DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

Similar documents
High level of gas tightness: approx. 6 x 10-3 mbar x l/s (not tested in serial production) Long product life

CG PTFE Diaphragm Liquid Transfer Pump

Solenoid valves 2/2-way direct-operated Type EV210A

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

MEMBRANE VACUUM MINI PUMPS

Assisted lift operated 2/2-way solenoid valves Type EV250B

Vacuum drying oven for non-flammable solvents

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

ON-VEHICLE INSPECTION

Technology for Vacuum Systems. Instructions for use

Why and How we Use Capacity Control

Compact pressure switch Flameproof enclosure Ex d Model PCA

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation

servo-controlled 3-WaY vacuum solenoid valves WiTH

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

Mechanical shaft seal types and sealing systems

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Medical Air Systems: Scroll

EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS ARS PAGE 1 OF 5

HYDROSTATIC TEST PUMPS

ECOCIAT. Domestic hot water heat recovery unit

Solenoid valves Type EVU

Excellence through Versatility

REFRIGERATED COMPRESSED AIR DRYERS

ABEL EM. Electromechanical. Membrane Pumps. The economical alternative. From the reciprocating positive displacement pump specialist

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A

MAC-120HE-01 Air-Cooled Chiller

40 Vacuum drying ovens

3/2-way Mini Solenoid Valve

Adsorption air dryers ADS 1 215

Refrigerated Air Dryers. Catalogue

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

KNC Model 3666 Automatic Pressure Calibration System

Rotary screw compressors kw 5,5 7, , bar MODULO

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Combi switchbox with integrated 3/2 way pilot valve

Compact pumps from the wastewater experts. FLYGT 3045, 3057, Power range kw.

marine/bespoke split applications

clean and quiet dental

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Kompressoren. Adsorption Dryer AD

Transformer oil cooler ALFA A02

A/C refrigerant system, overview

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

IV. Rear Mount System

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Workshop Compressors CLASSIC Series

4 Posiflow Proportional Solenoid Valves

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Refrigeration Air Dryers. Catalogue

BASIS RANGE TMB SERIES

ThermoSorb Desiccant Dryers

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

VACUUM HEATING AND DRYING OVENS Gentle and safe

Test Code: 8297 / Version 1

Pressure transmitter For general industrial applications Model A-10

Atlas Copco Stationary air compressors

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

SISTO-16TWA/HWA/DLU. Type Series Booklet

Single sub-base valve

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

3/2-way Solenoid Valve, direct-acting, NC or NO

The On-Load Tap-Changer for Maximum Switching Frequency More Switching Operations without Needing Maintenance.

Series IDU/IDF. Refrigerated Air Dryer

Fast closing valve Series 75

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine.

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Condensate water pump with neutralisation system

Steam Jet Vacuum Pumps

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Flygt 3068, 50Hz. Technical Specification

Pressure sensors for automotive HVAC systems

MOLECULAR DRAG PUMPS MDP SERIES

Check Valves & Actuated Valves

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

Hydraulic control unit series

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

LOBOY 16 AIR CONDITIONERS

System 8. ü ( System 8

Application Engineering

ThermoStar Refrigeration Air Dryers

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

GE Druck. Hand Pumps Pneumatic/Hydraulic hand pump Product Guide. Pneumatic hand pumps from -1 to 60 bar. Hydraulic hand pumps from 0 to 1000 bar

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

ELECTROMAGNETIC FLOWMETER COMPACT

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Operation Manual. Diaphragm pumps 1-headed MPC 301 E

Transcription:

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS Data sheet e 32 N 35.1 ANE with IP 2 motor Concept The diaphragm pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and down its central point by means of an eccentric. In this way the medium is trans ferred using automatic valves. Thanks to the KNF modular system, the parts used to transfer the gases can be made from materials with varying degrees of durability. The customer has a choice of pump drives ranging from a selection of motors to explosion-proof models. N 35.2 ANE with IP 44 motor Features Pure transfer, evacuation and compression of air, gases and vapors No contamination of the media due to oilfree operation Maintenance-free Corrosion resistant models High level of gas tightness: approx. 6 x 1-3 mbar x L/s (not tested in serial production) Long product life Very quiet and little vibration Cool running motor even when in constant use Ready for assembly Can operate in any installed position Areas of use The diaphragm pumps offer a high level of performance despite their small size, as well as an excellent price performance ratio. They are required especially in the fields of analysis, medicine and production technology. The pumps are used for transfering, compressing and evacuating air, gases and vapors, taking samples (even liquids in a ) and evacuating and compressing vessels. (L/min) (mbar absolute) atm. Pressure N 35.1 ANE (IP 2) 55 1 24. N 35.1 ANE (IP 44) 55 1 24.7 N 35.2 ANE (IP 2) 55 58 24. N 35.2 ANE (IP 44) 55 58 24.7 N 35.3 ANE (IP 2) 3 13 24. N 35.3 ANE (IP 44) 3 13 24.7 Weight (lbs)

N 35.1 _ with IP 2 Motor at atm. N 35.1 ANE 55-1 N 35.1 AVE 55-1 N 35.1 ATE 49.5-1 N 35.1 SNE 55-1 N 35.1 SVE 55-1 N 35.1 STE 49.5-1 1) Liter at STP Protection class IP 2 Voltage (V) 23 Frequencies (Hz) 5 Power P1 (W) 32 lmax (A) 1.8 Pump head Diaphragm Valves N 35.1 ANE Aluminum CR Stainless steel N 35.1 AVE Aluminum FPM Stainless steel N 35.1 ATE Aluminum PTFE-coated Stainless steel N 35.1 SNE Stainless steel CR CR N 35.1 SVE Stainless steel FPM FPM N 35.1 STE Stainless steel PTFE-coated PTFE N 35.1 _ with IP 44 Motor at atm. N 35.1 ANE 55-1 N 35.1 AVE 55-1 N 35.1 ATE 49.5-1 N 35.1 SNE 55-1 N 35.1 SVE 55-1 N 35.1 STE 49.5-1 Protection class IP 44 Voltage (V) 23 Frequencies (Hz) 5 Power P1 (W) 36 lmax (A) 2.1 Pump head Diaphragm Valves N 35.1 ANE Aluminum CR Stainless steel N 35.1 AVE Aluminum FPM Stainless steel N 35.1 ATE Aluminum PTFE-coated Stainless steel N 35.1 SNE Stainless steel CR CR N 35.1 SVE Stainless steel FPM FPM N 35.1 STE Stainless steel PTFE-coated PTFE N 35.1 A_E (IP 2) N 35.1 A_E (IP 44) N 35.1 S_E (IP 2) N 35.1 S_E (IP 44) N 35.1 ANE (IP 2) N 35.1 ANE (IP 44) 6 6 5 4 3 2 1 N 35.1 AT/ST: 5 4 3 2 1 N 35.1 AT/ST: 1.45 2.9 5.81 8.7 11.6 14.69 1.45 2.9 5.81 8.7 11.6 14.69 mbar mbar

N 35.2 _ with IP 2 Motor at atm. N 35.2 ANE 55 58.1 - N 35.2 AVE 55 29.1 - N 35.2 ATE 49.5 58.1 - N 35.2 SNE 55 58.1 - N 35.2 SVE 55 29.1 - N 35.2 STE 49.5 58.1 - N 35.2 _ with IP 44 Motor at atm. N 35.2 ANE 55 58.1 - N 35.2 AVE 55 29.1 - N 35.2 ATE 49.5 58.1 - N 35.2 SNE 55 58.1 - N 35.2 SVE 55 29.1 - N 35.2 STE 49.5 58.1 - Protection class IP 2 Voltage (V) 23 Frequencies (Hz) 5 Power P1 (W) 32 lmax (A) 1.8 Pump head Diaphragm Valves N 35.2 ANE Aluminum CR Stainless steel N 35.2 AVE Aluminum FPM Stainless steel N 35.2 ATE Aluminum PTFE-coated Stainless steel N 35.2 SNE Stainless steel CR CR N 35.2 SVE Stainless steel FPM FPM N 35.2 STE Stainless steel PTFE-coated PTFE Protection class IP 44 Voltage (V) 23 Frequencies (Hz) 5 Power P1 (W) 36 lmax (A) 2.1 Pump head Diaphragm Valves N 35.2 ANE Aluminum CR Stainless steel N 35.2 AVE Aluminum FPM Stainless steel N 35.2 ATE Aluminum PTFE-coated Stainless steel N 35.2 SNE Stainless steel CR CR N 35.2 SVE Stainless steel FPM FPM N 35.2 STE Stainless steel PTFE-coated PTFE N 35.2 A_E (IP 2) N 35.2 A_E (IP 44) N 35.2 S_E (IP 2) N 35.2 S_E (IP 44) N 35.2 ANE (IP 2) N 35.2 ANE (IP 44) 6 Pressure 6 Pressure 5 5 4 3 2 1 N 35.2 AV/SV: max. 29 N 35.2 AT/ST: 4 3 2 1 N 35.2 AV/SV: max. 29 N 35.2 AT/ST: 7.25 14.5 21.75 29.1 36.26 43.51 5.76 58.2 7.25 14.5 21.75 29.1 36.26 43.51 5.76 58.2

N 35.3 _ with IP 2 Motor 1) Liter at STP at atm. Protection class IP 2 Voltage (V) 23 Frequencies (Hz) 5 Power P1 (W) 23 lmax (A) 1.5 N 35.3 ANE 3-13 N 35.3 AVE 3-13 N 35.3 ATE 27-2 N 35.3 SNE 3-13 N 35.3 SVE 3-13 N 35.3 STE 27-2 Pump head Diaphragm Valves N 35.3 ANE Aluminum CR Stainless steel N 35.3 AVE Aluminum FPM Stainless steel N 35.3 ATE Aluminum PTFE-coated Stainless steel N 35.3 SNE Stainless steel CR CR N 35.3 SVE Stainless steel FPM FPM N 35.3 STE Stainless steel PTFE-coated PTFE N 35.3 _ with IP 44 Motor at atm. Protection class IP 44 Voltage (V) 23 Frequencies (Hz) 5 Power P1 (W) 26 lmax (A) 2. N 35.3 ANE 3-13 N 35.3 AVE 3-13 N 35.3 ATE 27-2 N 35.3 SNE 3-13 N 35.3 SVE 3-13 N 35.3 STE 27-2 Pump head Diaphragm Valves N 35.3 ANE Aluminum CR Stainless steel N 35.3 AVE Aluminum FPM Stainless steel N 35.3 ATE Aluminum PTFE-coated Stainless steel N 35.3 SNE Stainless steel CR CR N 35.3 SVE Stainless steel FPM FPM N 35.3 STE Stainless steel PTFE-coated PTFE N 35.3 A_E (IP 2) N 35.3 A_E (IP 44) N 35.3 S_E (IP 2) N 35.3 S_E (IP 44) N 35.3 ANE (IP 2) N 35.3 ANE (IP 44) 6 6 5 4 3 2 1 N 35.3 AT/ST: max. 2 mbar abs. max. delivery 27 L/min Flow capacity l/min 5 4 3 2 1 N 35.3 AT/ST: max. 2 mbar abs. max. delivery 27 L/min 1.45 2.9 5.8 8.7 11.6 14.69 1.45 2.9 5.8 8.7 11.6 14.69

Technical Information 113 8 Pump down time for 2 L receiver Technical details Option N 35.1/.2/.3.9 E Pump head guaranteed gas-tight: leakage rate less than 6 x 1-3 mbar x L/s in the material combinations AN, AV, SN, SV, ST. 6 mbar 4 2 N 35.1 ANE N 35.3 ANE 1 2 3 4 5 min Accessories Description Order No. Details Silencer/filter 352 Fine control valve, side 482 with gauge Fine control valve, suction side 354 with gauge Pressure relief valve 4761 58.1 Hose connector 362, for tube ID 9 Hose connector, stainless steel 2234, for tube ID 9 Head connections N 35.1 Heads with suction side in parallel N 35.2 Heads with side in parallel N 35.3 Heads in series

HINTS ON FUNCTION and INSTALLATION Function of KNF diaphragm pumps and compressors An elastic diaphragm is moved up and down by an eccentric (see illustration). On the down-stroke it draws the air or gas being handled through the inlet valve. On the up-stroke the diaphragm forces the medium through the exhaust valve and out of the head. The compression chamber is hermetically separated from the drive mechanism by the diaphragm. The pumps transfer, evacuate and compress completely oil-free. Hints on installation and operation Range of use: Transferring air and gases at temperatures between +5 C and +4 C. Permissible ambient temperature: between +5 C and +4 C. Please check the compatibility of the materials of the pump head, diaphragm and valves with the medium. The KNF product line contains pumps suitable for pumping aggressive gases and vapors - please contact us. The standard pumps are not suitable for use in areas where there is a risk of explosion. In these cases there are other products in the KNF program - please ask us for details. The pumps are not designed to start against or ; when a pump is switched on the in the suction and lines must be atmospheric. Pumps that start against or are available on request. To prevent the maximum operating being exceeded, restriction or regulation of the air flow should only be carried out in the suction line. Components connected to the pump must be designed to withstand the pneumatic performance of the pump. Install the pump so that the fan can draw in sufficient cooling air. Fit the pump at the highest point in the system, so that condensate cannot collect in the head of the pump - that prolongs working-life. KNF Neuberger Inc. 2 Black Forest Road Trenton, NJ 8691 Tel. (69) 89-86 Fax (69) 89-2838 supportusa@knf.com www.knfusa.com KNF reserves the right to make technical changes. KNF 7/216