Stable fixation concept 5

PERIPROSTHETIC IMPLANTS

ACCORD Cable System. Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri. Paul Di Cesare, MD New York, New York

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

MEDACTA UNCONSTRAINED SCREW TECHNOLOGY. Surgical Technique. Hip Knee Spine Navigation

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Hip Arthroscopy Product Guide

coligne treatment technology

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

The information contained in this document is intended for healthcare professionals only.

Rack installation instructions

MatrixNEURO CMF Matrix

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

Thoracic Spine Anatomy

Xia 4.5 Spinal System Paediatric System of the Xia Family. Surgical Technique

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

Biomechanics of the Lumbar Spine

(English) NEXUS SPINE SPACER SYSTEM

Posterior Referencing. Surgical Technique

DUKE ORTHOPAEDIC SURGERY GOALS AND OBJECTIVES SPINE SERVICE

Zimmer Small Fragment Universal Locking System. Surgical Technique

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Zimmer Periarticular Elbow Locking Plate System

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

ATLANTIS Anterior Cervical Plate System ATLANTIS Translational Plate. 510(k) Summary. February 2007

Tubular connection elements

Acetabular Wedge Augment System

Minimally Invasive Lumbar Fusion

HORIZONTAL INSTALLATION

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Patient Information. Lateral Lumbar Interbody Fusion Surgery (LLIF).

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Integrated Manhole Ladder System

Triac Printed Circuit Board Replacement

Technique Guide. VEPTR II. Vertical Expandable Prosthetic Titanium Rib II.

6 inch A-Arm Lift Kit WARNING: / installation instructions. will fit CLUB CAR DS. included:

Implant Extraction Guide Module One & Two

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

Planning and Achieving Lumbar Spinal Balance

Table of Contents Section 6 Table of Contents

Makes bends greater than 90 in a single operation

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

The Material Difference. Options for Rotator Cuff Repair, Labral Repair and Suture Management

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Milling Chuck Features

Presented by Zoran Maric, M.D. Orthopaedic Spine Surgeon May 22, 2010

Achilles Tendon Repair, Operative Technique

Lumbar Spine Anatomy. eorthopod.com 228 West Main St., Suite D Missoula, MT Phone: Fax: info@eorthopod.

MIN Set. Instruments for Minimally Invasive Neurosurgery. Aesculap Neurosurgery

the revo / mini-revo shoulder fixation system s u r g i c a l t e c h n i q u e

Standard Internal Hex

Skeletal System. Axial Skeleton: Vertebral Column and Ribs

TransFx External Fixation System Large and Intermediate Surgical Technique

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

Roller Chain Coupling

Shoulder Restoration System

The Right Choice. Exeter. total hip system

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

Zimmer Periarticular Proximal Tibial Locking Plate

Planning and Achieving Lumbar Spinal Balance. November 7, 2015 New York, NY. Course Chairmen: Dom Coric, MD Paul McAfee, MD, MBA EW YORK

How To Fix A Radial Head Plate

ANTERIOR LUMBAR INTERBODY FUSION (ALIF) Basic Anatomical Landmarks: Anterior Lumbar Spine

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Does the pain radiating down your legs, buttocks or lower back prevent you from walking long distances?

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

K17.11 DOOR BOLTS K17 DOORS

Front axle components, overview

Oregon Fuel Injection

CeSpace Titanium / PEEK

picomax The Pluggable Connection System

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

HermanMiller Aeron Posturefit Installation AE905A AE905B AE905C

Standard Sleep Pod Side Entry Assembly Instructions

V-TEK IVP System 2.7 System 4.0

Restoration Modular. Revision Hip System Surgical Protocol

NARROW DIAMETER implant

SPINAL FUSION. North American Spine Society Public Education Series

Cable System. For Orthopaedic Trauma Surgery.

Model/Sprinkler Identification Numbers

LVB ACQUISITION, INC. BIOMET, INC.

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Transcription:

Polaris Deformity System Trivium Derotation System A Three Dimensional Approach to Deformity Correction The Polaris Deformity System in combination with the Trivium Derotation System incorporates Enbloc vertebral body derotation as an innovative posterior spinal deformity correction technique. The system utilizes the power of pedicle screw fixation and enables surgeons to correct most spinal deformities in three dimensions.

Polaris Deformity System The Polaris Deformity System offers surgeons optimum corrective tools and techniques to achieve the desired spinal balance and function. The complete system is available in stainless steel and titanium. Cobalt chrome alloy rods are also available (5.5mm diameter) to be used with titanium implants only. The System includes a variety of implant options and user friendly instrumentation to ease challenging surgical cases for 5.5mm diameter and 6.35mm diameter systems. Helical Flange Locking Technology is the design of the plug and screw seat interface. It provides secure fixation with an enhanced closure mechanism that minimizes seat splay and cross threading. Implant Options Multi-axial Screw Family Multi-axial Iliac Screw Rods Commercially Pure Titanium Rod Cobalt Chrome Rod (5.5mm diameter only) Titanium Alloy Rod Stainless Steel Rod 4.0mm 4.75mm 5.5mm 6.5mm 7.5mm 8.5mm Fixed Screws Plugs 4.0mm 4.75mm 5.5mm 6.5mm 7.5mm 8.5mm Titanium Stainless Steel Hooks The Polaris Spinal System has a complete selection of Hooks featuring the Helical Flange design. Hook styles are color-coded by throat size (Titanium Only) and numbered accordingly. Throat Sizes: Small: 6.0mm (Gold) Medium: 7.5mm (Gray) Large: 9.0mm (Blue) Blade Size: Narrow: 5.0mm Wide: 7.3mm Bifid: 9.0mm 1 2 3 4 1) Pedicle Hook 2) Angled Hook (L and R) 3) Wide Laminar Hook 4) Narrow Laminar Hook 5 6 7 8 5) Reduced Throat Laminar Hook 6) Offset Hook (L and R) 7) Angled Laminar Hook 8) Extended Body NOTE: Hooks are numbered on the Blade for easy reference during the procedure.

Rod Reduction Options Rod Persuader Provides a powerful means to push the rod into the tulip. Squeeze the handle of the persuader until the rod is seated. The plug driver will fit within the cannulated portion of the persuader and facilitate plug application. Rod Manipulator Allows the surgeon to move the rod mediallateral of cephalad-caudal. It completely grabs the rod so there is minimal worry about the instrument slipping. Rod Rocker Attach the rocker to the site holes of either the top or bottom and cantilever or tilt the ruler down to persuade the rod into the tulip. Once the rod is seated, plug application can be executed. The encompassing rod pusher is designed to fit around the tulip to avoid potentially slipping into the dura or other sensitive anatomy. The distal tulip has slots so it is easy to see the rod being pushed completely into the tulip and the plug being inserted.

Trivium Derotation System The Trivium Derotation System incorporates an innovative posterior three-dimensional spinal deformity correction technique that utilizes the power of pedical screw fixation. The technique gives the surgeon the power to correct most spinal deformities in three dimensions. Attention to the design of the system is focused on maximizing the ease of use by following a stepwise, non-regressive technique to minimize fiddle and optimize efficiency. Direct Vertebral Column Manipulation Technique Step 1: Fixed screws are placed in clusters of 5-8 along the apices of the lumbar and thoracic curves. Step 2: Apply Trivium Derotation System instrumentation by attaching derotation levers, handle linkage rods, and combs. Derotation levers are attached to the fixed screws in the apical clusters. Derotation Helical Flange Plug The Trivium Helical Flange plug minimizes rod rotation upon torquing. Handle linkage rods are attached thru the handle of each cluster. Attach the comb to connect the lumbar and thoracic curve clusters respectively.

Step 3: Slowly derotate the spine by manipulating the clusters. Step 4: 3-Dimensional scoliosis correction is now complete. Cluster Alignment Rod Horizontalizer Slight over correction of the lumbar spine may be necessary to resist elasticity of the system. The spine is now corrected. Horizontalizer is placed in between derotators handles to angle the vertebral body.

At Biomet, engineering excellence is our heritage and our passion. For over 25 years, through various divisions worldwide, we have applied the most advanced engineering and manufacturing technology to the development of highly durable systems for a wide variety of surgical applications. Polaris Deformity System Trivium Derotation System A Three Dimensional Approach to Deformity Correction To learn more about this product, contact your local Biomet Sales Representative today. 100 Interpace Parkway Parsippany, NJ 07054 800.526.2579 www.biometspine.com BSP216569L 05/10 2010 EBI, LLC. All trademarks are the property of Biomet, Inc. or one of its subsidiaries unless otherwise indicated. Helical Flange is a registered trademark of Roger P. Jackson. Rx Only.