95000 series, 2/2 Direct solenoid actuated poppet valve

Similar documents
97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

2/2 & 3/2 Solenoid operated valves

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Compact pressure switch Flameproof enclosure Ex d Model PCA

Assisted lift operated 2/2-way solenoid valves Type EV250B

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-way Solenoid Valve, direct-acting, NC or NO

4/2-Way Pneumatic Solenoid Valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Solenoid valves 2/2-way direct-operated Type EV210A

2.12. page Products for Explosion hazardous Environment

4 Posiflow Proportional Solenoid Valves

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Series 8146/5-V37 and Series 8150/5-V37

type V46, solenoid or pneumatic operated

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

3/2-way pneumatic cartridge solenoid valve

Control- and feedback head for integrated mounting on Robolux valves Type 2036

RM/55401/M, Roundline cylinder Magnetic piston, double acting

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

KA/8000/M, KA/8000, ISO cylinder (Stainless steel) Magnetic & Non-magnetic piston, double acting

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

System 8. ü ( System 8

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

SOLENOID VALVES AND PNEUMATIC VALVES

3/2-way Mini Solenoid Valve

Terminal Boxes Series 8146

Plug and Socket Devices CES 63 A Series 8579

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Solenoid Valve Island Type 3965

3/2- and 2/2-way cartridge valve type BVE

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Single sub-base valve

SITRANS F flowmeters SITRANS F M

How To Use A Flowmeter

Electro-pneumatic control valves

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Plastic tube flowmeters Series PT/PS

Plug and Socket Devices SolConeX 16 A Series 8570

Operating Instructions

Inductive sensor NI10-M18-Y1X-H1141

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Solenoid valves Type EVU

3/2 Solenoid Cartridge Valve, Size 6

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

STC 3S A Series Solenoid Valves

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Control and Distribution Boxes made of Stainless Steel Series 8150

Directional seated valves type VP 1

Operating Instructions

Scraper Passage Indicator. Electrical Indicator. Features

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Technical Data. Dimensions

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Explosion proof enclosures

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Type 3353 Angle Seat Valve

Operating Instructions

A good connection. International approvals.

Flow switches Series AD/VH

2/2 and 3/2 Way Size 6 Seat Valves

Cable Plug acc. to DIN EN , Form A

Technical data sheet TDS0070

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

Technical Information RIA14

Floodlight Range Installation Guide

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Proportional pressure regulators VPPE

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Technical Data. Dimensions

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Software and Display instruments

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Electronic, Digital and Mechanical Vibration Switches

Digital inductive conductivity transmitter

3 Port Solenoid Valve

RM4TG20 three-phase network control relay RM4-T - range V

G1/4 Q8. Standard with biased position

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

servo-controlled 3-WaY vacuum solenoid valves WiTH

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Electric Rotary Actuator - On/Off or programmable control actuator

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

Operating Instructions for Plastic Flow Meter. Model: KSK

Relative and absolute pressure switch type 529

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Thermostatic valve Type AVTA

Transcription:

> > Port size: /4 (ISO G or NPT), G/ > > Working from 0 bar up > > Short switching times > > Suited for fine vacuum down to,33 x 0 - mbar > > For a.c. solenoid systems with integrated rectifier (40... 60 Hz) > > Variable valve solenoid combination Technical features Medium: For neutral gaseous and liquid fluids (with contaminated fluids, upstream installation of a dirt trap is recommended) Operation: Direct solenoid operated poppet valve Operating pressure: 0... 40 bar (0... 580 psi) Orifice:,5... mm Port size: G/4, /4 NPT, G/ Flow direction: Fixed Mounting position: Optional, preferably with solenoid on top Ambient/Media temperature: NBR: -5... +80 C (-3... +76 F) FPM: -0...+0 C (+4... +48 F) Water +95 C (+03 F) EDPM: -40... +40 C (-40... +84 F) FFPM: -0...+40 C (+4... +84 F) PTFE: -50...+0 C (-58... +356 F) Depending on solenoid system and seal materials. Air supply must be dry enough to avoid ice formation at temperatures below + C (+35 F). Material: Housing: brass.040 (Ms 58) Seals: NBR other see option selector Inner parts: stainless steel.404 (0 F), brass.040 (Ms 58) Further versions Operating pressure to 50 bar; Seat seals FPM, EPDM, FFPM, PTFE, Rubin; Assembled oil and grease-free Flow conversion: Cv US Gallon/min (water) = l/min (air) x 0,00 Kv m³/h (water) = l/min (air) x 0,000906 Technical data Housing: Brass, Seals: NBR -5... +80 C (-3... +76 F) Symbol Port size Orifice Flow Operating pressure Weight Dimension Solenoid Model (mm) (l/min) (bar) (psi) (kg) (lbs) No. group *) G/4,5 70 0... 40 0... 580 0, 0.46 3B 950000 G/4 0 0... 35 0... 507 0, 0.46 3B 950000 /4 NPT 0 0... 35 0... 507 0, 0.46 3B 950300 G/4 3 00 0... 0 0... 45 0, 0.46 3C 9500300 0 /4 NPT 3 00 0... 0 0... 45 0, 0.46 3C 9503300 G/4 4 350 0... 0... 74 0, 0.46 3D 9500400 /4 NPT 4 350 0... 0... 74 0, 0.46 3D 9503400 G/4 6 550 0... 5 0... 7 0,5 0.55 6D 950600 /4 NPT 6 550 0... 5 0... 7 0,5 0.55 6D 9504600 G/ 700 0... 0... 4 0,8.76 4 6D 950700 0 G/4 00 0... 0 0... 90 0, 0.46 3 3B 9500 G/4 3 60 0... 0 0... 45 0, 0.46 3 3B 95030 *) When ordering please indicate solenoid, voltage and current type (frequency). without notice, the specifications given in this document. (006-50e) 05 Norgren GmbH en 5.4.304.0

Option selector 950X X Orifice (mm) Substitute,5 3 3 4 4 6 6 7 Material seat seal Substitute NBR 0 EDPM FPM PTFE only orifice,5... 4 NC 3 FFPM 4 Rubin only orifice... 3 NC 5 Voltage Substitute 4 V d.c. 0400 30 V a.c. 3050 Solenoid Substitute See solenoid table en 5.4.304.0 without notice, the specifications given in this document. (006-50e) 05 Norgren GmbH

Solenoids group 3B, standard voltages Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (m A) (m A) Protection class IP/NEMA 8,0 33 IP65 (with 9, 40 IP65 (with 8,0 33 IP65 (with - 9, - 40 IP65 (with Ex-Protection (ATEX-Category) Temperature Ambient/ Media ( C) II 3 D Ex td A T 0 C II 3 D Ex td A T 0 C 6,9-89 - IP66 II G Ex mb IIC T4 Gb II D Ex mb IIIC T0 C Db - 8,7-34 IP66 II G Ex mb IIC T4 Gb II D Ex mb IIIC T0 C Db 3,9-6 - IP66 (with - 5,3-3 IP66 (with 3,9-6 - IP66 (with - 5,3-3 IP66 (with 3,9-6 - IP66 (with 5,3 3 IP66 (with 5,5 8 NEMA 4, 4X, 5,9 6 NEMA 4, 4X, IP66 IP66 Electrical connection -0... +60 Special included -0... +60 Special included -0... +60 Cable length 3 m -0... +60 Cable length 3 m T4: T4: T4: T4: T4: T4: Weight Drawing Circuit diagram Model (kg) No. No. 0,5 046 0,6 7 306 0,6 36 0,6 6 3 0,4 5 4 09 0,4 5 7 093 M0 x,5 *) 0,5 6 4 40 M0 x,5 *) 0,5 6 7 4 / NPT *) 0,8 7 0 460 / NPT *) 0,8 7 46 M0 x,5 *) 0,8 7 0 46 M0 x,5 *) 0,8 7 463 0,5 8 37 0,5 8 5 373 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) /cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Approvals ATEX IECEx FM 09x KEMA 0 ATEX 347 X IECEx DEK 3.004X N/en 7..505 3x, 38x EC-Declaration of Conformity N/en 7..570 37x, 38x CSA-LR 576-6 N/en 7..575 ATEX IECEx 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X N/en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X N/en 7..585 without notice, the specifications given in this document. (006-50e) 05 Norgren GmbH en 5.4.304.03

Solenoids group 3C, standard voltages Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (m A) (m A) Protection class IP/NEMA, 504 IP65 (with,3 49 IP65 (with, 504 IP65 (with,3 49 IP65 (with Ex-Protection (ATEX-Category) Temperature Ambient/ Media ( C) II 3 D Ex td A T 30 C II 3 D Ex td A T 0 C 0,7 446 IP66 II G Ex mb IIC T4 Gb II D Ex mb IIIC T0 C Db,4 54 IP66 II G Ex mb IIC T4 Gb II D Ex mb IIIC T0 C Db 8,9 369 IP66 (with 0,0 IP66 (with 8,9 369 IP66 (with 0,0 IP66 (with 8,9 369 IP66 (with 0,0 IP66 (with 8,9 369 NEMA 4, 4X, 9,5 4 NEMA 4, 4X, IP66 IP66 Electrical connection -0... +60 Special included -0... +50 Special included -0... +40 Cable length 3 m -0... +40 Cable length 3 m T4: -40... +65 T5: -40... +55-40... +65 T4: -40... +65 T5: -40... +55-40... +65 T4: -40... +70 T6: -40... +40-40... +70 T4: -40... +70 T6: -40... +40-40... +70 T4: -40... +70 T6: -40... +40-40... +70 T4: -40... +70 T6: -40... +40-40... +70 Weight Drawing Circuit diagram Model (kg) No. No. 0,7 000 0,60 6 304 0,7 37 0,7 6 39 0,4 5 4 090 0,4 5 7 09 M0 x,5 *) 0,5 6 4 40 M0 x,5 *) 0,5 6 7 4 / NPT *) 0,8 7 0 460 / NPT *) 0,8 7 46 M0 x,5 *) 0,8 7 0 46 M0 x,5 *) 0,8 7 463 0,5 8 374 0,5 8 5 375 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) /cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Approvals ATEX IECEx FM 09x KEMA 0 ATEX 347 X IECEx DEK 3.004X N/en 7..505 3x, 38x EC-Declaration of Conformity N/en 7..570 37x, 38x CSA-LR 576-6 N/en 7..575 ATEX IECEx 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X N/en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X N/en 7..585 en 5.4.304.04 without notice, the specifications given in this document. (006-50e) 05 Norgren GmbH

Solenoids group 3D, standard voltages Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (m A) (m A) Protection class IP/NEMA 6,9 703 IP65 (with 9,5 75 IP65 (with,4 475 IP66 (with 5, 66 IP66 (with,4 475 IP66 (with 5, 66 IP66 (with,4 475 IP66 (with 5, 66 IP66 (with 3,6 567 NEMA 4, 4X, 5,7 68 NEMA 4, 4X, Ex-Protection (ATEX-Category) Temperature Ambient/ Media ( C) IP66 IP66 T4: T4: T4: T4: T4: T4: Electrical connection Weight Drawing Circuit diagram Model (kg) No. No. 0,7 3 0700 0,3 4 6 3703 M0 x,5 *) 0,5 6 4 0 M0 x,5 *) 0,5 6 7 / NPT *) 0,8 7 0 4630 / NPT *) 0,8 7 463 M0 x,5 *) 0,8 7 0 463 M0 x,5 *) 0,8 7 4633 0,5 8 376 0,5 8 5 377 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) /cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Approvals ATEX IECEx FM 3x, 38x EC-Declaration of Conformity N/en 7..570 37x, 38x CSA-LR 576-6 N/en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X N/en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X N/en 7..585 without notice, the specifications given in this document. (006-50e) 05 Norgren GmbH en 5.4.304.05

Solenoids group 6D, standard voltages Power consumption 4 V d.c. 30 V a.c. (W) (VA) Rated current 4 V d.c. 30 V a.c. (m A) (m A) Protection class IP/NEMA 6,9 703 IP65 (with 7,3 75 IP65 (with 6,9 703 IP65 (with 7,3 75 IP65 (with,4 475 IP66 (with 5, 66 IP66 (with,4 475 IP66 (with 5, 66 IP66 (with,4 475 IP66 (with - 5, 66 IP66 (with 3,6 567 NEMA 4, 4X, 5,7 68 NEMA 4, 4X, Ex-Protection (ATEX-Category) Temperature Ambient/ Media ( C) II 3 D Ex tda IP65 T30 C II 3 D Ex tda IP65 T0 C IP66 IP66 Electrical connection Weight Drawing Circuit diagram Model (kg) No. No. 0,6 3 0800 0,35 4 6 3803-0... +60 Special included 0,7 3 387-0... +50 Special 0,36 4 6 389 included T4: M0 x,5 *) 0,5 6 4 480 T4: T4: T4: T4: T4: M0 x,5 *) 0,5 6 7 48 / NPT *) 0,8 7 0 4680 / NPT *) 0,8 7 468 M0 x,5 *) 0,8 7 0 468 M0 x,5 *) 0,8 7 4683 0,5 8 386 0,5 8 5 387 Standard voltages (±0%) 4 V d.c., 30 V a.c., other voltages on request. Design according to VDE 0580, EN 5004/5008. 00% duty cycle. *) /cable gland is not scope of delivery, see table»accessories«attention: The protection class for coil series 46xx and 48xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Approvals ATEX IECEx FM 37x, 38x CSA-LR 576-6 N/en 7..575 4xx KEMA 98 ATEX 445 X IECEx KEM 09.0068X N/en 7..580 46xx PTB 0 ATEX 085 X IECEx PTB.0094X N/en 7..585 en 5.4.304.06 without notice, the specifications given in this document. (006-50e) 05 Norgren GmbH

Accessories Electrical connection Cable gland Protection class Ex e, Ex d 7530-803 Page 7 Thread Cable Ø (mm) Materials Protection class (ATEX) Model M0 x,5 5... 8 Nickel plated brass II GD Ex e 058889 M0 x,5 0... 4 Nickel plated brass II GD Ex d 058885 / NPT 7,5...,9 Nickel plated brass II GD Ex d 058895 M0 x,5 9... 3 Stainless steel.457 (36 Ti) II GD Ex e 0589385 M0 x,5 7... Stainless steel.4404 (36 L) II GD Ex d 0589395 M0 x,5 0... 4 Stainless steel.4404 (36 L) II GD Ex d 0589387 M0 x,5 5... 9 Plastic (PA) 00854 M0 x,5 6... Plastic (PA) 00855 057075 () Drawings - Valve Dimensions in mm Projection/First angle 9 9,5 75,5 ~ 0 7 9 8,5 9,5 ~ 0 36 36 G /4 6 3 4 7 9 9,5 46,5 7 9 9, ~ 0 ~ 86 ~ 40 75 G / ~ 5,4 ~ 0 36 M4 x 6 mm deep without notice, the specifications given in this document. (006-50e) 05 Norgren GmbH en 5.4.304.07

Drawings - Solenoid Dimensions in mm Projection/First angle 38 7 46 79 3 86,5 4 53,5 49 5 63,5 59 96,5 34 7 M6 x,5 8 7 5 6 07 33 4 8,5 89 54,5 34 48 M6 x,5 8 4,5 5,5 M6 x,5 9,5 8 7 M6 x,5 9,5 8 7 64,5 7 3 4 0± 0, 9,5 63,5 73 can be indexed by 4x90 Ø 6 or 3 (with spacer tube) en 5.4.304.08 without notice, the specifications given in this document. (006-50e) 05 Norgren GmbH

7 70,5 8 / NPT Dimensions in mm Projection/First angle 0 53 4,5 3 4,5 + 59 56 63 84 33,5 6 4 9 Ø 6 or 3 (with spacer tube) 3 M0 x,5 or / NPT 4 Flying leads AWG ( long) Circuit diagrams 4 5 6 7 0 T T Cable gland C C A B C ø D Model B D B D M0 x,5 9 36 5... 8 058889 M0 x,5 6,5 7,5 9... 3 0589385 M0 x,5 4 39 0... 4 4 058885 A A / NPT 5 58 7,5...,9 4 058895 M0 x,5 4 39 7... 4 0589395 058895 only M0 x,5 0 34 0... 4 4 0589387 M0 x,5 9 36 5... 9 4 00854 M0 x,5 9 36 6... 4 00855 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. without notice, the specifications given in this document. (006-50e) 05 Norgren GmbH en 5.4.304.09