TOTAL WATER DISTRIBUTION SYSTEM: $136, $125, $139,302.50

Similar documents
Item No. Description Estimated Unit Total Unit Total Unit Total Unit Total Quantity Price Amount Price Amount Price Amount Price Amount

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

FY08 SEWER POINT REPAIRS BID TABULATION

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Special Specification 7021 Water Main and Sewer Line Replacements

Demo Existing Curb Demo Existing Asphalt Roadway Demo Asphalt Saw Cutting Protection Fence - 4 Snow Fence with T posts

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

VILLAGE OF LOMBARD CONTRACT DOCUMENT NUMBER ST BID PROPOSAL

Unit Price Averages Reports

San Antonio Water System Standard Specifications for Construction ITEM NO POINT REPAIRS AND OBSTRUCTION REMOVALS

WILDCAT CANYON ROAD SPECIFICATION NO SLIDE REPAIR BIDDER'S PROPOSAL (continued)

PROJECT COST ESTIMATE ASSUMPTIONS AND EXCLUSIONS

Los Angeles County Department Of Public Works. Land Development Division. Bond Calculation Sheets

City of Shelbyville Site Inspection Checklist

Storm Drain Inlet Protection - IP

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

SANITARY SEWER SPECIFICATIONS

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

City of Hilshire Village Pine Creek Ln Reconstruction

OSU Extension FACT SHEET

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

Land Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

DESCRIPTION OF WORK:

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

Section 2100-Trenching and Tunneling

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

STORM WATER PROJECT COST ESTIMATES & LOCATION MAPS. Appendix F

Close-Out Documents... 9

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SECTION STORM DRAIN SYSTEM

SECTION STORM DRAINAGE TABLE OF CONTENTS

ARTICLE VI (ALTERNATE) STANDARD SPECIFICATIONS. for (PVC) SANITARY SEWER MAIN CONSTRUCTION

San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Let Us Give Utilities the Respect that they Deserve.

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

C. Section TESTING LABORATORY SERVICE.

A. Structures Quantity Item Price $3,500 EA

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

LS 2540 SEWER LATERALS AND INSPECTION TEES

Helen Mercury Mine EE/CA OPINION OF PROBABLE COST

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

Stormwater/Wetland Pond Construction Inspection Checklist

CLEANING, INSPECTION, AND TESTING OF SEWERS

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST

ADDENDUM NO. 2. Contract Documents for REPLACEMENT OF PHOENIX STREET BRIDGE OVER THE TANKERHOOSEN RIVER VERNON, CONNECTICUT

SECTION GRAVITY SANITARY SEWERS

The Manitoba Water Services Board SECTION Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11

SECTION 7- STORM SEWER

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

SANITARY SEWER PROJECT COST ESTIMATES & LOCATION MAPS. Appendix D

STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION CITY OF MANITOWOC, WISCONSIN SECTION 400 SEWER AND WATER CONSTRUCTION

SE-10 STORM DRAIN INLET PROTECTION. Objectives

City of Balch Springs, Texas. Request for Proposal (RFP ) Pipe Bursting Sewer Line Replacement

BMP-7. A sediment filter or an excavated impounding area around a storm drain drop inlet or curb inlet.

CITY ENGINEERS ASSOCIATION OF MINNESOTA

3. Amend the following: Item 410 Traffic Compacted Surface, Type C to Item 446 Cold Patch.

Exhibit A. Rules and Regulations for House Connections and Sewer Extensions

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

FIBER-OPTIC CABLE PLAN CHECK

UNIT PRICE LIST January 2009

SECTION 3 SANITARY SEWER DESIGN

SECTION STORM DRAINAGE SYSTEM

Specifications for Residential Property Owners Connection to New Public Sewer

Analyzing The Bread & Butter Benefits of Sewer Main Pipebursting. Matt Werth General Manager PM Construction

CITY OF ANN ARBOR PUBLIC SERVICES PLAN REVIEW CHECKLIST

Emerging Technologies in Wastewater Collection Systems

Section 402. STORM SEWERS

STANDARD SPECIFICATIONS SECTION INSTALLATION OF GRAVITY SEWER PIPELINES. 1. Trenching, Backfilling and Compacting: 02223

SECTION SITE PREPARATION

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

Sewage Compliance Form Instructions

Storm Drain Inlet Protection

SECTION 5: SANITARY SEWER SYSTEM DESIGN

FDOT DBE CERTIFICATION NAICS CODE GUIDE WITH CAP SIZES

CHAPTER 6 - SANITARY SEWER

Permeable Pavement Construction Guide

SECTION 603 SANITARY SEWER FORCE MAINS

Figure 3 Pipe Cracking

SECTION SELECTIVE DEMOLITION

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

STORM DRAIN DESIGN AND CONSTRUCTION STANDARDS & SPECIFICATIONS 400 SERIES

SECTION SANITARY SEWER PIPE

Standards for Water, Sewer, and Sewage Lift Station Design

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Table 4.9 Storm Drain Inlet Protetion Applicable for

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

SANITARY SEWER SERVICE CONNECTION INSTRUCTIONS

Transcription:

HARRIS COUNTY UNIT BID TABULATION WATER DISTRIBUTION SYSTEM 1. 16-Inch C-905, PVC Water Line 1,741 LF $30.00 $52,230.00 $28.00 $48,748.00 $32.35 $56,321.35 2. 12-Inch C-900, PVC Water Line 1,124 LF $20.00 $22,480.00 $18.00 $20,232.00 $21.95 $24,671.80 3. 12-Inch C-900, PVC Restrained Joint Water Line (including ductile restrained joint fittings) 60 LF $60.00 $3,600.00 $62.00 $3,720.00 $63.00 $3,780.00 4. 16-Inch Gate Valve with Box 6 EA $4,722.00 $28,332.00 $4,400.00 $26,400.00 $4,445.00 $26,670.00 5. 12-Inch Gate Valve with Box 1 EA $1,440.00 $1,440.00 $1,400.00 $1,400.00 $1,412.00 $1,412.00 6. 6-Inch Gate Valve with Box 7 EA $486.00 $3,402.00 $500.00 $3,500.00 $490.00 $3,430.00 7. Fire Hydrant 7 EA $1,689.00 $11,823.00 $1,500.00 $10,500.00 $1,820.00 $12,740.00 8. 6-Inch C-900, PVC Fire Hydrant Lead 42 LF $10.00 $420.00 $13.00 $546.00 $12.00 $504.00 9. Remove and Dispose of Existing 12-Inch Plug and Clamp and 2-Inch Blow-Off Valve 1 EA $43.00 $43.00 $100.00 $100.00 $25.00 $25.00 10. 12-Inch Wet Connection 1 EA $383.00 $383.00 $300.00 $300.00 $230.00 $230.00 11. 16-Inch Plug and Clamp 4 EA $492.00 $1,968.00 $560.00 $2,240.00 $290.00 $1,160.00 12. 2-Inch Blow-Off Valve with Box Including Check Valve 4 EA $692.00 $2,768.00 $470.00 $1,880.00 $440.00 $1,760.00 13. Ductile Iron Fittings 2.0 TONS $3,070.00 $6,140.00 $2,900.00 $5,800.00 $3,225.00 $6,450.00 14. Trench Safety 2,967 LF $0.54 $1,602.18 $0.05 $148.35 $0.05 $148.35 TOTAL WATER DISTRIBUTION SYSTEM: $136,631.18 $125,514.35 $139,302.50 Page 1 of 8

HARRIS COUNTY UNIT BID TABULATION WATER DISTRIBUTION SYSTEM (SECTION TWELVE) 1. 20-Inch C-906, DR-17, HDPE Water Line Casing (casing pipe only; directional drill) 2. 12-Inch C-906, DR-11, HDPE Water Line in 20-Inch HDPE Water Line Casing (water line pipe only) 711 LF $128.00 $91,008.00 $121.00 $86,031.00 $120.70 $85,817.70 711 LF $32.00 $22,752.00 $30.00 $21,330.00 $34.50 $24,529.50 3. 12-Inch C-900, PVC Water Line 736 LF $19.00 $13,984.00 $19.00 $13,984.00 $20.60 $15,161.60 4. 12-Inch Gate Valve with Box 3 EA $1,440.00 $4,320.00 $1,400.00 $4,200.00 $1,412.00 $4,236.00 5. 6-Inch Gate Valve with Box 2 EA $486.00 $972.00 $480.00 $960.00 $490.00 $980.00 6. Fire Hydrant 2 EA $1,689.00 $3,378.00 $1,500.00 $3,000.00 $1,820.00 $3,640.00 7. 6-Inch C-900, PVC Fire Hydrant Lead 10 LF $11.00 $110.00 $13.00 $130.00 $12.00 $120.00 8. Remove and Dispose of Existing 12-Inch Plug and Clamp and 2-Inch Blow-Off Valve 1 EA $43.00 $43.00 $100.00 $100.00 $25.00 $25.00 9. 12-Inch Wet Connection 1 EA $383.00 $383.00 $270.00 $270.00 $230.00 $230.00 10. 12-Inch Plug and Clamp 1 EA $196.00 $196.00 $300.00 $300.00 $175.00 $175.00 11. 2-Inch Blow-Off Valve with Box Including Check Valve 1 EA $584.00 $584.00 $500.00 $500.00 $440.00 $440.00 12. Remove and Replace of Existing Barb Wire Cattle Fence Located North of Proposed Greenhouse Road Bridge to Original, or Better than Original Condition 50 LF $4.00 $200.00 $3.40 $170.00 $10.60 $530.00 13. Ductile Iron Fittings 1.0 TONS $957.00 $957.00 $920.00 $920.00 $1,600.00 $1,600.00 14. Trench Safety 746 LF $0.54 $402.84 $0.05 $37.30 $0.05 $37.30 TOTAL WATER DISTRIBUTION SYSTEM (SECTION TWELVE): $139,289.84 $131,932.30 $137,522.10 Page 2 of 8

HARRIS COUNTY UNIT BID TABULATION WASTEWATER COLLECTION SYSTEM 1. 15-Inch SDR-26, PVC Sanitary Sewer (all depths) 1,337 LF $62.00 $82,894.00 $66.00 $88,242.00 $80.10 $107,093.70 2. 8-Inch SDR-26, PVC Sanitary Sewer (all depths) 770 LF $39.00 $30,030.00 $49.00 $37,730.00 $36.25 $27,912.50 3. 8-Inch SDR-26, PVC Sanitary Sewer (all depths; bore and jack; including all required and necessary bore pits) 96 LF $47.00 $4,512.00 $240.00 $23,040.00 $51.15 $4,910.40 4. Standard City of Houston 4-Foot Diameter Sanitary Sewer Manhole 5. Standard City of Houston 4-Foot Diameter Sanitary Sewer Manhole with Drop Connection 12 EA $1,564.00 $18,768.00 $1,200.00 $14,400.00 $1,205.00 $14,460.00 1 EA $1,768.00 $1,768.00 $1,600.00 $1,600.00 $1,480.00 $1,480.00 6. Extra Depth for Manhole (over 8-foot deep) 206 VF $59.00 $12,154.00 $57.00 $11,742.00 $79.00 $16,274.00 7. Remove and Dispose of Existing 15-inch SDR-26, PVC Sanitary Sewer Stub and Plug and Connect Proposed 15-Inch SDR-26, PVC Sanitary Sewer Pipe to Existing Sanitary Sewer Manhole 8. Well Point De-Watering for Sanitary Sewer Construction (only as directed by the Engineer; (minimum bid $25.00/LF) 1 EA $88.19 $88.19 $1,100.00 $1,100.00 $110.00 $110.00 2,203 LF $25.00 $55,075.00 $25.00 $55,075.00 $25.00 $55,075.00 9. Crushed Stone Foundation with Filter Fabric Wrap as per City of Houston Detail No. 02317-02 (only as directed by the Engineer; minimum bid $10.00/LF) 10. Crushed Stone Foundation and Embedment with Filter Fabric Wrap as per City of Houston Detail No. 02317-01 (only as directed by the Engineer; minimum bid $25.00/LF) 2,203 LF $10.00 $22,030.00 $10.00 $22,030.00 $10.00 $22,030.00 1,102 LF $25.00 $27,550.00 $25.00 $27,550.00 $25.00 $27,550.00 11. Trench Safety System 2,107 LF $0.54 $1,137.78 $0.05 $105.35 $0.25 $526.75 TOTAL WASTEWATER COLLECTION SYSTEM: $256,006.97 $282,614.35 $277,422.35 Page 3 of 8

HARRIS COUNTY UNIT BID TABULATION STORM WATER COLLECTION SYSTEM 1. 31 5/16-Inch x 57 1/8-Inch, C-506, Reinforced Concrete Arch Pipe Storm Sewer 2. 26 5/8-Inch x 43 3/4-Inch, C-506, Reinforced Concrete Arch Pipe Storm Sewer 3. 22 1/2-Inch x 36 1/4-Inch, C-506, Reinforced Concrete Arch Pipe Storm Sewer 903 LF $92.00 $83,076.00 $100.00 $90,300.00 $102.30 $92,376.90 1,169 LF $73.00 $85,337.00 $79.00 $92,351.00 $84.15 $98,371.35 596 LF $55.00 $32,780.00 $60.00 $35,760.00 $58.65 $34,955.40 4. 30-Inch CL III, R/G RCP Storm Sewer 371 LF $38.00 $14,098.00 $44.00 $16,324.00 $41.15 $15,266.65 5. 24-Inch CL III, R/G RCP Storm Sewer 125 LF $30.00 $3,750.00 $34.00 $4,250.00 $32.60 $4,075.00 6. 24-Inch CL III R/G RCP Storm Sewer Inlet Lead 340 LF $30.00 $10,200.00 $34.00 $11,560.00 $35.45 $12,053.00 7. Standard Type "C" Storm Sewer Manhole (24"-42") 3 EA $1,392.00 $4,176.00 $1,300.00 $3,900.00 $1,250.00 $3,750.00 8. Standard Type "C" Storm Sewer Manhole (48"-72") 8 EA $2,249.00 $17,992.00 $2,200.00 $17,600.00 $1,535.00 $12,280.00 9. Standard Type "C-1" Storm Sewer Inlet 6 EA $1,920.00 $11,520.00 $2,000.00 $12,000.00 $1,865.00 $11,190.00 10. Standard Type "C" Storm Sewer Inlet 1 EA $1,920.00 $1,920.00 $2,000.00 $2,000.00 $1,525.00 $1,525.00 11. Break Out and Connect Proposed 30-Inch CL III, R/G RCP Storm Sewer to Existing Type "C" Storm Sewer Manhole 12. 18-Inch Thick Buried Broken Concrete Rip Rap Including Woven Filter Fabric Surrounding 31 5/16 x 57 1/8 RCA Storm Sewer Outfall (80#-150#) 1 EA $750.00 $750.00 $420.00 $420.00 $525.00 $525.00 50 SY $74.00 $3,700.00 $36.00 $1,800.00 $36.25 $1,812.50 Page 4 of 8

UNIT BID TABULATION 13. 12-Foot Wide Crushed Stone All Weather Access Road on Compacted Subgrade; Including Geotextile Fabric (Contractor to strip all areas of all organics and deleterious materials to a minimum depth of 4-Inches below natural ground prior to the excavation, placement and grading of the crushed stone all weather access road at no additional expense to the Owner) HARRIS COUNTY 2,280 SY $8.00 $18,240.00 $13.00 $29,640.00 $10.35 $23,598.00 14. Re-Grade and Restore all Disturbed Areas in the Existing Portion of the Temporary Drainage Channel as a Result of 31 5/16 x 57 1/8 RCA Storm Sewer Outfall; Including but not Limited to, all Highbanks, Side Slopes, etc., to Original, or Better than Original, Condition; Including Turf Establishement as per the HCFCD Turf Establishment Specifications and Requirements; Inclusive of Watering, Fertilizing, Mowing and Maintenance Until a Stand of Bermuda Grass has been Established and all Governing Agencies have Inspected and Accepted the Subject Project Into the One Year Maintenance Period 1 LS $3,320.00 $3,320.00 $1,000.00 $1,000.00 $3,430.00 $3,430.00 15. Trench Safety 3,504 LF $0.54 $1,892.16 $0.05 $175.20 $0.10 $350.40 TOTAL STORM WATER COLLECTION SYSTEM: $292,751.16 $319,080.20 $315,559.20 STORM WATER COLLECTION SYSTEM (SECTION TWELVE) 1. 36-Inch x 58 1/2-Inch, C-506, Reinforced Concrete Arch Pipe Storm Sewer 2. 31 5/16-Inch x 57 1/8-Inch, C-506, Reinforced Concrete Arch Pipe Storm Sewer 174 LF $102.00 $17,748.00 $111.00 $19,314.00 $114.70 $19,957.80 171 LF $92.00 $15,732.00 $100.00 $17,100.00 $107.30 $18,348.30 3. 30-Inch CL III, R/G RCP Storm Sewer 308 LF $38.00 $11,704.00 $44.00 $13,552.00 $42.05 $12,951.40 4. 24-Inch CL III, R/G RCP Storm Sewer 120 LF $30.00 $3,600.00 $34.00 $4,080.00 $32.60 $3,912.00 Page 5 of 8

UNIT BID TABULATION HARRIS COUNTY 5. 24-Inch CL III R/G RCP Storm Sewer Inlet Lead 100 LF $30.00 $3,000.00 $34.00 $3,400.00 $35.45 $3,545.00 6. Standard Type "C" Storm Sewer Manhole (24"-42") 3 EA $1,474.00 $4,422.00 $1,400.00 $4,200.00 $1,250.00 $3,750.00 7. Standard Type "C" Storm Sewer Manhole (48"-72") 2 EA $2,286.00 $4,572.00 $2,200.00 $4,400.00 $1,610.00 $3,220.00 8. Standard Type "C-1" Storm Sewer Inlet 2 EA $1,920.00 $3,840.00 $2,000.00 $4,000.00 $1,865.00 $3,730.00 9. Remove, Dispose and Re-Construct Existing Standard Type "C" Storm Sewer Manhole (48"-72") and Connect Proposed 31 5/16-Inch x 57 1/8-Inch C-506, Reinforced Concrete Arch Pipe Storm Sewer and Existing 48-Inch RCP Storm Sewer to Re-Constructed Type "C" Storm Sewer Manhole 1 LS $6,377.00 $6,377.00 $5,300.00 $5,300.00 $1,665.00 $1,665.00 10. Trench Safety 873 LF $0.54 $471.42 $0.05 $43.65 $0.10 $87.30 TOTAL STORM WATER COLLECTION SYSTEM (SECTION TWELVE): $71,466.42 $75,389.65 $71,166.80 STORM WATER POLLUTION PREVENTION PLAN 1. Stage One Type "C" and Type "C-1"Storm Sewer Inlet Protection Barriers (oak timbers wrapped with filter fabric material on top of inlet and reinforced filter fabric fence barriers, RFFF as described above, surrounding the inlet, as indicated on the SWPPP details plan sheet) 9 EA $43.00 $387.00 $26.00 $234.00 $40.00 $360.00 Page 6 of 8

UNIT BID TABULATION 2. Enforcement of TPDES Requirements and General Source Controls; Including Filing NOI and NOT, Jobsite Postings, Regular Inspections, Filing Reports, etc. as Required for SWPPP Compliance for Duration of Underground Utility Construction Project; Contractor is to Practice Good Housekeeping Rules at All Times During Construction and is Responsible to Repair All Damage to the Control Measures as a Result of their own Construction Activities; Storm Water Solutions will be Responsible for Complete SWPPP Compliance for the Developer and for the Repair of Any and All Damage to the Control Measures Caused by Parties Other than the Contractor HARRIS COUNTY 1 LS $1,071.00 $1,071.00 $160.00 $160.00 $565.00 $565.00 TOTAL STORM WATER POLLUTION PREVENTION PLAN: $1,458.00 $394.00 $925.00 BID SUMMARY 1. Water Distribution System $136,631.18 $125,514.35 $139,302.50 2. Water Distribution System (Section Twelve) $139,289.84 $131,932.30 $137,522.10 3. Wastewater Collection System $256,006.97 $282,614.35 $277,422.35 4. Storm Water Collection System $292,751.16 $319,080.20 $315,559.20 5. Storm Water Collection System (Section Twelve) $71,466.42 $75,389.65 $71,166.80 6. Storm Water Pollution Prevention Plan $1,458.00 $394.00 $925.00 7. One-Time Only Construction Staking Service $16,750.00 $16,750.00 $17,000.00 (minimum bid $16,750.00) 8. Post Construction Topographic Verification of Underground Utilities and Record Drawing Preparation (minimum bid $7,250.00) $7,250.00 $7,250.00 $7,360.00 Page 7 of 8

UNIT BID TABULATION HARRIS COUNTY TOTAL AMOUNT BID: $921,603.57 $958,924.85 $966,257.95 CALENDAR DAYS 45 45 45 NOTE: EXPOSE AND BACKFILL UTILITIES UNDER FUTURE PAVEMENT WITH 1.1 SACK PER TON (MINIMUM) CEMENT STABILIZED SAND WITHIN ONE (1) FOOT OF THE PROPOSED PAVEMENT SUBGRADE. NOTE: DO NOT REMOVE AND/OR EXCAVATE DIAMOND "S" ACCESS DRIVE/HAUL ROUTE UNLESS AUTHORIZED, DIRECTED AND APPROVED BY THE ENGINEER TO DO SO. NOTE: BE MINDFUL OF ALL GAS PIPELINE EASEMENTS THAT TRAVERSE THROUGH AND ACROSS THIS PROPERTY. Page 8 of 8