> 2033D U P S POWER S U P P L I E S. Dimensions Weights Specifications. UPS Units. CLC Cabinets Dimensions (W x D x H) (inch)

Similar documents
UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

>2033DUPS UNINTERRUPTIBLE P O W E R SUPPLIES

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

TOSHIBA G /100/160/225 kva

PowerGem Pro Uninterruptible Power Supply

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Eaton 93PM UPS Where aesthetics meet intelligence.

>9700UPS UNINTERRUPTIBLE P O W E R SUPPLIES

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Thyristor-controlled power supplies and battery chargers

Phase Modular Finally the benefits of Modular ups are for all

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

MAJORSINE Power Inverter

Frequency Converter Fv

RIELLO ELETTRONICA. Master HP

Power Supply Systems. Performance guaranteed. Power Supply Systems single-voltage UIC-systems multi-voltage UIC-systems

SNMP Web Management. User s Manual For SNMP Web Card/Box

PRODUCT LIST Facility DDC Access WebXL DDC

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

ABB PSPS Erich Steinmann; Generator control-2013

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

32VFD Variable Frequency Drives for Centrifugal Chillers

TRAMS TROLLEY-BUSES SUBWAY

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

Liebert NXL Power-Tie Controls

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Uninterruptible Power Supply

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

NC-12 Modbus Application

Specification CyberWave UPS Ver /01/00

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

Communication and connectivity the ideal solution for integrated system management and data integrity

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Model #: SMART2200CRMXL

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Specifying a Variable Frequency Drive s

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ABB central inverters PVS to 1000 kw

SG Series UPS kva three phase 400 Vac

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

LAP ENERGIA PARA DATACENTERS

Online UPS. PowerWalker VFI 1000R/1U

Single Phase, (3 to 20KVA) & (3 to 15 KW) Harsh Environment Outdoor Application NEMA 3R Cabinet

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

Diesel Generating Set

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

UPS UNINTERRUPTIBLE POWER SUPPLY GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

Power Meter Series 700

User Manual 1K/2K/3K Online UPS

DCS Series 1 kw, 1.2 kw, & 3 kw

Protect. UPS Solutions for large Data centers

USER MANUAL Online UPS 1K/2K/3K

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Digital and Analog I/O

Network Management Card. User Manual

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

LT-82 Stationary IR Transmitter

WVC300 Micro-inverter solar grid system (Power line communications)

Smart-UPS On-Line 230 V

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

MINIMAT-EC-Servo Screwdriver Spindles

Galaxy VM. Three-phase power protection. schneider-electric.com

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

PowerCommand iwatch 100 Remote Network Monitoring

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

4.0 UPS dedicated to ICT for unmatched energy savings

Transcription:

2033D JAN_2011_REVISED_77147_Output 2/1/11 12:35 PM Page 1 Dimensions Weights Specifications UPS Units kva / kw / 24 / 40 / 64 Dimensions 4V / 4V Dimensions (W x D x H) (in) 2,0 1,5 1,9 2,0 1,5 1,9 > 2033D U P S 1. kva weight includes internal batteries (5 lbs.) 2. kva battery back-up, 6 minutes. CLC Cabinets Part Number System CLC-MMS1-0-4 4V / 4V Dimensions CLC-MMS3-0-208 760 CLC-MMS1-0-4 4V / 4V CLC-MMS3-0-208 910 CLC-MMS1-0-4 4V / 4V CLC-MMS3-0-208 42 x 29.5 x 71 1,270 kva UNINTERRUPTIBLE POWER S U P P L I E S Rated Output kva Rated Output kw 24 40 AC INPUT Reflected Current THD 4 V +15% to -15% (-% can be operated) (45.4Hz to 65Hz) 4% typ. at 100% load; 7% typ. at % load STATIC BYPASS INPUT 4 V ±10% BATTERY Type Ride Through Nominal Minimum Number of Cells AC OUTPUT Stability Stability Power Factor Power Factor range THD Transient Response Transient Recovery Inverter Overload System Overload Bypass Overload ENVIRONMENTAL Cooling Operating Temperature Relative Humidity Altitude 64 Lead Acid Application specific 4 VDC 401 VDC 240 3 phase, 4 wire 120 / 208V, 277/ 4V ±1% ±0.05% in free running mode 0.8 nominal 0.8 1.0 lagging (within output kw rating) 2% typical THD at 100% Linear Load; 5% typical THD at 100% non-linear load ±3% at 100% load step; ±1% at loss / return of AC power; ±3% at load transfer to/ from static bypass 16.6 ms 125% for 10 minutes, 1% for 1 minute 1000% for 1 cycle (with bypass available) 1% for 1 minute The quality management system of Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000. The quality management system is applicable to design, development and manufacturing of the UPS. Mitsubishi Electric Power Products, Inc. Uninterruptible Power Supplies (UPS) Division 547 Keystone Drive Warrendale, PA 186 Phone: 724-772-2555 Fax: 724-778-3146 www.meppi.com MK00004R-Rev #2 February 2011 Forced air 32 F ~ 104 F (0 C - 40 C); Recommended 68 F - 86 F (20 C - C) 5% ~ 95% non-condensing 0 ~ 9000 feet no derating Consult Mitsubishi for Battery Cabinet s. GS-07F-9526G Official Sponsor 2033D Specifications: 2033D Series kva kva UPS Dimensions and weights are subject to change without notice. Consult MEPPI for exact dimensions and weights. 1. Consult MEPPI UPS Engineering Department for special CLC cabinet configurations.

2033D JAN_2011_REVISED_77147_Output 2/1/11 12:36 PM Page 2 Mitsubishi The Leader in UPS Technology, quality & Reliability 2033D ONE-LINE DIAgRAMS Superior Performance, Reliability and Safety Come from Experience. Our Uninterruptible Power Supply Systems Ensure All Three. Mitsubishi Electric has been developing and manufacturing Uninterruptible Power Supply (UPS) components and systems for more than three decades. That experience, and the continuous application of new power-device technologies to further improve products in the industry clearly explain why Mitsubishi Electric has dominated a large portion of the world UPS market for years. When purchasing a UPS system, the key word is dependability. And there s one company that many rely on. Uninterruptible Power Supply systems by Mitsubishi Electric. SMS Single Module System Bypass Input UPS Input 3 ø 4W, 208 or 4V, 60Hz 1. External Maintenance Bypass System (MBS) is optional. 2. Batteries included in kva only. 3. K-13 isolation stepdown transformer (208V output) MMS Multi-Module System (4V in/4v out) CLC* CABINET Maintenance Bypass Input 3 ø 3W or 4W, 4V, 60Hz 3 ø 4W, 4V, 60Hz 1. Maximum 2x System for redundancy only 2. CLC* (Critical Load Cabinet includes Maintenance Bypass) 3. All CLC Cabinets engineered and supplied by MEPPI 4. For 208V output consult MEPPI U P S M O N I T O R I N g E q U I P M E N T & S O F T WA R E The Netcom2 hardware SNMP/ Web adapter runs an embedded Simple Network Management Protocol (SNMP) software agent. This powerful and intelligent unit is designed for the rigorous task of managing the UPS systems that protect equipment and the critical data residing throughout the network. IgBT Transistors with Excellent Performance Characteristics Mitsubishi Electric is the leading manufacturer of Insulated Gate Bipolar Transistors (IGBTs), and now utilizes IGBT in the converters and inverters of its 2033D Series UPS systems. These advanced, high-performance transistors provide a variety of intelligent features. High Ampacity Transistors (600A) High Speed Switching Low Control Power Low Input Current Harmonics (THD) 4% typical (100% load) 5% typical (75% load) 7% typical (% load) (No additional filtering required) generator Sizing Ratio (UPS) 1:1 (UPS kva / Generator kw) Low Heat Loss / High Efficiency Use of IGBT enables efficient high-speed switching thus reducing heat dissipation in the UPS. (Higher efficiency means lower cost per kilowatt to the customer.) Log Menu The Netcom2 works with all major NMS systems on Ethernet Netcom2 works with the most widely used Network Management Systems: HP OpenView, Novell ManageWise, Sun NetManager, IBM NetView, and many more. Extended Battery Life Netcom2 Features: Remote UPS status monitoring Monitor a remote UPS system using an RS-232 Cable to the Netcom2 for one UPS system to a remote workstation (NMS) through an Ethernet connection Web Card Assign an IP address to your UPS system to monitor the UPS system from anywhere around the world SNMP Adapter Turn the UPS system s protocol into an SNMP software agent and enable SNMP traps SNMP Viewer Unique Mitsubishi design that color coordinates SNMP messages that inform the NMS about all current UPS alarms Send Shutdown Signal to Networked Servers Send a shutdown signal to servers connected via the Ethernet network Battery and Service Monitoring Monitor the battery life and servicing details of the UPS E-mail Send the Administrator an e-mail when an event occurs Internal Maintenance Bypass All 2033D Series UPS systems are equipped with an internal wrap around maintenance bypass system for greater maintenance flexibility. UL 1778 approved Superior Control Additional Features: Password lock out for start / stop operation EPO button Real-Time Battery Monitoring Remaining battery time displayed for operator Integrated DiamondSense system automatically detects weak cells Superior Functions Automatic restart Automatic retransfer Converter walk-in function Battery monitoring 1-set Form A & B dry contacts of selectable items Large overload / overcurrent capacity Battery temperature compensation Adjustable DC cut-off Line drop compensation All 2033D Series UPS systems use pulse width modulation (PWM) for superior control and performance. A digital signal processor (DSP) ensures precise control of all input / output parameters. quiet Operation Operator-Friendly Control Panel Standard warranty is two years, including parts and labor. Features: ModBus Communications for Building Management Systems The MUCM card allows the customer to integrate Mitsubishi Electric UPS systems into their current Building Management Solution. The MUCM is a user-programmable protocol converter, or data concentrator, that is DIN-rail mountable, with 2 serial ports: One RS-232, one RS-485, and over 2,048 internal mailbox registers. Through the ModBus protocol converter, the UPS system s variables can be monitored through various Building Management System vendors software. Current source from batteries for step loads is no longer required with the installation of IGBT in both the converter and the inverter. Previous UPS systems required assistance from batteries when the converter was unable to supply the required current. This cycling of batteries caused shorter life. Mitsubishi Electric IGBT incorporate the latest technologies and provide step load applications (0-100%) without the use of batteries, thus ensuring maximum battery service life (i.e., lower lifetime cost of UPS system). Mimic bus diagram Operator control station Touch panel input LCD Monitor Displays: System metering Menu-driven start-up procedures Menu-driven operating procedures History of events Load true power factor -kva 65dB (A scale, 1m) Warranty (NOTE: All information subject to change without prior notice.)

2033D JAN_2011_REVISED_77147_Output 2/1/11 12:36 PM Page 2 Mitsubishi The Leader in UPS Technology, quality & Reliability 2033D ONE-LINE DIAgRAMS Superior Performance, Reliability and Safety Come from Experience. Our Uninterruptible Power Supply Systems Ensure All Three. Mitsubishi Electric has been developing and manufacturing Uninterruptible Power Supply (UPS) components and systems for more than three decades. That experience, and the continuous application of new power-device technologies to further improve products in the industry clearly explain why Mitsubishi Electric has dominated a large portion of the world UPS market for years. When purchasing a UPS system, the key word is dependability. And there s one company that many rely on. Uninterruptible Power Supply systems by Mitsubishi Electric. SMS Single Module System Bypass Input UPS Input 3 ø 4W, 208 or 4V, 60Hz 1. External Maintenance Bypass System (MBS) is optional. 2. Batteries included in kva only. 3. K-13 isolation stepdown transformer (208V output) MMS Multi-Module System (4V in/4v out) CLC* CABINET Maintenance Bypass Input 3 ø 3W or 4W, 4V, 60Hz 3 ø 4W, 4V, 60Hz 1. Maximum 2x System for redundancy only 2. CLC* (Critical Load Cabinet includes Maintenance Bypass) 3. All CLC Cabinets engineered and supplied by MEPPI 4. For 208V output consult MEPPI U P S M O N I T O R I N g E q U I P M E N T & S O F T WA R E The Netcom2 hardware SNMP/ Web adapter runs an embedded Simple Network Management Protocol (SNMP) software agent. This powerful and intelligent unit is designed for the rigorous task of managing the UPS systems that protect equipment and the critical data residing throughout the network. IgBT Transistors with Excellent Performance Characteristics Mitsubishi Electric is the leading manufacturer of Insulated Gate Bipolar Transistors (IGBTs), and now utilizes IGBT in the converters and inverters of its 2033D Series UPS systems. These advanced, high-performance transistors provide a variety of intelligent features. High Ampacity Transistors (600A) High Speed Switching Low Control Power Low Input Current Harmonics (THD) 4% typical (100% load) 5% typical (75% load) 7% typical (% load) (No additional filtering required) generator Sizing Ratio (UPS) 1:1 (UPS kva / Generator kw) Low Heat Loss / High Efficiency Use of IGBT enables efficient high-speed switching thus reducing heat dissipation in the UPS. (Higher efficiency means lower cost per kilowatt to the customer.) Log Menu The Netcom2 works with all major NMS systems on Ethernet Netcom2 works with the most widely used Network Management Systems: HP OpenView, Novell ManageWise, Sun NetManager, IBM NetView, and many more. Extended Battery Life Netcom2 Features: Remote UPS status monitoring Monitor a remote UPS system using an RS-232 Cable to the Netcom2 for one UPS system to a remote workstation (NMS) through an Ethernet connection Web Card Assign an IP address to your UPS system to monitor the UPS system from anywhere around the world SNMP Adapter Turn the UPS system s protocol into an SNMP software agent and enable SNMP traps SNMP Viewer Unique Mitsubishi design that color coordinates SNMP messages that inform the NMS about all current UPS alarms Send Shutdown Signal to Networked Servers Send a shutdown signal to servers connected via the Ethernet network Battery and Service Monitoring Monitor the battery life and servicing details of the UPS E-mail Send the Administrator an e-mail when an event occurs Internal Maintenance Bypass All 2033D Series UPS systems are equipped with an internal wrap around maintenance bypass system for greater maintenance flexibility. UL 1778 approved Superior Control Additional Features: Password lock out for start / stop operation EPO button Real-Time Battery Monitoring Remaining battery time displayed for operator Integrated DiamondSense system automatically detects weak cells Superior Functions Automatic restart Automatic retransfer Converter walk-in function Battery monitoring 1-set Form A & B dry contacts of selectable items Large overload / overcurrent capacity Battery temperature compensation Adjustable DC cut-off Line drop compensation All 2033D Series UPS systems use pulse width modulation (PWM) for superior control and performance. A digital signal processor (DSP) ensures precise control of all input / output parameters. quiet Operation Operator-Friendly Control Panel Standard warranty is two years, including parts and labor. Features: ModBus Communications for Building Management Systems The MUCM card allows the customer to integrate Mitsubishi Electric UPS systems into their current Building Management Solution. The MUCM is a user-programmable protocol converter, or data concentrator, that is DIN-rail mountable, with 2 serial ports: One RS-232, one RS-485, and over 2,048 internal mailbox registers. Through the ModBus protocol converter, the UPS system s variables can be monitored through various Building Management System vendors software. Current source from batteries for step loads is no longer required with the installation of IGBT in both the converter and the inverter. Previous UPS systems required assistance from batteries when the converter was unable to supply the required current. This cycling of batteries caused shorter life. Mitsubishi Electric IGBT incorporate the latest technologies and provide step load applications (0-100%) without the use of batteries, thus ensuring maximum battery service life (i.e., lower lifetime cost of UPS system). Mimic bus diagram Operator control station Touch panel input LCD Monitor Displays: System metering Menu-driven start-up procedures Menu-driven operating procedures History of events Load true power factor -kva 65dB (A scale, 1m) Warranty (NOTE: All information subject to change without prior notice.)

2033D JAN_2011_REVISED_77147_Output 2/1/11 12:36 PM Page 2 Mitsubishi The Leader in UPS Technology, quality & Reliability 2033D ONE-LINE DIAgRAMS Superior Performance, Reliability and Safety Come from Experience. Our Uninterruptible Power Supply Systems Ensure All Three. Mitsubishi Electric has been developing and manufacturing Uninterruptible Power Supply (UPS) components and systems for more than three decades. That experience, and the continuous application of new power-device technologies to further improve products in the industry clearly explain why Mitsubishi Electric has dominated a large portion of the world UPS market for years. When purchasing a UPS system, the key word is dependability. And there s one company that many rely on. Uninterruptible Power Supply systems by Mitsubishi Electric. SMS Single Module System Bypass Input UPS Input 3 ø 4W, 208 or 4V, 60Hz 1. External Maintenance Bypass System (MBS) is optional. 2. Batteries included in kva only. 3. K-13 isolation stepdown transformer (208V output) MMS Multi-Module System (4V in/4v out) CLC* CABINET Maintenance Bypass Input 3 ø 3W or 4W, 4V, 60Hz 3 ø 4W, 4V, 60Hz 1. Maximum 2x System for redundancy only 2. CLC* (Critical Load Cabinet includes Maintenance Bypass) 3. All CLC Cabinets engineered and supplied by MEPPI 4. For 208V output consult MEPPI U P S M O N I T O R I N g E q U I P M E N T & S O F T WA R E The Netcom2 hardware SNMP/ Web adapter runs an embedded Simple Network Management Protocol (SNMP) software agent. This powerful and intelligent unit is designed for the rigorous task of managing the UPS systems that protect equipment and the critical data residing throughout the network. IgBT Transistors with Excellent Performance Characteristics Mitsubishi Electric is the leading manufacturer of Insulated Gate Bipolar Transistors (IGBTs), and now utilizes IGBT in the converters and inverters of its 2033D Series UPS systems. These advanced, high-performance transistors provide a variety of intelligent features. High Ampacity Transistors (600A) High Speed Switching Low Control Power Low Input Current Harmonics (THD) 4% typical (100% load) 5% typical (75% load) 7% typical (% load) (No additional filtering required) generator Sizing Ratio (UPS) 1:1 (UPS kva / Generator kw) Low Heat Loss / High Efficiency Use of IGBT enables efficient high-speed switching thus reducing heat dissipation in the UPS. (Higher efficiency means lower cost per kilowatt to the customer.) Log Menu The Netcom2 works with all major NMS systems on Ethernet Netcom2 works with the most widely used Network Management Systems: HP OpenView, Novell ManageWise, Sun NetManager, IBM NetView, and many more. Extended Battery Life Netcom2 Features: Remote UPS status monitoring Monitor a remote UPS system using an RS-232 Cable to the Netcom2 for one UPS system to a remote workstation (NMS) through an Ethernet connection Web Card Assign an IP address to your UPS system to monitor the UPS system from anywhere around the world SNMP Adapter Turn the UPS system s protocol into an SNMP software agent and enable SNMP traps SNMP Viewer Unique Mitsubishi design that color coordinates SNMP messages that inform the NMS about all current UPS alarms Send Shutdown Signal to Networked Servers Send a shutdown signal to servers connected via the Ethernet network Battery and Service Monitoring Monitor the battery life and servicing details of the UPS E-mail Send the Administrator an e-mail when an event occurs Internal Maintenance Bypass All 2033D Series UPS systems are equipped with an internal wrap around maintenance bypass system for greater maintenance flexibility. UL 1778 approved Superior Control Additional Features: Password lock out for start / stop operation EPO button Real-Time Battery Monitoring Remaining battery time displayed for operator Integrated DiamondSense system automatically detects weak cells Superior Functions Automatic restart Automatic retransfer Converter walk-in function Battery monitoring 1-set Form A & B dry contacts of selectable items Large overload / overcurrent capacity Battery temperature compensation Adjustable DC cut-off Line drop compensation All 2033D Series UPS systems use pulse width modulation (PWM) for superior control and performance. A digital signal processor (DSP) ensures precise control of all input / output parameters. quiet Operation Operator-Friendly Control Panel Standard warranty is two years, including parts and labor. Features: ModBus Communications for Building Management Systems The MUCM card allows the customer to integrate Mitsubishi Electric UPS systems into their current Building Management Solution. The MUCM is a user-programmable protocol converter, or data concentrator, that is DIN-rail mountable, with 2 serial ports: One RS-232, one RS-485, and over 2,048 internal mailbox registers. Through the ModBus protocol converter, the UPS system s variables can be monitored through various Building Management System vendors software. Current source from batteries for step loads is no longer required with the installation of IGBT in both the converter and the inverter. Previous UPS systems required assistance from batteries when the converter was unable to supply the required current. This cycling of batteries caused shorter life. Mitsubishi Electric IGBT incorporate the latest technologies and provide step load applications (0-100%) without the use of batteries, thus ensuring maximum battery service life (i.e., lower lifetime cost of UPS system). Mimic bus diagram Operator control station Touch panel input LCD Monitor Displays: System metering Menu-driven start-up procedures Menu-driven operating procedures History of events Load true power factor -kva 65dB (A scale, 1m) Warranty (NOTE: All information subject to change without prior notice.)

2033D JAN_2011_REVISED_77147_Output 2/1/11 12:35 PM Page 1 Dimensions Weights Specifications UPS Units kva / kw / 24 / 40 / 64 Dimensions 4V / 4V Dimensions (W x D x H) (in) 2,0 1,5 1,9 2,0 1,5 1,9 > 2033D U P S 1. kva weight includes internal batteries (5 lbs.) 2. kva battery back-up, 6 minutes. CLC Cabinets Part Number System CLC-MMS1-0-4 4V / 4V Dimensions CLC-MMS3-0-208 760 CLC-MMS1-0-4 4V / 4V CLC-MMS3-0-208 910 CLC-MMS1-0-4 4V / 4V CLC-MMS3-0-208 42 x 29.5 x 71 1,270 kva UNINTERRUPTIBLE POWER S U P P L I E S Rated Output kva Rated Output kw 24 40 AC INPUT Reflected Current THD 4 V +15% to -15% (-% can be operated) (45.4Hz to 65Hz) 4% typ. at 100% load; 7% typ. at % load STATIC BYPASS INPUT 4 V ±10% BATTERY Type Ride Through Nominal Minimum Number of Cells AC OUTPUT Stability Stability Power Factor Power Factor range THD Transient Response Transient Recovery Inverter Overload System Overload Bypass Overload ENVIRONMENTAL Cooling Operating Temperature Relative Humidity Altitude 64 Lead Acid Application specific 4 VDC 401 VDC 240 3 phase, 4 wire 120 / 208V, 277/ 4V ±1% ±0.05% in free running mode 0.8 nominal 0.8 1.0 lagging (within output kw rating) 2% typical THD at 100% Linear Load; 5% typical THD at 100% non-linear load ±3% at 100% load step; ±1% at loss / return of AC power; ±3% at load transfer to/ from static bypass 16.6 ms 125% for 10 minutes, 1% for 1 minute 1000% for 1 cycle (with bypass available) 1% for 1 minute The quality management system of Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000. The quality management system is applicable to design, development and manufacturing of the UPS. Mitsubishi Electric Power Products, Inc. Uninterruptible Power Supplies (UPS) Division 547 Keystone Drive Warrendale, PA 186 Phone: 724-772-2555 Fax: 724-778-3146 www.meppi.com MK00004R-Rev #2 February 2011 Forced air 32 F ~ 104 F (0 C - 40 C); Recommended 68 F - 86 F (20 C - C) 5% ~ 95% non-condensing 0 ~ 9000 feet no derating Consult Mitsubishi for Battery Cabinet s. GS-07F-9526G Official Sponsor 2033D Specifications: 2033D Series kva kva UPS Dimensions and weights are subject to change without notice. Consult MEPPI for exact dimensions and weights. 1. Consult MEPPI UPS Engineering Department for special CLC cabinet configurations.

2033D JAN_2011_REVISED_77147_Output 2/1/11 12:35 PM Page 1 Dimensions Weights Specifications UPS Units kva / kw / 24 / 40 / 64 Dimensions 4V / 4V Dimensions (W x D x H) (in) 2,0 1,5 1,9 2,0 1,5 1,9 > 2033D U P S 1. kva weight includes internal batteries (5 lbs.) 2. kva battery back-up, 6 minutes. CLC Cabinets Part Number System CLC-MMS1-0-4 4V / 4V Dimensions CLC-MMS3-0-208 760 CLC-MMS1-0-4 4V / 4V CLC-MMS3-0-208 910 CLC-MMS1-0-4 4V / 4V CLC-MMS3-0-208 42 x 29.5 x 71 1,270 kva UNINTERRUPTIBLE POWER S U P P L I E S Rated Output kva Rated Output kw 24 40 AC INPUT Reflected Current THD 4 V +15% to -15% (-% can be operated) (45.4Hz to 65Hz) 4% typ. at 100% load; 7% typ. at % load STATIC BYPASS INPUT 4 V ±10% BATTERY Type Ride Through Nominal Minimum Number of Cells AC OUTPUT Stability Stability Power Factor Power Factor range THD Transient Response Transient Recovery Inverter Overload System Overload Bypass Overload ENVIRONMENTAL Cooling Operating Temperature Relative Humidity Altitude 64 Lead Acid Application specific 4 VDC 401 VDC 240 3 phase, 4 wire 120 / 208V, 277/ 4V ±1% ±0.05% in free running mode 0.8 nominal 0.8 1.0 lagging (within output kw rating) 2% typical THD at 100% Linear Load; 5% typical THD at 100% non-linear load ±3% at 100% load step; ±1% at loss / return of AC power; ±3% at load transfer to/ from static bypass 16.6 ms 125% for 10 minutes, 1% for 1 minute 1000% for 1 cycle (with bypass available) 1% for 1 minute The quality management system of Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000. The quality management system is applicable to design, development and manufacturing of the UPS. Mitsubishi Electric Power Products, Inc. Uninterruptible Power Supplies (UPS) Division 547 Keystone Drive Warrendale, PA 186 Phone: 724-772-2555 Fax: 724-778-3146 www.meppi.com MK00004R-Rev #2 February 2011 Forced air 32 F ~ 104 F (0 C - 40 C); Recommended 68 F - 86 F (20 C - C) 5% ~ 95% non-condensing 0 ~ 9000 feet no derating Consult Mitsubishi for Battery Cabinet s. GS-07F-9526G Official Sponsor 2033D Specifications: 2033D Series kva kva UPS Dimensions and weights are subject to change without notice. Consult MEPPI for exact dimensions and weights. 1. Consult MEPPI UPS Engineering Department for special CLC cabinet configurations.