Automation of Sample Preparation in Ion Chromatography

Size: px
Start display at page:

Download "Automation of Sample Preparation in Ion Chromatography"

Transcription

1 Automation of Sample Preparation in Ion Chromatography Praha, nd October 04 Ing. Roman Repáš ACO Sales Manager (IC and SP) Agenda Thermo Scientific Dionex Sample Preparation Products Automation of Sample Preparation in Ion Chromatography ph and Conductivity Measurement Inline Filtration Inline Sample Preparation Matrix Elimination using Dionex InGuard Chemistries Matrix Elimination with Selective Analyte Trapping

2 Thermo Scientific Dionex Sample Prep Product ine Thermo Scientific TM Dionex TM ASE TM 0 and 30 Accelerated Solvent Extractor Thermo Scientific Dionex AutoTrace TM 80 Solid-Phase Extraction (SPE) Instrument Thermo Scientific Dionex SolEx TM SPE Cartridges Genevac Rocket TM Evaporator Novel & Innovative Solutions How Does Accelerated Solvent Extraction Work? Cell loading Fill, heat, (min) equilibrate to 9 dynamic extraction Solvent Solvent Solvent Pump Mixing Valve Static extraction 0 to 99 cycle static extraction Relief Valve Rinse with 0. fresh solvent dynamic extraction Oven Extraction Cell Purge with nitrogen Static Valve Extract Total (min) ready 0 Collection Bottle

3 AutoTrace 80 : Automated SPE Extraction of large volume of liquid samples Automated SPE instrument for large volume aqueous samples (0 m to 4 ) Extracts 6 samples with unattended operation All SPE parameters automatically controlled EPA approved for drinking water extraction Dionex SolEx Solid-Phase Extraction Cartridges Cartridges designed for fast, and easy preconcentration of contaminants prior to analysis Offered in a variety of chemistries and sizes to fit your sample extraction needs Silica-Based SPE Cartridges SolEx C8 SolEx C8 SolEx C8-Clean (Phthalate-Free) SolEx C8-Clean (Phthalate-Free) SolEx C8- SolEx Unbonded Silica Carbon Based SPE Cartridges SolEx Activated Carbon SolEx Graphitized Carbon Polymeric New SolEx Phases SolEx HRPHS SolEx SAX SolEx SCX SolEx WAX SolEx WCX 3

4 Rocket Evaporator Rocket Evaporator ASE Pucks Flip Flop Vials Fully Automated Workflow: Fills gap not addressed by ASE or AutoTrace Reduces aboratory Error: Pucks allow direct sample transfer from the ASE Expedites Sample Processing: Flip Flops evaporator directly into autosampler vials Total Workflow Solution: Our Key Advantage Key Applications: Fracking: ASE and C/MS Cr(VI) in soil: ASE and IC Pesticides in beverages: AutoTrace and GC/MS Key Regulations: China GB and GB : SVOC in drinking water and wastewater EPA Method 34A: POPs in solid matrices EU Water Framework Directives Productivity: Thermo Scientific as the single sources of complete analytical workflow Reduced solvent use by as much as 90% Reduced extraction time to min/sample ASE 0 and ASE 30 AutoTrace 80 GC and GC/MS C/MS Rocket Evaporator IC 4

5 Automation of Sample Preparation in Ion Chromatography ph-conductivity Accessory A small unit mounts inside an AS-AP autosampler Conductivity detector and ph flow cells in series Measurements done prior (!) to injection Conditionals in CM USB connection for power and control/communication Fluidics connections Conductivity mode only- (no ph) just leave plug in place Outlet Port USB Connector ph Cell Port ph Cable Connector Inlet line

6 ph-conductivity Accessory Easy to install USB Connection for Power and Control eave plug for conductivity only Install ph electrode, if ph measurement is desired Conductivity based Method Selection 4 : Eluent Source: Eluent: Temp.: Thermo Scientific Dionex IonPac CSA, 3 0 mm EGC-MSA 0 mm MSA Ambient Inj. Volume: A:. µ 3 6 Flow Rate: B: µ 0. m/min Detection: Suppressed conductivity 0 B A 0 Minutes 0 Sample: 6 cation standard in 00 mm HCl. ithium 0. mg/m. Sodium 3. Ammonium. 4. Potassium. Magnesium. 6. Calcium 6

7 Inline Filtration with Thermo Scientific Dionex AS-DV Thermo Scientific Dionex AS-DV positive displacement autosampler Each sample uses a separate filter, NO carryover Filter caps (0 µm pore size) Very low dead volume Particulates tend to settle to the bottom, filter moves from top down oop and concentrator loading No sample waste ow cost autosampler No sample pump needed Dionex AS-DV: How Sample Injection Works To Injection Valve Filter (0 µm) 4 7

8 Inline Filtration with Cartridges and Valves High pressure In-ine filters Multiple configurations available Filter in sample line before injection valve Inline on high pressure side Dual filters and 0-port valve with backflush pump High capacity, high volume filter stack of 3 µm, 7 µm and 0.4 µm filters ow capacity, low volume filter frit, 0. µm Advantages Entire sample is filtered- no sample loss Small sample volume loaded onto filter maximizes capacity Filter backflush minimizes carryover and extends filter lifetime Inline Filtration: Easy to implement! Detector Suppressor Analytical Guard Auto- Sampler W S P C Inline Filter Waste Pump System Backpressure Indicates When to Exchange Filter 8

9 Inline Filtration: ow Pressure or High Pressure Detector Auto- Sampler Auto- Sampler Detector W S C Suppressor 0 Suppressor Waste P Pump Analytical Guard 3 4 Waste AXP W S C Analytical Guard AXP Waste Waste P Pump Filter on the high pressure side Filter on the low pressure side Auxiliary Valves, ICS-000 and ICS-00 Auxiliary Valves Enable Many Sample Prep Solutions 9

10 Thermo Scientific Dionex InGuard Cartridges Cartridges are high capacity Cartridge Type Ag H Na HRP Na/HRP Cartridge Capacity to. meq to. meq to. meq g resin 0% Na / 0% HRP Inline approach- sample volume per cycle equals injection volume Small amount loaded onto cartridge increases effective capacity to many samples per cartridge Reduced sample processing time, labor and cost High Capacity and Small Sample Volume: Many Samples / Cartridge Description of Matrix-Elimination using Thermo Scientific Dionex InGuard Products An autosampler or pump is used to pass the sample through the cartridge to remove matrix components. The cartridges have very low backpressure but the chemistries usually function optimally at flow rates between 0. and m/min. This Sample Preparation is suitable for both standard bore and microbore IC systems The number of samples that can be treated with an Dionex InGuardproduct depends on the matrix composition, concentration of compounds to be removed and the sample injection volume. 0

11 What is the General Setup? Pump Waste W Dionex InGuard Cartridge C P W S S Auto- Sampler P Pump C Concentrator or arge Transfer oop Guard Analytical Suppressor Detector Autosampler: Thermo Scientific Dionex AS-DV, AS-AP Thermo Scientific Dionex InGuard Cartridges Application example: Anion analysis in.6% NaCl, treat with Dionex InGuard Ag followed by Dionex InGuard Na 7.6% NaCl w/o InGuard : Thermo Scientific Dionex IonPac AG and AS, 4 mm Eluent: 3 mm KOH, EGC Flow rate: m/min Sample Prep: Dionex InGuard Ag and Na cartridges Injection vol: 00 µ Detection: Suppressed conductivity, Thermo Scientific Dionex ASRS Minutes 40.6% NaCl blank without InGuard.6% NaCl with DionexInGuardAgand Na Water blank with DionexInGuard Std of ppm nitrite, sulfate, nitrate in.6% NaCl using Dionex InGuard Peaks: mg/ (in standard) Chloride Nitrite 3 Carbonate 4 Nitrate Sulfate Dionex InGuardeasily removes interfering chloride, automatically

12 Anions in 0% NaOH Chloride Chlorate Sulphate min : Thermo Scientific Dionex IonPac AS9 w/ guard Eluent: mmol/ KOH Transfer Eluent: Water Flow: 0. m/min Transfer Flow: 0. m/min Sample Pretreatment: InGuard-H Detection: Suppressed conductivity Background Signal: <. /cm Suppressor: Thermo Scientific Dionex Anion ASRS 300, recycle mode Suppressor Current: 0 ma Temperature: 30 C Injection Volume: 0 µ Sample Transfer m oop: Sample Preparation: The samples 0% NaOH were diluted ad 0 with ultrapure water and immediately analysed Matrix-Elimination Using Analyte Trapping Eluent Pump Conc. Col. Guard Waste H O Transfer Pump ASRS AS Detector

13 Determination of Anions in -Propanol : Thermo Scientific Dionex IonPac AS8, x 0 mm Eluent: 8 to 48 mm KOH (EG) in 0 min Flow Rate: 0. m/min Inj. Volume: m concentrated on UTAC-UP Detection: Suppressed conductivity Temperature: 30 C Suppressor: Thermo Scientific Dionex ASRS, recycle mode with CRD Minutes Sample : Sample : Peaks: SEMI-grade IPA 4 µg/ spiked SEMI-grade IPA. Fluoride. Chloride 3. Sulfate 4. Nitrate. Phosphate 3488 Trace Anion Analysis of Electronic Grade Acetone Minutes 3 s: Thermo Scientific Dionex IonPac AG9-HC, AS9-HC, mm Concentrator : Dionex IonPac AG9-HC, 4 mm Eluent: 8.0 mm Sodium carbonate. mm Sodium hydroxide Eluent Flow Rate: 0. m/min Rinsing Flow Rate:.0 m/min Sample Volume:.0 m Detection: Suppressed conductivity, Thermo Scientific Dionex ASRS II, AutoSuppression external water mode Peaks:. Chloride 0.00 µg/ (ppb). Nitrate Sulfate

14 Anions from Water Insoluble Drug 4.0 Drug Formulation Methanol Blank Instrument: Thermo Scientific Dionex ICS-3000 and AS Concentrator: UTAC-UP ( x 3 mm) : Thermo Scientific Dionex IonPac AG ( mm)/ AS ( mm) RFIC-EG: KOH Gradient Temperature: 30 C Flow Rate: 0.4 m/min Inj. Vol.: 00 µ Detection: Suppressed conductivity Sample: Procedure: Drug formulation in Methanol. Sample passed through UTAC. Anions collected; drug passed to waste 3. UTAC flushed with water from AS to remove MeOH 4. Anions injected onto column Fluoride Sulfate Phosphate Pump Guard Chloride Nitrate Concentrator Waste Suppressor Minutes 30 Anions Trapped and Drug Substance Removed Autosampler Detector Determination of Trace Anions in Organic Solvent 4

15 Determination of Trace Anions in Organic Solvent.0 ÌS F Cl NO NO3.00 Concentration:.00 mm min SO Collector: IonSwift MAC-00 ( mm) : IonPac AG8-Fast capillary Guard(0.4 3mm) +IonPac AG8-Fast capillary(0.4 0mm) Switching-time: 0- min Eluent (KOH): 0-6min mm; 6-min -mm; -30min -4mM; 30-40min 4mM Flow-rate:0µ/min Sample volume: 0 μ Methanol Acetonitrile Isopropanol Acetone F Cl NO NO SO PO4 N.D. N.D N.D. Anions in Hydrogen Peroxide 8 Concentrator : TAC-P Trap : ATC- : Thermo Scientific Dionex IonPac AG, AS Eluent: KOH (EG40) Temperature: 3 C Flow Rate: m/min Injection Volume: 400 µ Detection: Suppressed conductivity Minutes Peaks:. Fluoride 9.8 µ (ppb). Acetate 3. Formate 4. Chloride Carbonate 6. Sulfate Oxalate 8. Nitrate Phosphate 3.64

16 Cations in Electronic Grade Hydrogen Peroxide 0,40 0,30 NH + 4 Na + (3,70 µg/) (3,77 µg/). 0,0 0, Minutes? K + (0,67 µg/) : Thermo Scientific Dionex IonPac CS0 with Guard (4mm) Concentrator: Thermo Scientific Dionex IonPac CGA (4mm) Eluent: 40 mmol/ MSA Flow Rate: m/min Injection volume: 000 µ Detection: Suppressed conductivity Suppressor: Thermo Scientific Dionex CSRS-Ultra, ext. Water Trace Anions in High Purity 4.% HF Pretreatment : Thermo Scientific Dionex IonPac ICE-AS6 ICE Eluent: Deionized water ICE Flow Rate: 0. m/min Sample Volume: 70 µ Minutes : Thermo Scientific Dionex IonPac AG9-HC, AS9-HC, mm Concentrator: Dionex IonPac AG9-HC, 4 mm IC Eluent: 8.0 mm Sodium carbonate. mm Sodium hydroxide IC Flow Rate: 0. m/min Detection: Suppressed conductivity, Thermo Scientific Dionex ASRS UTRA, AutoSuppression, external water mode Peaks:. Fluoride µg/ (ppb). Chloride Carbonate 4. Nitrate Unidentified 6. Sulfate Phosphate

17 Trace Anions in High Purity 8% Phosphoric Acid Ion Exclusion (ICE) Pretreatment : Thermo Scientific Dionex IonPac ICE-AS6 ICE Eluent: Deionized water ICE Flow Rate: 0.0 m/min Sample Volume: 00 µ mm Sodium Hydroxide Clean Up : Concentrator: IC Eluent: IC Flow Rate: Detection: Thermo Scientific Dionex IonPac AG-HC, AS-HC, mm Dionex IonPac AG-HC, 4 mm 0 mm Sodium hydroxide 0.38 m/min Suppressed conductivity, Thermo Scientific Dionex ASRS, AutoSuppression, external water mode Peaks:. Chloride 36 µg/ (ppb). Unidentified 3. Sulfate Nitrate. Phosphate Minutes Determination of Trace Anions in Weak Acids 7

18 Cl - NO 3 - Trace Anions in Formic acid Capillary IC st Dimension : Sample volume: 0 µ Thermo Scientific Dionex IonPac ICE-AS(0 9 mm) ion-exclusion column SO 4 - PO 4 3- nd Dimension Concentr. Col.: Thermo Scientific Dionex IonSwift MAC-00 ( mm) : Thermo Scientific Dionex IonPac AG8-Fast w/ guard (0.4 0mm) Eluent: KOH-Gradient (RFIC) Flow rate: 0 µ/min Detection: Suppressed Conductivity Suppressor: Thermo Scientific Dionex ACES (Recycle Mode) 0.0 Concentration:.00 mm min Trace Anions in Acetic Acid Capillary IC st Dimension : Sample volume: 0 µ Thermo Scientific Dionex IonPac ICE-AS(0 9 mm) ionexclusion column Cl - SO 4 - PO 4 3- nd Dimension Concentr. Col.: Thermo Scientific Dionex IonSwift MAC-00 ( mm) : Thermo Scientific Dionex IonPac AG8-Fast w/ guard (0.4 0mm) Eluent: KOH-Gradient (RFIC) Flow rate: 0 µ/min Detection: Suppressed Conductivity Suppressor: Thermo Scientific Dionex ACES (Recycle Mode) Concentration:.00 mm min 8

19 Thank you! 9

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) IonSwift MAC-100 & MAC-200 Product Manual Page 1 of 16 PRODUCT MANUAL for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC) MAC-100, 0.5 x 80mm (P/N 074702)

More information

Environmental Analysis Using the ICS-3000 Ion Chromatography System

Environmental Analysis Using the ICS-3000 Ion Chromatography System Environmental Analysis Using the ICS- Ion Chromatography System Ion chromatography (IC) is well established as a routine method for the analysis of ionic analytes in environmental samples. IC has been

More information

Dionex IonPac AS19-4µm

Dionex IonPac AS19-4µm Total Thermo Scientific Dionex IonPac AS9-4µm Column Product Manual P/N: September 203 Part of Thermo Fisher Scientific Product Manual for Dionex IonPac AS9-4µm Column Dionex IonPac AG9-4µm Capillary Guard

More information

Determination of Calcium and Magnesium in Brine

Determination of Calcium and Magnesium in Brine Application Note Determination of Calcium and Magnesium in Brine INTRODUCTION To prevent membrane poisoning, new membrane technology in chlor-alkali cells requires feed brine that is relatively free of

More information

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns Product Manual for SolEx TM HRP Cartridges and SolEx TM HRP RSLC Columns Page 1 of 15 Product Manual for SolEx TM HRP Cartridges SolEx HRP (P/N 074400)

More information

What is Eluent Generation?

What is Eluent Generation? What is Eluent Generation? Monika Verma Thermo Fisher Scientific, Sunnyvale, CA, USA White Paper 70607 Executive Summary Eluent generation is an electrolytic process that allows the production of high

More information

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory Customer Application Note: 114 Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory Sébastien N. Ronkart, Ph.D.; Société wallonne des eaux, rue de la

More information

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography Carl Fisher and Linda Lopez Thermo Fisher Scientific, Sunnyvale,

More information

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis Thermo Scientific SOLAµ SPE Plates Technical Guide Consistent excellence for bioanalysis SOLAµ - delivering reproducible low volume extractions. Everytime! Thermo Scientific SOLAµ plates are designed for

More information

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes Technical Note 64 Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes INTRODUCTION The AS Autosampler is enhanced with new features to speed throughput and simplify sample

More information

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in

More information

columns IonPac CS18 Cation-Exchange Column

columns IonPac CS18 Cation-Exchange Column columns IonPac CS Cation-Exchange Column The IonPac CS is a cation-exchange column of moderate capacity and hydrophobicity, recommended for isocratic and gradient separations of polar amines such as alkanolamines,

More information

Dionex ICS-1100 Ion Chromatography System

Dionex ICS-1100 Ion Chromatography System IET International Equipment Trading Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Dionex ICS-1100 Ion Chromatography

More information

Oasis HLB Cartridges and 96-Well Plates

Oasis HLB Cartridges and 96-Well Plates CONTENTS I. INTRODUCTION II. SAMPLE PRE-TREATMENT a. Biological Samples b. Solid Samples: Soil, Whole Foods, Tissue c. Aqueous Samples: Water, Beverages d. Non-Aqueous Liquid III. SOLID PHASE EXTRACTION

More information

High-Throughput 3-D Chromatography Through Ion Exchange SPE

High-Throughput 3-D Chromatography Through Ion Exchange SPE High-Throughput 3-D Chromatography Through Ion Exchange SPE Application Note 205 Luke Roenneburg and Alan Hamstra (Gilson, Inc.) Introduction 2-dimensional (2-D) separation is the separation of a sample

More information

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,

More information

Protocol: HPLC (amino acids)

Protocol: HPLC (amino acids) Page 1 of 6 1. Chemicals Composition M MW gram volume (ml) product code 0-pthaldialdehyde C 8H 6O 2 134.13 Sigma P0657 Perchloric acid HClO 4 3.5 100.46 Dilute 70% stock solution 1:1 with demi to obtain

More information

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in

More information

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation Application Note Determination of Nitrite and Nitrate in Fruit Juices by UV Detection Category Food Matrix Fruit Juice Method HPLC Keywords Ion pair chromatography, fruit juice, inorganic anions AZURA

More information

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers Automation, sample preparation Autosamplers for Ion Chromatography Dionex AS-AP Autosampler Advanced Features Perform full-loop, partial-loop,

More information

Purification of reaction mixtures using flash chromatography.

Purification of reaction mixtures using flash chromatography. Purification of reaction mixtures using flash chromatography. This technical note details the use of ISOLUTE Flash chromatography columns for the purification of reaction mixtures. What is flash chromatography?

More information

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide chromatography Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide The following guide provides considerations, tips and general guidelines for developing SPE methods using the Thermo

More information

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from uman Plasma Krishna Rao Dara, Dr. Tushar N. Mehta, Asia Pacific Center of Excellence, Thermo Fisher Scientific, Ahmedabad, India Application

More information

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography) ACETA.02-1 ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography) PRINCIPLE Isovaleraldehyde (IVA) and acetaldehyde are released from the syrup with the aid of dilute phosphoric acid and heat. The liberated

More information

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD* Method 552.1 Revision 1.0 Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD* UCT Products: EUQAX156 (quaternary amine with Cl - counter ion, 6 ml cartridge)** CLTTP050 (CLEAN-THRU

More information

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep Guide to Reverse Phase SpinColumns Chromatography for Sample Prep www.harvardapparatus.com Contents Introduction...2-3 Modes of Separation...4-6 Spin Column Efficiency...7-8 Fast Protein Analysis...9 Specifications...10

More information

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection Application Note 1097 Liu Qian, Zheng Hongguo and

More information

Thermo Scientific Dionex ICS-1100 Ion Chromatography System

Thermo Scientific Dionex ICS-1100 Ion Chromatography System CHROMATOGRAPHY Thermo Scientific Dionex ICS-1100 Ion Chromatography System Product Specifications The preconfigured Thermo Scientific Dionex ICS-1100 and ICS-1600 are the first integrated Reagent-Free

More information

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Application Note AN844 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Page 1 Extraction of, and from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis Introduction Catecholamines

More information

A Novel Approach to Low Volume Sample Preparation

A Novel Approach to Low Volume Sample Preparation A Novel Approach to Low Volume Sample Preparation Tony Edge, Jon Bardsley, Ken Meadows, Luisa Pereira International Symposium on Chromatography Salzburg, Austria September 2014 1 The world leader in serving

More information

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography INTRODUCTION The analysis of soft drinks for caffeine was able to be performed using UV-Vis. The complex sample

More information

Ion Selective Electrodes

Ion Selective Electrodes Ion Selective Electrodes OAKTON has a large selection of Ion Selective Electrodes () to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary

More information

Technical Spotlight. The Use of Ion Chromatography in the Printed Circuit Board Industry

Technical Spotlight. The Use of Ion Chromatography in the Printed Circuit Board Industry The Use of Ion Chromatography in the Printed Circuit Board Industry Keith M Sellers Senior Scientist Trace Laboratories East 5 North Park Dr. Hunt Valley, MD 21030 (410) 584-9099 ksellers@tracelabs.com

More information

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS Summary: Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS UCT Part Numbers: CUNAX226 - Clean-Up C8+NAX, 2mg/6mL BETA-GLUC- ml Beta-Glucuronidase Enzyme, liquid form SLAQ1ID21-3UM -

More information

The basic division explosives for forensic purposes is shown in Fig. 1

The basic division explosives for forensic purposes is shown in Fig. 1 Isolation, concentration and determination of post blast residua by liquid chromatography with DAD detector capillary electrophoresis with DAD detector Firearm fumes (gunshot residua, GSR) - various metallic

More information

Accelerated Solvent Extraction (ASE ) Sample Preparation Techniques for Food and Animal Feed Samples

Accelerated Solvent Extraction (ASE ) Sample Preparation Techniques for Food and Animal Feed Samples Technical Note 209 Accelerated Solvent Extraction (ASE ) Sample Preparation Techniques for Food and Animal Feed Samples INTRODUCTION Sample preparation is an essential part of any solidliquid extraction.

More information

Innovative vs Traditional

Innovative vs Traditional And in the red corner, introducing the challenger NASDAQ April 4 2011 243.47 $ 1.38 $ 0.58 % 0.07 $ 0.02 $ 39.4 % Technology DVD Digital Streamline Instant Play Internet Access Unlimited Selection No Late

More information

How To Test For Contamination In Large Volume Water

How To Test For Contamination In Large Volume Water Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples Keywords Application Note ENV0212 This collaboration study was performed

More information

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan Fast, Reproducible LC-MS/MS Analysis of and Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 685 Key Words Accucore C18, dextromethorphan, dextrorphan, SOLA CX Abstract

More information

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz Toxichem Krimtech 211;78(Special Issue):324 Online extraction LC-MS n method for the detection of drugs in urine, serum and heparinized plasma Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische

More information

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc. Halogen Free: What, Why and How Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc. We will discuss What are Halogens and how we interact with them. Why Halogens, within consumer

More information

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb Document: AND Lead 100 7 2013 Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb July, 2013 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of Contents

More information

ChromQuest 5.0 Chromatography Data System

ChromQuest 5.0 Chromatography Data System ChromQuest 5.0 Chromatography Data System User Guide for the Surveyor LC CHROM-97257 Revision A March 2008 2008 Thermo Fisher Scientific Inc. All rights reserved. Surveyor and ChromQuest are trademarks

More information

S olid Ph ase Extraction (SP E) Method:

S olid Ph ase Extraction (SP E) Method: Solid Phase Extraction of US EPA 535 for Chloroacetanilide and Acetamide Degradates in Drinking Water Samples Prior to Liquid Chromatography/ Tandem Mass Spectrometry Toni Hofhine, Horizon Technology,

More information

[ Care and Use Manual ]

[ Care and Use Manual ] ACQUITY UPLC CSH Columns Contents I. Getting started a. Column Connectors b. Column Installation c. Column Equilibration d. ecord Installation e. Initial Column Efficiency Determination f. VanGuard Pre-Columns

More information

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process Save Hours in Sample Preparation Reduce the time to prepare and inject samples

More information

IC Food Packs. Complete packs for food analysis. Free with every IC Food Pack: MagIC Net software Ultrafiltration

IC Food Packs. Complete packs for food analysis. Free with every IC Food Pack: MagIC Net software Ultrafiltration IC Food Packs Complete packs for food analysis Free with every IC Food Pack: MagIC Net software Ultrafiltration 02 Make your food analysis more efficient! Ion chromatography (IC) is a versatile, proven

More information

Opiates in Urine by SAMHSA GC/MS

Opiates in Urine by SAMHSA GC/MS application Note Gas Chromatography/ Mass Spectrometry Author Timothy D. Ruppel PerkinElmer, Inc. Shelton, CT 06484 USA Opiates in Urine by SAMHSA GC/MS Introduction The United States Department of Health

More information

Ion Exchange Determination of Na+ by Displacement and Zn 2+ Using Preconcentration. Reading: Harris pp. 641-647, 699

Ion Exchange Determination of Na+ by Displacement and Zn 2+ Using Preconcentration. Reading: Harris pp. 641-647, 699 Ion Exchange Determination of a+ by Displacement and Zn 2+ Using Preconcentration Reading: Harris pp. 641647, 699 Prelab Assignment: 1. The ph of a solution is 4.56. Determine the concentration and use

More information

DEIONIZATION IN A "NUT SHELL"

DEIONIZATION IN A NUT SHELL Deionized Water (DI) DEIONIZATION IN A "NUT SHELL" City water is passed through dark amber colored, caviar sized plastic beads called cation ion exchange resin. The cation resin is in the hydrogen form

More information

A Complete Solution for Method Linearity in HPLC and UHPLC

A Complete Solution for Method Linearity in HPLC and UHPLC Now sold under the Thermo Scientific brand A Complete Solution for Method Linearity in HPLC and UHPLC Frank Steiner, Fraser McLeod, Tobias Fehrenbach, and Andreas Brunner Dionex Corporation, Germering,

More information

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures. Page 16 of 87 3.3 Sample Collection, Storage and Preservation Figure 3 details required containers, sample volumes, preservation techniques, and holding times for proper sample collection. A discussion

More information

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid

More information

NITRIC OXIDE and NITROGEN DIOXIDE 6014

NITRIC OXIDE and NITROGEN DIOXIDE 6014 NITRIC OXIDE and NITROGEN DIOXIDE 6014 NO MW: 30.01 CAS: 10102-43-9 RTECS: QX0525000 46.01 10102-44-0 QW9800000 METHOD: 6014, Issue 1 EVALUATION: FULL Issue 1: 15 August 1994 OSHA : 25 ppm NO; C 1 ppm

More information

WRITING CHEMICAL FORMULA

WRITING CHEMICAL FORMULA WRITING CHEMICAL FORMULA For ionic compounds, the chemical formula must be worked out. You will no longer have the list of ions in the exam (like at GCSE). Instead you must learn some and work out others.

More information

QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd

QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd QUANTITATIVE AMINO ACID ANALYSIS Aurélie Lolia Applications Manager, Biochrom Ltd QUANTITATIVE AMINO ACID ANALYSIS Principles of amino acid analysis Ion exchange chromatography The Biochrom 30 physiological

More information

Name: Class: Date: 2 4 (aq)

Name: Class: Date: 2 4 (aq) Name: Class: Date: Unit 4 Practice Test Multiple Choice Identify the choice that best completes the statement or answers the question. 1) The balanced molecular equation for complete neutralization of

More information

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters

More information

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS UCT Part Numbers: ECQUEU750CT-MP - QuEChERS, Mylar packs containing 4 g magnesium sulfate, 1 g sodium chloride, 0.5 g sodium citrate dibasic

More information

Standard methods in water analysis

Standard methods in water analysis Branch General analytical laboratories; water analysis Keywords Water analysis; standard methods; ASTM; DIN; ISO; USP; EPA; SLMB; EN; SCA; titration; ion chromatography; voltammetry; branch 1; branch 2

More information

ION EXCHANGE FOR DUMMIES. An introduction

ION EXCHANGE FOR DUMMIES. An introduction ION EXCHANGE FOR DUMMIES An introduction Water Water is a liquid. Water is made of water molecules (formula H 2 O). All natural waters contain some foreign substances, usually in small amounts. The water

More information

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac.

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322. i.chianella.1998@cranfield.ac. SPE and HPLC Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0) 1234 758322 i.chianella.1998@cranfield.ac.uk Solid-Phase Extraction- SPE Simple, fast and efficient sample preparation

More information

Anion chromatography using on-line recycled eluents

Anion chromatography using on-line recycled eluents Journal of Chromatography A, 1089 (2005) 82 86 Anion chromatography using on-line recycled eluents Takashi Yokoyama, Hitoe Maekubo, Asami Sakai, Michio Zenki Department of Chemistry, Faculty of Science,

More information

ORGANIC SAMPLE PREPARATION

ORGANIC SAMPLE PREPARATION ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,

More information

SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001

SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, Chemistry 11, McGraw-Hill Ryerson, 2001 SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001 1. A small pin contains 0.0178 mol of iron. How many atoms of iron are in the pin? 2. A sample

More information

Experiment 8 - Double Displacement Reactions

Experiment 8 - Double Displacement Reactions Experiment 8 - Double Displacement Reactions A double displacement reaction involves two ionic compounds that are dissolved in water. In a double displacement reaction, it appears as though the ions are

More information

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method) Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method) Grace Analytical Lab 536 South Clark Street 10th Floor Chicago, IL 60605 April 15, 1994 Revision 2 Standard Operating Procedure

More information

Introduction. The following definitions may help you better understand the components of the data report.

Introduction. The following definitions may help you better understand the components of the data report. Introduction This document is designed to help our clients understand the quality control requirements and limitations of data reporting. There are three sections to this document. The first section will

More information

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay PO-CON1484E Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching ASMS 014 TP85 David R. Baker 1, John Warrander 1, Neil Loftus 1, Simon Hird

More information

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION TANNIC ACID Prepared at the 39th JECFA (1992), published in FNP Add 1 (1992) superseding specifications prepared at the 35th JECFA (1989), published in FNP 49 (1990) and in FNP 52 (1992). Metals and arsenic

More information

IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities

IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities ICMS and LCMS Determination of Ionic Liquids, Counterions, and Impurities Leo Wang, Detlef Jensen, and William Schnute Dionex Corporation, Sunnyvale, CA, USA; Dionex Corporation, Olten, Switzerland INTRODUCTION

More information

AMD Analysis & Technology AG

AMD Analysis & Technology AG AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds

More information

Chemistry B11 Chapter 6 Solutions and Colloids

Chemistry B11 Chapter 6 Solutions and Colloids Chemistry B11 Chapter 6 Solutions and Colloids Solutions: solutions have some properties: 1. The distribution of particles in a solution is uniform. Every part of the solution has exactly the same composition

More information

Research for leachables of nuclear grade cation exchange resin

Research for leachables of nuclear grade cation exchange resin International Journal of Smart Grid and Clean Energy Research for leachables of nuclear grade cation exchange resin Liang-Cheng Chen, Dah-Yu Kao, Tung-Jen Wen, Ping-Ji Huang Institute of Nuclear Energy

More information

Question Bank Electrolysis

Question Bank Electrolysis Question Bank Electrolysis 1. (a) What do you understand by the terms (i) electrolytes (ii) non-electrolytes? (b) Arrange electrolytes and non-electrolytes from the following substances (i) sugar solution

More information

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis UCT Product Numbers: CSDAU26: 2mg / 6mL SPE cartridge SLDA1ID21-3UM:

More information

INSTRUCTIONS 56-1190-98. Edition AC

INSTRUCTIONS 56-1190-98. Edition AC Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography

More information

Periodic Table, Valency and Formula

Periodic Table, Valency and Formula Periodic Table, Valency and Formula Origins of the Periodic Table Mendelѐѐv in 1869 proposed that a relationship existed between the chemical properties of elements and their atomic masses. He noticed

More information

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES JOHN F. BOSSLER, SIEMENS Water Technologies Corp., Hoffman Estates, IL RONALD TRAVIS, SIEMENS Water Technologies

More information

GC-xt. The most flexible GC /GC-MS liquid sample injector

GC-xt. The most flexible GC /GC-MS liquid sample injector GC-xt Prep and Load Platform The most flexible GC /GC-MS liquid sample injector Environmental Foods/Beverages Consumer Products Forensics Petrochemicals/Polymers Pharmaceuticals GC-xt Liquid mode Prep

More information

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Automation of Solid Phase Extraction and Column Chromatographic Cleanup Automation of Solid Phase Extraction and Column Chromatographic Cleanup Haibin Wan Ltd. Problems with Manual Operation 1. Unstable flow rate affects reproducibility and throughput. 2. Not convenient for

More information

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control Dr. Frank Steiner, 1 Andreas Brunner, 1 Fraser McLeod, 1 Dr. Sergey Galushko 2 1 Dionex Corporation, Germering,

More information

Optimize Your Process Operations by Improving Process Monitoring

Optimize Your Process Operations by Improving Process Monitoring Integral Process Ana Optimize Your Process Operations by Improving Process Monitoring All industrial processes have a common need reliable, accurate, and timely methods for analyzing process chemistry.

More information

Wastewater Reuse. Typical treated wastewater is:

Wastewater Reuse. Typical treated wastewater is: Wastewater Reuse Most metal finishing industries have in-house wastewater treatment to economically dispose of the acids, alkali, oils, and dissolved metals in the rinse water and occasional tank solution

More information

LACHAT METHOD NUMBER 10-204-00-5-D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately 3-500 g CN/L 2-500 g CN/L. 09e

LACHAT METHOD NUMBER 10-204-00-5-D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately 3-500 g CN/L 2-500 g CN/L. 09e 1 SIDE BY SIDE COMPARISON TABLE FOR THE DETERMINATION OF CYANIDE BY UV DIGESTION AND AMPEROMETRIC DETECTION FIA METHOD - 10-204-00-5-D (ASTM D7511-09 e ) TOPIC Method ASTM D7511-09e LACHAT METHOD NUMBER

More information

SUCRALOSE. White to off-white, practically odourless crystalline powder

SUCRALOSE. White to off-white, practically odourless crystalline powder SUCRALOSE Prepared at the 41st JECFA (1993), published in FNP 52 Add 2 (1993). Metals and arsenic specifications revised at the 63rd JECFA (2004). An ADI of 0-15 mg/kg bw was established at the 37th JECFA

More information

1. Read P. 368-375, P. 382-387 & P. 429-436; P. 375 # 1-11 & P. 389 # 1,7,9,12,15; P. 436 #1, 7, 8, 11

1. Read P. 368-375, P. 382-387 & P. 429-436; P. 375 # 1-11 & P. 389 # 1,7,9,12,15; P. 436 #1, 7, 8, 11 SCH3U- R.H.KING ACADEMY SOLUTION & ACID/BASE WORKSHEET Name: The importance of water - MAKING CONNECTION READING 1. Read P. 368-375, P. 382-387 & P. 429-436; P. 375 # 1-11 & P. 389 # 1,7,9,12,15; P. 436

More information

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE Waters Corporation Waters 2690/5 USER & TROUBLESHOOTING GUIDE Contents 2690/5 Theory Setup procedures. Troubleshooting the 2690/5 User maintenance of the 2690/5 Spare Parts 2 2690/5 Theory 2690/5 Solvent

More information

Extraction to Injection in a Single Process

Extraction to Injection in a Single Process Extraction to Injection in a Single Process MEPS Fast Miniaturized SPE Save hours in sample preparation Semi or fully automate to improve workflow and increase productivity Reduce solvent usage and sample

More information

METHOD 3510C SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

METHOD 3510C SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION METHOD 3510C SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION 1.0 SCOPE AND APPLICATION 1.1 This method describes a procedure for isolating organic compounds from aqueous samples. The method also describes concentration

More information

817 Bioscan. Bioscan. Instructions for Use 8.817.1003. CH-9101 Herisau/Switzerland E-Mail info@metrohm.com Internet www.metrohm.

817 Bioscan. Bioscan. Instructions for Use 8.817.1003. CH-9101 Herisau/Switzerland E-Mail info@metrohm.com Internet www.metrohm. Bioscan CH-9101 Herisau/Switzerland E-Mail info@metrohm.com Internet www.metrohm.com Instructions for Use 8.817.1003 CH-9101 Herisau/Switzerland E-Mail info@metrohm.com Internet www.metrohm.com Instructions

More information

A Practical Guide to Ion Chromatography AN INTRODUCTION AND TROUBLESHOOTING MANUAL. SeQuant. Innovators in Chemical Analysis

A Practical Guide to Ion Chromatography AN INTRODUCTION AND TROUBLESHOOTING MANUAL. SeQuant. Innovators in Chemical Analysis A Practical Guide to Ion Chromatography AN INTRODUCTION AND TROUBLESHOOTING MANUAL SeQuant Innovators in Chemical Analysis An introduction and troubleshooting manual 1 A PRACTICAL GUIDE TO ION CHROMATOGRAPHY

More information

HS 1003 Part 2 HS 1003 Heavy Metals Test

HS 1003 Part 2 HS 1003 Heavy Metals Test HS 1003 Heavy Metals Test 1. Purpose This test method is used to analyse the heavy metal content in an aliquot portion of stabilised hot acetic acid extract by Atomic Absorption Spectroscopy (AAS). Note:

More information

Amino Acid Analyzer L-8900

Amino Acid Analyzer L-8900 Amino Acid Analyzer L-8900 VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is

More information

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE User Guide for Reversed-Phase Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE Notice The information in this document is subject to change without notice and should not be construed as a commitment

More information

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Unmatched flexibility for low flow LC/MS EKSIGENT EKSPERT NANOLC 4 Focused ekspertise In 23, Eksigent changed the way scientists looked at nanoscale chromatography with the introduction

More information

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis 1.0 Purpose - This procedure specifies the required elements for the solid phase extraction of acidic,

More information