ph, redox and I.S.E. electrodes
|
|
|
- Douglas Hodges
- 9 years ago
- Views:
Transcription
1 ph, redox and I.S.E. electrodes Complete and clear offer which makes easy the choice of the suitable model without user s confusion. ph electrodes: four models for portable instrument, five basic laboratory models and four models for special applications. Every basic model is also manufactured with built-in temperature probe, T version. The system ContATC (patented) ensures maximum response speed in the temperature measurement. Redox and new range of last generation I.S.E. electrodes are available too. The I.S.E. do not require internal electolyte and their solid state membranes have long duration.
2 High quality sensors to cover all type of applications.
3 ph combined electrode ESSENTIAL PARTS Cable Diaphragm The electrodes presented in this catalogue are with fixed cable. Their advantages in This is the point of union between the sample and the electrolyte. This is the most front of the classic screw cap electrodes are: critical part of the electrode as it has a direct influence on the electrode life-span. - The electrode replacement guarantees the cable substitution, which is normally A wide range of s are available. They vary according to manufacturer, weary by the use. application, quality and price. This catalogue features electrodes with - The cost of the electrode is less than the equivalent with screw cap. ceramic, large porous PTFE s, sleeve and open s. The ceramic is a porous, chemically inert Body plate. This is the traditional. It allows little Normally in glass. For applications requiring robustness, the electrodes electrolyte flow towards the sample. are manufactured with a plastic body or stainless steel. The PTFE ring consists of a large porous PTFE ring through which contact between the electrolyte and the Reference sample is made. It guarantees a large contact surface, This is a cell that supplies a stable potential (mv). Various with hardly any change in the level of conductivity of the types are available: sample. This has to do with the reduced flow of electrolyte Silver wire (Ag) provided by these electrodes, thanks to their gel elec- Galvanically coated with AgCl. This is the typical trolyte. for low-cost electrodes. The sleeve consists of a hole in the body of Sleeved silver wire the electrode, half-closed by a movable PTFE ring. Its It consists of silver wire coated with AgCl and protected inside main features include a high electrolyte flow and a tube. The is protected from possible alterations that cannot be blocked. It cannot withstand that may occur in the electrolyte. temperatures exceeding 60ºC. Encapsulated AgCl crystals, cartridge The open, which should really be called The silver wire comes into contact with a portion of Ag/AgCl crystals without, is actually a hole in the body of inside a small glass tube. This system ensures the the electrode which allows the electrolyte to come into best stability and longest lifespan. direct contact with the sample. There is no electrolyte Cartridge with Ag+ ion barrier flow. It is only used in electrodes with solid electrolyte. In some electrodes, the tube with Ag/AgCl is lengthened to Two types of open s are available: house a chemical substance which acts as a barrier to silver - Lateral orifice in the body of the electrode. ions. This prevents the from clogging due to the - Circular. Ring-like groove between the main body, formation and precipitation of AgCl and Ag 2 S. the indicator electrode and the electrode. It allows maximum contact with the sample. Reference electrolyte This is a highly-concentrated saline solution into which the Glass membrane is submerged. It comes in 3 forms: liquid, gel or solid The composition of the glass membrane affects characteristics such as (polymer). sensitivity, chemical, thermal and mechanical resistance and the scale of Gel electrolyte. Used in nonrefillable, low-maintenance electrodes. measurement. There are specific types of glass e.g. to measure ph in the Most are glycerade gels. presence of certain concentrations of HF, at extremely low or high Solid electrolyte. Used in nonrefillable electrodes. Made of a temperatures (i.e. -30ºC or 100 C). The shape of the membrane also conducting polymer. varies. It could be cylindrical, spherical, flat, pointed or micro Liquid electrolyte. Used for refillable electrodes. The electrode response depends directly on the quality of the There are various types: membrane. CRISOLYT A, KCl 3M saturated with AgCl. This electrolyte is used in electrodes with of Ag / AgCl wire. Temperature sensor (T) CRISOLYT, KCl 3M. For electrodes with of encapsulated The new CRISON electrodes, T version, incorporate a temperature AgCl crystals. sensor, type Pt 1000 class B, inside their membrane. In this way ph and CRISOLYT G, KCl + Glycerine. For electrodes with temperature are measured at the same point. This is the most suitable encapsulated AgCl crystals, suitable for measuring in samples with high way of ph measurement, according to GLP and ISO. protein content, partially organic samples containing oils or at low ContATC system, (patented). (see scheme) temperatures. LiCl 1M in Ethanol. For titrations in non-aqueous media. T In the high performance laboratory models, the Pt 1000 sensor is in direct contact with the membrane and is immersed in thermo-conductive silicone. Hence a ph electrode with ContATC system can be used as a precision ContATC system temperature probe. ph, redox and I.S.E. electrodes 3
4 Practical considerations in the ph measurement ph range The ph measuring range of an electrode depends on the glass membrane composition and on the system. The majority of CRISON electrodes cover the ph range from 0 to 14. The electrodes with solid electrolyte cannot be used for ph values under ph 2. Temperature range On the CRISON electrode s body it is indicated the temperature interval at which can be used. Occasionally they can measure at slightly higher temperature than the indicated but never in continuos way. If usually the measurements are at high temperature, for example 80ºC, it is recommended to use an electrode resistant up to 100ºC because its duration will be longer. The binomial ph - temperature The effects of temperature in measuring ph are:... on the electrode Nernst s Law says that the electrode slope varies according to temperature in a predictable manner. ph-meters automatically compensate for this effect with Automatic Temperature Compensation. To do this, the temperature of the sample must be given to the instrument. This can be done by: Connecting a temperature sensor to the ph-meter, in addition to the electrode. Using an electrode with a built-in temperature sensor, the main advantage of this being that it makes handling easier. The two signals ph and temperature are transmitted to the instrument using a single sensor and a single cable. Manually entering the temperature. In some applications, temperature does not need to be measured, either because the temperature is constant or because a broad ph value is acceptable, etc. In these cases, the temperature of the sample can be entered manually using the keypad on the instrument.... on the buffer solutions Temperature makes every solution behave in a certain way. CRISON ph-meters have a built-in table of the ph values of buffer solutions at various temperatures to obtain perfect calibration at any temperature.... on a given sample Temperature makes the ph of the products vary in different ways, and the instrument cannot compensate for this variation. Therefore, the ph value and the temperature at which the measurement was taken must always be reported together. Under normal working conditions, a ph-meter with automatic temperature compensation allows calibrating at ambient temperature and measuring at different temperatures. Nevertheless, if very high precision is required, the buffer solutions used in the calibration and the sample must be at the same temperature or the isopotential point of the electrode must be determined. Isopotential, phiso (isoph) Potential (mv) of a ph electrode that does not vary with the temperature. This is the intersection of the calibration lines obtained at different temperatures. Normally it is accepted that this value corresponds to ph 7. In fact, this value is slightly different. With the new CRISON ph-meters GLP+, the phiso can be adapted to the electrode in use. Minimum sample volume This will depend on the shape of the receptacle and the electrode used for the measurement. When the sample volume is very small, it is recommended to carry out the measurement in a test tube and / or to use a micro electrode. Immersion depth of the electrode To obtain a correct measurement of the ph, the electrode must be immersed at least until the is covered (fig A). If the sample temperature differs from ambient temperature, it is necessary to immerse the electrode until the temperature sensor and the are covered. In this way, fast and precise measurements will be obtained (fig B). A B Storage The electrode must always be stored in the protective sleeve with some of the corresponding electrolyte solution. It can be done easily using the CRISON storage protector. The CRISON storage protector improves 3 main concepts with regard to the classic protectors : In the electrodes for the - easy use thanks to the screw. portable ph-meter, the - an o-ring completely seals the protective sleeve to protector screws directly avoid electrolyte spillage (white crystallization). on the handle. - it prevents over-pressures on the electrode, that in some cases could quickly obstruct the. Electrode life expectancy The average life expectancy of a ph electrode is approximately 1 year. This period of time depends on the quality and use: number of samples to measure, measurements at the extremes of the ph scale, temperature and maintenance of the electrode. If your electrode has a shorter life-span, please enquire; you could be using the incorrect electrode! Electrodes exposed to high temperatures or very alkaline media do not last as long. To avoid accidental breakage of the electrodes with glass body, the use of a working protector is very useful. The CRISON working protector, made of polypropylene, is screwed to the electrode and protects it against knocks during use. Quality-price ratio The quality of the electrode has a direct bearing on the reliability of measurement. CRISON only supplies top quality electrodes because experience has proven these to be a better investment in the medium and long-term. Guarantee CRISON electrodes are guaranteed for a six-month period. The guarantee only covers manufacturing defects. 4 ph, redox and I.S.E. electrodes
5 ph electrodes. Application table Sector Application Portable Laboratory Comments Water In general / Low conductivity The must ensure big contact between electrolyte and sample. Waste water Electrodes with clog-resistant. Agriculture Irrigation water Soils Soils with low level of salts Food Soft drinks The electrodes recommended for the food industry require a special electrolyte, Cacao and derivatives CRISOLYT G, because this type of sample normally contains high levels Meats, hams, delicatessen meats * of proteins. In some cases an electrode with a clog-resistant may be necessary. In general, all these electrodes must be regenerated periodically with an electrode-cleaning solution with pepsin. Beer Fruits and vegetables * Point-shaped membrane electrodes are appropriate where puncture measurements Milk / are taken. Butter, yoghourt and ice-cream / Cheese * Bread dough * Wine, musts and vinegars / Juices and canned vegetables Brine / / Biology and Agar * / for surfaces , semi-liquid samples. Pharmacy Small volume of sample * / Colouring Colourings and dyes The electrode must be cleaned immediately after measure For variable or high temperatures use Cosmetics Creams / These will normally be viscous samples, or samples with ions which may react Gels, emulsions and soaps / with the Ag+ ion. As a result, electrodes with an Ag+- free electrolyte and clogresistant Skin * are best. Fur Leather * Electrodes with flat membrane. Treatment baths Electrodes with clog-resistant. Education Practices / Photography Baths Galvanic Baths 50 50/ Paper Paper, cardboard and fibres * Electrodes with flat membrane. Paper pulp or paste Dark lyes Paint Paint, varnish, emulsions After measure, clean the electrode immediately. Resins Natural (latex, etc) and synthetic * Electrodes with sleeve. Textile Fabrics and prints * Electrodes with flat membrane. Dyes and colourings Electrodes with clog-resistant. University Research * High alkalinity samples * Detergent, Soaps Solutions containig HF * HF attacks glass, do not exceed the limit for HF concentration.. Gels for electrophoresis * Electrodes with flat membrane. Solutions with proteins / Requires CRISOLYT G as electrolyte. Solutions with sulphides * Ag+ free electrolytes should be used. The electrodes with silver ion barrier are the best. Flat, laminate, rough surfaces * A drop of distilled water must be used to ensure contact. Preparation of buffers The TRIS buffers require big-contact s. TRIS Temperatures higher than 80 C Low temperatures, up to -10 C * Acid-base titration in aqueous media * Choose the electrode in accordance with the sample s type. Acid-base titration in food * / Non-aqueous electrolyte is required for anhydrous media. Acid-base titration in non-aqueous media * (LiCl) * Ask for screw cap electrode range. ph, redox and I.S.E. electrodes 5
6 Electrodes for CRISON portable PH 25 These are fixed-cable electrodes with a plastic MP-5 connector, gold-coated contacts and IP 67 protection. Ergonomic and robust, designed for taking measurements in the field. The electrode can be adequately held without harming the cable. All electrodes are low-maintenance. The internal electrolyte inside the membrane is gel preventing the air bubble formation. Every model has a version with integrated temperature probe = T. Details: Gel electrolyte (non-refillable) Wire Universal T Low Cost ph electrode. The plastic body protects the membrane against knocks. Measurements in aqueous samples in general. Low-conductivity, dirty or viscous solutions. Products with colloids or solids in suspension. Samples containing sulphides, reducing sugars or other substances which react with the silver ions. Temperatures exceeding 80 ºC. Organic solvents. With open T As a result of the co-operation with experts in ph, an idea for harsh conditions - resistant electrode was born. An electrode with excellent results has been created. The is the version of this electrode for portable instrument. Milk, juices,... food products in general. Very dirty waste water. Samples with ph < 2. Distilled water. Temperatures higher than 80 ºC. They are supplied with polypropylene working protector preventing accidental breakage of the electrode Polymer electrolyte Sleeved 1 m Open, annular Gel electrolyte (non-refillable) Sleeved Porous PTFE Polymer electrolyte Stainless steel coating Working protector Open Gel electrolyte (non-refillable) Wire Ø 12 Platinum wire Gel electrolyte (non-refillable) Titanium electrodes Wire T Temperature sensor a=85 Specifications T T Electrode code T T Measuring range 0 14 ph 2 14 ph Operating temperature (ºC) 0 80 C 0 80 C Reference Ag wire sleeved Ag wire Diaphragm ceramic open circular Electrolyte gel solid Body material interior glass / exterior polycarbonate (PC) glass 6 ph, redox and I.S.E. electrodes
7 For difficult samples T The large annular porous PTFE of these electrodes assures the optimum contact between electrolyte and sample. Measurements in difficult samples, creams, dirty or viscous samples. Measurements at high temperature up to 100 ºC. Particularly recommended for measuring distilled water. They are supplied with a working protector to avoid accidental breakage. Puncture, stainless steel body T The most robust puncture electrodes. Unique on the market: Stainless steel external body. Can measure with the membrane in any position. With built-in temperature probe, T. A single puncture is sufficient to measure ph and temperature and to compensate for the temperature effect on the ph measurement. Measurements in semi-solids: cheeses, meats, fish, fruits, bread dough, etc. These electrodes can also be used for measurements in aqueous samples. ph < 2. Temperatures exceeding 60 ºC For redox measurements Platinum electrode for oxide-reduction potential (ORP) measurements in aqueous samples. Chemical waste water treatment, galvanic baths, etc. Temperatures higher than 80 ºC. MULTISENSOR FOR MM Developed to measure with CRISON portable MM 40. Composed by one ph electrode, one conductivity cell and one temperature probe, all in one body. Agriculture: irrigation water, hydroponic culture, etc. Industry: process water, gas scrubbing towers, etc. Education: laboratories at school. Dirty/viscous samples. Conductivity > 30 ms/cm. Multisensor, exclusive for MM 40. Working protector Ø 5 Ø 6 T T T T T ph 2 14 ph ± 2000 mv 0 14 ph, µs/cm C 0 60 C 0 80 C 0 80 C sleeved Ag wire cartridge Ag wire Ag wire anular of porous PTFE 1 ceramic + 1open 1 ceramic 1 ceramic gel solid gel gel glass interior glass / exterior stainless steel 316 glass / PC glass / titanium / PC ph, redox and I.S.E. electrodes 7
8 Electrodes for laboratory ph-meters A selection of five electrodes covering 90% of the ph measurement applications. Two low maintenance models, without electrode re-filling. The rest ot them with liquid electrolyte. Details: Gel electrolyte (non-refillable) Polymer electrolyte (non-refillable) Wire Sleeved Open Low Cost T Low maintenance electrodes. The plastic body protects the membrane against knocks. Measurements in aqueous media in general. Low conductivity, dirty or viscous samples. Products with colloids or solids in suspension. Samples containing sulphides, reducing sugars or other substances which react with the silver ion. Temperatures exceeding 80ºC. With open T With solid electrolyte (polymer conductor). The open around the membrane facilitates the measuring in some media where other electrodes have certain difficulties. This is the laboratory version of an electrode used in the industry with great success. The improvements in front of the classic are no electrolyte consumption, easier to use, clean and store. Food, viscous media, dirty samples, etc. Samples with ph < 2. Temperatures exceeding 80 C. Distilled water Electrolyte: Crisolyt Diaphragms 2, ceramic Silver ion barrier Encapsulated 1 m Electrolyte: Crisolyt G Diaphragms 3, ceramic Encapsulated s has 2 equal s, placed close to the sample. It improves the response time with temperature variation. 0.1 Sample at 25 C Change at 50 C Conventional electrode Ø 12 minutes Electrolyte: Crisolyt Sleeved a=130 ph electrode + T System ContATC (patented). T T T = Temperature sensor Specifications Electrode code T T Measuring interval 0 14 ph 2 14 ph Working temperature 0 80 C 0 80 C Reference Ag wire sleeve Ag wire Diaphragm ceramic open circular Electrolyte gel solid Body material interior glass / exterior polycarbonate (PC) glass 8 ph, redox and I.S.E. electrodes
9 High performance T They offer better performance compared with other similar electrodes due to their membrane, encapsulated system with silver ion barrier and the two s. For aqueous media in general. Suitable for samples containing sulphurs, reducing sugars or other substances which react with silver ions. Viscous solutions or with colloids. High Tech T The most robust laboratory electrode against high alkalinity and temperature (special membrane HA). Fast response to temperature changes. Three s ensure stable electrolyte flow. Crisolyt G, an electrolyte with glycerine, avoids the reaction between KCl and proteins. Samples with proteins. Measurements with rapid changes in temperature and/or highly alkaline samples. The perfect electrode for investigation. Viscous solutions or products with colloids. For difficult samples T The sleeve is impossible to be clogged and ensures high electrolyte flow. Electrode suitable for the most difficult samples. Samples with very low conductivity, e.g. distilled water. Samples with colloids, wines, paint, etc. Very viscous samples, emulsions, creams, etc. Samples with temperatures exceeding 60 C. T T T T T T 0 14 ph 0 14 ph 0 14 ph C C 0 60 C cartridge with Ag + barrier cartridge with Ag + barrier cartridge with Ag + barrier 2 ceramic 3 ceramic sleeve CRISOLYT CRISOLYT G CRISOLYT glass glass glass ph, redox and I.S.E. electrodes 9
10 Special ph electrodes For applications that require some special feature of the electrode. For example, small sample amount, solutions containing hydrofluoric acid, etc. Details: Electrolyte CRISOLYT Membrane resistant to HF A drop of distilled water makes easy the measurement. Encapsulated PTFE Flat membrane Sample For samples with HF The membrane is resistant to HF in the conditions shown in the table. Higher content or at ph@20ºc F - limit lower ph values the ppm membrane is destroyed ppm in very short period of ppm time. 5 without limit For flat surfaces Its main characteristic is that its and the membrane are on the same plane. Paper, fabric, leather, agar, leaves, etc. For microsamples 50 28, Ø , Ø 6 Electrodes suitable to measure ph in very small sample volumes. The can measure in volumes from 100 µl. Biology and clinics. Fragile, especially During measurements the should be covered. 1 m During measurements the should be covered / 57 / 58 Gel or liquid electrolyte Platinum wire Ø 12 I.S.E. WITHOUT internal electrolyte Solid state membrane, crystalline or polymeric a=130 Ø 3 a= Ø Internal electrolyte, gel Internal Salt bridge 70 External electrolyte, lithium acetate Big ceramic Specifications Electrode code Measuring interval 1 11 ph 0 14 ph 0 14 ph Working temperature 0 80 C 0 80 C 0 80 C Reference cartridge cartridge Diaphragm ceramic anular in PTFE ceramic Electrolyte CRISOLYT CRISOLYT CRISOLYT Body material glass glass glass 10 ph, redox and I.S.E. electrodes
11 Redox, I.S.E. and electrodes For redox measurements 50 56, gel , micro Platinum electrodes for oxide-reduction potential (ORP) measurements in aqueous samples in general is a low maintenance electrode and does not require electrolyte refilling. Oxide-reduction titration. Measurements in galvanic baths, etc. Temperature exceeding 80 C. Ion Selective Electrodes 96 50, 96 51, 96 52, etc. New range of electrodes of the latest technology. Compact electrodes without maintenance. Without internal electrolyte nor spare membranes. New more sensitive and long-lasting membranes than the classic ones. With fixed cable and BNC connector. Important: The I.S.E. electrodes are indicator and for measurements require a electrode. Code Ion Meas. interval Conditions Na mg/l 23 g/l ph Br mg/l 80 g/l ph Cl - 1 mg/l 35 g/l ph CN mg/l 0.26 g/l ph I mg/l 130 g/l ph 2 12 Ag mg/l 100 g/l ph 1 9 S mg/l 32 g/l ph F mg/l 20 g/l ph Cu mg/l 64 g/l ph Cd mg/l 11g/l 1 ph Ca mg/l 4 g/l ph K mg/l 39 g/l ph NO mg/l 62 g/l ph NH mg/l 1.8 g/l ph NO mg/l 460 mg/l ph Reference electrode Features: Internal gel electrolyte, difficult to contaminate. It is supplied with lithium acetate as electrolyte in the salt bridge. This is the suitable electrode for all CRISON I.S.E. electrodes. Big ceramic, easily dismounted. This electrode can be used for general applications too. Spare Part , ceramic. Ø 6 a= ± 2000 mv C 0 80 C cartridge cartridge + salt bridge ceramic big ceramic gel (non-refillable) CRISOLYT CRISOLYT lithium acetate glass glass / silicone ph, redox and I.S.E. electrodes 11
12 Other sensors: for E.C., D.O., etc. Código 072-E, Edición Abril 2008 Authorised CRISON dealer: Sensors manufactured under specifications and design of CRISON INSTRUMENTS, S.A.
Compact ph Measuring Instruments
testo 205, 206, 230 Compact ph Measuring Instruments With innovative probe engineering ph C The new ph measuring instruments with innovative probe engineering Measurement of the ph value plays an important
ph Measurement and Control
ph Measurement and Control Tech Tip #14 1997 I. The Need for ph II. ph System Requirements III. ph Electrode Conditioning Procedures IV. How the electrode works V. Identifying the Electrode Components
SenTix 950 SenTix 980
SenTix 950 SenTix 980 ph combination electrodes with refillable liquid reference system Operating manual ba75843e01 08/2009 SenTix The latest version of the present operating manual can be found on the
ELECTROCHEMISTRY. Theory and Practice
ELECTROCHEMISTRY Theory and Practice Dr. Axel Bier Lab Product Application Manager - Electrochemistry For more information, please visit: www.hach.com/smartprobes P a g e 2 CONTENT INTRODUCTION 3 HOW TO
Conductivity and TDS Meters
Table of Contents Comparison Charts Introduction Portable Meters Waterproof Meters Printing & Logging Portable Meters Bench Meters Combination EC/TDS/pH Meter Page G2 G3 G6 G11 G14 G15 G16 G1 Comparison
Resolution selectable from 0.01 and 0.001 ph. Range -2.000 16.000 ph. Accuracy ± 0.002 ph
ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or
JUMO tecline HD ph and JUMO tecline HD Rd
Page 1/7 JUMO tecline HD ph and JUMO tecline HD Rd ph and redox combination electrodes in glass shaft version Series 201021 ph electrodes Series 201026 redox electrodes Brief description JUMO tecline HD
ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:
BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data
CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor
CONDUCTIVITY SENSOR Description D0382 Figure 1. The Conductivity Sensor Short Description The Conductivity Sensor can be used to measure either solution conductivity or total ion concentration of aqueous
Ion Selective Electrodes
Ion Selective Electrodes OAKTON has a large selection of Ion Selective Electrodes () to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary
Milwaukee USER MANUAL
Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the
JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor
Vorläufig V Page 1/8 JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor Cell constants K = 0.01 1.0 202922 Series for universal application, e.g. drinking and surface water monitoring,
Portable digital microprocessor thermometers with interchangeable probes
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: [email protected] Internet: www.jumo.net
Handbook. Thermo Scientific. ph Electrode Selection Handbook
Handbook Thermo Scientific ph Electrode Selection Handbook Table of Contents ph Theory... 4 ph Electrode Theory... 4 ph versus Temperature Theory... 5 ph Electrode Selection Guide... 6 Thermo Scientific
Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01
Milwaukee Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: SM600 Smart DO Meter Authorized Dealer: ISMIL600 11/01 PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery
Features, Limitations & Potential Errors
MINIMIZING USER ERRORS IN ph MEASUREMENTS Features, Limitations & Potential Errors of the Tools of ph Measurements Advanced Sensor Technologies, Inc. 603 North Poplar Street Orange CA 92868-1011 USA General
A Potentiometric Analysis of Fluoride Ion in Toothpaste
CHEM 311L Quantitative Analysis Laboratory Revision 2.0 A Potentiometric Analysis of Fluoride Ion in Toothpaste In this laboratory exercise, we will analyze a toothpaste sample for its Fluoride Ion (F
HND-R. Hand-held ph, Redox and Temperature Measuring Units
Hand-held ph, Redo and Temperature Measuring Units measuring monitoring analysing HND-R A1 P? OMeasuring O range: ph: 0.00...14.00 Redo (ORP): -1999 mv... +2000 mv Temperature: -5 C...+150 C rh: 0.0 rh...
Dissolved Oxygen Sensors
Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit
Ion-selective Measurements
Ion-selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and
Additional Lecture: TITRATION BASICS
Additional Lecture: TITRATION BASICS 1 Definition and Applications Titration is the incremental addition of a reagent solution (called titrant) to the analyte until the reaction is complete Common applications:
Combination ph/redox (ORP) Sensors
Data Sheet SS/AP00 Issue 4 Combination ph/redox (ORP) Sensors AP00 Series Long life large PTFE junction provides resistance to fouling double junction with gelled electrolyte provides better-defined junction
OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S
Pen type, separate electrode SOIL PH METER Model : PH-220S Your purchase of this SOIL PH METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and
Chapter 6. Solution, Acids and Bases
Chapter 6 Solution, Acids and Bases Mixtures Two or more substances Heterogeneous- different from place to place Types of heterogeneous mixtures Suspensions- Large particles that eventually settle out
Pressure Dew Point Probe 0636.9840 / 0636.9841 Application Information
Pressure Dew Point Probe 0636.9840 / 0636.9841 Application Information en Contents Instrument description...3 User instructions...4 Safety instructions...5 Folding ferrite...5 Operating instructions...6
DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters
ELMETRON meters Robust and reliable pocket tester or computerized laboratory equipment Excellent friendly priced quality for research, education and process control 2 DPST-ELMETRON-meters You need a robust,
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
Measurement by Ion Selective Electrodes
Measurement by Ion Selective Electrodes Adrian Vazquez May 8, 2012 Why Use Ion Selective Electrodes? Responsive over a wide concentration range Not affected by color or turbidity of sample Rugged and durable
OxyGuard. Dissolved Oxygen Probe
OxyGuard Dissolved Oxygen Probe Standard type USER MANUAL D02 Standard Probe manual gb 0903 CONTENTS 1. DESCRIPTION 1.1 The OxyGuard Probe... 1 1.3 Which kind of transmitter can be used with the OxyGuard
Galvanic cell and Nernst equation
Galvanic cell and Nernst equation Galvanic cell Some times called Voltaic cell Spontaneous reaction redox reaction is used to provide a voltage and an electron flow through some electrical circuit When
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
Galvanic Cells. SCH4U7 Ms. Lorenowicz. Tuesday, December 6, 2011
Galvanic Cells SCH4U7 Ms. Lorenowicz 1 Electrochemistry Concepts 1.Redox reactions involve the transfer of electrons from one reactant to another 2.Electric current is a flow of electrons in a circuit
UltraBasic Benchtop ph Meter Operation Manual
UltraBasic Benchtop Meter Operation Manual UB-5 Denver Instrument Measuring 4 4 7 10 Meter 22.2 C 4.06 UltraBasic 902388.1 Rev. A UltraBasic Meter Quick Reference 1. Connect a AC adapter to the power connection.
REDOX AND REFERENCE ELECTRODE USER MANUAL
REDOX AND REFERENCE ELECTRODE USER MANUAL 3 Redox and reference electrode manual Copyright 2012 Unisense A/S Version October 2012 REDOX AND REFERENCE ELECTRODE MANUAL UNISENSE A/S TABLE OF CONTENTS WARRANTY
User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending
User Guide ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens Patent Pending Getting Started Remove the cap from the bottom of the ExStik TM to expose the electrode bulb and reference
the importance of ph in water purification the importance of ph in water purification Water Purification Systems UK
the importance of ph in water purification Water Purification Systems UK What is ph? The ph scale has been in use for over a century, ever since it was first defined in 1909 by the Danish chemist, Søren
QUALANOD SPECIFICATIONS UPDATE SHEET Nº 9 Edition 01.07.2010 22.11.11 page 1/5 COLD SEALING PROCESS
page 1/5 COLD SEALING PROCESS Proposal QUALITAL QUALANOD resolution: Meeting in June 2010, October 2011 Date of application: 1 January 2012 Parts of the Specifications concerned: Section 3.3.6 furthermore
DISSOLVED OXYGEN METER Model : DO-5509
DISSOLVED OXYGEN METER Model : DO-5509 Your purchase of this DISSOLVED OXYGEN METER marks a step forward for you into the field of precision measurement. Although this DISSOLVED OXYGEN METER is a complex
Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC
Common Problems with Online Water Quality Analyzers Greg Macy Director AquatiPro LLC Objectives Diagnosing Colorimetric Analyzers Identifying Common Problems with Sodium Analyzers Troubleshooting ph Analyzers
Instruction Manual HI 9146. Portable Waterproof Microprocessor Dissolved Oxygen Meter
Instruction Manual HI 9146 Portable Waterproof Microprocessor Dissolved Oxygen Meter w w w. h a n n a i n s t. c o m Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction
Chapter 13: Electrochemistry. Electrochemistry. The study of the interchange of chemical and electrical energy.
Chapter 13: Electrochemistry Redox Reactions Galvanic Cells Cell Potentials Cell Potentials and Equilbrium Batteries Electrolysis Electrolysis and Stoichiometry Corrosion Prevention Electrochemistry The
Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE
Sodium DOC316.53.01240 Direct ISE Method Method 8359 10 to 1000 mg/l Na + Sodium ISE Scope and application: For drinking water and process water. Test preparation Instrument-specific information This procedure
The Theory of ph Measurement
Application Data Sheet ADS 43-002/rev.C November 2010 Theory The Theory of ph Measurement ph measurement has a wide variety of industrial applications in virtually every industry. These range from water
Compact Water Quality Meter B-700 series
Compact Water Quality Meter B-700 series Actual Size Compact Water Quality Meter Debut! HORIBA s 60 years of sensor engineering realize accurate direct measurement from only a single drop on the unique
Chemistry 51 Chapter 8 TYPES OF SOLUTIONS. A solution is a homogeneous mixture of two substances: a solute and a solvent.
TYPES OF SOLUTIONS A solution is a homogeneous mixture of two substances: a solute and a solvent. Solute: substance being dissolved; present in lesser amount. Solvent: substance doing the dissolving; present
The Effects of Temperature on ph Measurement
The Effects of Temperature on ph Measurement Authors: John J. Barron Colin Ashton & Leo Geary Technical Services Department, Reagecon Diagnostics Ltd, Shannon Free Zone, County Clare, Ireland Abstract
105 Adopted: 27.07.95
105 Adopted: 27.07.95 OECD GUIDELINE FOR THE TESTING OF CHEMICALS Adopted by the Council on 27 th July 1995 Water Solubility INTRODUCTION 1. This guideline is a revised version of the original Guideline
Properties of Acids and Bases
Lab 22 Properties of Acids and Bases TN Standard 4.2: The student will investigate the characteristics of acids and bases. Have you ever brushed your teeth and then drank a glass of orange juice? What
white paper reviews why the chlor-alkali process is so damaging to ph electrodes and discusses a sensor design that has
INGOLD White Paper Leading Process Analytics No More Tears Elevated temperatures, presence of chlorine and high salt concentration throughout the chlor-alkali process make stable and reliable ph measurement
Operating Instructions
Operating Instructions FiveEasyPlus ph meter FEP20 Contents Contents 1. Introduction 3 2. Safety measures 3 3. Installation 4 3.1 Installing the electrode arm (optional for FEP20) 4 4. Operating the FiveEasyPlus
MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL
MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL 430 350/REV A/10-03 MODEL 430 PORTABLE ph/conductivity METER OPERATING MANUAL CONTENTS Introduction 1 Specification 2 Installation 3 Displays 3-4
DNA SPOOLING 1 ISOLATION OF DNA FROM ONION
DNA SPOOLING 1 ISOLATION OF DNA FROM ONION INTRODUCTION This laboratory protocol will demonstrate several basic steps required for isolation of chromosomal DNA from cells. To extract the chromosomal DNA,
Chemistry B11 Chapter 6 Solutions and Colloids
Chemistry B11 Chapter 6 Solutions and Colloids Solutions: solutions have some properties: 1. The distribution of particles in a solution is uniform. Every part of the solution has exactly the same composition
Care and use guide. Contents. a handy solution made easy. www.getbluelab.com. page
Care and use guide Contents page Features Quick guide Before use To operate Important - ph pen probe care 4 Cleaning 5 Battery replacement 5 Hydration 6 Calibration 6 Error messages 7 Troubleshooting guide
Acids, Bases, and ph
CHAPTER 9 1 SECTION Acids, Bases, and Salts Acids, Bases, and ph KEY IDEAS As you read this section, keep these questions in mind: What properties do acids have? What properties do bases have? How can
InLab Sensors. ph ORP Conductivity Ion Concentration Dissolved Oxygen. Origin of Precision Proven Sensor Technology for Safe Results
InLab Sensors InLab Sensors ph ORP Conductivity Ion Concentration Dissolved Oxygen Origin of Precision Proven Sensor Technology for Safe Results Experience & Innovation InLab Sensors Developed for Your
General Purpose ph/orp Sensors
General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL
EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue February 2004 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element 3 1.3 Calibration
MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL
MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL 970 350/REV A/10-03 MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL CONTENTS Introduction 1 Specification 1 Installation 2 Displays 2-3 Controls 4 Preparation
A Useful Tool for the Determination of Consistency in Semi-Solid Substances
A Useful Tool for the Determination of Consistency in Semi-Solid Substances By Wayne S. Goldenberg, Ph.D. and Raj Shah, Ph.D. Koehler Instrument Company, Inc., New York Consistency (i.e., thickness or
Care and use guide. Contents. page
Care and use guide Contents page Features Bluelab Combo Meter Introduction Preparing for use Calibration Changing nutrient and temperature display units 6 Measuring hydroponic elements 7 Battery replacement
CYCLE CHEMISTRY ph MEASUREMENT
CYCLE CHEMISTRY ph MEASUREMENT David M. Gray and Edward P. Santini Thornton Associates, Waltham MA Electric Utility Chemistry Workshop Champaign, Illinois May 12-14, 1998 Sponsored by University of Illinois
Lab 7 Soil ph and Salinity OBJECTIVE INTRODUCTION Soil ph active
Lab 7 Soil ph and Salinity OBJECTIVE In this lab you will learn the effect of the concentration of hydrogen ions (ph) and various salts on the fertility of a soil. You will perform some tests which are
USEPA Electrode Method Method 8156
ph DOC316.53.01245 USEPA Electrode Method Method 8156 Scope and application: For drinking water 1, wastewater 2 and process water. 1 Based on Standard Method 4500-H+B, ASTM Method D1293-95 and USEPA Method
o Electrons are written in half reactions but not in net ionic equations. Why? Well, let s see.
REDOX REACTION EQUATIONS AND APPLICATIONS Overview of Redox Reactions: o Change in Oxidation State: Loses Electrons = Oxidized (Oxidation number increases) Gains Electrons = Reduced (Oxidation Number Reduced)
This value, called the ionic product of water, Kw, is related to the equilibrium constant of water
HYDROGEN ION CONCENTRATION - ph VALUES AND BUFFER SOLUTIONS 1. INTRODUCTION Water has a small but definite tendency to ionise. H 2 0 H + + OH - If there is nothing but water (pure water) then the concentration
ph Measurements of Common Substances
Chem 100 Section Experiment 10 Name Partner s Name Introduction ph Measurements of Common Substances The concentration of an acid or base is frequently expressed as ph. Historically, ph stands for the
ph 200 ph-/redox-/temperature Meter Operating instructions
ph 200 ph-/redox-/temperature Meter Operating instructions 2 Table of Contents Page 1. Scope of delivery...4 2. System description...4 3. Connections...5 4. Display...7 5. Keypad...7 6. Start up...8 7.
Single-Use Flow-Through Cell ph FTC-SU-HP8
Single-Use Flow-Through Cell ph FTC-SU-HP8 SENSOR PROBES Instruction Manual Single-Use Flow-Through Cell ph FTC-SU-HP8 Specification: ph sensor stick integrated in a single-use flow-through cell Document
EXPERIMENT 20: Determination of ph of Common Substances
Materials: ph paper and color chart (ph range 3 to 12) or ph meter distilled water white vinegar household ammonia (or baking soda) spot plate test or 3 small test tubes stirring rod solutions / fruits
Professional Plus. Calibration Tips
Professional Plus Calibration Tips Table of Contents Introduction...1 Calibration Worksheet...1 Temperature...3 Calibration Tips...3 Troubleshooting Tips...3 Conductivity...4 Calibration Tips...4 Troubleshooting
Quartz Glass. Tubes and Rods
Quartz Glass Tubes and Rods PH 300, GE 214, QI PN GVB Solutions in Glass Schlackstrasse 3 52080 Aachen Germany +49-241/9108588 +49-241/9108589 E- [email protected] www.g-v-b.de Table of contents General Information
A. Types of Mixtures:
I. MIXTURES: SOLUTIONS 1) mixture = a blend of two or more kinds of matter, each of which retains its own identity and properties a) homogeneous mixture = a mixture that is uniform in composition throughout
TurbiDirect TurbiCheck TurbiCheck WL
Turbidity 128 TurbiDirect TurbiCheck TurbiCheck WL www.lovibond.com General Catalogue February 2013 Turbidity measurement The term "turbidity is used to describe the cloudy or milky appearance of liquid
Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature
Eutech 2700 Series Bench Meters ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature Features Comprehensive Backlit Display All Measurements Include Temperature Display Up To 500
Multiple flasks. Easy to adapt. Stuart range of heating blocks
Heating Blocks The Stuart range of heating blocks have been developed in conjunction with DrySyn to provide the best possible solution for heating round bottom flasks. Combined with the Stuart range of
Neutralizing an Acid and a Base
Balancing Act Teacher Information Objectives In this activity, students neutralize a base with an acid. Students determine the point of neutralization of an acid mixed with a base while they: Recognize
Troubleshooting Salt Generators
Troubleshooting Salt Generators NOTE Turn off power to unit prior to attempting service or repair. Problems and Corrective Action Problem Possible Cause Corrective Action Low or no chlorine. Low stabilizer
Stainless Steel Dissolved Oxygen Electrodes
Stainless Steel Dissolved Oxygen Electrodes DISSOLVED OXYGEN ELECTRODES The steam sterilizable family of dissolved oxygen electrodes from the phoenix Electrode Company is specifically designed for fermentation
Non- Carbon Fiber Electrical Heating Textile Introduction:
Non- Carbon Fiber Electrical Heating Introduction: This Heating is a new generation electrical heating system which is specially designed for mobile heating, energy saving and safety orientated requirements
An Ammonium-free, Acid. Zinc/Nickel (12-15% Ni) Process
An Ammonium-free, Acid Zinc/Nickel (12-15% Ni) Process Requirements of an acid zinc/nickel process Technical requirements High plating speed (current efficiency up to 90 %) High thicknesses of deposits
INSTRUCTIONS 56-1190-98. Edition AC
Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography
ExStik TM ph Waterproof Meters
User Guide ExStik TM ph Waterproof Meters Models PH100 & PH110 Patent Pending ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE / HOLD button 4. CAL / RECALL
General Purpose ph/orp Sensor
Instruction Sheet General Purpose ph/orp Sensor Sensors LIQ_MAN_ABR_3900 October 2014 General Purpose ph/orp Sensor Specifications Figure 1. 3900 Insertion/Submersion Sensor Sensor Type: General purpose
Portable Density/Specific Gravity/Concentration Meter DMA 35
Portable Density/Specific Gravity/Concentration Meter DMA 35 DMA 35 Density Measurement on the Move DMA 35 is the new generation of Anton Paar portable density meters, using the oscillating U-tube technology.
Practical Lesson No 4 TITRATIONS
Practical Lesson No 4 TITRATIONS Reagents: 1. NaOH standard solution 0.1 mol/l 2. H 2 SO 4 solution of unknown concentration 3. Phenolphthalein 4. Na 2 S 2 O 3 standard solution 0.1 mol/l 5. Starch solution
Nickel Free Room Temperature Seal: an innovative and ecological process
Nickel Free Room Temperature Seal: an innovative and ecological process 2015 ANODIZING CONFERENCE San Diego, California Prepared by: Marcello Rossi Italtecno Srl Italy NICKEL FREE ROOM TEMPERATURE SEAL:
Warranty. www.tissot.ch 1/5. Warranty
Warranty Warranty Your TISSOT watch is warranted by TISSOT S.A. for a period of twenty-four (24) months from the date of purchase under the terms and conditions of this warranty. The international TISSOT
Acetic Acid Content of Vinegar: An Acid-Base Titration E10-1
Experiment 10 Acetic Acid Content of Vinegar: An Acid-Base Titration E10-1 E10-2 The task The goal of this experiment is to determine accurately the concentration of acetic acid in vinegar via volumetric
Model 2128 AIR COMPRESSOR PUMP Operating Instructions
Model 8 AIR COMPRESSOR PUMP Operating Instructions Assembly of pump Connection to cylinder and charging ) Connect the air hose to the air cylinder and tighten with spanner. Do not over tighten. Note; the
PN 44-6033/rev. D December 2010. Theory and Practice of ph Measurement
PN 44-6033/rev. D December 2010 Theory and Practice of ph Measurement THEORY AND PRACTICE OF ph MEASUREMENT TABLE OF CONTENTS THEORY AND PRACTICE OF ph MEASUREMENT TABLE OF CONTENTS Section Title Page
High pressure reactors Where are your limits?
Laboratory equipment High pressure reactors Where are your limits? Modern high pressure reactors need to be technically safe, reliable, economical in use and simple to operate. With Berghof quality and
Experiment 16-Acids, Bases and ph
Definitions acid-an ionic compound that releases or reacts with water to form hydrogen ion (H + ) in aqueous solution. They taste sour and turn litmus red. Acids react with certain metals such as zinc,
Titanium Dioxide Raspberry Solar Cell 2012, 2011, 2005 by David A Katz. All rights reserved
Titanium Dioxide Raspberry Solar Cell 2012, 2011, 2005 by David A Katz. All rights reserved Greg Smestad (http://www.solideas.com/solrcell/cellkit.html) developed this experiment. See the Nanocrystalline
DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech
E D 3 6 & E H D 3 6 DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech CONTENT 1 ENVIRONMENTAL... 5 1.1 SOIL... 5 1.2 WASTE WATER... 6 2 FOOD... 7 2.1 RICE... 7 2.2
ACRYLICS. The properties of the resulting acrylics vary depending on the nature of the alkyl groups both on the alcohol and the acrylic acid.
AYLIS Acrylics are polyesters based on acrylic acid (propenoic acid - H 2 =H 2 H) formed from the polymerisation of an alkyl acrylate ester. They are widely used in the surface coatings industry (e.g.
ph and Acidity in Wine and Fruit Juice
ph and Acidity in Wine and Fruit Juice DOC316.52.93089 Endpoint potentiometric titration Scope and application: Wine and fruit juice 1. Introduction This working procedure refers to the titration of total
Trace Dissolved Oxygen Sensor
Instruction Sheet PN 51A-499ATRDO/rev.G September 2010 Model 499A TrDO Trace Dissolved Oxygen Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION
Handling Corrosive or Abrasive Liquids
Handling Corrosive or Abrasive Liquids Defining abrasion and corrosion An abrasive liquid is one that has particles in it. Some, like inks, have very fine particles, while others, like some paints, contain
5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS
5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS Sl. No. Contents Preamble 5.1 Aim 5.2 Introduction 5.2.1 Environmental Significance 5.3 Principle 5.4 Materials Required 5.4.1 Apparatus Required 5.4.2