INSTRUCTION MANUAL APPA 99II

Similar documents
User's Guide. True RMS Industrial Multimeter

Manual Ranging MultiMeter

Model UT33A: OPERATING MANUAL Table of Contents (1)

AutoRanging Digital MultiMeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

UT202A Operating Manual. Contents

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

User Guide. Model Insulation Tester / Megohmmeter

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

Intelligent Digital Multimeters

10 Multimeter. Users Manual

Model UT58A/B/C: OPERATING MANUAL

Model UT60A: OPERATING MANUAL. Table of Contents. Page

Table of Contents. Page

Model UT201/202: OPERATING MANUAL. Table of Contents

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

How To Use A Cdm250 Digital Multimeter

User Guide. 4 wire Earth Resistance Tester Model GRT300

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Model UT71A/B OPERATING MANUAL

Ground Resistance Clamp On Tester

1. SAFETY INFORMATION

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Dual Display Digital Multimeter

7 FUNCTION DIGITAL MULTIMETER

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

i410/i1010 AC/DC Current Clamp

115C and 117C. True-rms Multimeters. Users Manual

Integrating Sound Level Meter and Datalogger

Model 77 Series IV Digital Multimeter

Ground Resistance Clamp-On Tester

User's Guide Integrating Sound Level Datalogger Model

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

RS DIGITAL THERMOMETER

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE

Fluke 3000 FC Series Test Tools Technical Data

SOUND LEVEL METER 94405

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Owner s Manual & Safety Instructions

HVAC Clamp Meter. Users Manual

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

User's Guide. Digital Sound Level Meter. Model

Model UT713 OPERATING MANUAL

Microwave Meter. Instruction Manual

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Seven function digital multimeter

Essential Electrical Concepts

323/324/325. Calibration Manual. Clamp Meter

Users Manual. ProcessMeter

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Thermistor Thermometer MODEL NO

INTRODUCTION SAFETY PRECAUTIONS/

TMS TANK MANAGEMENT SYSTEM

User Manual for CH-PFC76810

DC POWER SUPPLY ALIMENTATION C.C.

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

The Basics of Digital Multimeters

Panel Meters and Controllers Modular Panel Meter Type EDM 35

1587/1577. Insulation Multimeters. Users Manual

Temperature Humidity Meter

What is a multimeter?


162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Drayton Digistat +2RF/+3RF

Multimeter with Temperature

12-Volt 10-Amp Regulated Power Supply

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

No.1. Digital Multimeter RIGOL TECHNOLOGIES, INC.

Instructions A Amp AC/DC Current Probe

Instruction Manual Temp 4/5/6 Temperature Meter Series

User s Manual Before using the inverter, you need to read and save the safety instructions.

DSM155 Digital LED Light Meter User s Manual DSM155

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Light Meter (Foot Candles)

Energy Management Energy Meter Type EM23 DIN

Series AMLDL-Z Up to 1000mA LED Driver

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Digital Clamp-on DMMs with uncompromising performance

ABCs of DMMs Multimeter features and functions explained Application Note

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

Pocket Tach 99 (PT99) Non-Contact Tachometer

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Hygro-Thermometer + InfraRed Thermometer Model RH101

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

2000 6½-Digit Multimeter

12 Volt 30 Amp Digital Solar Charge Controller

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

4-Channel Thermometer / Datalogger

Thermocouple Thermometer Models

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Table of Contents. Page No.

Fluke 3000 FC Series Test Tools Technical Data

Transcription:

DIGITAL MULTIMETER 6 INSTRUCTION MANUAL APPA 99II 34

# WARNING THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK, DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO. 1

INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Multimeter from its packing, you should have the following items: 1. Digital Multimeter. 2. Test lead set (one black, one red). 3. Instruction manual. 4. Protective holster. 5. K Type Temperature Sensor. 6. Sensor Adaptor. 2

1-2 Meter Safety Terms as Marked on Equipment. # ATTENTION Refer to manual. 1 DOUBLE INSULATION Protection Class. " DANGER Risk of electric shock. Symbols in this Manual. # This symbol indicates where cautionary or other information is found in the manual. FUSE Battery 3

1-3 Front Panel Refer to Figure 1 and to the following numbered steps to familiarize yourself with the meter s front panel controls And connectors. 1. Digital Display The digital display has 4000 counts LCD readout with 82 segments analog bar graph, auto polarity, decimal point, AC, DC RANGE, APO REL MAX, MIN, PMAX, PMIN and unit annunciators. 2. Rotary Switch Select the Function and Range desired. 3. COM Input Terminal Ground input connector. 4. ºC V Hz Input Terminal Positive input connector for Volts, Ohms Capacitance and Temperature Frequency. 5. ma Input Terminal Positive input connector for Amp measurements (up to 400mA). 6. A Input Terminal Positive input connector for Amp measurements (up to 10A). 7. Range Switch, (Manual Range) Press the Range switch to select manual ranging. The RANGE annunciator will be displayed. Pressing the Range switch permits selection of the appropriate measuring range. To return to Autoranging press and hold the Range switch for 2 seconds. 4

8. REL / (PMIN/MAX) switch A. In voltage and current modes, pressing REL performs maximum and minimum PEAK hold function. Pressing REL toggles between PMIN and PMAX measured values and the PMIN or PMAX annunciators are displayed. To calibrate this function press and hold REL until the CAL annunciator is displayed, then short the test leads until the display reads zero. Press and hold the REL switch to exit this function. B. In all other modes pressing the REL switch precuts comparison between two measured values. When taking the first measurement press the REL switch to store the reading, the REL annunciator will be displayed and the reading is zeroed. When taking the second measurement the display will show the difference between measurement 2 and measurement 1 (will be negative if measurement 1 is large than measurement 2 ). Pressing the REL switch again causes the display to show measurement 2, and the REL annunciator will flash. To exit this mode press and hold the REL switch for 2 seconds. 9. MIN/MAX switch This switch is used to display MAX and MIN values of measurement, press 2 seconds to quit. In this mode, when MAXMIN is blinking the reading is of measuring signal. 5

10. Hold Switch This switch is used to hold measured value for all functions, the RANGE annunciator are displayed. Conversions are made but the numeric display is not updated. This switch can be invoked to MIN/MAX mode or PMIN/PMAX mode. 11. Light switch Press this switch to turn on or turn off the back-light. 12. Blue Switch Press the switch to measure AC Voltage / Current or DC Voltage / Current in the voltage / Current mode or to measure Resistance or continuity or diode in / /: mode or to measure Frequency or RPM in Hz/RPM mode. 6

Figure 1 7

SPECIFICATIONS 2-1 General Specifications Display : The Liquid Crystal Display (LCD) with a maximum reading of 4000 and 82 segments bar graph. Polarity Indication : Automatic, positive implied, negative indicated. Overrange Indication : OL or -OL. Low Battery Indication : is displayed when the battery voltage drops below operating voltage. Sampling : 2 times/sec for digit. 12 times/sec for analog bargraph. Auto Power Off : Approx 30 minutes. Operating Ambient : 0ºC ~ 30ºC ( 80%R.H), 30ºC ~ 40ºC ( 75%R.H), 40ºC ~ 50ºC ( 45%R.H). Storage Temperature : -20ºC to 60ºC, 0 to 80% R.H. when battery removed from meter. Temperature Coefficient : 0.15 x (specified accuracy) / ºC, <18ºC or > 28ºC. Power Requirements : Standard 9V battery NEDA 1604, IEC6F22, JIS006P. Battery Life : Alkaline 300 hours. 8

Dimensions (W x H x D) : 88mm x 180mm x 33.5mm, without holster. 94mm x 188mm x 40mm, with holster. Accessories : Protective Holster, battery (installed), instruction manual, test lead, K-type Temperature Sensor and Sensor Adaptor. 2-2 Environmental Conditions Indoor use. Maximum Altitude : 2000 Meter. Installation Category : IEC 1010, 1000V Cat., 600V Cat.. Pollution Degree : 2 9

2-3 Electrical Specifications Accuracy is (% reading + number of digits) at 23ºC 5ºC, less than 80% R.H. (1) DC Volts Range Resolution Accuracy 400mV 100µV (0.25% reading + 5 digits) Over voltage protection 4V 1mV (0.4% reading + 1digit) 40V 10mV DC 1000V 400V 1000V 100mV 1V (0.25% reading + 1digit) Input Impedance : 10M. (over 1000M in 400mV range). 10

(2) AC Volts Range Resolution Accuracy Over voltage protection 400mV 0.1mV (2.0% reading + 8 digits) 3 4V 1mV (1.3% reading + 5 digits) 1 2 40V 400V 750V 10mV 100mV 1V (1.3% reading + 5 digits) 1 40Hz to 1KHz 750V rms Input Impedance : 10M // less than 100pF. 1. (1.5% reading + 5 digits) for (50% ~ full scale) of range. 2. Frequency Response : 40Hz ~ 1KHz ; (1.5% + 5 digits) for 500Hz ~ 1KHz. 3. Frequency Response : 50Hz ~ 60Hz. AC Conversion Type : AC conversions are ac-coupled, true rms responding, calibrated to the rms value sine wave input. 11

Crest Factor : +1.5% addition error for C.F. from 1.4 to 3 where C.F. = Peak +3.0% addition error for C.F. from 3 to 4 RMS (3) DC Current Range Resolution Accuracy Voltage Burden 40mA 10µA (0.6% reading + 2 digits) 200mV max 400mA 10A 0.1mA 10mA (0.7% reading+ 2 digits) 2V max (1.0% reading + 3digits) 2V max Overload Protection : 1A (500V) fast blow fuse for ma input. 10A (500V) fast blow fuse for A input. Both 10KA breaking capacity @ 440 Vac, size 32 x 6.3mm. 12

(4) AC Current Range Resolution Accuracy Voltage Burden 40mA 10µA 400mA 0.1mA (2.0% reading + 5 digits) 200mV max 2V max 10A 10mA (2.5% reading + 5 digits) 2V max Frequency Response : 40Hz ~ 1KHz. Overload Protection : 1A (500V) fast blow fuse for ma input. 10A (500V) fast blow fuse for A input. Both 10KA breaking capacity @ 440 Vac, size 32 x 6.3mm. AC Conversion Type : AC conversions are ac-coupled true rms responding, calibrated to the rms value sine wave input. Crest Factor : +1.5% addition error for C.F. from 1.4 to 3 where C.F. = Peak +3.0% addition error for C.F. from 3 to 4 RMS 13

(5) Resistance Range Resolution Accuracy 400 0.1 (0.7% reading + 3 digits) Overload Protection 4K 1 40K 10 400K 100 4M 1K (0.4% reading +3 digits) (0.6% reading + 3 digits) 600V rms 40M 10K (1.5% reading + 5 digits) Open circuit Voltage : -1.3V approx. 14

(6) Diode Check and Continuity Range Resolution Accuracy Max. Test Current Max. Open Circuit Voltage 1mV (1.5% reading + 5 digits)* 1.5mA 3V * For 0.4V ~ 0.8V. Overload Protection : 600V rms max. Continuity : Internal sounder will activate when resistance is less than 30 approximately. 15

(7) Frequency / RPM Range Resolution Sensitivity Accuracy Overload Protection 4.0KHz/40KRPM 40KHz/400KRPM 1Hz/30RPM 10Hz/300RPM 100mV rms Frequency : 0.01% 1 digit 400KHz/4MRPM 100Hz/3KRPM 600V rms 4MHz/40MRPM 1KHz/30KRPM 250mV rms 40MHz/400MRPM 10KHz/300KRPM 1V rms RPM : 0.01% 10 digits 16

(8) Capacitance Range Resolution Accuracy Overload Protection 4nF 1pF 40nF 10pF 400nF 100pF 4µF 1nF 40µF 10nF 400µF 100nF * 4mF 1µF * 40mF 10µF (3%reading + 10digits) * (2%reading + 8digits) ** (5%reading + 20digits) 600V rms * 4mF and 40mF ranges may have rolling within accuracy. ** specify reading < half full scale of range. 17

(9) Temperature (ºC) Temperature Accuracy Overload Protection -20ºC ~ 0ºC (2% reading + 4ºC) 1ºC ~ 100ºC (1% reading + 3ºC) 101ºC ~ 500ºC (2% reading + 3ºC) 600V rms 501ºC ~ 800ºC (3% reading + 2ºC) 18

(10) Temperature ( ) Temperature Accuracy Overload Protection -4 ~ 32 33 ~ 212 213 ~ 932 933 ~ 1472 (2% reading + 8 ) (1% reading + 6 ) (2% reading + 6 ) (3% reading + 4 ) 600V rms 19

(11) PEAK HOLD Function Range Accuracy Function Range Accuracy DCV ACV 400mV 4V 40V 400V 1000V 400mV 4V 40V 400V 750V Unspecified 40mA (1.5% reading + 300 digits) 2* 400mA (3% reading +60 digits) DCI (1.5% reading + 60 digits) 10A (1.5% reading + 60 digits) Unspecified ACI 40mA (1.5% reading + 300 digits) 2* 400mA (1.5% reading +60 digits) 10A (3% reading +60 digits) (1.5% reading + 60 digits) 20

Note : 1. With zero calibrated before measurement. 2* 4V range specifies readings above 10% of full scale of range. 3. Amp ranges specify reading <90% of full scale of range. 4. In the noise generating field, may affect intervals. (12) Auto Power Off (APO) The APO annunciator on the LCD panel indicates that the meter is working in the Auto Power Off mode. If the meter idles for more than 30 minutes, the meter automatically turns the power off. When this happens, the state (non-logic measurement) of the meter is stored. The meter can be turned back on by pushing any switch except back light switch or changing the rotary switch. If the meter is Re-Powered by pushing any switch, the LCD displays the stored value. Pressing the Hold switch disables the hold state. The meter will produce a periodic alarm 15 seconds before automatically turning power off, any key press or rotary change will reset the Auto-Power-Off delay of 30 minutes. (13) Disable Auto Power Off In order to disable Auto Power Off function, power up the meter whilst pressing any of the function switches other than the Hold or BLUE switches. 21

OPERATION This instrument has been designed and tested in accordance with IEC Publication 1010, Safety Requirements for Electronic Measuring Apparatus and has been supplied in a safe condition. This instruction manual contains some Information and warnings which have to be followed by the user to ensure safe operation and to retain the instrument in safe condition. 3-1 Preparation and Caution before Measurement 1. Before measurement, switch the meter on and allow it to warm up for at least 60 seconds. 2. When the rotary function selector is changed during measurement, be sure do so only after removing the test leads from the equipment. 3. If the equipment is used near noise generating equipment, be aware that may become unstable or indicate large errors. 4. # Maximum rated voltage to earth for voltage and current measurements terminals is 1000V CAT., 600V CAT.. 22

3-2 Voltage Measurements 1. Connect the red test lead to the ºC V Hz input terminal and the other (black) test lead to the COM terminal. 2. Set the rotary function to the V position. 3. Measurement of AC voltage can be performed by pushing the BLUE key switch. 4. Connect the test leads to the circuit to be measured. # WARNING TO AVOID ELECTRICAL SHOCK, HAZARD OR DAMAGE TO METER, DO NOT A ATTEMPT TO MEASURE VOLTAGE THAT MIGHT EXCEED 1000V ms. DO NOT APPLY MORE THAN 1000V rms BETWEEN THE COMMON INPUT TERMINAL AND EARTH GROUND. NOTICE UNSTABLE DISPLAY MAY OCCUR ESPECIALLY AT 400mV RANGE, EVEN THOUGH YOU DON T PUT TESTED LEADS INTO INPUT TERMINALS. IN THIS CASE, IF AN ERRONEOUS READING IS SUSPECTED, SHORT THE V Hz TERMINAL AND THE COM TERMINAL, AND MAKE SURE THE DISPLAY READS ZERO. 23

3-3 Current Measurement 1. Connect the red test lead to ma terminal and the other (black) test lead to COM terminal, or use the A and COM terminal in the 10A range. 2. Set function selector rotary switch to ma or A. 3. Measurement of AC current can be performed by pushing the BLUE switch. 4. Connect the test leads to the circuit to be measured. 3-4 Resistance Measurement 1. Connect the red test lead to the ºC V Hz terminal and the other (black) test lead to the COM terminal. 2. Set the rotary function selector to : position to measure the resistance. 3. For correct reading, ensure that the device being tested contains no voltage. 4. Connect the test leads across the circuit to be measured. In order to ensure the bes t accuracy in measurement of low resistance, to except the resistance of test leads by REL function, short the test leads and stored it by pressing REL key. 24

3-5 Continuity Check by Internal Sounder 1. Connect the red test lead to the ºC V Hz terminal and the other (black) test lead to the COM terminal. 2. Set the rotary function selector to : position. 3. Connect the test leads to the circuit to be measured. The internal sounder will operate if the resistance of the circuit measured is lower than 30 approximately. 3-6 Diode Check 1. Set the rotary switch at : position. 2. Connect black test lead to COM terminal and red lead to ºC V Hz input terminal. 3. Connect test leads to the diode normally the forward voltage drop of good silicon diode is shown between 0. 400V and 0.900V. If the diode under test is defective. 0.000 (short circuit) or OL (non-conductance) is displayed. During check, the diode under test is defective, if 0.000 or other values are displayed. 25

3-7 Hz / RPM Measurement 1. Connect the red test lead to the ºC V Hz terminal and the other (black) test lead to the COM terminal. 2. Set the rotary function selector to Hz RPM position to measure the frequency or RPM. 3. Connect the test leads to the circuit to be measured. 3-8 Capacitance Measurement 1. Connect the red test lead to the ºC V Hz terminal and the other (black) test lead to the COM terminal. 2. Set the rotary function selector to position to measure capacitance. 3. Connect the test leads to the circuit to be measured. 4. In order to ensure the best accuracy in measurement of low capacitance, to except the stray capacitance of test leads by test leads open with pressing REL key to store. 3-9 Temperature 1. Connect the of ADAPTOR to the ºC V Hz terminal and to the COM terminal. 2. Combine the sensor with the adaptor. 3. Set the rotary function selector to ºC or position to measure temperature value. 26

MAINTENANCE # WARNING : TO AVOID ELECTRICAL SHOCK REMOVE TEST LEAD BEFORE OPENING THE COVER. 4-1 General Maintenance 1. Repairs or servicing not covered in this manual should only be performed by qualified personal. 2. Periodically wipe the case with a dry cloth and detergent do not use abrasives or solvents. 4-2 Battery Installation or Replacement The meter is powered by 9V battery. Refer to Figure 2 and use the following procedure to replace the battery: 1. Disconnect the test leads and turn the meter off. Remove the test leads from the front terminals. 2. Position the meter face down. Remove the screw from the battery cover. 3. Lift the end of the battery cover until it gently unsnaps from the case bottom. 4. Lift the battery from the battery compartment and carefully disconnect the battery connector leads. 5. Snap the battery connector leads to the terminals of a new battery and reinsert the battery into the battery compartment. 6. Replace the battery cover. Make sure that the battery leads do not become pinched between the case bottom and case top. 27

Screw (i) Battery Cover (ii) 9V Battery Figure 2 28

4-3 Fuse Replacement Refer to Figure 3 and the following procedure to examine or replace the meter s fuse: 1. Perform steps 1 though 3 of the battery replacement procedure. 2. Remove the two screws from the case bottom and lift the case bottom until it gently unsnaps from the case top. 3. Remove the defective fuse by gently prying one end of the fuse loose and sliding the fuse out of the fuse holder. 4. Install a new fuse of same size and rating. Make sure the new fuse is centered in the fuse holder. 5. Replace the case top and case bottom and battery cover bottom. Make sure that the battery leads do not be come pinched between the case halves. Reinstall the three screws. 29

Bottom Case Top Case Figure 3 Radid Rapid Fuse 1A (500V), 10KA capacity @ 440 Vac 30 10KA Radid Rapid Fuse capacity Fuse 10A 16A (500V), 10KA capacity @ (500V), 440 440 Vac Vac Fuse size is is 32mm x x 6.3mm

31

HOW TO USE THE TILT STAND AND HOLSTER Swing the stand out for easier meter reading. 32 Swing the upper holder out and hook it over a door.

HOW TO USE THE TILT STAND AND HOLSTER Meter in holster face down. 33 Hang on nail at workbench.

APPA TECHNOLOGY CORP. 9F.119-1 Pao-Zong Rd., Shin-Tien, Taipai, 23115, Taiwan, R.O.C. P.O.Box. 12-24 Shin-Tien, Taiwan. Tel : 886-2-9178820 Fax : 886-2-9170848 e-mail:info @appatech.com http://www.appatech.com Copright 3 2003, APPA Tech., Corp. All rights reserved. Printed In Taiwan