Exercise, the Electrocardiogram, and Peripheral Circulation



Similar documents
Small Animal Respiratory Exchange Ratio (RER)

Experiment HE-6: Breath by Breath Measurement of Respiratory Exchange Ratio (RER)

Data Analysis 1. Click the 2-Cursor icon (Figure HH-7-L1) so that two blue vertical lines appear over the recording window.

iworx Sample Lab Experiment HN-2: Stretch Receptors and Reflexes

Experiment MP-1: Electromyogram (EMG) Activity and Muscle Strength

Biology 347 General Physiology Lab Advanced Cardiac Functions ECG Leads and Einthoven s Triangle

Electrocardiogram and Heart Sounds

Monitoring EKG. Evaluation copy

Activity 4.2.3: EKG. Introduction. Equipment. Procedure

Project 4.2.1: Heart Rate

Lab 3: Introduction to Data Acquisition Cards

Introduction Configuring Your HP Mouse Batteries Replacing the Batteries Mouse Sensor Technology Navigating the HP Mouse Control Center

Electrocardiography I Laboratory

Experiment HE-8: Regulation of Body Temperature and the Respiratory Exchange Ratio (RER)

Laerdal Patient Monitor Help Page 1 June 14, 2012, Rev E

LCD MONITOR TOUCH PANEL DRIVER 2 OPERATION MANUAL. for Mac. Version 1.0 PN-L703A/PN-70TA3/PN-L703B/PN-70TB3/PN-L603A/PN-60TA3/PN-L603B/PN-60TB3

Muscle Physiology. Lab 5. Human Muscle Physiology

1. Installing The Monitoring Software

ADINSTRUMENTS. making science easier. LabChart 7. Student Quick Reference Guide

Manual. Sealer Monitor Software. Version

Heart Rate and Physical Fitness

Evaluation copy. Analyzing the Heart with EKG. Computer

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Capacitive Touch Lab. Renesas Capacitive Touch Lab R8C/36T-A Family

LCD MONITOR TOUCH DISPLAY DRIVER OPERATION MANUAL. for Mac. Version 1.0 PN-K322B/PN-K322BH/LL-S201A. Applicable models

Biopac Student Lab BASIC TUTORIAL. BIOPAC Systems, Inc. Version 3.0.3

Creating a Poster in PowerPoint A. Set Up Your Poster

Getting Started on the Computer With Mouseaerobics! Windows XP

SA-9600 Surface Area Software Manual

PIGCHAMP MOBILE. PigCHAMP Knowledge Software. Installation Guide for Mobile Units

Smart Board Basics. December, Rebecca Clemente Department of Education

HP Advanced Wireless Docking Station. User Guide

Getting to Know Your Mobile Internet Key

Using USB Flash Drives

Appendix C. Vernier Tutorial

2. How to Use SMART Board as a Projector and Whiteboard

Computer Basics: Tackling the mouse, keyboard, and using Windows

TBS Help Index / On Board Software User Manual

Instructions for Installing and Using the FOCUS DL-15 Data Transfer Software

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

BrainMaster tm System Type 2E Module & BMT Software for Windows tm. Helpful Hints

#AS148 - Automated ECG Analysis

How to use a SMART Board

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

Parts List. Navigation

such as USB drives, connected servers, DVDs, CDs, configure file labels, and the information that appears in the Finder window sidebar.

User's Guide DylosLogger Software Version 1.6

Introduction to MS WINDOWS XP

Winlead Dialer Software Users Manual Addendum 3 Installing Winlead Dialer Software on the Windows 2000 System

SMART Board Training Packet. Notebook Software 10.0

MacBook and OS X Basics

DCM555 - Data Communications Lab 8 Time Division Multiplexing (TDM) Part 1 - T1/DS1 Signals

Loss of data can happen in many ways. One of the most common causes is hard drive failure. Hard drives can die without warning.

Biopac Student Lab Lesson 6 ELECTROCARDIOGRAPHY (ECG) II Introduction. Rev

Smart Sync. Computer Classroom Management Software. What is SMART Sync? Table of Contents

user manual IH-W350DB IH-W351DW MyLife webcam pro 5.0 megapixel max resolution

EasyMP Network Projection Operation Guide

Heart Rate and Exercise

Lab 1: Full Adder 0.0

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview

Polar Cardio GX: Help Topics

Interactive Whiteboard Functionality Overview Choosing Pen Style Erasing / Modifying Writing Undo / Redo

EasyMP Multi PC Projection Operation Guide

PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL. Version 2.1

Table of Contents. 0. Internet Connectivity Assumptions Identifying the Network Wall Jack Identifying the Ethernet Cable..

QUIT MACSCHOOL AND DRAG YOUR SERVER ICONS TO THE TRASH OR HIT THE DISCONNECT BUTTON BESIDE THE SERVER ICON IN THE TOP SIDEBAR

The SMART Board Interactive Whiteboard

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

MED-AFEs Design Reference Manual

Contents News Spike2

Human ECG Laboratory Experiment By

USB External Hard Disk Drive

Tutorial How to upgrade firmware on Phison S8 controller MyDigitalSSD using a Windows PE environment

HP LaserJet MFP Analog Fax Accessory 300 Fax Guide

SMART Board 9 Software Tips and Tricks

QUICK START GUIDE Bluetooth Cordless Hand Scanner (CHS)

Operating Systems. and Windows

Audio-Technica AT-LP60-USB, AT-LP120-USB, AT-LP240-USB & AT-LP1240-USB Turntables. Software Guide

Getting the most from your Maxtor OneTouch TM USB hard drive and Linksys Network Storage Link

How To Use An Easymp Network Projection Software On A Projector On A Computer Or Computer

Steps for using MagicConnect

AUDITVIEW USER INSTRUCTIONS

S PT-E550W ELECTRONIC E C LABELING L SYSTEM

How To Use An Easymp Network Projector On A Computer Or Network Projection On A Network Or Network On A Pc Or Mac Or Ipnet On A Laptop Or Ipro Or Ipo On A Powerbook On A Microsoft Computer On A Mini

PA500II Enterprise Mobile Computer

Guide for Remote Control PDA

FSU Inventory Scanner Set up & Use for Windows PC

Global Water Instrumentation, Inc.

User Support Manual KIDS IEP AND DATA MANAGEMENT SOFTWARE PROGRAM. Customized Relational Technology, Inc.

Dash 18X / Dash 18 Data Acquisition Recorder

Connecting External Resources

The EasySense unit can detect that the Smart Q Heart Rate Sensor is connected and the range it is set to.

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

A. FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT

Using These Manuals. How to Use the. Software User Guide. Display examples: 1. Understanding How to Use Your Camera.

Instytut Fizyki Doświadczalnej Wydział Matematyki, Fizyki i Informatyki UNIWERSYTET GDAŃSKI

File Management and File Storage

Transcription:

iworx Physiology Lab Experiment Experiment HH-3 Exercise, the Electrocardiogram, and Peripheral Circulation Note: The lab presented here is intended for evaluation purposes only. iworx users should refer to the User Area on www.iworx.com for the most current versions of labs and LabScribe2 Software. iworx Systems, Inc. www.iworx.com iworx Systems, Inc. 62 Littleworth Road, Dover, New Hampshire 03820 (T) 800-234-1757 / 603-742-2492 (F) 603-742-2455 LabScribe2 is a trademark of iworx Systems, Inc. 2013 iworx Systems, Inc.

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation Background The arterial system functions as a pressure reservoir. Blood enters via the heart and exits through the capillaries. Signals from the autonomic nervous system control the tone of smooth muscle sphincters around the arterioles. In this way, the autonomic nervous system can control the distribution of blood to the various organs in the body. The distribution of blood that flows to a particular organ is influenced by local conditions. If there are cells that require arterial blood, due to a decline in ph or oxygen levels or an increase in carbon dioxide levels, smooth muscle sphincters open to permit blood into particular capillary beds. At rest, the distribution of blood to a particular organ may be very different from that seen during exercise. For example, the blood flow to the gut decreases during exercise, while blood flow to the skeletal muscles increases dramatically. Furthermore, the amount of blood flowing around the circulatory system may be increased several fold. In this laboratory you will record the electrocardiogram and the finger pulse from a (healthy) subject. These parameters will be recorded when the subject is at rest and immediately after exercise. Warning: This experiment involves exercise and an elevation of heart rate. It should not be performed by anyone who is not healthy or has a personal or family history of cardiovascular or respiratory problems. HH-3-1

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation Equipment Required PC or Mac Computer IXTA data acquisition unit USB cable IXTA power supply C-ISO-B3G ECG cable and electrode lead wires PT-104 Pulse plethysmograph FT-220 Hand dynamometer Alcohol swabs Disposable ECG electrodes IXTA Setup 1. Place the IXTA on the bench, close to the computer. 2. Check Figure T-1-1 in the Tutorial Chapter for the location of the USB port and the power socket on the IXTA. 3. Check Figure T-1-2 in the Tutorial Chapter for a picture of the IXTA power supply. 4. Use the USB cable to connect the computer to the USB port on the rear panel of the IXTA. 5. Plug the power supply for the IXTA into the electrical outlet. Insert the plug on the end of the power supply cable into the labeled socket on the rear of the IXTA. Use the power switch to turn on the unit. Confirm that the red power light is on. Start the Software 1. Click on the LabScribe shortcut on the computer s desktop to open the program. If a shortcut is not available, click on the Windows Start menu, move the cursor to All Programs and then to the listing for iworx. Select LabScribe from the iworx submenu. The LabScribe Main window will appear as the program opens. 2. On the Main window, pull down the Settings menu and select Load Group. 3. Locate the folder that contains the settings group, IPLMv4.iwxgrp. Select this group and click Open. 4. Pull down the Settings menu again. Select the Exercise-ECG-Circulation-LS2 settings file from Human Heart. 5. After a short time, LabScribe will appear on the computer screen as configured by the Exercise- ECG-Circulation-LS2 settings. 6. For your information, the settings used to configure the LabScribe software and the IXTA unit HH-3-2

for this experiment are programmed on the Preferences Dialog window which can be viewed by selecting Preferences from the Edit menu on the LabScribe Main window. 7. Once the settings file has been loaded, click the Experiment button on the toolbar to open any of the following documents: Appendix Background Labs Setup (opens automatically) ECG Cable and Pulse Transducer Setup 1. Locate the C-ISO-B3G ECG cable and electrode lead wires (Figure HH-3-S1), and PT-104 pulse plethysmograph (Figure HH-3-S2), in the iworx kit. 2. Plug the DIN8 connector to the PT-104 into the Channel A5 input of the IXTA (Figure HH-3S3). 3. Insert the connector on the end of the C-ISO-B3G ECG cable into the iwire 1 input on the front of the IXTA. 4. Insert the connectors on the red, black, and green electrode lead wires into the matching sockets on the ECG cable. 5. Instruct the subject to remove all jewelry from their wrists and ankles. Another option is to use the area just under each clavicle which will give a better recording. 6. Use an alcohol swab to clean and scrub a region with little or no hair, on the inside of the subject s right wrist/clavicle. Let the area dry. 7. Remove a disposable ECG electrode from its plastic shield, and apply the electrode to the scrubbed area on the wrist/clavicle Figure HH-3-S1: The C-ISO-B3G ECG cable with three lead wires attached. HH-3-3

Figure HH-3-S2: The PT-104 pulse plethysmograph. 8. Repeat Steps 6 and 7 for the inside of the left wrist/clavicle and the inside of the right ankle. 9. Snap the lead wires onto the electrodes, so that: the red (+1) lead is attached to the left wrist or under the left clavicle, the black (-1) lead is connected to the right wrist or under the right clavicle, the green (C or ground) lead is connected to the right leg or on the abdomen. 10. Place the plethysmograph on the volar surface (where the fingerprints are located) of the distal segment of the subject s middle finger or thumb, and wrap the Velcro strap around the end of the finger to attach the unit firmly in place. 11. Instruct the subject to sit quietly with their hands in their lap. If the subject moves, the ECG trace will move off the top or bottom of the screen. If the subject moves any muscles in the arms or upper body, electromyograms (EMGs) from the muscles will appear on the ECG recording as noise. Figure HH-3-S3: The ECG cable and pulse transducer connected to an IXTA. HH-3-4

Experiment HH-3: Exercise, the Electrocardiogram, and Peripheral Circulation Exercise 1: The ECG and the Pulse in a Resting Subject Aim: To measure and correlate the ECG and the pulse in a resting individual. Procedure 1. Click on the Record button, located on the upper right side of the LabScribe Main window (Figure HH-3-L1). The signal should begin scrolling across the screen. Note: If the user clicks the Record button and there is no communication between the iworx unit and computer, an error window will appear in the center of the Main window. Make sure the iworx unit is turned on and connected to the USB port of the computer. Click OK and select the Find Hardware function from the LabScribe Tools menu. 2. Click on the AutoScale button at the upper margin of the ECG, Pulse, and Heart Rate channels. Your recording should look like Figure HH-3-L1. If the signal on either the ECG or the Pulse channel is upside down when compared to trace in Figure HH-3-L1, click on the downward arrow to the left of the channel title and select the Invert function. The trace should now look similar to the one in the figure If a larger ECG signal is required, the electrodes should be moved from the wrists to the skin below each clavicle. If the pulse signal is small or noisy, adjust the tension on the strap holding the pulse plethysmograph to the finger. 3. When you have a suitable trace, type <Subject s Name> Resting ECG/Pulse in the Mark box to the right of the Mark button. Press the Enter key on the keyboard to attach the comment to the data. Record for a minute or two. 4. Click Stop to halt recording. 5. Select Save As in the File menu, type a name for the file. Choose a destination on the computer in which to save the file, like your lab group folder). Designate the file type as *.iwxdata. Click on the Save button to save the data file. HH-3-5

Figure HH-3-L1: ECG, pulse and heart rate displayed on the Main window. The arrow is placed above a dichrotic notch. Exercise 2: The ECG and Pulse After Leg Exercises Aim: To measure and correlate the ECG and the pulse immediately after exercise using the leg muscles. Procedure While the subject is resting, disconnect the C-AAMI-504 cable and the pulse plethysmograph cable from the IWX/214 unit. Coil up the C-AAMI-504 and the PT-104 cables so the subject can hold the cables in his or her hand while exercising with the leg muscles, like walking stairs or gently jogging in place. Remember that the lead wires are still attached to the electrodes, so the free portion of the cables need to be long enough to allow the subject to move easily, yet short enough that the subject does not trip. Instruct the subject to exercise for three minutes. Immediately after the exercise period is over, have the subject sit down and relax next to the recording equipment. Quickly reconnect the C-AAMI-504 and the PT-104 cables to the IWX/214 unit. Click on the Record button. Click AutoScale on all three channels. While recording, type ECG/Pulse-Recovery from Exercise in the Mark box to the right of the Mark button. Press the Enter key on the keyboard to attach the comment to the data. Continue recording until the subject s heart and breathing rates have returned to normal. This may take less than 2 minutes, or longer than 10 minutes, depending on the fitness of the subject. Enter marks and comments on the recording at 30 second intervals by typing comments on the Mark line and clicking on the Mark button or pressing the Enter key on the keyboard. Click Stop to halt recording. Select Save in the File menu on the LabScribe window. HH-3-6

Data Analysis Use the following techniques to analyze the data from Exercises 1 and 2. The information extracted from these exercises will demonstrate the effects of exercise and recovery on heart or pulse rate. 1. Scroll through the recording and find a section of data with four or five exemplary ECG/Pulse cycles recorded in succession while the subject was resting. 2. Use the Display Time icons to adjust the Display Time of the Main window to show at least four complete ECG/Pulse cycles on the Main window. Four adjacent ECG/Pulse cycles can also be selected by: Placing the cursors on either side of a group of four complete ECG/Pulse cycles. Clicking the Zoom between Cursors button on the LabScribe toolbar to expand the segment with the four selected ECG/Pulse cycles to the width of the Main window. 3. Click on the Analysis window icon in the toolbar (Figure HH-3-L2) or select Analysis from the Windows menu to transfer the data displayed in the Main window to the Analysis window (Figure HH-3-L4). Figure HH-3-L2: The LabScribe toolbar. 4. Look at the Function Table that is above the uppermost channel displayed in the Analysis window. The names of the mathematical functions used in the analysis, V2-V1 and T2-T1, appear in this table. The values for V2-V1 and T2-T1 from each channel are seen in the table across the top margin of each channel. 5. Once the cursors are placed in the correct positions for determining the amplitudes and the time intervals on each ECG/Pulse cycle, the values of these amplitudes and time intervals can be recorded in the on-line notebook of LabScribe by typing their names and values directly into the Journal, or on a separate data table. 6. The functions in the channel pull-down menus of the Analysis window can also be used to enter the names and values of the parameters from the recording to the Journal. To use these functions: Place the cursors at the locations used to measure the amplitudes and time intervals of the ECG/Pulse cycle. Transfer the names of the mathematical functions used to determine the amplitudes and time interval to the Journal using the Add Title to Journal function in the ECG Channel pull-down menu. HH-3-7

Transfer the values for the amplitudes and beat period to the Journal using the Add Ch. Data to Journal function in the ECG Channel pull-down menu. 7. Use the mouse to click on and drag the cursors to specific points on the ECG/Pulse recording to measure the following: The R-wave amplitude. To measure the R wave amplitude, place one cursor on the Q wave that precedes the R wave and the second cursor on the peak of the R wave. The value for V2-V1 on the ECG channel is this amplitude. Measure the amplitudes of two additional R waves. The beat period, which is the time interval between two adjacent R waves (Figure HH-3- L3). To measure the beat period, place one cursor on the peak of an R wave and the second cursor on the peak of the adjacent R wave. The value for T2-T1 on the ECG channel is the beat period. Measure the beat period for two additional pairs of R waves. Figure HH-3-L3: An ECG trace recorded in the Main window with labels to indicate the four time values to be measured during data analysis. The P-R interval. To measure this time interval, place one cursor at the beginning of the P wave and the second cursor at the beginning of the QRS complex. The value for T2-T1 on the ECG channel is the P-R interval. Measure this time interval for two additional ECG cycles. The Q-T interval. To measure this time interval, place one cursor at the beginning of the QRS complex and the second cursor at end of the T wave. The value for T2-T1 on the ECG channel is the Q-T interval. Measure this time interval for two additional ECG cycles. The T-P interval. To measure this time interval, place one cursor at the end of the T wave and the second cursor at the beginning of the P wave. The value for T2-T1 on the ECG channel is the T-P interval. Measure this time interval for two additional ECG cycles. HH-3-8

The R-Pulse interval, which is the time interval between the peak of the R wave and the peak of the pulse wave that follows the R wave (Figure HH-3-L3). To measure this interval, place one cursor on the peak of a R wave and the second cursor on the peak of the pulse wave to its right. The value for T2-T1 on any channel is this interval. Measure this interval for two additional ECG/Pulse cycles. The Pulse wave amplitude. To measure the pulse wave amplitude, place one cursor on the baseline that precedes the pulse wave and the second cursor on the peak of the pulse wave (Figure HH-L3). The value for V2-V1 on the Pulse channel is this amplitude. Measure this amplitude for two additional pulse waves. 8. Calculate the following values and type your results into the Journal or on a separate data table: The average R-wave amplitude. The average beat period, in seconds/beat. The heart rate, which is expressed in beats per minute and calculated from the average beat period by using the following equation: Heart Rate (beats/minute) = 60 seconds/minute # seconds/beat Note: Heart Rate can also be determined by looking at the Mean function on the Heart Rate Channel. The more data on screen - the more accurate the Mean heart rate. The average P-R interval. The average Q-T interval. The average T-P interval. The average R-Pulse interval. The average pulse wave amplitude. 9. Scroll through the recording and find a section of data with four or five exemplary ECG/Pulse cycles recorded in succession when the subject just stopped exercising (Recovery time = 0 seconds). Repeat Steps 2 through 7 for this section of data. 10. Move to the sections of data marked at 30 second intervals throughout the recovery period began and repeat the measurements performed in Steps 2 through 7. Questions 1. How does the heart rate from the subject at rest and at 0, 30, 60, 90, and 120 seconds after exercise (recovery) compare? If there is any variation between the rates for each time period? Is there a trend and what is it? HH-3-9

2. How does the average P-R interval from rest and each time period in recovery compare? Do you see any variation or trend? 3. How does the average Q-T interval from rest and each time period in recovery compare? Do you see any variation or trend? 4. How does the average T-P interval from rest and each time period in recovery compare? Do you see any variation or trend? 5. How does the average R-Pulse interval from rest and each time period in recovery compare? Do you see any variation or trend? 6. How does the average R-wave ECG amplitude from rest and each time period in recovery compare? Do you see any variation or trend? 7. How does the average pulse wave amplitude from rest and each time period in recovery compare? Do you see any variation or trend? 8. Is there any affect on the blood flow through subject s finger as the subject is performing leg exercises? Figure HH-3-L4; ECG, pulse, and heart rate displayed in the Analysis window with cursors placed to measure the pulse amplitude with the V2-V1 function. Display has been doubled so that a Mean heart rate can be calculated over a 30 second time frame. Exercise 3: The ECG and Pulse After Hand Exercises Aim: To measure and correlate the ECG and the pulse immediately after exercise. Procedure 1. Instruct the subject to sit quietly with their hands in their lap. 2. Make sure the ECG lead wires are connected to the electrodes, and the pulse plethysmograph is attached to subject s finger properly. HH-3-10

3. Grasp the dynamometer in the palm of the hand with the plethysmograph attached. Note: The FT-325 hand dynamometer is not plugged into the IWX/214 unit at this time. The FT-325 is being used as the resistance against which the hand muscles do some work. 4. Rhythmically squeeze the dynamometer bulb for three minutes or until the forearm muscles fatigue. 5. Immediately after the subject stops squeezing the hand dynamometer, click on the Record button. Click AutoScale on all three channels. While recording, type ECG/Pulse-Recovery from Hand Exercise in the Mark box to the right of the Mark button. Press the Enter key on the keyboard to attach the comment to the data. Record for three minutes or until the amplitude of the finger pulse signal (CH 3) has attained a reasonably constant level for one minute. 6. Click Stop to halt recording. 7. Select Save in the File menu. Data Analysis Use the techniques used in Exercises 1 and 2 to determine: The heart rate from the subject at rest and at 0, 30, 60, 90, and 120 seconds into the recovery period from hand exercise The average R-Pulse interval for rest and each time period of recovery. The average R-wave amplitude for rest and each time period of recovery. The average pulse wave amplitude for rest and each time period of recovery. Questions 1. How do the amplitudes of the pulse waves from the rest and each time period of recovery from hand exercise compare? 2. How do the heart rates for rest and each time period of recovery from hand exercise compare? 3. How do the amplitudes of the pulse waves from the leg and hand exercises compare? Does one type of exercise cause more blood flow in the hand than the other? 4. How do the heart rates from the leg and the hand exercise compare? Does one type of exercise cause a higher heart rate than the other? 5. Do the R-pulse intervals and the R-wave amplitudes from the hand exercise differ from the same values from the leg exercise? HH-3-11