WE DESIGN, MANUFACTURE, SUPPLY AND SUPPORT ALL OF OUR PRODUCTS. THAT S 360 VALUE

Similar documents
Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature

ExStik TM ph Waterproof Meters

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters

UltraBasic Benchtop ph Meter Operation Manual

Conductivity and TDS Meters

Milwaukee USER MANUAL

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Compact Water Quality Meter B-700 series

ph 200 ph-/redox-/temperature Meter Operating instructions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

4-Channel Thermometer / Datalogger

Model 4510 Conductivity/TDS Meter Operating Manual

General Purpose ph/orp Sensors

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Ground Resistance Clamp On Tester

Care and use guide. Contents. a handy solution made easy. page

Compact ph Measuring Instruments

USEPA Electrode Method Method 8156

Hygro-Thermometer + InfraRed Thermometer Model RH101

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Multi-Range Programmable DC Power Supplies 9115 Series

MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL

User Guide. Temperature and Humidity Datalogger. Model 42280

DISSOLVED OXYGEN METER Model : DO-5509

User Manual. Thermo Scientific Orion VERSA STAR

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

DISSOLVED OXYGEN PROBE

Agilent 4339B/4349B High Resistance Meters

ph and Acidity in Tomato Sauce

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Multi-Range Programmable DC Power Supplies 9115 Series

Test equipment for temperature and its reduction

Care and use guide. Contents. a handy solution made easy. page

USB-500/600 Series Low-Cost Data Loggers and Accessories

ph and Acidity in Wine and Fruit Juice

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Galvanic Parts Per Million Dissolved Oxygen Systems

Microwave Meter. Instruction Manual

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

Digital inductive conductivity transmitter

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Hand-held thermometer Model CTH7000

Conductivity measurements are used for applications such as in the production of ultrapure water or determining the salinity of sea water.

ph Measurement and Control

Operating Instructions

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

RS DIGITAL THERMOMETER

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

SenTix 950 SenTix 980

CyberScan 6000 Series. Bench Meters. ph ph FET ORP Ion Conductivity TDS Salinity Resistivity Dissolved Oxygen BOD (OUR,SOUR)

USB-500/600 Series Low-Cost Data Loggers and Accessories

Ground Resistance Clamp-On Tester

Operating manual. Multi 340i. mg/l. ARng. ph/dissolved Oxygen/Conductivity Measuring Instrument. ba52318e02 03/2004

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

EasyTrack 2 Accessories List

Operating manual. ph/cond 3400i. Tref25 nlf C TP CAL. ph/conductivity measuring instrument. ba75687e01 01/2007

TENSIONMETER ** code 183_LNRSTW **

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

Instruction Manual ph 5+ ph 6+ Ion 6+ Technology Made Easy...

The Effect of Temperature on Conductivity Measurement

HND-R. Hand-held ph, Redox and Temperature Measuring Units

Duct Humidity Transmitter

Equipment for Analysis

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

A Potentiometric Analysis of Fluoride Ion in Toothpaste

ACL 800 MEGOHMMETER OPERATION MANUAL

Combination ph/redox (ORP) Sensors

Dock HP Pro Portable Tablet Dock. HP Quick Charge 18W AC Tablet Adapter. HP Duet Pen Refills. Cables HP Micro USB to USB Adapter

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

REDOX AND REFERENCE ELECTRODE USER MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

OT 40L / 90L. Laboratory Steam Sterilizers

Product Description Sheet RB15 200D Gantry Robot Item No

Agilent Cary 60 UV-Vis

Agilent 4338B Milliohm Meter

Dual Laser InfraRed (IR) Thermometer

Handbook. Thermo Scientific. ph Electrode Selection Handbook

804 Ti Stand. Manual EN

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Measurement by Ion Selective Electrodes

Instruction Manual. T3111 T3111L T3111P T3111Ex

O C M III. Open Channel Flow Monitor

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

General Purpose ph/orp Sensor

ph, redox and I.S.E. electrodes

Multi-Function Ground

BIOMEDICAL REFRIGERATORS

Ion Selective Electrodes

Transcription:

BENCHTOP METERS

2 WE DESIGN, MANUFACTURE, SUPPLY AND SUPPORT ALL OF OUR PRODUCTS. THAT S 360 VALUE Over the past 30 years, HANNA has never failed to design fresh and innovative products and the new Benchtop Meters are no exception. HANNA is the largest family-owned manufacturer of analytical instrumentation in the world. The Benchtop Meters are manufactured in our European state-of-the-art ISO 9001:2000 production facility and are CE compliant to EN 61326-1 and EN 61010-1 standards. When you buy a HANNA product, you re not only buying the best value for your money, but you re also adding the benefit of HANNA s unsurpassed customer service and post-sale technical support.

SIMPLICITY IN DESIGN HANNA s new Benchtop Meters are an affordable solution for laboratory testing without compromising accuracy. These benchtop meters are compatible with a wide range of electrodes with BNC connectors. They feature an extra wide (6.5 x 1.5 ) LCD which displays both the primary reading and temperature simultaneously. These meters also feature prompts and symbols that guide the user during the calibration procedure as well as during measurements. GENERAL SPECIFICATIONS Probe Probe HI 1131B Glass-body Combination Electrode with 1 m (3.3 ) Cable HI 7662-T Probe 12 Input impedance 10 ohms Power Supply Environment 12 VDC 0 to 50 C (32 to 122 F); RH max 95% non-condensing FEATURES Extra wide LCD (6.25 x 1.5 ) Simultaneous display of primary reading and temperature On-screen calibration guides Automatic temperature compensation Dimensions 235 x 218 x 108 mm (9.2 x 8.5 x 4.2 ) Weight 1.3 Kg (2.9 lb); with holder 2.1 Kg (4.6 lb.) Glass Body Electrode & Starter Solutions Included! FIND THE INSTRUMENT THAT S RIGHT FOR YOU 3 HI 2250 HI 2223 HI 2221 HI 2216 HI 2215 HI 2214 HI 2213 HI 2212 HI 2211 HI 2210 Page 4 6 6 8 9 9 10 10 11 11 ISE EC/TDS NaCl Cal. Points Up to 5 Up to 5 Up to 5 Up to 5 Up to 5 Up to 5 Up to 3 Up to 3 Up to 2 Up to 2 ATC Auto Calibration CAL CHECK GLP Calibration Exp. Reminder Standard Buffers 7 7 7 7 7 7 5 5 5 5 Custom Buffers 2 2 2 2 2 2 PC Compatible USB USB USB USB USB USB Manual Logging 200 500 100 200 100 100 Interval Logging 500 500 500

4 HI 2550 / and EC/TDS/NaCl Meter Up to 5 point calibration with 7 standard and 2 custom buffers Autoranging (EC/TDS) Automatic temperature compensation ( & EC) Manually log up to 200 records and interval log up to 500 records PC compatible via USB GLP (Good laboratory Practice) GLP is a set of functions that allows storage and retrieval of data regarding the maintenance and status of the electrode. All data regarding, Rel, EC and NaCl calibration is stored for the user to review when necessary. Calibration Expiration Reminder For calibration, this instrument allows the user to set the number of days before the next required calibration. This value can be set from 1 to 7 days, or disabled. Calibration data The last calibration data is stored automatically after a successful calibration.

SPECIFICATIONS HI 2550 Range ISE & ORP EC TDS -2.0 to 16.0 ; -2.00 to 16.00 ; -2.000 to 16.000 ± 999.9 ; ± 2000 0.00 to 29.99 µs/cm; 30.0 to 299.9 µs/cm; 300 to 2999 µs/cm; 3.00 to 29.99 ms/cm; 30.0 to 200.0 ms/cm; up to 500.0 ms/cm uncompensated 0.00 to 14.99 ppm; 15.0 to 149.9 ppm; 150 to 1499 ppm; 1.50 to 14.99 g/l; 15.0 to 100.0 g/l; up to 400.0 g/l uncompensated (with 0.80 factor) NaCl 0.0 to 400.0% Resolution ISE & ORP EC TDS NaCl 20.0 to 120.0 ºC ( and EC range) 0.1 ; 0.01 ; 0.001 0.1 (±999.9 ); 1 (± 2000 ) 0.01 µs/cm; 0.1 µs/cm; 1 µs/cm; 0.01 ms/cm; 0.1 ms/cm 0.01 ppm; 0.1 ppm; 1 ppm; 0.01 g/l; 0.1 g/l 0.1% NaCl 0.1 ºC ± 0.01 ; ± 0.002 ISE & ORP ± 0.2 (±999.9 ); ± 1 (±2000 ) 5 Accuracy Relative Offset Calibration EC Calibration NaCl Calibration Compensation Cond. Temp. Coefficient EC TDS NaCl ± 1 % reading (±0.05 µs/cm or 1 digit, whichever is greater) ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) ±1% of reading ± 0.4 ºC (excluding probe error) ±2000 Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and 2 custom buffers 1 point slope calibration; 6 buffers available: 84.0 µs/cm, 1413 µs/cm; 5.00 ms/cm, 12.88 ms/cm, 80.0 ms/cm, 111.8 ms/cm; 1 point offset: 0.00 µs/cm 1 point with HI 7037L buffer (optional) Manual or Automatic from -20.0 to 120.0 ºC ( RANGE); -20.0 to 120.0 ºC (EC RANGE) (can be disabled on conductivity range to measure actual conductivity) 0.00 to 6.00 %/ºC (for EC and TDS only) default value is 1.90 %/ºC TDS Factor 0.40 to 0.80 (default value is 0.50) ORDERING INFORMATION HI 2550 is supplied with HI 1131B glass-body combination electrode with 1 m (3.3') cable, HI 76310 conductivity/tds probe, HI 7662 temperature probe, HI 76404N electrode holder, 4.01 & 7.01 buffer solutions (20 ml each), HI 7071S electrolyte solution, 12 VDC power adapter and instruction manual.

6 HI 2221 & HI 2223 Calibration Check Meters Up to 5 point calibration with 7 standard and 2 custom buffers Automatic temperature compensation Manually log up to 200 records and interval log up to 500 records PC compatible via USB Enhanced calibration messages and electrode diagnostics GLP (Good laboratory Practice) GLP is a set of functions that allows storage and retrieval of data regarding the maintenance and status of the electrode. All data regarding, Rel, EC and NaCl is stored for the user to review when necessary. Calibration Expiration Reminder For calibration, this instrument allows the user to set the number of days before the next required calibration. This value can be set from 1 to 7 days, or disabled. Calibration data The last calibration data is stored automatically after a successful calibration.

Enhanced Calibration Messages Calibration Error and Warning Messages The calibration history is used to issue error and warning messages during calibration to help ensure the highest accuracy. If a substantial change is seen from a previous calibration, error messages such as to clean or check the electrodes and/or buffers appear if the calibration parameters are out of accepted windows. Calibrations cannot be completed until the errors are corrected. Enhanced Electrode Diagnostics Electrode Condition and Response Time When using an appropriate HANNA P-Type BNC electrode, the HI 2221 and HI 2223 will assess the electrode condition and response time during each calibration and display the status for the rest of the day. The digital gauge for electrode condition is a representation of the offset and slope performance of the electrode. The response gauge is a function of the stabilization time between the first and second calibration buffers. The condition and response are also visible when viewing GLP data. SPECIFICATIONS HI 2221 HI 2223 2.00 to 16.00 2.00 to 16.00 ; 2.000 to 16.000 Range ± 699.9 ; ± 2000 ±999.9 ; ±2000 20.0 to 120.0 C 0.01 0.01 ; 0.001 7 Resolution 0.1 (± 699.9 ); 1 (± 2000 ) 0.1(± 999.9); 1(± 2000) 0.1 C ± 0.01 ±0.01 ; ±0.002 Accuracy ± 0.2 (± 699.9 ); ± 1 (± 2000 ) ±0.2(± 999.9); ±1(± 2000) ± 0.2 C (excluding probe error) Calibration Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and 2 custom buffers Compensation Manual or automatic from -20 to 120 C Electrode Probe PC Connection HI 1131P glass body, single junction, refillable with BNC connection and 1 m (3.3') Cable HI 7662 stainless steel probe USB Data Logging 100 points 500 points ORDERING INFORMATION HI 2221 and HI 2223 are supplied with HI 1131P glass-body combination electrode with 1 m (3.3') cable, HI 7662 temperature probe, HI 76404N electrode holder, 4.01 & 7.01 buffer solutions (20 ml each), HI 7071S electrolyte solution, 12 VDC power adapter and instruction manual.

HI 2216 Meter with ISE The HI 2216 is state of the art, heavy-duty,, ISE meter designed to provide laboratory results and accuracy under harsh industrial conditions. HI 2216 can also measure Oxidation Reduction Potential (ORP) in range and ion concentration using ISE (Ion Selective Electrodes). Relative feature is also provided. Simultaneous display of primary reading and temperature On-screen calibration guides Up to 5 point calibration with 7 standard buffers SPECIFICATIONS HI 2216 Range ISE 2.0 to 16.0 ; 2.00 to 16.00 ; 2.000 to 16.000 ±999.9 ; ±2000 0.001 to 19990 ppm 20.0 to 120.0 ºC 0.1 ; 0.01 ; 0.001 0.1 ; 1 Resolution 0.001 (to 1.999 ppm); 0.01 (to 19.99 ppm); 0.1 (to 199.9 ppm); ISE 1 (to 1999 ppm); 10 (to 19990 ppm) 0.1 ºC ±0.01 Accuracy ±0.2 (±999.9 ); ±1 (±2000 ) ISE ±0.5% FS ±0.4 ºC (excluding probe error) Relative Offset Range ±2000 Calibration Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and 2 custom buffers Compensation Manual or Automatic from -20 to 120ºC Electrode HI 1131B glass body, single junction, refillable with BNC connection and 1 m (3.3') Cable PC Connectivity USB Data Logging Manual: 200 records; Interval: 500 records Up to 2 point ISE calibration with 5 standard solutions Good laboratory practice Calibration expiration reminder Automatic temperature compensation Manually log up to 200 records and interval log up to 500 records PC compatible via USB ORDERING INFORMATION HI 2216 is supplied with HI 1131B glass-body combination electrode with 1 m (3.3') cable, HI 7662 temperature probe, HI 76404N electrode holder, 4.01 & 7.01 buffer solutions (20 ml each), HI 7071S electrolyte solution, 12 VDC power adapter and instruction manual.

HI 2214 2215 0.001 Resolution and Datalogging Meters The HI 2215 is a 0.001 resolution microprocessorbased and bench meter that can also measure Oxidation Reduction Potential (ORP) in. Relative feature is also provided. The HI 2214 is a microprocessor-based and bench meter that can measure Oxidation Reduction Potential (ORP) in. SPECIFICATIONS HI 2214 HI 2215 Range Resolution Accuracy 2.0 to 16.0 ; 2.00 to 16.00 ±999.9 ; ±2000 20.0 to 120.0 ºC 2.0 to 16.0 ; 2.00 to 16.00 ; 2.000 to 16.000 0.1 ; 0.01 0.1 ; 0.01 ; 0.001 0.1 ; 1 0.1 ºC ±0.01 ±0.2 (±999.9 ); ±1 (±2000 ) Extra wide LCD (6.25 x 1.5 ) Simultaneous display of primary reading and temperature On-screen calibration guides Up to 5 point calibration with 7 standard buffers Good laboratory practice Calibration expiration reminder Automatic temperature compensation Manually log up to 100 records Interval log up to 500 records (HI 2215) PC compatible via USB 9 Relative Offset Range Calibration ±0.4 ºC (excluding probe error) ±2000 Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and 2 custom buffers Compensation Manual or Automatic from -20 to 120ºC Electrode PC Connectivity Data Logging Manual: 100 records HI 1131B glass body, single junction, refillable with BNC connection and 1 m (3.3') Cable USB Manual: 100 records; Interval: 500 records ORDERING INFORMATION HI 2214 and HI 2215 are supplied with HI 1131B glass-body combination electrode with 1 m (3.3') cable, HI 7662 temperature probe, HI 76404N electrode holder, 4.01 & 7.01 buffer solutions (20 ml each), HI 7071S electrolyte solution, 12 VDC power adapter and instruction manual.

HI 2212 & HI 2213 Meters with 3 Point Calibration The HI 2212 and HI 2213 are microprocessor- based and temperature bench meters. HI 2213 can also measure Oxidation Reduction Potential (ORP) in range. Relative feature is also provided. 10 SPECIFICATIONS HI 2212 HI 2213 2.00 to 16.00 Simultaneous display of primary reading and temperature On-screen calibration guides Up to 3 point calibration with 5 standard buffers and 2 custom Good laboratory practice Calibration expiration reminder Automatic temperature compensation Range ±699.9 ; ±2000 20.0 to 120.0 ºC 0.01 Resolution 0.1 ; 1 (ISE & ORP) 0.1 ºC ±0.01 Accuracy ±0.4 ºC (excluding probe error) ±0.2 (±699.9 ); ±1 (±2000 ) Relative Offset Range ±2000 Calibration Up to 3 point calibration, 5 standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01), and 2 custom buffers Compensation Manual or Automatic from -20 to 120ºC ORDERING INFORMATION HI 2212 and HI 2213 are supplied with HI 1131B glass-body combination electrode with 1 m (3.3') cable, HI 7662 temperature probe, HI 76404N electrode holder, 4.01 & 7.01 buffer solutions (20 ml each), HI 7071S electrolyte solution, 12 VDC power adapter and instructions.

HI 2210 & HI 2211 //ºC Meters HANNA s new HI 2211 and HI 2210 are microprocessor based and C meters. HI 2211 adds a dual range (±399.9 or ±2000 ) which can be used for ISE measurements, ORP measurements or to check the offset and slope of the electrode. 1 or 2 point calibration with 5 standard buffers Simultaneous display of and Automatic Compensation SPECIFICATIONS HI 2210 HI 2211-2.00 to 16.00 11 Range ±399.9 ; ±2000-9.9 to 120.0 C 0.01 Resolution 0.1 ; 1 0.1 C ±0.01 Accuracy (@20 C) ±0.2 (±399.9 ); ±1 (±2000 ) ±0.5 C (0.0 100.0 C); ±1 C (outside) (excluding probe error) Calibration Compensation Electrode Up to 2 points, 5 standard buffers available ( 4.01, 6.86, 7.01, 9.18, 10.01) Manual or automatic from -9.9 to 120.0 C HI 1131B glass-body, single junction, refillable with BNC connector and 1 m cable ORDERING INFORMATION HI 2210 and HI 2211 are supplied with HI 1131B glass-body combination electrode with 1 m (3.3') cable, HI 7662 temperature probe, electrode holder, 4.01 & 7.01 buffer solutions (20 ml ea.), HI 7071S electrolyte solution, 12 VDC power adapter and instruction manual.

Electrodes, Solutions & Accessories BUFFER SOLUTIONS ELECTRODE REFILL SOLUTION HI 70004P HI 7004L HI 70007P HI 7007L HI 70010P HI 7010L 4.01 buffer solution, (25) 20 ml sachets 4.01 buffer solution, 500 ml 7.01 buffer solution, (25) 20 ml sachets 7.01 buffer solution, 500 ml 10.01 buffer solution, (25) 20 ml sachets 10.01 buffer solution, 500 ml HI 7071 3.5M KCl + AgCl electrolyte for single junction electrodes (4) 30 ml ACCESSORIES HI 76404N Electrode holder HI 92000 Windows compatible software. CONDUCTIVITY SOLUTIONS* 12 HI 70030C HI 7030L HI 70031P HI 7031L HI 70033P HI 7033L HI 70039P HI 7039L HI 7034L 12880 µs/cm, (25) 20 ml sachets 12880 µs/cm, 500 ml 1413 µs/cm, (25) 20 ml sachets 1413 µs/cm, 500 ml 84 µs/cm, (25) 20 ml sachets 84 µs/cm, 500 ml 5000 µs/cm, (25) 20 ml sachets 5000 µs/cm, 500 ml 80000 µs/cm, 500 ml *µs/cm (µmho/cm) ELECTRODES ORP PRETREATMENT SOLUTIONS HI 7091L Reducing pretreatment solution, 500 ml HI 7092L Oxidizing pretreatment solution, 500 ml TDS SOLUTIONS HI 7032L 1382 ppm (mg/l), 500 ml ELECTRODE CLEANING SOLUTIONS HI 7061L General cleaning solution, 500 ml ELECTRODE STORAGE SOLUTIONS HI 70300L Storage solution, 500 ml HI 1230B HI 1131B HI 1083B FC 200B HI 1413B Plastic-body (PEI), double junction, gel-filled, combination electrode. Use: general, field Glass-body, single junction, refillable, combination electrode. Use: general purpose Glass-body, micro, Viscolene, non-refillable, combination electrode. Use: biotechnology, micro titration Plastic-body (PVDF), open junction, conic, Viscolene, non-refillable, combination electrode. Use: meat & cheese. Glass-body, single junction, flat tip, Viscolene, non-refillable, combination electrode. Use: surface measurement P/L HI2250-HI2210_INC 1.0 PRINTED IN USA