ATD option. Auto Test & Self-diagnostic

Similar documents
OUTPUT CABLE CONNECTIONS:

User Manual for CH-PFC76810

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

T Sentry 4 Multi-Point Digital Alarm Instruction Manual

*.ppt 11/2/ :48 PM 1

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

INSTALLATION & SERVICE MANUAL. Display Panel

12 Volt 30 Amp Digital Solar Charge Controller

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

Solar Controller / Battery Charger User s Manual

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

The Black Box Push Button Control Box

TROUBLESHOOTING GUIDE

INSTALLATION GUIDE. FCC ID NOTICE

Mobile Data Power Model: MDP-25

Installation and Operation Guide for PD4000 Series Power Control Center

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

Back-UPS Pro 1300/1500 Installation and Operation

Fire Alarm Control Panel. Family. Operating Manual

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

POINTS POSITION INDICATOR PPI4

Conventional Fire Detection and Extinguishant Control System Specification

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Digital Keypad Use s Manual

GST301. (Single Protection Zone) Operation Manual

AUTODIALLER / QUICKDIALLER - SA132

Manual for Fire Suppression & Methane Detection System

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

HM-W536 Install Guide

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

Operational Overview and Controls Guide

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

WD-AMX Water Detection Controllers

9452/9453 Installation and User Guide

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Pro Logic Version Diagnostics Manual

APOLLO Gate Operators, Inc.

Installation and Operation Back-UPS 1250, 1300, 1500

210E - 210ECL ECL ECL RMS Signal Monitor. Operations Manual

DC LOAD TESTING Gian Trento June 18 th, 2004

FIREDEX Conventional Fire Panels

instabus KNX / EIB System System E F G H

BACK PRESSURE MONITOR Operator Display with Exhaust Temperature KIT

Field-Tested and Fixed in Five!

PUSH BUTTON START INSTALLATION MANUAL

Installation and Operation Guide for PD4100 Series Power Control Centers

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Servo Info and Centering

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Online UPS. PowerWalker VFI 1000R/1U

ABS Flash Code (Blink Code) Instructions

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

WIRING HARNESS FOR AS635P4. BLUE PLUG RED, BLUE, BLACK, WHITE - Plug in dual stage sensor harness

Using your LED Plus keypad

User s Information Guide R1A

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Installation and Operation Guide PD4600 Series Converter Replacement

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

PSC-A5 Solar Charge Controller Manual

Troubleshooting and Diagnostics

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

G-100/200 Operation & Installation

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

BLOCK OCCUPANCY DETECTOR WITH SEMAPHORE OPERATION BOD1/DAP4-BR

Telefon (+45) Telefax (+45) Installation and operating manual

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

Power Generation. Power Control PCL System Generator Set Control

OPERATING INSTRUCTIONS SECURITY SYSTEM KIT NO.: 08E51-EP American Honda Motor Co., Inc. - All Rights Reserved. 1

TREX OUTDOOR LIGHTING TROUBLESHOOTING GUIDE

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

Transmitter Interface Program

Home Solar Kit Owner s Manual. Model: HS

Schlage Wireless Locks User Guide

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Transcription:

DESCRIPTION The Aimlite Auto-Test and Self-Diagnostics option incorporates an advanced microprocessor based controller to accurately perform fully automated monitoring and testing. The system continously monitors normal unit status and automatically performs battery discharge tests at scheduled intervals. The testing improves unit reliability by exercising the batteries and insuring functional emergency operation. The self-diagnostic logic circuits monitor for battery and charger malfunctions, transfer circuit problems and emergency lamp circuit failure. Failure of these functions is signalled by a dedicated, tricolour LED indicator. The fault indication remains latched in the system until cleared by either correcting the problem or resetting the system. CIRCUITRY 120/347VAC 60Hz Input, field selectable 6VDC, 12VDC or 24VDC emergency power output versions (as specified) Fully automated, microprocessor based controller Momentary push button test switch Pilot LED for CHARGE Tri-colour, flashing and steady state indicator LED for system STATUS 10 minute time delay of transfer back to AC power once power is restored (allows for HID lighting to warm-up and restrike) High efficiency, rapid recovery, precision control charging system Fully automatic, current limited charger Line latched, low voltage protection Solid state design and construction Brownout and short circuit protection Temperature compensated Large magnum terminal screw type connectors for remote load connection Extremely sensitive to remote LED load VISUAL INDICATION The Aimlite Auto-Test and Self-Diagnostics option utilizes a tri-colour LED indicator to visually signal the operational condition of the unit. By combining this function into a single LED, Aimlite has greatly simplified the process of determining unit status. Additionally, the 3 colour system is highly intuitive and simple to understand: red for critical faults, yellow for functional faults and green for normal operation. Indication is further enhanced by appropriately flashing the indicated colour versus a steady state illumination. This RED-YELLOW-GREEN stoplight approach greatly simplifies trouble recognition by maintenance staff thereby speeding repairs and enhancing equipment reliability. NORMAL OPERATION Status indicator is Unit is functioning normally and successfully completed the most recent battery discharge test LAMP FAULT Status indicator is steady yellow. The lamp circuit has been disconnected or the lamps have burnt out BATTERY OR CHARGER FAULT Status indicator is either steady red or flashing red. The batteries are disconnected or the charger has failed (flashing) The unit failed the most recent battery discharge test (steady)

OPERATION Initialization 1) The Auto-Test can be reset or initialized by first disconnecting the batteries and then turning off the AC power supply. Reconnect the batteries and turn on AC power to complete the reset. 2) Upon power-up all automated timers are reset to zero and all status indicators will clear. 3) A unit operational status test will be initiated. The STATUS indicator may flash green during this test. 4) After successfully completing the test, the STATUS indicator will light 5) Any operational faults will result in the STATUS indicator lighting/flashing Automated Test 1) The internal timer will initiate the appropriate discharge test once every 30 days. 2) The test will be delayed by 24 hours if a manual test or power interruption had occurred in the previous 24 hours. 3) The CHARGE indicator will turn off and any connected load/lamps will illuminate for 5 or 30 minutes depending on the test scheduled. 4) After successfully completing the test, the STATUS indicator will light 5) Any operational faults will result in the STATUS indicator lighting/flashing Manual Test 1) To manually initiate an operational test, press and release the TEST pushbutton. 2) The CHARGE indicator will turn off and any connected load/lamps will illuminate. 3) The STATUS indicator may briefly flash then go illuminate a 4) The connected load will remain on for 10 mins. (automatic re-transfer delay) and then turn off. 5) The CHARGE LED will illuminate steady or flash depending on the required battery recharge. 6) After successfully completing the test, the STATUS indicator will light 7) Any operational faults will result in the STATUS indicator lighting/flashing DIAGNOSTICS Battery Condition Should the batteries become disconnected, the STATUS indicator will flash red. If the batteries fail to provide the required power during a discharge test, the STATUS indicator will light steady red. Battery Charger Charger output is continously monitored. Should output fail to meet the design parameters, the STATUS indicator will flash red. Battery Transfer Should the system fail to transfer to battery power during an AC power failure, the STATUS indicator will flash red. Lamps/Connected Load Should the lamp heads become disconnected or lamps burn out, the STATUS indicator will flash yellow. CODE COMPLIANCE The automated testing performed by the AimLite Auto-Test system has been designed to comply with all of the requirements of the National Fire Code. Every month a 5 minute discharge and diagnostic test checks the operational status of the unit. Every 6 months this test is extended to the full 30 minute, Code required duration. Additionally, following every other 6 month test (or once a year) the unit will repeat the same test 24 hours following the first test. This insures that the battery charger is recharging the battery in accordance with Code requirements as follows: National Fire Code of Canada - 2010 Section 6.7 Emergency Power Systems and Unit Equipment for Emergency Lighting 6.7.1.6. Inspection of Equipment...3) After completion of the test required in Clause (2)(b), the charging conditions for voltage and current and the recovery period shall be tested to ensure that the charging system is functioning in accordance with the manufacturer s specifications.

FOR RM SIGNS DESCRIPTION The Aimlite Auto-Test and Self-Diagnostics option incorporates an advanced microprocessor based controller to accurately perform fully automated monitoring and testing. The system continously monitors normal unit status and automatically performs battery discharge tests at scheduled intervals. The testing improves unit reliability by exercising the batteries and insuring functional emergency operation. The self-diagnostic logic circuits monitor for battery and charger malfunctions, transfer circuit problems and emergency lamp circuit failure. Failure of these functions is signalled by a dedicated, tricolour LED indicator. The fault indication remains latched in the system until cleared by either correcting the problem or resetting the system. CIRCUITRY 120/347VAC 60Hz Input, field selectable Fully automated, microprocessor based controller Momentary push button test switch Tri-colour, flashing and steady state indicator LED for system STATUS High efficiency, rapid recovery, precision control charging system Fully automatic, current limited charger Line latched, low voltage protection Solid state design and construction Brownout and short circuit protection Temperature compensated Extremely sensitive to remote LED load VISUAL INDICATION The Aimlite Auto-Test and Self-Diagnostics option utilizes a tri-colour LED indicator to visually signal the operational condition of the unit. By combining this function into a single LED, AimLite has greatly simplified the process of determining unit status. Additionally, the 3 colour system is highly intuitive and simple to understand. Indication is further enhanced by appropriately flashing the indicated colour versus a steady state illumination. This RED- ORANGE-GREEN stoplight approach greatly simplifies trouble recognition by maintenance staff thereby speeding repairs and enhancing equipment reliability. LED indicator Test switch RED Flashing RED Flashing ORANGE Flashing GREEN GREEN/RED AC ON AC problem LED board problem Battery or low voltage problem Self-testing mode

FOR RM SIGNS Operation Initialization 1) The Auto-Test can be reset or initialized by first disconnecting the batteries and then turning off the AC power supply. Reconnect the batteries and turn on AC power to complete the reset. 2) Upon power-up, all automated timers are reset to zero and all status indicators will clear. 3) A unit operational status test will be initiated. The LED indicator may flash green/red during this test. 5) Any operational faults will result in the LED indicator flashing. Automated Test 1) The internal timer will initiate the appropriate discharge test once every 30 days. 2) The test will be delayed by 24 hours if a manual test or power interruption had occurred in the previous 24 hours. 3) The CHARGE indicator will turn off and any connected load/lamps will illuminate for 5, 90 or 120 minutes depending on the test scheduled. 5) Any operational faults will result in the LED indicator flashing. Manual Test 1) To manually initiate an operational test, press and release the TEST pushbutton. 2) The indicator will turn off and any connected load/lamps will illuminate. 3) The indicator may briefly flash green/red. 5) Any operational faults will result in the LED indicator. Diagnostic Battery Condition Should the batteries become disconnected, the LED indicator will flash green. If the batteries fail to provide the required power during a discharge test, the LED indicator will light flash in green. Input Condition Should input fail to meet the design parameters, the LED indicator will flash green. LED Board Condition Should the LED become disconnected or burn out, the LED indicator will flash orange. Code compliance The automated testing performed by the Aimlite Auto-Test system has been designed to comply with all of the requirements of the National Fire Code. Every month, a 5 minute discharge and diagnostic test checks the operational status of the unit. Every 6 months, this test is extended to the full discharge, Code required duration. Additionally, following every other 6 month test (or once a year), the unit will repeat the same test 24 hours following the first test. This insures that the battery charger is recharging the battery in accordance with Code requirements as follows: National Fire Code of Canada - 2010 Section 6.7 Emergency Power Systems and Unit Equipment for Emergency Lighting 6.7.1.6. inspection of Equipment...3) After completion of the test required in Clause (2)(b), the charging conditions for voltage and current and the recovery period shall be tested to ensure that the charging system is functioning in accordance with the manufacturer s specifications.

Troubleshooting Guide Checklist 1. What is the model and serial number? 2. Ensure AC power is on 3. Ensure battery is connected 4. Has the unit in question been on charge for 24hrs? 5. What LEDs are ON? 6. What colours are the LEDs? 7. Are any of the LEDs flashing? Stop Light Analogy 1. If only one green solid LED is ON, this indicates AC is present and the battery is fully charged ready to use 2. If one green solid LED is ON and one yellow solid is ON this means a lamp is burnt out 3. If one LED is a solid or flashing red this means the battery is disconnected or the charger or battery failed the last test Start from the beginning 1. Turn Power OFF 2. Disconnect battery 3. Wait 5 minutes 4. Ensure load properly connected 5. Reconnect battery 6. Turn on AC 7. Wait 10-15 mins for AC power to be released to charger board 8. AC on will be indicated by led illuminating on charger board green along with red charger indicator at same time 9. Wait 24hrs for batteries to fully charge 10. Turn off breaker to units to ensure units meet 30 mins discharge 11. Turn AC breaker back ON after 30 mins 12. Units will remain ON for an additional 10-15 mins depending on how loaded units are 13. After a maximum of 15-20 mins the green and red LEDs will normally turn ON 14. If other colours or flashing are indicated refer to the catalogue page provided and call factory for assistance Built-In Time Delay ATD boards have a built-in digital counter which will not allow power to chip for 10 mins upon AC restoration. After 10 mins, the charge LED will be a steady green which will blink for no more than 24 hours. The status LED will be steady green indicating normal operation and AC input (on initial AC, the time delay is not triggered. This occurs when the AC line is cut). If after 10 min, the LED indicator does not illuminate, refer to the Re-setting the ATD board section. To Check Batteries 1. Disconnect positive and negative battery leads 2. Hook up remote load directly to batteries 3. Use a volt meter on DC to take reading. If below 10VDC (if the battery is 12V and the AT board is for 12V), the batteries are dead and need replacing 4. If the batteries hold voltage above 10VDC (if the battery is 12V and the AT board is for 12V) with load, leave disconnected and see below Re-setting the ATD Board 1. Remove battery leads from circuit board 2. Turn off AC power to unit 3. Wait 15 minutes until all power is drained from circuit board 4. Re-attach battery wires, observing polarity (red + black -) 5. Turn AC back on 6. When power is restored, there will be a green Status LED indicator 7. If batteries are drained, the Charge led indicator will be on (this is normal) 8. Wait 24 hours before testing