Troubleshooting Guide: 355 Lights (12V)

Similar documents
758 Heavy-duty Ratchet Guy Wire Cutter

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

1000-LB. TRAILER JACK OWNER S MANUAL

CortezTM A Kichler Décor Ceiling Fan

Operating Instructions

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

TABLE OF CONTENTS. I. TROUBLESHOOTING Section 1.01: Common Problems/Solutions... 2

OWNER S MANUAL Table Tennis Table Patent Pending

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Ceiling Fan Installation Instructions

MICROMETER ADJUSTABLE CLICK TYPE TORQUE WRENCH REPAIR, MAINTENANCE AND TROUBLESHOOTING MANUAL

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Operating Instructions

Operator Manual 100 Series Coffee Grinders

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

60" TulleTM. Instruction Manual. A Kichler Select ceiling fan

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

15GAL STEEL OIL DRAIN WITH 110V PUMP

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

12. REAR WHEEL/BRAKE/SUSPENSION

13. REAR WHEEL/BRAKE/SUSPENSION

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Safety, Operation and Maintenance Manual with Parts List

KEYPAD LOCK RETROFIT KIT

Drive shaft, servicing

Front brakes (FN- 3), servicing

PRODUCT MANUAL - M090

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

AXLE SHAFTS - FRONT Pontiac Bonneville MODEL IDENTIFICATION DESCRIPTION & OPERATION TROUBLE SHOOTING REMOVAL & INSTALLATION

HYDRAULIC LIFT TABLE CART 2200-LB.

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

INSTALLATION & OPERATING INSTRUCTIONS

STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Scottsdale 52 in Ceiling Fan Owne r s manual. Scottsdale Ventilador de Techo de 1,32 Manual del Propietario

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

Round Housing with Side Ports

NO LONGER IN. Some service parts may not be available for this product!

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

Easy Tool Retracting System CMC-SR2159ER36

National- Spencer Inc.

Bulb Replacement REPLACING BULBS WARNING

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Rebuild Instructions for and Transmission

MAINTENANCE & TROUBLESHOOTING

Model 2300DR Installation Guide

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Post Mount Light Installation*

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

#12 Professional Meat Grinders

Quickie Rhapsody Service Manual

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

767 Diagnostic System

CHROME FRONT BRAKE MASTER CYLINDER KIT

TS93 EMR T/PT/TDE. Surface applied door closer

TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N

CETAC Z-Drive Assembly

MAINTENANCE & TROUBLESHOOTING

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

DO NOT attempt to repair hub and wheel bearing assembly.

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

Operating Instructions Bedienungsanleitung Mode d emploi

AMERBRITE UNDERWATER WHITE LED POOL LAMP

The Storm 20-Gallon Wet/Dry Vac

Installation Instructions S

MP-4V Heavy Duty Riveter / 39048

2740 Whitten Rd Bldg 103 Memphis, TN Telephone

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Instructions and precautions. Fork Height. Visit our website at:

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

Electric Meat Grinder

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

BOBBIN WINDER - TYPES & FUNCTION

INSTALLATION INSTRUCTIONS

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

Manual for GlobePharma Mini-Press II Rotary Tablet Press

UPPER TENSION MECHANISM - (66 & 99 models)

Tri-Homo Style Operation and Maintenance Instructions

Triac Printed Circuit Board Replacement

LUCCI AIRFUSION QUEST II CEILING FAN

Spreader Light Bulb Replacement Instructions

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Cable Drum Installation

Service Manual Rol-Lift

SMD Rework Station TABLE OF CONTENTS

3. Loosen 3 x grub screws in the Dec end cap and unscrew the cap and counterweight shaft. NEQ6 Belt Modification Kit.

Front axle components, overview

Transcription:

Troubleshooting Guide: 355 Lights (12V) Contents Description Refer To: Troubleshooting - Troubleshooting Chart Adjustments / Repair Procedures Bulb Replacing the Bulb Fuse(s) Replacing the Fuse (Ceiling) Replacing the Fuse (Mobile 120V) Replacing the Fuses (Mobile 230V) Lamp Tube Lamp Tube Brake Adjustment Lamp Tube Pivot Stop Replacement Cross Tube Cross Tube Counterbalance Adjustment Cross Tube Removal / Installation Down Tube Down Tube Removal / Installation Lighthead Lighthead Brake Adjustment Lighthead Removal / Pivot Bearing Replacement Ball Pivot Bearing Ball Pivot Adjustment Ball Pivot Repair Ball Pivot Stop Replacement Main Pivot Stop Main Pivot Stop Replacement Faceplate / IR Filter Cleaning the Faceplate / IR Filter English-1 004-1016-00 [Revised: mo/dd/yr]

Troubleshooting Chart Problem Symptom Probable Cause Check Solution Light will not illuminate. Arm assemblies or lighthead does not rotate freely, or drifts when released. Light does not illuminate. ON / STANDBY switch is ON. Lighthead will not illuminate, or flashed intermittently when lighthead or arm assemblies are moved. Cross tube rotates (at ball pivot joint) too stifly, or drifts when released. Lamp tube does not rotate freely (at cross tube), or drifts when released. Bulb is burned out. Inspect bulb. Replace bulb. Facility circuit breaker is tripped. Check facility circuit breaker. Reset circuit breaker. Line fues(s) blown. Inspect fuses. Replace fuse(s). Ceiling Mtd Lights Mobile Lights: (120V) (230V) Fuse holder malfunctioning. Perform continuity check on fuse holder. Replace fuse holder. Bulb socket is corroded resulting in bad connection. Inspect / clean bulb socket. Replace bulb socket. ON / STANDBY switch malfunctioning. Perform continuity check on switch. Replace ON / STANDBY switch. Transformer malfunctioning. Damaged / disconected wiring in the arm assemblies. 220V Mobile Lights only: AC inlet is malfunctioning. Damaged / disconected wiring in the arm assemblies. Cross tube counterbalance out of adjustment. Ball pivot joint tension out of adjustment. Lamp tube brake tension out of adjustment. With the ON / STANDBY switch ON, check for 12.27 (+0.37) VAC across output leads of transformer. Perform continuity check on wiring from transformer to lighthead. Perform continuity check on AC inlet. Perform continuity check on wiring from transformer to lighthead. Release tension from ball pivot joint and observe to see if the cross tube counterbalances corrrectly. Check for looseness / stiffness in joint. Check for looseness / stiffness in joint. If 12.27 (+0.37) VAC is not present, Replace transformer. Repair / replace any damaged or disconnected wiring. (355 models: Wiring Diagrams) (354 / 355 Combo models: Wiring Diagrams) Replace AC inlet. Repair / replace any damaged or disconnected wiring. (355 models: Wiring Diagrams) (354 / 355 Combo models: Wiring Diagrams) Cross tube counterbalance adjustment. then perform, Ball pivot joint tension adjustment. Lamp tube brake adjustment. Lighthead does not rotate freely (at lamp tube), or drifts when released. Lighthead brake tension out of adjustment. Check for looseness / stiffness in joint. Lighthead brake adjustment. Ceiling Mtd Lights only: Down tube does not rotate, or drifts when released. Improper installation of ceiling plate. (Plate deflecting too much, or not level) Inspect ceiling plate. Check for level & excessive flexing. If ceiling plate is not level, readjust as necessary. If there is excessive flexing, support ceiling structure as necessary. (Refer to installation guide) English-2 004-1016-00 [Revised: mo/dd/yr]

Troubleshooting Chart - continued Problem Symptom Probable Cause Check Solution Arm assemblies can be rotated farther than specified. Lighthead will not operate properly. Mobile Lights only: Brake caster(s) will not lock. Cross tube can be rotated more than 580 in one direction. Lamp tube can be rotated more than 540 in one direction. Lighthead can be rotated more than 180 in one direction. Ceiling Mtd Lights only: Down tube can be rotated more than 580 in one direction. Lighthead assembly illuminates, but not at the proper intensity. Base moves when caster brakes are set. Ball pivot stop is broken. Inspect ball pivot stop. Replace ball pivot stop. Lamp tube pivot stop is broken. Inspect lamp tube pivot stop. Replace lamp tube pivot stop. Lighthead pivot bearing stop is broken. Inspect lighthead pivot bearing. Replace lighthead pivot bearing. Main pivot stop is broken. Inspect pivot stop. Replace main pivot stop. Bulb malfunctioning. - Replace bulb. Wrong input tap is being used on transformer, or facility voltage has changed since installation. Transformer malfunctioning Bulb socket corroded resulting in bad connection, or high resistance. Check facility input voltage & transformer input tap being used. With the ON / STANDBY switch ON, check for 12.27 (+0.37) VAC across output leads of transformer. Inspect / clean bulb socket. Select proper transformer input tap based on facility voltage. If 12.27 (+0.37) VAC is not present, Replace transformer. Replace bulb socket. IR filter is clouded or dirty. Inspect IR filter. Clean IR filter. Faceplate is clouded or dirty. Inspect faceplate. Clean faceplate. Components of lighthead damaged to the point that lighthead is no longer in tolerance. - Return lighthead to Midmark for repair. Call 1-800-MIDMARK, follow the prompts for Technical Service. Caster brakes are worn or malfunctioning Inspect caster brakes. Replace brake caster(s) as necessary. English-3 004-1016-00 [Revised: mo/dd/yr]

Replacing the Bulb warning The maximum bulb wattage for this light is 100 Watts. There is a risk of fire if this limit is exceeded. Use Midmark part number: 002-0640-00. Caution To prevent electrical shock, the light must be in STANDBY mode ( O I ). Allow the light to cool before removing bulb. Move the lighthead away from the exam site to prevent contaminants from falling into the area. Equipment Alert Halogen bulbs are sensitive to body oils. Do not touch the glass portion of the bulb. If the glass portion of the bulb is handled, wipe with a clean soft lint-free cloth. Wipe with alcohol, then pat dry. Bulb To replace bulb.. A) Turn light switch to STANDBY ( O I ). B) Loosen three screws on top of lighthead. (Do not attempt to remove these screws). C) Separate top cap from lighthead housing. D) Pull bulb out of bulb socket, then discard. E) Grasp new bulb with a clean cloth, then insert into bulb socket. F) Align three top cap screws with holes, then tighten screws. Top Cap English-4 004-1016-00 [Revised: mo/dd/yr]

Replacing the Fuses: Ceiling Mounted Lights To replace fuses... A) Turn light switch to STANDBY ( O I ). B) Remove four screws, then lower ceiling cover. C) Using a flat-bladed screwdriver, rotate fuse cap counter-clockwise 1/4 turn, while pushing upward. D) Pull fuse out of fuse cap to inspect. E) Insert fuse into fuse cap. F) Using a flat-bladed screwdriver, rotate fuse cap clockwise 1/4 turn, while pushing into fuse socket. G) Install ceiling cover. Replacing the Fuses: Mobile Lights (120V models) To replace fuses... A) Turn light switch to STANDBY ( O I ). B) Disconnect power cord from light. C) Using a flat-bladed screwdriver, push in on fuse cap and rotate 1/4 turn. D) Remove fuse to inspect. E) Insert new fuse into fuse cap. F) Push fuse / cap into fuse holder and rotate 1/4 turn. NOTE: There are two fuses on this light. After removing the fuse, inspect it to determine whether it is faulty. Fuse Cap CRAFTSMAN MA8474i English-5 004-1016-00 [Revised: mo/dd/yr]

240230220 240230220 Replacing the Fuses: Mobile Lights (230V models) Equipment Alert The voltage setting that appears in the window of the fuse drawer, must match the facility voltage. To adjust the voltage setting, refer to Electrical Input Setting procedure. To replace fuses... A) Turn light switch to STANDBY ( O I ). B) Disconnect power cord from light. C) Using a flat-bladed screwdriver, push in on two locking tabs, then pull fuse drawer out. D) Pull fuses out of fuse drawer to inspect. E) Insert fuses into fuse drawer. F) Insert fuse drawer into AC inlet. (Push in until you hear a clicking sound). G) Connnect power cord. Voltage Window Locking Tabs 230 Voltage Selector Equipment Alert Locking tabs are fragile. Pull gently to prevent damage. Selector Lock Tabs MA8476i To adjust Electrical Input Setting... A) Pull out on two selector lock tabs, then pull voltage selector out of fuse drawer. B) Rotate voltage selector until the correct setting aligns with the voltage window. C) Insert voltage selector into fuse drawer. English-6 004-1016-00 [Revised: mo/dd/yr]

CRAFTSMAN Ball Pivot / Cross Tube Counterbalance Adjustments To release ball pivot tension... A) Slide sleeve up to expose opening. B) Insert screwdriver into adjustment hole. C) Move the screwdriver LEFT until tension is fully released. To adjust cross tube counterbalance... A) Remove cap from counterbalance. B) Loosen / tighten the adjustment screw until the cross tube balances in horizontal position. C) Install cap onto counterbalance. Sleeve Note: Turning the adjustment screw clockwise will raise the lighthead. Turning the adjustment screw counterclockwise will lower the lighthead. Cap Adjustment Hole Adjustment Screw To adjust ball pivot tension... A) Insert screwdriver into adjustment hole. B) Move the screwdriver LEFT / RIGHT to adjust tension setting (LEFT: decreases tension / RIGHT: increases tension) C) Remove screwdriver, and check for desired tension. Repeat until desired tension is achieved. D) Slide sleeve down, then install screw. English-7 004-1016-00 [Revised: mo/dd/yr]

Lamp Tube Brake Adjustment Lighthead Brake Adjustment To adjust lamp tube brake tension... A) Slide pivot sleeve up, then remove two screws. B) Separate lamp tube from cross tube. C) Loosen jam nut. D) Loosen / tighten adjustment nut as necessary. E) Hold adjustment nut in place, then tighten jam nut to 20-30 ft-lbs (27-40.7 N m). F) Reattach lamp tube / cross tube, secure with two screws. G) Check for proper operation. Repeat if necessary. Jam Nut Adjustment Nut Screws securing lamp tube / lighthead must installed properly. Failure to do so may allow lighthead to fall, resulting in injury. To adjust lighthead brake tension... A) Slide pivot sleeve back, then remove two screws. B) Separate lamp tube from lighthead. C) Loosen jam nut. D) Loosen / tighten adjustment nut as necessary. E) Hold adjustment nut in place, then tighten jam nut to 20-30 ft-lbs (27-40.7 N m). F) Reattach lamp tube / lighthead, secure with two screws. G) Check for proper operation. Repeat if necessary. Adjustment Nut Pivot Sleeve Jam Nut Pivot Sleeve English-8 004-1016-00 [Revised: mo/dd/yr]

Lighthead Removal / Pivot Bearing Replacement Disconnect power to the light before performing the following procedure. Failure to comply may result in electric shock. Step 1: Remove lighthead pivot bearing. A) Disconnect power to light. B) Slide pivot sleeve back, then remove two screws. C) Separate lamp tube from lighthead, disconnect two wires. D) Remove two nuts, washers, and pivot bearing. Washers Wave Washer Wave Washers Adjustment Nut Washers Jam Nut Pivot Sleeve Screws securing lamp tube / lighthead must installed properly. Failure to do so may allow lighthead to fall, resulting in injury. Step 2: Install lighthead pivot bearing. A) Install pivot bearing and washers as shown in illustration. B) Install two nuts, but do not tighten at this time. C) Loosen / tighten adjustment nut as necessary. D) Hold adjustment nut in place, then tighten jam nut to 20-30 ft-lbs (27-40.7 N m). E) Connect two wires. F) Reattach lamp tube / lighthead, secure with two screws. G) Check for proper operation. If necessary, separate lighthead, and loosen / tighten adjustment nut. English-9 004-1016-00 [Revised: mo/dd/yr]

Lamp Tube Pivot Stop Replacement Disconnect power to the light before performing the following procedure. Failure to comply may result in electric shock. Step 1: Remove lamp tube pivot stop. A) Disconnect power to light. B) Slide (lamp tube) pivot sleeve back, then remove two screws. C) Separate lamp tube from lighthead, disconnect two wires. D) Slide (cross tube) pivot sleeve back, then remove two screws. E) Separate lamp tube from cross tube. F) Cut two connectors off of wires coming out of the lamp tube. G) Pull two wires out of lamp tube. H) Remove two nuts, washers, pivot bearing, and pivot stop. Lamp Tube Pivot Sleeve Screws securing lamp tube / lighthead must installed properly. Failure to do so may allow lighthead to fall, resulting in injury. Wave Washers Step 2: Install lamp tube pivot stop. A) Install pivot stop, pivot bearing, & washers as shown in illustration. B) Install two nuts, but do not tighten at this time. C) Feed two wires thru lamp tube, then install two connectors. D) Connect two wires from lamp tube to lighthead. E) Reattach lamp tube / lighthead, secure with two screws. F) Loosen / tighten adjustment nut as necessary. G) Hold adjustment nut in place, then tighten jam nut to 20-30 ft-lbs (27-40.7 N m). H) Reattach lamp tube / cross tube, secure with two screws. I) Check for proper operation. If necessary, separate cross tube, and loosen / tighten adjustment nut. Adjustment Nut Jam Nut Lamp Tube Washers Pivot Sleeve English-10 004-1016-00 [Revised: mo/dd/yr]

Cross Tube Removal / Installation Disconnect power to the light before performing the following procedure. Failure to comply may result in electric shock. The cross tube / lighthead is very heavy. To prevent injury, use an assistant for the following procedure. Pivot Sleeve To remove cross tube... A) Disconnect power to light. B) Remove screw, then slide pivot sleeve up. C) While supporting cross tube / lighthead, remove two screws, then separate cross tube from down tube. D) Disconnect two wires and remove cross tube. Screws securing cross tube must be installed properly. Failure to do so may allow lighthead to fall, resulting in injury. To install cross tube... A) Connect wires as shown. (Install new wire connectors if necessary) B) Insert cross tube into down tube. (Do not pinch wires). C) Secure cross tube with two screws. (See NOTE) D) Refer to Ball Pivot Tension Adjustment if necessary. E) Slide pivot sleeve down, secure with screw. NOTE: There are three holes in ball pivot bearing. Two holes are larger with coarser threads. Use these two holes to secure cross tube. The other hole is pivot sleeve screw. English-11 004-1016-00 [Revised: mo/dd/yr]

Down Tube Removal / Installation (Ceiling Lights) Step 1: Remove cross tube / lighthead. Refer to: Cross Tube Removal / Installation. Step 2: Remove down tube. A) Remove four screws and ceiling cover. B) Remove two screws, then separate down tube. C) Pull two wires up thru down tube. Apply removable threadlocking adhesive. (Torque: 40 to 50 in-lbs (4.5 to 5.6 N m) Screws securing down tube must installed properly. Failure to do so may allow lighthead to fall, resulting in injury. To install down tube / ceiling cover... A) Install down tube, then secure with two screws*. Tighten screws to 40 to 50 in-lbs (4.5 to 5.6 N m) (* apply removable threadlocking adhesive to screws) B) Position ceiling cover, then secure with four screws. MA8549i English-12 004-1016-00 [Revised: mo/dd/yr]

Main Pivot Stop Replacement (Ceiling Lights) Step 1: Remove cross tube. Refer to: Cross Tube Removal / Installation. Step 2: Remove down tube. Refer to: Down Tube Removal / Installation. Equipment Alert Strain relief knot must be above the groove pin. Be sure that groove pin is between two wires, and that wires do not get pinched when pin is installed. Step 3: Replace main pivot stop. A) Using a punch, remove groove pin. B) Remove washer, pivot housing, and pivot stop. C) Inspect two stop pins. Replace pin(s) if damaged. D) Install main pivot stop, pivot housing, and washer onto shaft. E) Install groove pin. Stop Pins Step 4: Install down tube. Refer to: Down Tube Removal / Installation. Step 5: Install cross tube / lighthead. Refer to: Cross Tube Removal / Installation. Strain Relief Knot Groove Pin English-13 004-1016-00 [Revised: mo/dd/yr]

Ball Pivot Repair Retaining Ring Step 1: Remove cross tube. Refer to: Cross Tube Removal / Installation. Wave Washers Washer (large) Cam Step 2: Remove ball pivot assembly. A) Insert screwdriver into adjustment hole. B) Move the screwdriver LEFT until tension is fully released. C) Cut wire connectors from two wires. (Preserve as much wire length as possible) D) Using a punch, remove groove pin. Washer (small) Thrust Washer Washer (large) Adjustment Hole Pivot Bearing (install teflon side UP) CRAFTSMAN Step 3: Disassemble the ball pivot. A) Remove retaining ring and washer from ball pivot shaft. B) Using a punch, remove groove pin. (see NOTE) C) Disassemble ball pivot components from shaft / housing. D) Inspect pivot bearing for excessive wear. Replace if necessary. NOTE: Groove pin has serrations on one end. Do not drive serrations thru ball pivot shaft. Step 4: Assemble the ball pivot. A) Install pivot bearing, washers, and cam as shown. B) Install groove pin. C) Install washer, then secure with retaining ring. English-14 004-1016-00 [Revised: mo/dd/yr]

Ball Pivot Stop Replacement Step 1: Disassemble the ball pivot. Refer to: Ball Pivot Repair. Step 2: Replace ball pivot stop. A) Remove two flange bearings. B) Disassemble shaft / housing components. C) Inspect stop pin. Replace if necessary. D) Install pivot stop (with raised portion facing UP), housing, and brake onto shaft. E) Install two flange bearings into shaft. Pivot Stop (raised portion UP) NOTE: Groove pin has serrations on one end. Do not drive serrations thru ball pivot shaft. Step 3: Assemble the ball pivot. Refer to: Ball Pivot Repair. Stop Pin (replace if damaged) English-15 004-1016-00 [Revised: mo/dd/yr]

Cleaning the Faceplate / IR Filter Disconnect power to the light before performing the following procedure. Failure to comply may result in electric shock. To clean the faceplate / IR filter... A) Remove eight screw and the faceplate assembly. B) Do NOT touch the IR filter, the clear faceplate, or the interior surface of the reflector with bare fingers. C) Use a can of compressed air to clean the inside of the lighthead. English-16 004-1016-00 [Revised: mo/dd/yr]