Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Similar documents
Environmental Analysis Using the ICS-3000 Ion Chromatography System

What is Eluent Generation?

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

Optimize Your Process Operations by Improving Process Monitoring

A Complete Solution for Method Linearity in HPLC and UHPLC

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Determination of Calcium and Magnesium in Brine

Dionex IonPac AS19-4µm

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Automation of Sample Preparation in Ion Chromatography

IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities

Anion chromatography using on-line recycled eluents

columns IonPac CS18 Cation-Exchange Column

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

INTRODUCTION. The principles of which are to:

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

Dionex ICS-1100 Ion Chromatography System

Thermo Scientific Dionex ICS-1100 Ion Chromatography System

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

METHOD Revision 1.0. May 2000

Standard methods in water analysis

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

IC Food Packs. Complete packs for food analysis. Free with every IC Food Pack: MagIC Net software Ultrafiltration

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

[ Care and Use Manual ]

Earning Customer Loyalty

Determination of Benzenesulfonic Acid Counterion in Amlodipine Besylate by Ion Chromatography

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Ion Chromatography in Environmental Analysis. Peter E. Jackson

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Thermo Scientific ConFlo IV Universal Interface

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

Assay for Citrate and Phosphate in Pharmaceutical Formulations Using Ion Chromatography

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

SUCRALOSE. White to off-white, practically odourless crystalline powder

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Carbohydrate in Coffee: AOAC Method vs a New Fast Ion Chromatography Method

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Determination of Trace Sodium in Diesel and Biodiesel Fuel

Thermo Scientific Vanquish UHPLC System. Revolutionize Your. UHPLC Experience

Determination of Total Nitrogen and Phosphorus in Wastewaters by Alkaline Persulfate Digestion Followed by IC

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide

ChromQuest 5.0 Chromatography Data System

AppsLab Library. A new online platform for Thermo Fisher Scientific applications and methods. Susanne Kramer, Ph.D. Product Manager AppsLab Library

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Determination of Anions and Cations Content in Romanian Drinking Waters by HPIC Method

WATERS QUANTITATIVE ANALYSIS solutions

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Amino Acid Analyzer L-8900

Dissolved and precipitated oxalate

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Flow Injection Analysis

8 Chemicals from water treatment and distribution

Determination of Caffeine in Beverages HPLC-1

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Gel Filtration Standard

Chapter 28: High-Performance Liquid Chromatography (HPLC)

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Research for leachables of nuclear grade cation exchange resin

Thermo Scientific Dionex UltiMate 3000 Variable Wavelength Detectors

Chromium Speciation in Drinking Water by LC-ICP-MS

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study

PosterREPRINT AN LC/MS ORTHOGONAL TOF (TIME OF FLIGHT) MASS SPECTROMETER WITH INCREASED TRANSMISSION, RESOLUTION, AND DYNAMIC RANGE OVERVIEW

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Name: Class: Date: 2 4 (aq)

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

CHEMICAL FORMULAS AND FORMULA WEIGHT CALCULATIONS

Oxidation States of Nitrogen

Analytical Test Report

QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd

Application Note 190 INTRODUCTION

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Tutorial 4 SOLUTION STOICHIOMETRY. Solution stoichiometry calculations involve chemical reactions taking place in solution.

Transcription:

Customer Application Note: 114 Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory Sébastien N. Ronkart, Ph.D.; Société wallonne des eaux, rue de la Concorde, 41, B-4800 Verviers, Belgium (www.swde.be) Key Words ICS-000 Ion Chromatography System Reagent Free Major and trace analysis Bromate Dionex IonPac columns Introduction Ion chromatography (IC) hyphenated to a conductivity detector (CD) is a well-established and accepted technique for the quantitative analysis of inorganic anions in drinking water. It allows the routine determination of chloride, fluoride, nitrate, and nitrite as well as bromide, phosphate, and sulfate. In 199, the World Health Organization (WHO) 1 set a guideline of 5 µg/l for bromate in drinking water and the Council Directive 98/8/EC set this parametric value at 10 µg/l bromate and a limit of detection (LOD) of.5 µg/l for the analytical performance of the method. However, the analytical performance of the IC-CD method is not sufficient to routinely reach such a low LOD for bromate analysis. The bromate detection limit can be improved to the sub-µg/l level by using preconcentration after sample pretreatment,,4 but this methodology is very time consuming for high-throughput laboratories. Other methods based on a large sample volume injection and the use of postcolumn reaction (PCR) in conjunction with IC followed by a UV-vis detector (IC-PCR-UV-vis) allow a low LOD for trace bromate analysis (usually sub-µg/l). 5-8 The use in series of a CD and a postcolumn reaction system followed by a UV-vis detector allows the determination of inorganic anions and trace concentrations of bromate. 9 However, a large sample volume injection is required which dramatically affects the peak symmetry, the width, and the resolution (sometimes causing co-elution) of some inorganic anion peaks such as chloride, nitrate, and sulfate, which can be present in drinking water at concentrations 100,000 times higher than bromate. In summary, good resolution for the major inorganic anion peaks and a low LOD for bromate determination is a difficult compromise to achieve. It dictates that laboratories split their method, which is time consuming and increases costs. For this reason, we present in this paper a method for the determination of fluoride, chloride, chlorite, chlorate, bromide, bromate, nitrite, nitrate, sulfate, and phosphate in different types of water samples without compromise between the sample volume injected in the chromatographic system and a low limit of quantification suitable for trace bromate determinations. Experimental The method is composed of two sets of chromatographic conditions used in parallel (chromatographic conditions 1 and chromatographic conditions ) on a Dionex ICS-000 ion chromatography system (Thermo Scientific, Sunnyvale, CA, USA). The detailed schematic of this method is presented in Figure 1. The Dionex ICS-000 system used in this study incorporates an electrolytic eluent generator (for KOH production), dual-piston pump with vacuum degas, two six-port injection valves fitted with two loops in series (5 and 50 µl), heated conductivity cell, column heater, and a postcolumn reaction system. A Thermo Scientific Dionex AS50 Autosampler was used for sample processing. Thermo Scientific Dionex Chromeleon 6.8 Chromatography Data System software was used for system control and data processing. Thermo Scientific Note: Today one would purchase a Dionex ICS-5000 dual system with a Dionex AS-AP Autosampler to execute this method.

EGC KOH PUMP 1 Mobile Phase 0.5 ml/min Ultrapure Water CRT-ATC Continuously Regenerated Anion Trap Column Chromeleon CDS Software 5 µl Sample Loop IonPac AG 19 IonPac AS 19 ASRS Conductivity Detector mm I.d. Anion Self-Regenerating Suppressor mm, 45 ma 5 ºC Hz 50 µl Sample Loop IonPac AG 9-HC AUTOSAMPLER 1000 µl Syringe Volume IonPac AS9-HC ASRS Heated Reaction Coil UV-vis Detector PUMP 4 mm I.d. 4 mm 60 ºC 67 nm,.5 Hz 1 ml/min Mobile Phase Na CO 9 mm H SO 4 ASRS H SO 4 0.05 N 0.75 N 4 mm AXP => 0.5 ml/min, 600 psi NaBr NaNo Figure 1. General representation of the chromatographic system. Chromatographic conditions 1 A Thermo Scientific Dionex IonPac AS19 (50 mm mm i.d.) analytical column and its respective guard column, the Dionex IonPac AG19 (50 mm mm i.d.), were used for the separation of fluoride, nitrite, bromide, phosphate, chlorate, nitrate, chloride, and sulfate. The mobile phase gradient program is presented in Table 1. Suppression was achieved using a Dionex ASRS electrolytic suppressor, supplied with external ultrapure water. Inorganic anions were detected using a suppressed conductivity detector. Table 1. Selected mobile phase program for chromatographic conditions 1 Time (min) KOH Concentration (mm) 0 10 10 18.5 45 18.5.5 60 6 10 Chromatographic conditions A Dionex IonPac AS9-HC (50 mm, 4 mm i.d.) and its guard column, the Dionex IonPac AG9-HC (50 mm, 4 mm i.d.), were used for the separation of chlorite and bromate. The mobile phase was 9 mm sodium carbonate (Na CO ). A pressurized postcolumn delivery module (Dionex AXP Auxiliary Pump) was used to deliver the postcolumn reagent at a flow rate of 0.50 ml/min. A 500 µl knitted reaction coil was placed in a postcolumn heater, set at 60 C, to mix the effluent and postcolumn reagent. The postcolumn reaction mixture consists of 0.5 mm sodium nitrite and 1 M sodium bromide. Acidification of the PCR reagent is realized using an ASRS suppressor which is regenerated with 0.75 M sulfuric acid. Chlorite and bromate were detected with an UV-vis detector at a wavelength of 67 nm... Standard solutions and samples All solutions were prepared in ultrapure water with a specific resistance of 18. MΩ cm (Millipore, Molsheim, France). Commercially available 1000 mg/l certified solutions of nitrate, sulfate, chloride, phosphate, bromide, nitrite, and fluoride (Merck, Darmstadt, Germany) and chlorite, chlorate, and bromate (Spex CertiPrep, Metuchen, NJ), were used to prepare working standard solutions. The concentrations of inorganic anions used for the calibration curve and the quality control of the analysis of drinking water are presented in Table.

Table. Concentrations of the anions used for the calibration curve and the quality control. Certified solutions used to prepare the quality control and the working standards were different. Anion Concentration of Anions (mg/l) Calibration Curve Quality Control Fluoride 1 0.5 0. 0.1 1 Nitrite 1 0.5 0.5 0.1 0.05 0.5 Bromide 1 0.5 0.5 0.1 0.05 1 Phosphate 1 0.5 0.5 0.1 0.05 1 Chlorite 0.0 0.01 0.005 0.00 0.001 0.0 Bromate 0.0 0.01 0.005 0.00 0.001 0.0 Chlorate 0. 0.1 0.05 0.0 0.01 0.1 Nitrate 100 50 5 10 5 50 Chloride 00 100 50 0 10 50 Sulfate 00 100 50 0 10 50 Results And Discussion.1 Method characteristics As presented in Figure 1, two sample loops (5 and 50 µl) were filled in series. The selected volumes were compatible with the selection of a ml vial. A larger volume would require the use of vial with a higher capacity (i.e., 5 ml). This would reduce the number of vials in the autosampler. Once the sample loops are filled, the valve switches to the inject position. On the one side, potassium hydroxide (KOH) mobile phase carries the content of the 5 µl sample loop to the Dionex IonPac AG19 guard column, the Dionex IonPac AS19 analytical column, ASRS suppressor, and then to the conductivity detector. On the other side, the Na CO mobile phase carries the content of the 50 µl sample loop to the Dionex IonPac AG9-HC guard column, the Dionex IonPac AS9-HC analytical column, the postcolumn reaction system, and then to the UV-vis detector. The use of different sample loop sizes, mobile phases, and detection systems for the simultaneous determination of the major inorganic anions and trace oxhalides (bromate and chlorite) presents the following main advantages. Advantages for the method for trace oxyhalide determinations (bromate and chlorite): A large injected volume (50 µl instead of 5 µl) improves the response for bromate and chlorite. Postcolumn reaction followed by UV-vis detection is selective for trace bromate and chlorite analysis. This improves the limit of quantification for these analytes. The resolution between chlorite and bromate under the applied chromatographic conditions appeared to be better on the Dionex IonPac AS9-HC column than on the Dionex IonPac AS19 column. Advantages for the method for major inorganic anions analysis: The injected volume (5 µl) allows good resolution. Larger injection volumes could result in unwanted peak-broadening and partial coelutions. KOH mobile phase is suitable for a good chromatographic resolution. As the mobile phase was electrolytically generated, only one isocratic pump was required to deliver the deionized water needed for the Dionex Reagent-Free Ion Chromatography (RFIC ) system, even for gradient elution.

. Anion chromatograms Figure shows representative chromatograms of a mixed anion solution (quality control) containing 0 µg/l bromate and chlorite, 0.1 mg/l chlorate, 0.5 mg/l nitrite, 1 mg/l fluoride, bromide, and phosphate, and 50 mg/l nitrate, chloride, and sulfate. The bromate peak is baseline-resolved from chlorite with a resolution of 1.54 and 1.59 for chromatographic conditions 1 and respectively. These resolutions meet the ISO 1106:011 requirement, which set a resolution of 1. or better. Although both chromatographic systems allow a good resolution of bromate with its closest peak (chlorite), the bromate peak shows a significantly enhanced response with postcolumn reaction followed by a UV-vis detector. For example, Figure shows that the bromate peak at a concentration of 1 µg/l is not quantifiable with the CD while the postcolumn reaction and the UV-vis detector permits bromate quantification. So, the proposed method allows the determination of 10 inorganic anions including both trace (i.e., bromate, chlorite) and major inorganic anions (i.e., chloride). This method of simultaneously analyzing the same sample under two chromatographic conditions avoids compromise between the injected volume and analyte peak resolution. (A) 80 0 180 10 80 0 1 4 5 6 7 8 9 10-0.05-0.07-0.09 7.5 1.5 0.5 7.8 8.1 8.4 8.7 9 7 5 6 Peaks: 1. Fluoride. Chlorite. Bromate 4. Chloride 5. Nitrite 6. Chlorate 7. Bromide 8. Nitrate 9. Sulfate 10. Phosphate (B) -0 1 8 1 18-0.5 4.5 1.5 0.5 5 5.5 6 6.5 7 10 8 Absorbance (mau) -0.5 1 8.5 4 4.5 5-8 1 18-4.5 5 5.5 6 6.5 7 Figure. Chromatograms of (A) 5 µl injected standard solution containing 0 µg/l chlorite, bromate; 0.1 mg/l chlorate; 0.5 mg/l nitrite; 1 mg/l fluoride, bromide, and phosphate; and 50 mg/l nitrate, chloride, and sulfate. (B) 50 µl injected standard solution containing 0 µg/l chlorite and bromate.

(A) 0.7 0.6 1 Peaks: 1. Chlorite. Bromate 0.5 Absorbance (mau) 0.4 0. 0. 0.1 0-0.1 4.5 4.9 5. 5.7 6.1 (B) 0.001-0.001-0.00-0.00-0.004-0.005-0.006 0 1 7. 7.7 8.1 8.5 8.9 Figure. (A) Chromatograms of ultrapure water containing 1 µg/l bromate and 1 µg/l chlorite with postcolumn reaction system and UV-vis detection (chromatographic condition ). (B) Chromatograms of ultrapure water containing 1 µg/l bromate and 1 µg/l chlorite with conductivity detection (chromatographic condition 1).. Limit of quantification (LOQ) LOQs were determined according to the NFT 90-10, a French norm based on the ISO 575 accuracy measurements methodology. This methodology analyzes trueness and precision of the determination for a sample containing inorganic anions at a concentration close to the supposed limit of quantification. This test ensures that accuracy (trueness and precision) does not exceed ± 60% of the supposed LOQ (Equations 1 and ). (Equation 1) (Equation ) With (Equation ) Where: is the general mean; s LOQ is the reproducibility standard deviation; is the repeatability variance; and s R is the inter-series variance. For more details about calculation of and s R, please refer to ISO 575 and NFT-9010. Table summarizes the LOQ for each anion in drinking water. They were obtained for inorganic anions using chromatographic conditions 1 (CD) and chromatographic conditions (UV-vis detection after postcolumn reaction). Table. LOQs of anions in drinking water with CD or UV-vis detection after postcolumn reaction. Conductivity Detection UV-vis Detection Anion LOQ (µg/l) LOQ (µg/l) Fluoride 5 - Nitrite 1.5 - Bromide 10 - Phosphate 150 - Chlorite - 0.5 Bromate - 0.1 Chlorate 5 - Nitrate 50 - Chloride 500 - Sulfate 15 -

Postcolumn reaction followed by UV-vis detection of bromate and chlorite allows an LOQ of 0.1 and 0.5 µg/l, respectively. Major and trace anions can be analyzed simultaneously using a gradient elution and CD detection for the major components, and large-loop injection, PCR, and UV-vis for saving time and being cost effective..4 Uncertainty measurement In routine analysis, the quality control is prepared daily from the 1000 mg/l certified solution. Table 4 presents the mean ( x ) and the standard deviation (s) which are useful in establishing warning limits ( x ± s) and control limits ( x ± s) of a control chart. Data were obtained from 10 quality controls which correspond to the analysis of around 000 samples. The detection system used (CD or UV-vis) has a significant impact on the uncertainty measurement of trace inorganic anions such as bromate. Figure 4 presents the control chart of bromate at a concentration of 0 µg/l. For bromate determinations, the warning limit ( x ± s ) and the control limit ( x ± s ) were significantly reduced when postcolumn reaction with UV-vis detection was used ( x = 19.0 ; s = 0.89 µg/l) compared to CD ( x = 1.6 ; s =.80). 40 (A) (B) Bromate concentration ( g/l) 0 0 10 0 Figure 4. Control chart for bromate at a concentration of 0 µg/l. (A) Conductivity detection (chromatographic conditions 1); (B) Postcolumn reaction and UV-vis detection (chromatographic conditions ). Table 4. Mean ( x ) and standard deviation (s) of 10 quality controls analyzed with CD or UV-vis detection. Conductivity Detection UV-vis Detection Anion x s Unit x s Unit Fluoride 1.04 0.05 mg/l - - - Nitrite 0.50 0.0 mg/l - - - Bromide 1.01 0.05 mg/l - - - Phosphate 0.99 0.07 mg/l - - - Chlorite - - - 0.5 1.4 µg/l Bromate (1.6) (.80) (µg/l) 19.0 0.9 µg/l Chlorate 97. 4.4 µg/l - - - Nitrate 50.4 1. mg/l - - - Chloride 50.9 1.0 mg/l - - - Sulfate 50.1 1.0 mg/l - - -

.5 Inter-laboratory tests The method has been used for the Aquacheck proficiency tests (Aquacheck Ltd, Bury Greater Manchester, England) for the determination of both major and trace inorganic anions. The selected proficiency schemes were chlorination and disinfection by-products, major inorganic components in hard water, major inorganic components in soft water, and nutrients and other compounds. The range of the expected values for these inter-laboratory schemes were: 0.456 1.57 µg/l (fluoride);.1 95.8 µg/l (chlorite);.8 10.8 µg/l (bromate); 9.70 79 mg/l (chloride); 0.086 7.56 mg/l (nitrite);. 77.7 µg/l (chlorate); 4.8 80.7 µg/l (bromide); 5.0 7. mg/l (nitrate); 11 49.10 mg/l (sulfate) and.041 5.65 mg/l (phosphate). Table 5 shows that from January 010 to June 011, the laboratory had very satisfying results. The average deviation from the assigned value was always well below ± 0%, highlighting the high reliability of our approach. The method, therefore, is efficient for the simultaneous determination of major and trace inorganic anions in water. Table 5. Proficiency test results for anion determinations with the postcolumn reaction and UV-vis detection system. Results are expressed in percentage of error compared to the expected value. Round of the proficiency scheme F- ClO - BrO - Cl- NO - ClO - Br- NO - SO 4 - PO 4-79 (01/010) -4.80 1.90 -.40-4.40 81 (0/010) 0.60 0.0 6.10.70.0 8 (0/010).60-5.80 7.90-10.0 85 (06/010) -1.0 0.80-7.0.10 0.0 86 (06/010).80-9.80-10.80-8.70 89 (07/010).10.60 16.00 1.0 0.50 90 (08/010).60-10.40-0.80-9.10 91 (09/010) 1.40 1.80-4.40-6.70 9 (10/010) -.0-1.60-7.00 0.10-1.70 94 (10/010) -1.80.00-1.80-7.0 97 (1/010) 7.10.0 1.70 1.80.00 98 (1/010) -9.0-7.80-5.0-11.50 99 (01/011) -4.00 5.40 0.00-4.10 401 (0/011) 1.90 1.40-9.50 1.00 1.50 40 (0/011) -1.0 -.40 -.10-1.90 405 (06/011) 1.00 1.40-10.80-1.40.60

Conclusion A method for the determination of trace and major inorganic anions in water was developed. It allows in a single run the simultaneous analysis of fluoride, bromide, phosphate, nitrate, chloride, sulfate, chlorite, and bromate with limit of quantification suitable for drinking water analysis. In comparison with the use of two methods for the determination of both major and trace inorganic anions, the proposed method is powerful and is time saving (and thus cost effective) which is suitable for laboratories doing high volume routine analysis. References 1. WHO. Guidelines for Drinking Water Quality. World Health Organization. Geneva, Switzerland. 199.. Council Directive 98/8/EC of November 1998 on the Quality of Water Intended for Human Consumption. Official Journal of the European Communities.. Joyce R.J., Dhillon H.S. Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography. J. Chromatogr. A. 1994, 671, 165 171. 4. Weinberg. H. Pre-Concentration Techniques for Bromate Analysis in Ozonated Waters. J. Chromatogr. A. 1994, 671, 141 149. 5. Weinberg H.S., Yamada H., Joyce R.J. New, Sensitive, and Selective Method for Determining Sub-µg/L Levels of Bromate in Drinking Water, J. Chromatogr. A., 1998, 804, 17 14. 6. Achilli M., Romele L. Ion Chromatographic Determination of Bromate in Drinking Water by Post-Column Reaction with Fuchsin. J. Chromatogr. A. 1999, 847, 71 77. 7. Delcomyn C.A., Weinberg H.S., Singer P.C. Use of Ion Chromatography with Post-Column Reaction for the Measurement of Tribromide to Evaluate Bromate Levels in Drinking Water. J. Chromatogr. A. 001, 90, 1 19. 8. Matsis V.M., Nikolaou E.C. Determination of Inorganic Oxyhalide Disinfection By-Products in Bottled Water by EPA Method 6.0 for Trace Bromate Analysis. Desalination, 008, 4, 1 9. 9. Thermo Fisher Scientific. Determination of Inorganic Oxyhalide Disinfection Byproduct Anions and Bromide in Drinking Water Using Ion Chromatography with the Addition of a Postcolumn Reagent for Trace Bromate Analysis. Dionex Application Note 16. In addition to these offices, Thermo Fisher Scientific maintains a network of representative organizations throughout the world. Dionex Products: (408) 77-0700 North America: U.S./Canada (847) 95-7500 South America: Brazil (55) 11 71 5140 Europe: Austria (4) 616 51 5 Benelux (1) 0 68 9768 () 5 494 Denmark (45) 6 6 90 90 France () 1 9 0 01 10 Germany (49) 616 991 0 Ireland (5) 1 644 0064 Italy (9) 0 51 6 167 Sweden (46) 8 47 80 Switzerland (41) 6 05 9966 United Kingdom (44) 176 6917 Asia Pacific: Australia (61) 940 5 China (85) 48 8 India (91) 764 75 Japan (81) 6 6885 11 Korea (8) 65 580 Singapore (65) 689 1190 Taiwan (886) 8751 6655 www.thermoscientific.com Legal Notices: 01 Thermo Fisher Scientific Inc. All rights reserved. Aquacheck is a registered trademark of Aquacheck Ltd. All other trademarks are property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Scientific Dionex products are, designed, developed, and manufactured under an ISO 9001 Quality System. CAN114 _E 01/1SV LPN0 Part of Thermo Fisher Scientific