REDUCING ENERGY CONSUMPTION AND PEAK POWER IN BELGIUM With the support of: info@3e.eu www.3e.eu
PRESENTATION CONTENT Outline Objective Background Energy efficiency: examples in 3 sectors Residential: electric heating Tertiary: lighting Industry: electric pumps Summary Policy recommendations Conclusion Reducing energy consumption and peak power in Belgium 2
OBJECTIVE Nuclear phase-out is planned to start in 2015 Study wants to highlight the potential of energy efficiency to help achieving this decision while maintaining security of supply. High-level analysis for three concrete examples provide proof and concrete basis for action Quantitative analysis of energy reduction potential (over the year) Quantitative analysis of power reduction potential (during peak moments) Reducing energy consumption and peak power in Belgium 3
BACKGROUND Basic rule: generation must equal demand at all times Different types of generation: Base load plants (e.g. nuclear, cheap coal ) Flexible semi-baseload plants (e.g. gas) Peak plants (e.g. diesel generators) Must-run plants (e.g. wind) 54% Electricity production in Belgium per energy source [2009] 9% 29% Coal Petrol Gas Biomass Waste Nuclear Water Solar Wind Other Sources Load and Generation Indication of power generation with different sources in Belgium Must run RE Nuclear Coal Gas Peak System load 1 week (winter) Reducing energy consumption and peak power in Belgium 4
BACKGROUND Main problems in current and future power system: Provide backup power when there is not enough RE Reduce baseload when there is much RE Deal with fast variations with inflexible demand and generation Consequences of nuclear phase-out: Demand flexibility and new (peak) plants needed Base load is more flexible when there is less nuclear Demand flexibility and new flexible plants needed Reducing energy consumption and peak power in Belgium 5
BACKGROUND 14 000 Average, Maximum and Minimum load per hour for each month (2011) Load on Eliasystem [MW] 12000 10000 8000 6000 4000 2000 0 0 5 101520 1 6 111621 2 7 121722 3 8 131823 4 9 1419 0 5 101520 1 6 111621 2 7 121722 3 8 131823 4 9 1419 0 5 101520 1 6 111621 1 2 3 4 5 6 7 8 9 10 11 12 Daily average, minimum and maximum profile per month Summer peak: during morning Winter peak: during evening and much more important Reducing energy consumption and peak power in Belgium 6
BACKGROUND 14 000 Day with Maximum load (January 11, 2011) Breakdown of load profile 11/01/2011 (SLP RES, SLP non-res and rest) Total Residential SLP Total Non-Residential SLP Rest 12000 10000 10000 9000 8000 MW 8000 6000 4000 MW 7000 6000 5000 4000 3000 2000 0 1 2 3 4 5 6 7 8 9 101112131415161718192021222324 1 day (24h) 2000 1000 0 1 2 3 4 5 6 7 8 9 101112131415161718192021222324 1 day (24h) Peak load in 2011 was on January 11 (13.2 GW on Elia grid) Evening peak (~18h) mainly comes from residential customers, but can be reduced in any sector Reducing energy consumption and peak power in Belgium 7
ENERGY EFFICIENCY: EXAMPLES IN 3 SECTORS Electric consumption share (Energy balances 2009) 2% 1% 24% 27% 47% Industry Tertiary Residential Transport Agriculture Annual electricity consumption per region Annual electricity consumption per sector TWh 60 50 40 30 20 10 0 Flanders Wallonia Brussels Agriculture Transport Residential Tertiary Industry TWh 45 40 35 30 25 20 15 10 5 0 Brussels Wallonia Flanders Industry Tertiary Residential Transport Agriculture Reducing energy consumption and peak power in Belgium 8
RESIDENTIAL SECTOR: ELECTRIC HEATING Reducing energy consumption and peak power in Belgium 9
RESIDENTIAL SECTOR: ELECTRIC HEATING Looking at: Accumulation heating Direct complementary heating Enquete performed by IPSOS: 1018 households Spread over Flanders (58%), Brussels (10%), Wallonia (32%) Well distributed over age, gender, income level Reducing energy consumption and peak power in Belgium 10
RESIDENTIAL SECTOR: ELECTRIC HEATING Do you possess electric heating appliances (not for water, only for room heating)? 53% 47% Yes No 0% 20% 40% 60% 80% 100% What type of electric heating appliances do you have and how many of each? 0 1 2 3 4 More than 4 Direct heating appliance (heats as soon as you connect it) 2% 63% 25% 6% Accumulation heating appliance (stores heat during night at night tariff) 94% 3% 1% 2% 0% 20% 40% 60% 80% 100% Reducing energy consumption and peak power in Belgium 11
RESIDENTIAL SECTOR: ELECTRIC HEATING Specifically for the direct heating appliances as complementary heating: How many hours per day do you use them during winter days when it's freezing (e.g. if during the morning you use 2 devices during 2 hours, then the answer is 4) Morning (8.00-13.00h) Afternoon (13.00-18.00h) 49% 82% 40% 8% 10% 6% No use Less than 1h Start of the evening (18.00-20.00h) Evening (20.00-22.00h) 46% 49% 32% 30% 17% 13% 1-2h 2-4h 4-6h Night (22.00-8.00h) 80% 10% 6% More than 6h 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Would you be willing to stop using your device (or use it less) between 18h and 20h? 57% 24% 18% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Yes No I don't know Reducing energy consumption and peak power in Belgium 12
RESIDENTIAL SECTOR: ELECTRIC HEATING Results of enquete 53% of all belgians has one or more electric heating devices at home. Only 6% of the these possesses accumulation heating. 98% says to possess one or more direct electric heating devices. Direct heating devices are mostly used in the beginning of the evening (between 18h and 20h), in the morning and between 20h and 22h. 57% of the respondents is willing to reduce consumption or unplug the direct electric complementary heating during the period 18-20h. One out of 4 respondents is not willing to do this, while 18% does not know. Reducing energy consumption and peak power in Belgium 13
RESIDENTIAL SECTOR: ELECTRIC HEATING Results direct heating: Number of Belgian households (2008): 4 575 950 Households with direct electric heating: 52 % (=53%*98%) Average number of devices: 1.5 Average electric power: 1.5 kw Number of devices in Belgium: 3 573 433 Total installed power electric compl. heating: 5.36 GW Results accumulation heating: Number of Belgian households (2008): 4 575 950 Households with accumulation heating: 3 % (=53%*6%) Average consumption (VREG): 12 500 kwh Average installed power (100 m², 100 W/m²): 10 kw Number of accumulation heating systems: 137 279 Total installed power accumulation heating: 1.37 GW Reducing energy consumption and peak power in Belgium 14
2 000 RESIDENTIAL SECTOR: ELECTRIC HEATING Direct complementary heating Consumption profile of direct electric heating during winter peak day Result Enquete Smoothened* 1 500 MW 1 000 500 0 0-1 1-2 2-3 3-4 4-5 Assumption**: 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 Hour of the day 13-14 number of days (during day) <0 C 30 75% <5 C 132 30% <10 C 212 15% <15 C 319 0% 14-15 15-16 Use of devices 16-17 17-18 18-19 19-20 20-21 21-22 22-23 23-24 * Results of enquete are discrete (per block of hours). Therefore, the curve has been smoothened to represent a more realistic profile. ** This assumption is needed to transform the results of the enquete (in power consumption) to a total energy consumption over the year. Total energy consumption direct electric heating: 0.82 TWh 1.0% of Belgian electricity consumption 4.2% of residential electricity consumption 159 M electricity cost annually (calculated with 15/20 c /kwh for day/night) Total consumption during winter peak: 610 MW Reducing energy consumption and peak power in Belgium 15
RESIDENTIAL SECTOR: ELECTRIC HEATING Accumulation heating From SLP profiles winter peak day (difference between S21 and S22): 2500 2000 Estimation of accumulation heating usage on winter day 1 500 1 000 500 0 0-1 1-2 2-3 3-4 4-5 MW 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-16 16-17 17-18 18-19 19-20 20-21 21-22 22-23 23-24 Total energy consumption accumulation heating: 1.72 TWh 2.1% of Belgian electricity consumption 8.7% of residential electricity consumption 257 M electricity costs annually (calculated with 15 c /kwh for night) Total consumption during winter peak: 0 MW ( works at night) Reducing energy consumption and peak power in Belgium 16
RESIDENTIAL SECTOR: ELECTRIC HEATING Assumed conversions possible: 25% Total savings on peak day: Total electricity savings (accumulation + direct electrical heating) Direct heating (25%) Accumulation heating (25%) 0 0-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-16 16-17 17-18 18-19 19-20 20-21 21-22 22-23 23-24 -100 MW -200-300 -400-500 -600 Total energy savings: 0.64 TWh (3.2% of residential consumption) Peak reduction: 152 MW (1.15% of winter load peak) Annual electricity costs savings: 106 M Reducing energy consumption and peak power in Belgium 17
RESIDENTIAL SECTOR: ELECTRIC HEATING Serious point of attention, and not only in Belgium! Situation in France is even worse due to electric heating: In winter, demand is 65% higher than in summer, while for Belgium this is only 30% Electric heating in France consumes 34% of the winter peak Demand sensitivity per degree C: France: 2300 MW (=~2.3 % of peak power per C) Belgium: 80 MW (=~0.6 % of peak power per C) Source: Greenpeace Source: NegaWatt Reducing energy consumption and peak power in Belgium 18
TERTIARY SECTOR: LIGHTING Reducing energy consumption and peak power in Belgium 19
TERTIARY SECTOR: LIGHTING 14 12 Annual electricity consumption in the tertiary sector (Energy balances 2009 of each Region) Culture & sports Other services TWh 10 8 6 Health care Education Administration 4 2 0 Brussels Flanders Wallonie Banks/assuranc./services Hotels & restaurants Trade Reducing energy consumption and peak power in Belgium 20
TERTIARY SECTOR: LIGHTING Breakdown of electricity consumption in tertiary sector (Energy balance Brussels*) Lighting Airco, ventilation, cold Heating hot water Other Administration 35% Other services 25% Culture & sports 25% Health care 47% Education 69% Banks/assuranc./services 35% Trade 37% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% * The Brussels Energy balance (2009) is the only one with details on the split of electricity consumption. It is assumed that the shares in the other regions are similar. Reducing energy consumption and peak power in Belgium 21
TERTIARY SECTOR: LIGHTING Consumption profiles lighting (expert estimation 3E) % of capacity 100% 90% 80% 70% 60% 50% 40% 30% 20% Trade Hotels & restaurants Banks/assuranc./services Administration Education Health care 10% 0% 0-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-16 Hour of the day 16-17 17-18 18-19 19-20 20-21 21-22 22-23 23-24 Other services Culture & sports Reducing energy consumption and peak power in Belgium 22
TERTIARY SECTOR: LIGHTING Working hours lighting [1]: Office 2600 Education 2000 Health care 4000 Horeca 2600 Trade 2900 Industry 2400 Sports 3000 Possible saving: Average possible saving: 40% [2, 3, 4] Remaining potential: 75% [2] [1] Cijfers en tabellen 2007, SenterNovem, April 2007 [2] The European Lighting Industry Position on How to Maximise the Potential Benefits of European Policy on Energy Efficiency in Lighting, CELMA, 2008 [3] Groen Licht Vlaanderen 2020 [4] 3E Expert estimation Reducing energy consumption and peak power in Belgium 23
TERTIARY SECTOR: LIGHTING 0.90 0.80 0.70 0.60 Estimation of total savings on tertiary lighting (TWh per year & MW installed) 300 250 200 TWh 0.50 0.40 150 MW 0.30 100 0.20 0.10 50 0.00 0 Reducing energy consumption and peak power in Belgium 24
TERTIARY SECTOR: LIGHTING Savings on tertiary lighting on peak winter day (GW) 0.000 0-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-16 16-17 17-18 18-19 19-20 20-21 21-22 22-23 23-24 GW -0.100-0.200-0.300-0.400-0.500-0.600-0.700-0.800-0.900 Culture & sports Other services Health care Education Administration Banks/assuranc./services Hotels & restaurants Trade Total energy savings: 2.41 TWh (11.0% of tertiary consumption) Peak reduction: 812 MW (6.2% of winter load peak) Annual electricity cost savings: 362 M Reducing energy consumption and peak power in Belgium 25
INDUSTRY SECTOR: PUMPS AND VENTILATORS Reducing energy consumption and peak power in Belgium 26
INDUSTRY: EFFICIENT MOTOR SYSTEMS Annual electricity consumption in the industry (Energy balances 2009) TWh 30 25 20 15 10 5 Other industries Textile, leather & clothing Metal processing industry Mineral non-metal products Paper and publishing Food, drinks and tobacco Chemics Non-ferro 0 Flanders Brussels Wallonia Iron & steel Reducing energy consumption and peak power in Belgium 27
INDUSTRY: EFFICIENT MOTOR SYSTEMS 14 Annual electricity consumption in the industry (Energy balances 2009) 12 10 TWh 8 6 4 Wallonia Brussels Flanders 2 0 Iron & steel Non-ferro Chemics Food, drinks and tobacco Paper and publishing Mineral nonmetal products Metal processing industry Textile, leather & clothing Other industries Reducing energy consumption and peak power in Belgium 28
INDUSTRY: EFFICIENT MOTOR SYSTEMS Estimation of savings potential for pumps & ventilators 68 % of industrial consumption is used by motor systems [1] 38 % of this is used by pumps and ventilators [1] 75 % of these applications have a variable load [2] 50 % is estimated to be undeveloped potential [4] 29 % improvement in efficiency is possible by using: [3] frequency control more efficient motors better dimensioning of the systems 2.8 % of the industrial electricity consumption can be avoided [1] Reference Document on Best Available Techniques for Energy Efficiency (BREF), European Commission, February 2009 [2] Improving Pumping System Performance, A Sourcebook for Industry, Second Edition, U.S. Department of Energy s Industrial Technologies Program and Hydraulic Institute, May 2006 [3] Energy Efficient Motor Driven Systems, European Copper Institute, April 2004 [4] Very little information available Expert estimate based on Energy Efficiency makes a difference, ABB, November 2008 (15% realised potential) and on estimated progress since. As a reality check, the results are compared to Energy efficiency in Belgium, McKinsey, 2009, which calculates a potential of 3.06 TWh in Belgium industry, only via variable speed motors systems. Reducing energy consumption and peak power in Belgium 29
INDUSTRY: EFFICIENT MOTOR SYSTEMS Consumption profiles pumps & ventilators (expert estimation 3E) 100% 50% 0% Iron & steel Non-ferro Chemics Paper and publishing Mineral non-metal products 0-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-16 16-17 17-18 18-19 19-20 20-21 21-22 22-23 23-24 100% 50% 0% Metal processing industry Other industries 0-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-16 16-17 17-18 18-19 19-20 20-21 21-22 22-23 23-24 100% 50% 0% 0-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-16 16-17 17-18 18-19 19-20 20-21 21-22 22-23 23-24 Hour of the day Food, drinks and tobacco Textile, leather & clothing Reducing energy consumption and peak power in Belgium 30
INDUSTRY: EFFICIENT MOTOR SYSTEMS Estimation annual savings on pumps and ventilators (TWh per year & MW installed) 0.40 50 TWh 0.35 0.30 0.25 0.20 45 40 35 30 25 MW 0.15 0.10 0.05 20 15 10 5 0.00 Iron & steel Non-ferro Chemics Food, Paper and drinks andpublishing tobacco Mineral non-metal products Metal processing industry Textile, leather & clothing Other industries 0 Reducing energy consumption and peak power in Belgium 31
INDUSTRY: EFFICIENT MOTOR SYSTEMS Savings on pumps & ventilators on peak winter day (GW) GW 0.00-0.02-0.04-0.06-0.08-0.10-0.12-0.14-0.16-0.18-0.20 Other industries Textile, leather & clothing Metal processing industry Mineral non-metal products Paper and publishing Food, drinks and tobacco Chemics Non-ferro Iron & steel Total energy savings: 1.08 TWh (2.8% of industrial consumption) Peak reduction: 151 MW (1.1% of winter peak) Annual electricity cost savings: 108 M Reducing energy consumption and peak power in Belgium 32
SUMMARY & CONCLUSIONS Reducing energy consumption and peak power in Belgium 33
SUMMARY: ENERGY SAVINGS Residential electric heating: 0.63 TWh Tertiary lighting: 2.41 TWh Industrial motors: 1.08 TWh 4.13 TWh Total savings: 4.13 TWh ~5.0 % of Belgian electricity consumption ~576 M electricity cost savings each year Reducing energy consumption and peak power in Belgium 34
SUMMARY: REDUCTION OF THE WINTER PEAK Possible reduction of winter peak Green line - savings on electrical heating Blue line - savings on pumps&ventilators Red line - savings on tertiary lighting Load Elia (11 January 2011, max of each hour in MW) 14 000 12 000 10000 8000 14 000 Zoom on peak hours MW 6000 4000 MW 13000 12000 11000 2 000 0 10000 16-17 17-18 18-19 19-20 20-21 0-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-16 16-17 17-18 18-19 19-20 20-21 21-22 22-23 23-24 Hour of the day The three measures can significantly reduce the winter peak load. Reducing energy consumption and peak power in Belgium 35
SUMMARY: REDUCTION OF THE WINTER PEAK Reduction of winter peak load 14000 12000 13 208 12 093 10 000 MW 8000 6000 4 000 2 000 0 Peak load Reduction by pumps & ventilators Reduction by lighting Reduction by electric heating Final Reduction of winter peak with 1116 MW (8.5%) possible (with 3 measures). Energy efficiency offers important opportunities for controlling the peak consumption! Reducing energy consumption and peak power in Belgium 36
SUMMARY: POWER SAVINGS ON WINTER DAY Reduction of consumption on peak winter day by the three measures 0-200 Savings on pumps & ventilators Savings on tertiary lighting Savings on electric heating 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24-400 MW -600-800 -1 000-1 200-1 400 Reducing energy consumption and peak power in Belgium 37
SUMMARY OF SAVINGS Share of each measure Energy savings (4.1 TWh = 5.0% of total BE consumption) 35% 13% 52% Savings on residential electric heating Savings on tertiary lighting Savings on industrial pumps and ventilators 19% 12% 69% Peak reduction (1116 MW = 8.5% of peak) Savings on residential electric heating Savings on tertiary lighting Savings on industrial pumps and ventilators Electricity cost savings (total 576 M /year) 26% 17% 58% Savings on residential electric heating Savings on tertiary lighting Savings on industrial pumps and ventilators Reducing energy consumption and peak power in Belgium 38
SUMMARY OF SAVINGS Costs and profits Assumptions average payback: Replacing electric heating: 5y Reducing tertiary lighting consumption: 4y Optimisation of pumps & ventilators: 2.5y Financial assumptions: 4% discount factor for residential sector 10% discount factor for tertiary and industry 2% annual rise of electricity price 15 years depreciation period Cash flow calculation: 2.07 bn EUR investment costs 3.24 bn EUR total profits Each invested EUR brings 1.56 EUR benefits! Cumulative Cash flow [ ] 4000000000 3000000000 2000000000 1000000000 0-1000000000 -2000000000 Cumulative Cash flow estimation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Reducing energy consumption and peak power in Belgium 39
POLICY RECOMMENDATIONS (1) Energy efficiency urgently needs more policy attention! Important economic savings possible with low payback times Supports the Belgian power system and reduces peak load Reduces dependency on fuel imports and increases competitiveness of our industry Helps reaching the 2020 targets of EE, RE and CO2 Concrete actions: Develop large-scale program to replace electric heating with attention for the social aspect Stimulate audits and relighting in the tertiary sector Further an ambitious energy savings policy for the industry (focusing on innovation while keeping the long term transition towards a carbon-free economy in mind) Reducing energy consumption and peak power in Belgium 40
POLICY RECOMMENDATIONS (2) The three measures studied are only examples. Energy efficiency has a lot more potential, e.g.: Energy performant appliances (+ phase-out of old appliances) Efficient lighting in residential and industry sectors Reduce standby consumption Efficient motors in tertiary and residential applications (e.g. circulation pumps heating) Etc. Find solutions for financing Large potential is not developed, amongst others because of financing problems (e.g. economic crisis, owner vs tenant, low payback times demanded in industry etc.) Well developed ESCO systems, financing schemes, etc. can help Support and incentivise flexibility: Flexibility is key in a future power system with high penetration of renewables Electricity contracts can be based more on hourly pricing gives incentive to the industry Provide information for voluntary reductions or shifts (e.g. during peak hours, boil water on cooking fire instead of with water boiler, use gas oven instead of microwave, etc.) Incentivise economically viable storage options (e.g. heat storage with CHP or heat pump ) Reducing energy consumption and peak power in Belgium 41
EXAMPLE: VOLUNTARY REDUCTION AT PEAK MOMENTS? Not an illusion: example of Earth Hour Earth Hour: world-wide action by WWF to switch off lighting at 8:30 PM (every March) Impact in Belgium (press releases Elia): 2010: From 18h30 onwards, the consumption was ~200 MW less than the forecast for a normal Saturday, at some moments the difference was up to 300 MW participants have ancipated. At 20h30, the official start, the consumption was 175 MW lower than the forecast. 2011: The whole day the consumption was 350 to 400 MW lower than forecasted for a normal Saturday, because of the sunny weather. From 19h onwards, the effect was enforced by an extra 200-250 MW participants have anticipated. At 20h30, the official start, the consumption was ~550 MW lower than the forecast (& impact of PV is much less at this hour) Voluntary energy reductions can help to reduce the peak consumption and should not be underestimated IPSOS enquete proved that 57% of people with electric heating is willing to shift or reduce the consumption Reducing energy consumption and peak power in Belgium 42
CONCLUSIONS Savings of three measures have been investigated: Residential sector: Replacing electric heating (direct & accumulation) Tertiary sector: More efficient lighting Industry sector: More efficient motors systems in pumps & ventilators Total estimated savings: Energy: ~4.13 TWh (5.0% of BE consumption) Peak reduction: ~1116 MW (8.5% of winter load peak) Annual costs: ~576 M Investment of 2.06 bn EUR with payback of ~4 years Total profit over 15 years = 3.24 bn EUR Taking energy efficiency measures can significantly support the Belgian energy system in a cost-effective way! Reducing energy consumption and peak power in Belgium 43