RH/T measurement instruments for HVAC applications. HygroMaxx R / S / M

Similar documents
Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Duct Humidity Transmitter

Digital inductive conductivity transmitter

Capteur température et humidité pour HVAC

How To Use A Ds340 (Dsp)

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

HARTING Ethernet Cabling 4-poles Overview

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Long Distance Industrial Wireless Transmitters and Receivers

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Heating oven with mechanical convection

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Contents. Document information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Material test chamber with mechanical convection

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

T U R B I N E G A S M E T E R

Instruction Manual. T3111 T3111L T3111P T3111Ex

Rense Product Range. Customized Humidity Solutions. Rense Product Range

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Temperature & Humidity SMS Alert Controller

API Marine. BMS Presentation. Ballast Measurement Systems

Incubator with mechanical convection

How To Use A Gizmo 2.5 (Gizmo) With A Power Supply (Power Supply) And Power Supply For A Long Time (Power Source) (Power Cell) (Gigabone) (Microphone) (

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Battery Powered Thermal Mass Flow Meters for Gases

ATL Fuel Level Sender Probes

Multifunction HVAC and IAQ Meter

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

User Manual Weather station V 0.2

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

How To Use A Flowmeter

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Thermal Mass Flow Meters and Controllers for Gases

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Heating oven with mechanical control

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Rotary actuators Rotary wing drives Series RAK. Brochure

Battery Powered Thermal Mass Flow Meters for Gases

Vaisala Weather Transmitter WXT510 The Most Essential of Weather

400 Series - Mini USB Buccaneer

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Mini USB and USB 2.0-IP67 Connector System

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Pressure transmitter For general industrial applications Model A-10

FIREDEX Conventional Fire Panels

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

Electronic Control Devices The European Product Catalogue 2007

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

ALARMLINE ANALOGUE Linear Heat Detection System

KNX R. Rain Sensor. Installation and Adjustment

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Model SRMD Setra Remote Monitoring Display

Vacuum drying oven for non-flammable solvents

Processor. Installation Guide

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

A99B Series Temperature Sensors

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Electromagnetic Flow Meter

HARTING Ethernet Cabling 8-poles Overview

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

4-Channel Thermometer / Datalogger

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

PRODUCT PROFILE FEATURES

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

PIEZOMETER AIRFLOW MEASURING RING

AN588 ENERGY HARVESTING REFERENCE DESIGN USER S GUIDE. 1. Kit Contents. 2. Introduction. Figure 1. Energy Harvesting Sensor Node

Repeaters and Mimics Data Sheet

Standard Buccaneer - Ethernet

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Toroidal Conductivity Sensor

1. Overview. WPT Wireless Range Tester Kit User Manual Doc No Rev Components Prerequisites for Site Survey

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

HD29371T - HD29V371T HD403TS - HD4V3TS HD103T.0

PD 100A. Printing data system

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Battery Powered Digital Mass Flow Meters for Gases

T7560A,B,C Digital Wall Module

Buckeye Detection Systems Fixed Detection Systems Application Survey

Magnetic proximity switches

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Pressure Dew Point Probe / Application Information

COMBIMASS. Technical Data COMBIMASS eco-bio +

Transcription:

RH/T measurement instruments for HVAC applications HygroMaxx R / S / M High performance measuring instrument with large LCDisplay for air relative humidity and temperature. For installations in rooms or ducts. The digital capacitive humidity measurement cell in conjunction with a newly developed sensor technology, enable this device to be used in various applications for measuring climatic parameters. Operation is effected via 3 keys and an intuitive menu. The HygroMaxx transmits 2 analogue outputs for relative humidity and temperature. These can be scaled as required. Optimal integration into a control system can therefore be achieved. The HygroMaxx is available in different versions for room and duct measurement. Rel. air humidity : 0...100% RH Temperature : -20...80 C (sensor) -5...60 C (transmitter) Accuracy : ± 2.0% RH at 10...80% RH and 0...50 C ± 0.5 K at 0...50 C / 0.8 C at -20...80 C Signal output : 2 analog outputs U/I (switch able) U :0...10V : 2...10V / I : 0...20mA : 4...20mA freely scalable output-characteristic curve operated by integrated configuration menu Display : 2 line display RH and Temp. Contemporaneously, error/menu control display, Dimensions 60x30 mm Functions : unit switch-over C / F, scalable analog outputs, adjustment at 3 humidity points / 1 temperature point, moving average display ¼, 1, 3 hours, password protection Adjustment : checkable and adjustable at any time at 3 RH points Measurement principle : using the proven Novasina humidity standards SAL-SC digital capacitive CMOS-Sens technology HygroMaxx R/S/M For monitoring and controlling for HVAC applications Humidity/temperature transmitter for HVAC and process controls with local LCDisplay. The HygroMaxx product series have been developed following the newest technology in monitoring and controlling in the HVAC sector. These products represent an ideal combination of performance and price. The new sensor technology, the configuration possibilities and the robust design set a new standard in the HVAC field. Thanks to the new design conception, these instruments are easy for installation and maintenance. Integrated menu functions facilitate the start up, service resp. the RH adjustment with the Novasina SAL-SC humidity standards. Furthermore this product can be easily customised and adapted to specific needs (OEM versions). Typical applications: HVAC process-control and -monitoring Paper and textile manufacturing and handling Controls and monitoring systems in labs and metrology rooms Monitoring of industrial combustion processes Storage and archive monitoring in museums and libraries Storage systems, cooling rooms etc. in the food & pharma industry Measurement instrument HygroMaxx: Dimension : 110 x 118 x 50mm Power supply : 24 V DC ± 10% Probe length S-type : diam.13 x 58 mm Probe length R-type: diam.13 x 250 mm Humidity measurement: CMOS-Sens technology, digital capacitive Measurement range : 0...100 % RH Reproducibility : ± 1.0 % RH Max.accuracy (standard) : ± 3.0 % RH Max.accuracy (calibrated) : ± 1.5 % RH Temperature measurement: digital PN barrier silicon layer Measurement range : -20...80 C Reproducibility : +/- 0.1 K Accuracy : +/- 0.5 K (10...30 C) Accuracy : +/- 0.8 K (-20...80 C) Sensor Checks SAL-SC: Humidity standards based on saturated salt solutions in plastic cylindrical containers. For multiple use, with Cellgard humidity permeable membrane. For values: 11%, 33%, 53%, 75%, 90% RH Version : V 4.0. Air-catalogue 2007 page 25 / 25

HVAC transmitter system HygroMaxx 252 3054 HygroMaxx S HVAC and industry transmitter system HygroMaxx R / S / M HygroMaxx S Humidity/Temperature measurement instruments for rooms HVAC transmitter with stylish designed, robust, twopart plastic housing. Ideal for room measurements, monitoring and controlling of climatic parameters. 24 VDC power supply (no galvanic separation), 2 analogue outputs (U or I) for temperature and relative air humidity. The cable entry easily made via the housing s underside. The device is fixed with 4 screws to the wall. The big LCDisplay allows a good readability, even from the distance. Various menu functions and adjustment of RH and T as well as the analogue outputs and a password protection complete this versatile instrument. Transmitter HygroMaxx S: Dimension: 110 x 118 x 50mm Probe: diameter 13 x 58 mm : 220 g Power supply: 24 VDC + 10% Power consumption: DC max. xx W Outputs: 2 x analog U/I 0...10V / 2...10V 0...20mA / 4..20mA Meas.range: 0...100% /-20...+80 C (only sensor) Units: RH / C or F Including mounting accessories and operating manual Optional: factory calibration RH/T 252 3129 HygroMaxx R HygroMaxx R Humidity/Temperature measurement instruments for ducts HVAC transmitter with aesthetic design, robust, twopart plastic housing. Ideal for duct measurements, monitoring and controlling of climatic parameters. 24 VDC power supply (no galvanic separation), 2 analogue outputs (U or I) for temperature and relative air humidity. The cable entry is easily made via the housing s underside. The device is fixed directly or with a mounting flange to the air duct. The big LCDisplay allows a good readability, even from the distance. Various menu functions as adjustment of RH and T as well as the analogue outputs and a password protection complete this versatile instrument. Transmitter HygroMaxx R: Dimension: 110 x 118 x 50mm Probe: diameter 13 x 250 mm : 280 g Power supply: 24 VDC + 10% Power consumption: DC max. xx W Outputs: 2 x analog U/I 0...10V / 2...10V 0...20mA / 4..20mA Meas.range: 0...100% /-20...+80 C (only sensor) Units: RH / C or F Including mounting accessories and operating manual Optional: factory calibration RH/T 252 3130 HygroMaxx M HygroMaxx M Humidity/Temp.measurement instrument with remote probe HVAC transmitter with aesthetic design, robust, twopart plastic housing. The remote sensor probe with 3m cable makes this instrument ideal for monitoring and controlling of processes, where a high flexibility is required. 24 VDC power supply (no galvanic separation), 2 analog outputs (U or I) for temperature and relative air humidity. The cable entry is easily made via the housing s underside. The device is fixed with 4 screws to the wall. The big LCDisplay allows a good readability, even from the distance. Various menu functions as adjustment of RH and T as well as the analogue outputs and a password protection complete this versatile instrument. Transmitter HygroMaxx M: Dimension: 110 x 118 x 50mm Probe: diameter 13 x 250 mm : 200 g Power supply: 24 VDC + 10% Power consumption: DC max. xx W Outputs: 2 x analog U/I 0...10V / 2...10V 0...20mA / 4..20mA Meas.range: 0...100% /-20...+80 C (only sensor) Units: RH / C or F Including mounting accessories and operating manual Optional: factory calibration RH/T Fühlerlänge 230 mm: 252 3133 SensMaxx 13 3m Kabel SensMaxx 13 for HygroMaxx M version Small and robust humidity/temperature sensor with stainless steel housing including membrane protection filter with IP65 protection. Diameter 13mm including 3m shielded cable. Please follow the specific installation manual for connection to the transmitter unit. Options: 1 pc flange for duct mounting 1 pc flange for wall mounting SensMaxx 13 : Dimension: diameter 13 x 150mm : 80 g : stainless steel Measurement: RH-digital capacitive Temp. PN silicon Hum. meas. cell: CMOS Sens Connection: 5-pole cable 3m with EMC shield Protection: membrane filter (IP 65) Meas.range: 0...100% / -20...+80 C Version : V 4.0. Air-catalogue 2007 page 26 / 26

Accessories to HygroMaxx 252 4468 Wandmontage Clip Accessories to HygroMaxx Wall mounting kit 13 mm Wall mounting clips (2 pcs) for the fixation of the SensMaxx 13 probes to walls with M4 wood, plastic or metal screws. Clips can be used several times. -> Diameter fixation range: diam. 12...16 mm Wall mounting clip SensMaxx: : polycarbonate Quantity : 2 pcs Installation range diam.12...16 mm : 15 g 111 5343 Kanalmontage-Kit Duct mounting kit Duct mounting flange (1 pc) for SensMaxx 13 probes. For easy and tight mounting to ducts or through walls/ceilings including a sealing O-ring. The installation is made with 3 screws. The 13 mm tight flange aperture tolerates a max. overpressure of 3 bars. The sensor probe can be removed at any time for adjustment. -> Diameter fixation range: diam. 10...14 mm Duct mounting kit SensMaxx: Dimension : 60 x 20 mm : 30 g Installation range : diam. 9 14 mm 111 6812 Wetterschutzschild Weather shield for outdoor applications An effective protection against wind, rain, snow and direct sunlight for the HS sensor. Ideal for meteorological measurements in the range 20...+80 C. The shield can be quickly and easily attached to a 25.. 50 mm diameter post. The shield is delivered with all of the necessary mounting materials. Weather shield for SensMaxx: Dimensions : 270 x 220 x 120 mm : 650 g : UV stabilised, thermoplastic slats, painted steel construction 111 0885 -> SAL-SC 11% rf 111 0855 -> SAL-SC 33% rf 111 0857 -> SAL-SC 53% rf 111 0859 -> SAL-SC 75% rf 111 0896 -> SAL-SC 90% rf Sensor-Checks SAL-SC (rh standards) Humidity standards based on saturated salt solutions in plastic cylinders with moisture permeable membranes. Each salt is delivered in a well-sealed box. Sensor Checks SC are obtainable for the following values (at 25 C) : SAL-SC 11.3 % rh colour white SAL-SC 32.8 % rh colour blue SAL-SC 52.9 % rh colour green SAL-SC 75.3 % rh colour purple SAL-SC 90.1 % rh colour white Humidity values in the temperature range 15... 30 C: 11.3... 11.3% rh 33.3... 32.4% rh 55.9... 51.4% rh 75.6... 75.1% rh 90.9... 89.9% rh The precision corresponds to the Greenspan Report 1977 typically +/- 0.3 % rh : 90 g 111 1044 -> SAL-SC 11% rf EU 111 1037 -> SAL-SC 33% rf EU 111 1040 -> SAL-SC 53% rf EU 111 1035 -> SAL-SC 75% rf EU 111 1032 -> SAL-SC 90% rf EU Sensor-Checks SAL-SC EU with European certificate Humidity standards based on saturated salt solutions in plastic cylinders with moisture permeable membranes. Each salt is delivered in a well-sealed box. Sensor Checks SAL-SC are obtainable for the following values (at 25 C) : SAL-SC 11.3 % rh colour white SAL-SC 32.8 % rh colour blue SAL-SC 52.9 % rh colour green SAL-SC 75.3 % rh colour purple SAL-SC 90.1 % rh colour white Internationally accredited laboratory All Novasina humidity standards can also be supplied with an internationally recognised certificate from an accredited European laboratory (UKAS England). : 90 g Version : V 4.0. Air-catalogue 2007 page 27 / 27

Accessories to HygroMaxx 111 7847 Check set (standard) 111 7841 Empty case for set Set with 5 Sensor-Checks SAL-SC Humidity standards based on saturated salt solutions in plastic cylinders with moisture permeable membranes. Each salt is delivered in a well-sealed box. Sensor Checks SAL-SC are obtainable for the following values (at 25 C) : SAL-SC 11.3 % rh colour white SAL-SC 32.8 % rh colour blue SAL-SC 52.9 % rh colour green SAL-SC 75.3 % rh colour purple SAL-SC 90.1 % rh colour white Case with all 5 Sensor Checks from 11 to 90%rh: Humidity values in the temperature range 15... 30 C : 11.3... 11.3% rh 33.3... 32.4% rh 55.9... 51.4% rh 75.6... 75.1% rh 90.9... 89.9% rh The precision corresponds to the Greenspan Report 1977 typically +/- 0.3 % rh : 900 g 110 7345 Adapter CH SAL-SC Sensor check adapter CH for sensors with diameter 13 mm This adapter is needed for calibration of a system with sensor diameter 13 mm. It ensures an airtight fixation of a SAL-SC check to the sensor top (measurement cell area). It reduces the diameter of 20 mm to 13 mm and ensures an airtight seal. -> The adapter should be first mounted on the sensor top and then putted the SAL-SC check on it. Both seals should be carefully checked, leaks will bias the calibration. CH adapter to SAL-SC salts for sensors with diameter 13 mm: Dimensions : 30 x 13 mm : Polycarbonate, rubber : 5 g 111 1302 Styrofoam box for SC Thermal insulation styrofoam box For the SAL-SC sensor checks A styrofoam box providing optimal insulation and temperature stabilisation of a SAL-SC check during the calibration proceedure. Consisting of two halfcovers for simple temporary mounting. -> Can be used together with the SAL-SC calibration kit for optimal thermal protection during calibration Styrofoam box for the SC check: Dimensions : 100 x 65 x 50 mm : 10 g : thermal insulating styrofoam PPE 252 3134 Spare part plug set HygroMaxx R/S/M Spare parts to HygroMaxx Spare plugs to HygroMaxx R/S/M Spare plug set for HygroMaxx R/S/M PCB, for power supply and analog outputs. Attention: use only 24 VDC +/- 10% power supply! Spare plug set for HygroMaxx: Plug : 2 pole 3.84 mm for power supply 3 pole 3.84 mm for analog outputs : total 20 g 252 3131 room sensor for HygroMaxx S Spare room sensor for HygroMaxx S Spare sensor for HygroMaxx S. The sensor can be replaced by un-tighten the 2 screws in the cover and unplug the RJ 11 connection. Recommendation: switch off the power supply before you replace the sensor Spare sensor for HygroMaxx S : Dimension : 58 x 13 mm Cable : 150mm with RJ 11 : 15 g Housing : stainless steel with membrane protection filter Version : V 4.0. Air-catalogue 2007 page 28 / 28

Spare parts to HygroMaxx Spare duct sensor for HygroMaxx R Spare sensor for HygroMaxx R. The sensor can be replaced by un-tighten the 2 screws in the cover and unplug the RJ 11 connection. Recommendation: switch off the power supply before you replace the sensor Spare sensor for HygroMaxx R : Dimension : 250 x 13 mm Cable : 150mm with RJ 11 : 80 g Housing : stainless steel with membrane protection filter 252 3132 duct sensor for HygroMaxx R probe length 250 mm: 252 3133 SensMaxx 13 with 3m cable Spare remote sensor for HygroMaxx M Spare sensor for HygroMaxx M. This sensor can be replaced including the cable. Recommendation: switch off the power supply before you replace the sensor Spare sensor for HygroMaxx M : Dimension : 150 x 13 mm Cable : 3m 5-pole with shield : 140 g Housing : stainless steel with membrane protection filter Housing lower half for HygroMaxx As spare part for damaged housings. Spare housing bottom for HygroMaxx : Dimension : 110 x118 x 35 mm : 80 g : PVC 252 3135 housing bottom HygroMaxx 252 4210 power supply 24V EUR Options to HygroMaxx R/S/M External power supply 90...260VAC/EUR External primary power supply, for voltage range 90 to 260 VAC with Euro plug system. From the secondary side this power supply can be connected directly to all HygroMaxx types. Technical data: Primary side : Voltage range: 90... 260VAC Euro plug Secondary side : Voltage: 24V DC +/- 5% Cable ends unshielded and ready for connection. : 90 gr 252 4211 power supply 24V US/JP Ext. power supply 90...260VAC / US/JP External primary power supply, for voltage range 90 to 260 VAC with US/Japan plug system. From the secondary side this power supply can be connected directly to all HygroMaxx types.. Technical data: Primary side : Voltage range: 90... 260VAC US/JP plug Secondary side : Voltage: 24V DC +/- 5% Cable ends unshielded and ready for connection. : 110 gr Version : V 4.0. Air-catalogue 2007 page 29 / 29

Options to HygroMaxx 252 4212 Factory calibration HygroMaxx R / S / M Including Novasina factory calibration certificate Factory calibration and certificate for 3 humidity points (11%, 53%, 75% RH) & 1 temperature point (+25 C). -> Enables a higher measurement accuracy of the system Factory calibration certificate : The shipping of new instruments is always including factory calibration certificate, provided that the calibration has been ordered with PN 2524212. See price list calibration Certification of HygroMaxx R / S / M in a accredited European laboratory UKAS certification at min. two humidity points and if required at one or more temperature points. For M versions, the remote sensor has to be sent together with the corresponding transmitter. International certified laboratory Novasina offers the possibility to buy UKAS certified measuring instruments. Version : V 4.0. Air-catalogue 2007 page 30 / 30