620 Mobile Piston Pump ADY074 ADY098

Similar documents
220 Series Piston Pump Typical Applications Features and Benefits

PVH131/141 Variable Displacement Piston Pump - 11 Design

Dual Path Mobile Pump

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Table of Contents. M Series Variable Displacement Piston Pumps

Vickers PVM Piston Pumps

Series PVP Variable Volume Piston Pumps

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Series TMM Axial Piston Motor. Technical Information

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

Variable Displacement Pump AA10VSO

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Rexroth Hydraulic Pump A10VO Series User Manual

PVM Piston Pumps Service Manual

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

PUMP AND MOTOR DIVISION

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Char-Lynn Disc Valve Motors. Parts Information Compact Series

Vickers. Piston Pumps

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors


HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

Char-Lynn Hydraulic Motors. Repair Information. W Series Geroler Motors 002, 003. April, 1999

Radial piston pumps type R and RG

Vane Pump & Motor Design Guide

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C**

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

HYDRAULIC MOTORS Concentric AB

Fixed displacement vane pumps

H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Vickers Vane Pumps V Series - Low Noise Vane Pumps. High Performance Intravane Pumps For Industrial Applications

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

High Torque Vane Motors MV015, MV037, MV057, MV125

Rickmeier Solutions. Gear pumps for superior Lubrication

Internal gear pump PGF Series 2X and 3X

C18 ACERT Fire Pump Tier bkw/ rpm

Series 40 Axial Piston Motors. Technical Information

Vickers Vane Pump & Motor Design Guide For Mobile Equipment

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

KDG3V-5/7/8, 10 Series

Unit 24: Applications of Pneumatics and Hydraulics

FP12 FERRA SERIES HEAVY DUTY GEAR PUMP

ROTARY GEAR FLOW DIVIDERS

P7100 PUMP INSTALLATION INSTRUCTIONS Diesel Care & Performance Inc

Hydraulic Flow Control Valves

Solenoid Operated Directional Valves


Air Eliminators and Combination Air Eliminators Strainers

Check Valves Valve locator

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

HMC Series Dual Displacement Staffa Motor

Example. Fluid Power. Circuits

Round Housing with Side Ports

PART 2 FORKLIFT HYDRAULIC SYSTEM

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Quiz On Information Learned From Chapter 1

BOWIE PUMPS OPERATION - MAINTENANCE

Signature and ISX CM870 Fuel System

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Energy Recovery Device isave 21-40

Axial Piston Variable Pump A10VSO

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Solenoid Operated Directional Valves

W900 SERIES HYDRAULIC PUMP

Hydraulic Trouble Shooting

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

Axial Piston Fixed Displacement Motor A2FM

CSD WATER REMOVAL FILTERS FOR DIESEL

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

Class 5 to 7 Truck and Bus Hydraulic Brake System

DuraForce HPV Variable Pumps for Closed Loop Operation

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Unit 24: Applications of Pneumatics and Hydraulics

"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type

PRESSURE REDUCING CONTROL VALVE

3516 Industrial Engine

Axial Piston Variable Pump KVA

Transcription:

620 Mobile Piston Pump ADY074 ADY098

Introduction 620 Series Piston Pump Eaton s 620 Series piston pump signifies a stepchange in the generation of hydraulic power. Utilizing the latest developments in hydraulic pump technology, the 620 is specifically designed for moderate flow, high pressure applications. Currently available in 74cc (4.5 in 3 ) and 98cc (6.0 in 3 ) displacements, the 620 is rated for 280 bar making it the ideal pump for an array of different mobile and stationary applications. Capable of generating over 134 horsepower (100kW), the 620 provides more power in a smaller, compact package. This increased power generation allows equipment manufacturers to save money by providing more hydraulic power in a smaller displacement pump. At only 11.4 inches (289 mm) in length, the 98cc fits where other pumps cannot freeing up space for other vehicle system components. The 620 design also incorporates many new advances in product reliability. Once equipment is in the field, failures can prove to be extremely expensive by causing costly downtime. The 620 blends Eaton s long tradition in providing quality pumps with the latest design and technology methods to ensure long lasting product reliability. The result is a very simple design with 28% fewer parts and a B-10 bearing life rated to over 80,000 hours far exceeding the requirements for most applications. Fewer parts also contributes to a lower product weight. 103 lbs (46.6 kg), the 620 98cc is one of the lightest pumps available in its class. A lighter hydraulic pump means lower overall vehicle weight, which results in increased fuel efficiency and lower operating costs for end-users. Lower weight also makes the 620 easier to handle in assembly, maintenance and repair. Eaton employs a unique system of tools and processes, known as Eaton Business System, to ensure quality development and delivery of the 620 product. These tools and process include such known methods as Design for Six Sigma, Lean Manufacturing and ISO certification. Our global network of manufacturing locations and distribution partners enables the 620 to be flexibly configured and delivered throughout the world. Eaton s vision is to be our customer s preferred global supplier of fluid power components. By incorporating the latest advancements in hydraulic pump design and manufacturing, the 620 delivers greater value in terms of power and reliability. Typical Applications Construction Wheel Loaders Motor Graders Concrete Equipment Backhoe Loaders Truck and Bus Vacuum Trucks Telehandler Refuse Trucks Other Mobile Rail Maintenance Forestry Harvester Oil and Gas Drill Rigs Features and Benefits Compact size offers greater flexibility in vehicle system design Increased hydraulic power per displacement Lower maintenance costs due to longer pump life and simpler design Greater fuel savings due to reduced weight and high efficiency design Low Noise resulting from low weight and optimized valve plate 2 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Table of Contents Model Codes......................................................................................................4 Specifications and Performance.......................................................................................6 Control Options Load Sense and Pressure Compensator.........................................................................7 Pressure Compensator.......................................................................................8 Cold Start Valve.............................................................................................9 Performance ADY074..................................................................................................10 ADY098..................................................................................................11 Pump Installation ADY074 C-Mount Side-Ported..............................................................................17 ADY074 Thru-Drive SAE A Option.............................................................................18 ADY074 Thru-Drive SAE B Option.............................................................................19 ADY074 Thru-Drive SAE C Option.............................................................................20 ADY098 C-Mount Side-Ported...............................................................................21 ADY098 Thru-Drive SAE A Option.............................................................................22 ADY098 Thru-Drive SAE B Option.............................................................................23 ADY098 Thru-Drive SAE C Option.............................................................................24 Control Installation Load Sense and Pressure Compensator........................................................................25 Pressure Compensator......................................................................................26 Cold Start Valve............................................................................................27 External Manual Stroke Adjustment..................................................................................28 Input Shaft Options................................................................................................29 Center of Gravity..................................................................................................31 Installation and Start-up.............................................................................................32 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 3

Model Codes 620 Mobile Piston Pump A D Y 0 9 8 R 0 5 A B 1 0 A 2 8 2 0 0 0 0 0 1 0 0 1 0 0 C D 0 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 2 3 Pump Series ADY 620 Series Open Circuit Piston Pump 4 5 6 Pump Displacement 074 74.4 cm 3 /r [4.54 in 3 /r] 098 98.0 cm 3 /r [5.98 in 3 /r] 7 Input Shaft Rotation R Right Hand L Left Hand 8 9 Front Mount and Shaft 05 4 Bolt C, 31.8 mm (1.25) Dia. Keyed Shaft 06 4 Bolt C, 14 Tooth 12/24 Spline 07 4 Bolt C, 38.1 (1.50 in) Dia Straight Keyed 08 4 Bolt C, 17 Tooth 12/24 Spline 10 4 Bolt C, 31.8 mm (1.25 in) Dia. Tapered Keyed Shaft 10 11 Main Ports Size & Location AB 098 Side Ports Suction - 2.5 (Code 61); Pressure - 1 (Code 61) AD 098 Side Ports Suction - 2.5 (Code 61) with M12 Threads; Pressure - 1 (Code 61) with M10 Threads AF 074 Side Ports Suction - 2 (Code 61); Pressure - 1 (Code 61) AH 074 Side Ports Suction - 2 (Code 61) with M12 Threads; Pressure - 1 (Code 61) with M10 Threads 12 Case Drain Ports 1 #16 SAE O-Ring - Top 2 #16 SAE O-Ring - Bottom 3 M33 x 2.0 O-Ring - Top 4 M33 x 2.0 O-Ring - Bottom 13 Diagnostic Pressure Ports Not available on thru-drive units 0 No Diagnostic Pressure Ports 1 #6 SAE O-Ring - Plugged (Rear Ports Only) 14 Controller Type A Pressure Flow Compensator with #4 SAE O-Ring Load Sense Port B Pressure Flow Compensator with M14 Metric O-Ring Load Sense Port C Pressure Compensator Only 15 16 Pressure Compensator Setting (Tolerance on Setting)* 08 76-84 bar (1102-1218 lbf/in 2) 16 156-164 bar (2263-2379 lbf/in 2 ) 20 196-204 bar (2843-2959 lbf/in 2 ) 24 236-244 bar (3423-3539 lbf/in 2 ) 28 276-284 bar (4003-4119 lbf/in 2 ) * Additional Settings Available by Request 4 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Model Codes 620 Mobile Piston Pump A D Y 0 9 8 R 0 5 A B 1 0 A 2 8 2 0 0 0 0 0 1 0 0 1 0 0 C D 0 A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 17 18 Flow Compensator Setting (Tolerance on Setting) 00 No Flow Compensator Setting 14 13-15 bar (189-218 lbf/in 2 ) 20 19-21 bar (276-305 lbf/in 2 ) 30 29-31 bar (421-450 lbf/in2) 19 20 Torque Control Setting 00 No Torque Control 21 22 Control Special Features 00 Control Special Features 0A Bleed Down Orifice 0B 24V Destroke Manifold w/150 Connector Metri Pack 0C 24V Destroke Manifold w/150 Connector Metri Pack and Bleed Down Orifice 23 Maximum Displacement Option 1 Standard Displacement (As Given in Code Title) 2 External Manual Stroke Adjustment 24 25 Auxiliary (Rear) Mount & Output Shaft 00 No Auxiliary Mounting Features AA SAE A 2 Bolt, 9T 16/32 Spline AC SAE B 2/4 Bolt, 13T 16/32 Spline AD SAE B 2/4 Bolt, 15T 16/32 Spline AE SAE C 2/4 Bolt, 14T 12/24 Spline AG Auxillary Mount Ready with Cover Plate 26 Shaft Seal 1 Viton Shaft Seal 27 28 Pump Special Features 00 No Special Features AA Auxiliary Mounting Cover Plate AB Swash Position Sensor 29 30 Paint 00 No Paint CD Blue Primer 31 Identification/Packaging 0 Standard Eaton Identification Box Packaging 32 Design Level A First Design * Additional Settings Available by Request EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 5

Specifications and Performance General Performance Specifications Units ADY065 ADY074 ADY098 ADY120 Displacement cc/r (in 3 /r) 74.4 (4.54) 98.0 (5.98) Weight 1 kg (lbm) 43.6 (96.1) 46.6 (102.7) Pressure 2 Continuous bar (psi) 280 (4060) 280 (4060) Intermittent 3 320 (4600) 320 (4600) Peak 4 350 (5000) 350 (5000) Speed 5 Rated rpm 2400 2200 Max 2825 2600 Min 600 600 Power Max (theoretical) kw (hp) 82.9 (111.1) 100.6 (134.9) Standby 2.1 (2.8) 2.6 (3.5) Torque Max (theoretical) Nm (lb-ft) 329.8 (243.2) 436 (321.6) Bearing Life 6 At 140 bar (2030 psi) B10 Hours 125,205 81,421 At 210 bar (3045 psi) 32,894 21,393 At 280 bar (4060 psi) 12,102 7,870 Mass Moment of Inertia Nm-sec 2 0.0090 0.0118 (lb-in-sec 2 ) (0.079) (0.105) 1 Standard SAE C non-through drive. 2 The 620 is capable of running at higher pressures than shown. In order to not void the warranty, you must provide duty cycle information and receive written approval. 3 Less than 10% of duty cycle. 4 Momentary system pressure spikes only. 5 Ratings based on Flange ports. Rated speed at 1 bar absolute [0 in Hg vac] inlet pressure and 100% displacement. For Max Speed see inlet pressure vs. speed charts. 6 Bearing life ratings at rated speed 1 bar abs (0 psig) inlet. Will vary based on thrust and side loads. For additional information, contact EATON engineering Inlet Pressure, Case Pressure, and Operating Temperature Requirements Inlet Pressure Case Pressure Operating Temperature Maximum Maximum Minimum Maximum Rated Minimum Maximum Continuous Intermittent Peak Rated Temperature Intermittent bar abs (psig) bar abs (in. Hg) bar abs (psig) bar abs (psig) bar abs (psig) bar abs (psig) C ( F) C ( F) C ( F) 1.0 (0) 0.85 (5) 4.4 (50) 1.3 (5) 3.1 (30) 6.2 (75) 93 (200) -25 (-13) 104 (220) Hydraulic Fluids Recommended Minimum Viscosity @ Max. Operating Maximum Maximum Viscosity Intermittent Temperature of Minimum Viscosity Range Continuous at Startup 93 C (200 F) Intermittent Fluid cst (SUS) cst (SUS) cst (SUS) cst (SUS) cst (SUS) Use antiwear hydraulic oil, 16 to 40 (80 to 188) 430 (1192) 2100 (9720) 10 (59) 6 (46) or automotive type crankcase oil (designations SC, SD, SE or SF) per SAE J183 FEB80 For more information, see Eaton publication 579. For operation on other alternative or environmentally friendly fluids, please contact your Eaton Representative. 6 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Control Options Load Sense and Pressure Compensator Load Sense and Pressure Compensator Control The pump will provide power matching of pump output to system load demand, maximizing efficiency and improving load metering characteristics of any directional control valve installed between the pump and the load. Load sensing ensures that the pump always provides only the amount of flow needed by the load. At the same time, the pump operating pressure adjusts to the actual load pressure plus a pressure differential required for the control action. When the system is not demanding power, the load sense control will operate in an energy-saving stand-by mode. Typically, the differential pressure is that between the pressure inlet and service port of a proportionally controlled directional valve, or a load sensing directional control valve. See the model code on page 4 for differential pressure settings for load sensing. If the load pressure exceeds the system pressure setting, the pressure compensator de-strokes the pump. The load sensing line must be as short as possible and can also be used for remote control or unloading of the pump pressure. For remote control purposes, it is recommended that you contact your Eaton Representative for the correct configuration of the control. Warning: 1) When adjusting the pressure limiter, install a 0 to 350 bar (0 to 5000 psi) gage in the outlet gage port and limit the pressure setting to the continuous rated pressure for the pump displacement shown on page 6. It is possible to adjust the pressure compensator beyond the rated pressure of the pump. Doing so, may void the warranty of the 620 pump. 2) EATON recommends use of relief valve in all systems Pressure Limit Settings The pressure compensator uses two springs to cover the full pressure range of the ADY pumps. The high pressure spring covers the range from 140 bar (2050 psi) to 280 bar (4060 psi). The low pressure spring is adjustable from minimum pressure through 140 bar (2050 psi). Flow Compensator (Load Sense) Settings There are three springs used to cover the load sense adjustment range of this control. Typical Operating Curve F case drain K inlet gage port (optional) K outlet gage port (optional) Outlet Flow Q Outlet Pressure B inlet To load Optional bleed-down orifice with control special feaure "OA". ø 0.4 mm (.015 in.). Orifice is plugged for no bleed down in control. C outlet Dynamic Response per SAE J745 (Using Swash Plate Position) Response Recovery Load Sense (off stroke) (on stroke) Recovery msec msec msec ADY074 30 90 155 ADY098 30 70 125 P J load sense signal port EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 7

Control Options Pressure Compensator Pressure Compensator Control The pump will provide a continuously modulated flow to meet changing load demands at a pre-adjusted compensator pressure. At pressures below the compensator setting, the pump will operate at maximum displacement. See model code on page 4 for compensator pressure ranges. Pressure Limit Settings The pressure compensator uses two springs to cover the full pressure range of the ADY pumps. The high pressure spring covers the range from 140 bar (2050 psi) to 280 bar (4060 psi). The low pressure spring is adjustable from minimum pressure through 140 bar (2050 psi). F Case Drain K Inlet Gage Port K Outlet Gage Port + + B Inlet To Load See Model Code on Page 4 for Spring (Pressure) Adjustment Ranges. C Outlet Warning: 1) When adjusting the pressure limiter, install a 0 to 350 bar (0 to 5000 psi) gage in the outlet gage port and limit the pressure setting to the continuous rated pressure for the pump displacement shown on page 6. It is possible to adjust the pressure compensator beyond the rated pressure of the pump. Doing so, may void the warranty of the 620 pump. 2) EATON recommends use of relief valve in all systems. Pressure Cut-off Characteristics of Pressure Compensator Control @ 49 C (120 F), Static Conditions. Outlet Flow Q Outlet Pressure P Dynamic Response per SAE J745 (Using Swash Plate Position) Response (off stroke) Recovery (on stroke) msec msec ADY074 30 90 ADY098 30 70 8 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Control Options Cold Start Valve Cold Start Valve The 620 Cold Start Valve reduces pump start-up torque by directing control pressure to the outlet. It is primarily used in cold weather applications and includes a 12 or 24 VDC directional control valve mounted between the pump housing and compensator. F Case Drain K Inlet Gage Port (Optional) B Inlet Optional bleed down orifice with control special feature "0A". Ø 0.4mm (0.015 in). Orifice is plugged for no bleed down in control. J Load Sense Signal Port K Outlet Gage Port (Optional) C Outlet To Load EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 9

Performance ADY074 Overall Efficiency Versus Speed @ 49ºC (120ºF), Full Flow, and 1.0 bar (0 psi) Inlet 90 88 86 84 82 140 bar (2030 psi) 210 bar (3045 psi) Efficiency (%) 80 78 76 74 72 70 68 280 bar (4060 psi) 66 500 1000 1500 2000 2500 Input Speed (rpm) Overall Efficiency Versus Speed @ 49ºC (120ºF), Full Flow, and 1.0 bar (0 psi) Inlet 90 88 86 84 82 70 bar (1088 psi) 30 bar (435 psi) Efficiency (%) 80 78 76 74 72 70 68 66 500 1000 1500 2000 2500 Input Speed (rpm) 10 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Performance ADY074 Input Power Versus Speed @ 49ºC (120ºF), Full Flow, and 1.0 bar (0 psi) Inlet 90 (121) 80 (107) 280 bar (4060 psi) Input Power Kw (hp) 70 (94) 60 (80) 50 (67) 40 (54) 30 (40) 20 (27) 10 (13) 210 bar (3045 psi) 140 bar (2030 psi) 70 bar (1088 psi) 30 bar (435 psi) 0 500 1000 1500 2000 2500 Input Speed (rpm) Input Torque Versus Speed @ 49ºC (120ºF), Full Flow, and 1.0 bar (0 psi) Inlet 400 (3540) 350 (3098) 280 bar (4060 psi) Input Torque Nm (in-lb) 300 (2655) 250 (2213) 200 (1770) 150 (1328) 100 (885) 50 (443) 210 bar (3045 psi) 140 bar (2030 psi) 70 bar (1088 psi) 30 bar (435 psi) 0 500 1000 1500 2000 2500 Input Speed (rpm) EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 11

Performance ADY074 Delivery and Case Flow Versus Speed @ 49ºC (120ºF) 200 (44) 160 (35) 29 bar (417 psi) 280 bar (4067 psi) Main Flow, lpm (gpm) 120 (26) 80 (18) 280 bar (4067 psi) 12.0 (2.6) 10.0 (2.2) 8.0 (1.8) 6.0 (1.3) Case Flow, lpm (gpm) 40 (9) 29 bar (417 psi) 4.0 (0.9) 2.0 (0.4) 0 0.0 500 1000 1500 2000 2500 Input Speed (rpm) 12 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Performance ADY098 Overall Efficiency Versus Speed @ 49ºC (120ºF), Full Flow, and 1.0 bar (0 psi) Inlet 90 88 86 84 82 175 bar (2540 psi) 210 bar (3045 psi) Efficiency (%) 80 78 76 74 72 70 68 245 bar (3550 psi) 280 bar (4060 psi) 66 500 1000 1500 2000 Input Speed (rpm) Overall Efficiency Versus Speed @ 49ºC (120 F), Full Flow, and 1.0 bar (0 psi) Inlet 90 88 86 84 82 105 bar (1522 psi) Efficiency (%) 80 78 76 74 72 70 68 140 bar (2030 psi) 70 bar (1015 psi) 35 bar (507 psi) 66 500 1000 1500 2000 Input Speed (rpm) EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 13

Performance ADY098 Inlet Pressure Versus Speed @ 49ºC (120ºF) 0.7 (10) Displacement 100% 90% 80% 0.5 (8) 0.4 (6) Inlet Pressure bar (psi).03 (4) 0.1 (2) 0-0.1 (-2) -0.3 (-4) 2000 2100 2200 2300 2400 2500 2600 Shaft Speed (rpm) Noise Data 85 80 2200 rpm 50% flow 2200 rpm full flow 1000 rpm 50% flow Noise level (dba) 75 70 1000 rpm full flow 65 60 0 1000 2000 3000 4000 5000 Outlet pressure (psi) 14 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Performance ADY098 Input Power Versus Speed @ 49ºC (120ºF), Full Flow, and 1.0 bar (0 psi) Inlet 120 (161) 100 (134) 280 bar (4060 psi) Input Power, Kw (hp) 80 (107) 60 (80) 40 (54) 210 bar (3045 psi) 140 bar (2030 psi) 20 (27) 70 bar (1015 psi) 35 bar (507 psi) 0 500 1000 1500 2000 Input Speed (rpm) Input Torque Versus Speed @ 49ºC (120ºF), Full Flow, and 1.0 bar (0 psi) Inlet 500 (4425) 280 bar (4060 psi) 400 (3540) Input Torque, Nm (in-lb) 300 (2655) 200 (1770) 210 bar (3045 psi) 140 bar (2030 psi) 100 (885) 70 bar (1015 psi) 35 bar (507 psi) 0 500 1000 1500 2000 Input Speed (rpm) EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 15

Performance ADY098 Delivery and Case Flow Versus Speed @ 49ºC (120ºF) 240 (53) 35 bar (507 psi) 200 (44) 280 bar (4060 psi) Main Flow, lpm (gpm) 160 (35) 120 (26) 80 (18) 40 (9) 280 bar (4060 psi) 35 bar (507 psi) 10.0 (2.2) 8.0 (1.8) 6.0 (1.3) 4.0 (0.9) 2.0 (0.4) Case Flow, lpm (gpm) 0 500 1000 1500 2000 0.0 Input Speed (rpm) Input Torque and Case Flow Stand-by @ 49ºC (120ºF) Input Torque and Case Flow Cut-off @ 49ºC (120ºF) 20.0 (177) 140 (1239) Input Torque, Nm (in-lb) 16.0 (142) 12.0 (106) 8.0 (71) 4.0 (35) 20 bar (290 psi) Torque 11 bar (160 psi) Torque Case Flow 8.0 (1.8) 6.0 (1.3) 4.0 (0.9) 2.0 (0.4) Case Flow, lpm (gpm) Input Torque, Nm (in-lb) 120 (1062) 280 bar (4060 psi) 100 (885) 80 (708) 60 (531) 16.0 (3.5) 280 bar (4060 psi) Case Flow 12.0 (2.6) 150 bar (2175 psi) Case Flow 40 (354) 8.0 (1.8) 150 bar (2175 psi) Torque 20 (177) 4.0 (0.9) Case Flow, lpm (gpm) 0. 500 1000 1500 2000 Input Speed (rpm) 0.0 0 500 1000 1500 2000 0 Input Speed (rpm) 16 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Pump Installation ADY074 C-Mount /Side-Ported RH Rotation Top Case Drain 127.2 [5.01] 99.4 [3.91] 93.5 [3.68] 60.0 [2.36] 99.4 [3.91] 93.5 [3.68] A A 39.0 [1.54] Optional Diagnostic Port 39.0 [1.54] For Compensator Configuration See Separate Compensator Installation Drawing Optional Diagnostic Port 72.3 [2.85] 52.4 [2.06] Pressure Port 4X.375-16 UNC-2B (M10 x 1.5-6H OPTIONAL) 14.5[.57] 57.0 26.2 [1.03] 247.9 [9.76] 231.5 [9.11] For Shaft Configuration See Separate Shaft Installation Drawing 114.5 [4.51] 4X Ø15.0 [0.59] 113.5 [4.47] 147.0 [5.79] 88.0 [3.46] (Case Drain) 93.0 104.7 [3.66] [4.12] (Case Drain) Bottom Case Drain 101.7 [4.00] 12.5 [0.49] 127.0 [5.00] 273.9 [10.78] View A-A 4X.500-13 UNC-2B (M12 X 1.75-6H OPTIONAL) 30.2[1.19] LH Rotation 77.8 [3.06] Pressure Port Suction Port 235.7 [9.28] 42.9 [1.69] EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 17

Pump Installation ADY074 Thru-Drive SAE A Thru-Drive SAE A 53.2 [2.09] 106.4 [4.19] Ø82.6 [3.25] Groove to Accept an AS 568A Size 152 O-ring 53.2 [2.09] 106.4 [4.19] Dual 2-Bolt A-Mounting Flange Per SAE J744-82-2 301.5 [11.87] A Thru-Drive Cover Plate Installation 9.5 [.38] 15.9 [.63] 106.4 [4.19] 106.4 [4.19] Optional Mounting Position Output Shaft Installation 9T Spline Maximum Torque 58 Nm [513 in-lbf] Output Shaft Installation 11T Spline Maximum Torque 124 Nm [1100 in-lbf] 41.9 [1.65] Ø16.54[.651] 9 Tooth 30 flat Root Side Fit 16/32 Class 6 per ANSI B92.1-1996 Accepts 9 Tooth 16/32 Pitch Flat Root Side Fit Involute Spline Per SAE J744-16-4 Additional Unit Drive by This Spline Must Not Require More Than 58 Nm (513 in-lbf) of Torque 50.7 [1.99] Ø19.71[.776] 11 Tooth 30 flat Root Side Fit 16/32 Class 6 per ANSI B92.1-1996 Flat Root Side Fit Involute Spline Accepts 11 Tooth 16/32 Pitch Per SAE J744-16-4 Additional Unit Drive by This Spline Must Not Require More Than 124 Nm (1100 in-lbf) of Torque 18 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Pump Installation ADY074 Thru-Drive SAE B Thru-Drive SAE B Groove to Accept an AS 568A Size 1525O-ring 6X.500-13 UNC-2B For Output Shaft Configuration See Separate Shaft Installation Drawing Ø101.7 [4.00] 118.0 [4.65] 89.8 [3.54] 89.8 [3.54] 146.0 [5.75] 175.2 [6.90] "X" Output Shaft Dim X 13 T spline 301.5 [11.87] 15 T spline 317.4 [12.50] B-Thru-Drive Cover Plate Installation 9.7 [0.38] 18.0 [0.71] Output Shaft Installation 13T Spline Maximum Torque 209 Nm [1850 in-lbf] 41.7 [1.64] Ø22.88[.901] 13 Tooth 30 Flat Root Side Fit 16/32 Class 6 per ANSI B92.1a-1996 Accepts 13 Tooth 16/32 Pitch Flat Root Side Fit Involute Spline Per SAE J744-22-4 Additional Unit Drive by This Spline Must Not Require More Than 209 Nm (1850 in-lbf) of Torque Output Shaft Installation 15T Spline Maximum Torque 338 Nm [2987 in-lbf] 46.0 [1.81] Ø25.68[1.0110] 15 Tooth 30 Flat Root Side Fit 16/32 Class 6 Per ASA B5-15-1960 Accepts 15 Tooth 16/32 Pitch Flat Root Side Fit Involute Spline Per SAE J744-25-4 Additional Unit Drive by This Spline Must Not Require More Than 338 Nm (2987 in-lbf) of Torque EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 19

Pump Installation ADY074 Thru-Drive SAE C Thru-Drive SAE C Groove to Accept an AS 568A Size 159 O-ring 4 X 1/2-13 UNC-2B Thru For Output Shaft Configuration See Separate Shaft Installation Drawing 142.7 [5.62] 114.5 [4.51] 114.5 [4.51] 181.0 [7.13] 214.4 [8.44] 2X 5/8-11 UNC-2B Thru 325.4 [12.81] C-Thru-Drive Cover Plate Installation 9.7 [0.38] 20.0 [0.79] 181.0 [7.13] Output Shaft Installation 14T Spline Maximum Torque 640 Nm [5660 in-lbf] 60 [2.36] Ø32.08[1.2630] 14 Tooth 30 Flat Root Side Fit 12/24 Class 6 Per ASA B5-15-1960 Accepts 14 Tooth 12/24 Pitch Flat Root Side Fit Involute Spline Per SAE J744-32-4 Additional Unit Drive by This Spline Must Not Require More Than 640 Nm (5660 in-lbf) of Torque Output Shaft Installation 17T Spline Maximum Torque 760 Nm [6725 in-lbf] 62 [2.44] Ø38.94[1.533] 17 Tooth 30 Flat Root Side Fit 12/24 Class 6 Per ASA B92.1-1976 Accepts 17 Tooth 16/32 Pitch Flat Root Side Fit Involute Spline Per SAE J744-38-4 Additional Unit Drive by This Spline Must Not Require More Than 760 Nm (6725 in-lbf) of Torque 20 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Pump Installation Available from Cross Company Fluid Power Group 336.856.6985 ADY098 C-Mount / Side-Ported 254.5 [10.02] (Diagnostic Port) RH Rotation Top Case Drain C-Mount 4 Bolt / Side-Ported 99.4 [3.91] 99.4 [3.91] 93.5 [3.68] Optional Diagnostic Port 127.2 [5.01] 60.0 [2.36] 93.5 [3.68] 39.0 [1.54] 247.6 [9.75] (Diagnostic Port) For Compensator Configuration See Separate Compensator Insatllation Drawing 50.0 [1.97] A 50.0 [1.97] Optional Diagnostic Port For Shaft Configuration See Separate Shaft Insatllation Drawing 60 70.0 [2.76] A 51.6 [2.03] 147.0 [5.79] 88.0 [3.46] (Case Drain) 114.5 [4.51] Pressure Port 4X.375-16 UNC-2B (M10 X 1.5-6H Optional) 14.5 [.57] 4X Ø15.0 [.59] Bottom Case Drain 101.7 [4.00] 93.0 101.7 [3.66] [4.00] (Case Drain) 113.5 [4.47] 12.5 [.49] Ø127.0 [5.00] 288.0 [11.34] LH Rotation View A-A 4X.50-13 UNC-2B (M12 X 1.75-6H OPTIONAL) 30.2 [1.19] Suction Port Pressure Port Suction Port 241.7 [9.52] EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 21

Pump Installation ADY098 Thru-Drive SAE A Thru-Drive SAE A 53.2 [2.09] 106.4 [4.19] Ø82.6 [3.25] Groove to Accept an AS 568A Size 152 O-ring 53.2 [2.09] 106.4 [4.19] Dual 2-Bolt A-Mounting Flange Per SAE J744-82-2 318.1 [12.52] A Thru-Drive Cover Plate Installation 9.5 [.38] 15.9 [.63] 106.4 [4.19] 106.4 [4.19] Optional Mounting Position Output Shaft Installation 9T Spline Maximum Torque 58 Nm [513 in-lbf] Output Shaft Installation 11T Spline Maximum Torque 124 Nm [1100 in-lbf] 41.9 [1.65] 50.7 [1.99] Ø16.54[.651] 9 Tooth 30 flat Root Side Fit 16/32 Class 6 per ANSI B92.1-1996 Accepts 9 Tooth 16/32 Pitch Flat Root Side Fit Involute Spline Per SAE J744-16-4 Additional Unit Drive by This Spline Must Not Require More Than 58 Nm (513 in-lbf) of Torque Ø19.71[.776] 11 Tooth 30 flat Root Side Fit 16/32 Class 6 per ANSI B92.1-1996 Flat Root Side Fit Involute Spline Accepts 11 Tooth 16/32 Pitch Per SAE J744-16-4 Additional Unit Drive by This Spline Must Not Require More Than 124 Nm (1100 in-lbf) of Torque 22 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Pump Installation ADY098 Thru-Drive SAE B Thru-Drive SAE B Groove to Accept an AS 568A Size 1525O-ring 6X.500-13 UNC-2B For Output Shaft Configuration See Separate Shaft Installation Drawing Ø101.7 [4.00] 118.0 [4.65] 89.8 [3.54] 89.8 [3.54] 146.0 [5.75] 175.2 [6.90] 318.1 [12.52] B-Thru-Drive Cover Plate Installation 9.7 [0.38] 18.0 [0.71] Output Shaft Installation 13T Spline Maximum Torque 209 Nm [1850 in-lbf] 41.7 [1.64] Output Shaft Installation 15T Spline Maximum Torque 338 Nm [2987 in-lbf] 58.3 [2.30] Ø22.88[.901] 13 Tooth 30 Flat Root Side Fit 16/32 Class 6 per ANSI B92.1a-1996 Accepts 13 Tooth 16/32 Pitch Flat Root Side Fit Involute Spline Per SAE J744-22-4 Additional Unit Drive by This Spline Must Not Require More Than 209 Nm (1850 in-lbf) of Torque Ø25.68[1.0110] 15 Tooth 30 Flat Root Side Fit 16/32 Class 6 per ASA B5-15-1960 Accepts 15 Tooth 16/32 Pitch Flat Root Side Fit Involute Spline Per SAE J744-25-4 Additional Unit Drive by This Spline Must Not Require More Than 338 Nm (2987 in-lbf) of Torque EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 23

Pump Installation ADY098 Thru-Drive SAE C Thru-Drive SAE C Groove to Accept an AS 568A Size 159 O-ring 4 X 1/2-13 UNC-2B Thru For Output Shaft Configuration See Separate Shaft Installation Drawing 142.7 [5.62] 114.5 [4.51] 114.5 [4.51] 181.0 [7.13] 214.4 [8.44] 2X 5/8-11 UNC-2B Thru 326.1 [12.84] C-Thru-Drive Cover Plate Installation 9.7 [0.38] 20.0 [0.79] 181.0 [7.13] Output Shaft Installation 14T Spline Maximum Torque 640 Nm [5660 in-lbf] 64.0 [2.52] Ø32.08[1.2630] 14 Tooth 30 Flat Root Side Fit 12/24 Class 6 Per ASA B5.15-1960 Accepts 14 Tooth 12/24 Pitch Flat Root Side Fit Involute Spline Per SAE J744-32-4 Additional Unit Drive by This Spline Must Not Require More Than 640 Nm (5660 in-lbf) of Torque Output Shaft Installation 17T Spline Maximum Torque 760 Nm [6725 in-lbf] 60.3 [2.37] Ø38.94[1.533] 17 Tooth 30 Flat Root Side Fit 12/24 Class 6 per ANSI B92.1a-1976 Accepts 17 Tooth 16/32 Pitch Flat Root Side Fit Involute Spline Per SAE J744-38-4 Additional Unit Drive by This Spline Must Not Require More Than 760 Nm (6725 in-lbf) of Torque 24 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Control Installation Load Sense and Pressure Compensator 70.4 [2.77] 168.5 [6.63] 130.9 [5.15] 198.8 [7.83] EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 25

Control Installation Pressure Compensator 158.1 [6.22] 119.8 [4.72] 71.9 [2.83] 126.1 [4.96] 140.3 [5.52] 26 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Control Installation Cold Start Valve Load Sense Port 92.3 [3.63] 124.5 [4.90] 74.3 [2.93] 78.7 [3.10] 72.73 [2.863] 187.42 [7.379] 141.9 [5.59] 201.65 [7.939] 164 [6.46] 198.8 [7.83] 158.1 [6.22] 45.4 [1.79] 119.8 [4.72] 78.7 [3.10] 71.91 [2.831] 159.22 [6.269] 141.9 [5.59] 12 VCD Flying Lead Coil Shown See Below For Options 173.4 [6.83] Optional Connectors Deusch Option Metri-Pack 280 Option Metri-Pack 150 Option EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 27

External Manual Stroke Adjustment Maximum Stroke Limiter Max displacement is Reduced By Approximately 5 to 6% Per Clockwise Turn 11.0 [0.43] Max Displacement 1.2 [0.05] 60% of Max Displacement Compensator/Control Not Shown for Clarity 10 115.1 [4.53] 206.8 [8.14] 28 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Input Shaft Options 05 Code Maximum Torque 450 Nm [3980 in-lbf] 56.0 [2.20] 34.9 [1.38] 7.94 +.03 -.01.313 +.001 -.000 Key Width [ ] 2.0 [.08] 06 Code Maximum Torque 640 Nm [5660 in-lbf] 56.0 [2.20] Ø31.05[1.2262] 14 Tooth 30 Flat Root Side Fit 12/24 Per ANSI B92.1a-1976 Fit 14 Tooth 30 Flat Root Side Fit 12/24 Internal Splines Per ASA B5.15-1960 Class 6 35.19 [1.385] Ø31.70 +.06 -.00 [ 1.248 +.002 -.000 ] 07 Code Maximum Torque 765 Nm [6770 in-lbf] Ø38.05 +.05 -.00 [1.498 +.001 -.000 ] 08 Code Maximum Torque 765 Nm [7665 in-lbf] 62.0 [2.44] 25.1 [.99] 9.53 +.03 -.00.375 +.001 -.000 Key Width [ ] 2.0 [.08] 62.0 [2.44] Ø37.49[1.476] 17 Tooth 30 Flat Root Side Fit 12/24 Per ANSI B92.1a-1976 Fit 17 Tooth 30 Flat Root Side Fit 12/24 Internal Splines Per ANSI B92.1a-1976 Class 6 42.2 [1.66] EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 29

Input Shaft Options 10 Code Maximum Torque 640 Nm [5660 in-lbf] 4.6 [.18] 6.1 [.24] B 22.26 [.876].750-16 UNF-2A 7.950±.013 [.3130±.0005] 64.0 [2.52] 3.81 [.150] B 34.93 [1.375] 8.00 [.315] 65.19 [2.567] 125:1000 [1.500:12] SECTION B-B 30 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

Center of Gravity L3 L1 L4 Lt L2 Side Port Thru-Drive SAE Pad Length Lcg L3 L4 Lcg L3 L4 Lt ADY074 135.6 (5.34) 9.5 (0.37) 2.2 (0.09) A 141.3 (5.56) 9.2 (0.36) 2.1 (0.08) 301.5 (11.87) B (13T SPLINE) 144.4 (5.68) 9.0 (0.35) 2.0 (0.08) 301.5 (11.87) B (15T SPLINE) 148.1 (5.83) 8.8 (0.34) 2.0 (0.08) 317.4 (12.50) C 153.0 (6.02) 8.6 (0.33) 1.9 (0.07) 325.4 (12.81) ADY098 139.7 (5.50) 8.2 (0.32) 2.2 (0.09) A 145.8 (5.74) 7.8 (0.31) 2.2 (0.08) 318.1 (12.52) B 149.3 (5.88) 7.6 (0.30) 2.1 (0.08) 318.1 (12.52) C 153.8 (6.06) 7.5 (0.30) 2.6 (0.10) 326.1 (12.84) Examples: Calculation L 1 and L 2 Tandem ADY098 Thru-drive with ADY098 Side Ported L 1 = Lcg L 2 = Lt + Lcg 153.8mm (6.06 in) 318.1mm + 139.7mm = 457.8mm (18.0 in) Tandem Pump Applications Eaton recommends that tandem pump applications be provided with additional support to limit overhung loading of the mounting flange. The thru-drive alternate attachment points on the rear flange may be used with a customer designed support. EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 31

Installation and Start-up Warning: Care should be taken that mechanical and hydraulic resonances are avoided in the application of the pump. Such resonances can seriously compromise the life and/or safe operation of the pump. Drive Data Mounting attitude should be horizontal using the appropriate case drain ports to ensure that the case remains full of fluid at all times. Consult your local Eaton Representative if a different arrangement is required. In those cases where geometric tolerances of mounting are critical, or where specific tolerance ranges are required and not specified, consult Eaton Engineering for specific limits. Direction of shaft rotation, viewed from the prime mover end, must be as indicated in the model designation on the pump either right hand (clockwise) or left hand (counterclockwise). Direct coaxial drive through a flexible coupling is recommended. If drives imposing radial shaft loads are considered, please consult your Eaton Representative. Start-up Procedure Make sure the reservoir and circuit are clean and free of dirt/debris prior to filling with hydraulic fluid. Fill the reservoir with filtered oil and fill to a level sufficient enough to prevent vortexing at the suction connection to pump inlet. It is good practice to clean the system by flushing and filtering, using an external slave pump. Caution: Before the pump is started, fill the case through the uppermost drain port with hydraulic fluid of the type to be used. The case drain line must be connected directly to the reservoir and must terminate below the oil level. Once the pump is started, it should prime within a few seconds. If the pump does not prime, check to make sure that there are no restrictions between the reservoir and the inlet to the pump, and that the pump is being rotated in the proper direction, and that there are no air leaks in the inlet line and connections. Also check to make sure that trapped air can escape at the pump outlet. After the pump is primed, tighten the loose outlet connections, then operate for five to ten minutes (unloaded) to remove all trapped air from the circuit. If the reservoir has a sight gage, make sure the fluid is clear not milky. Fluid Cleanliness The 620 Series pumps are rated in anti-wear petroleum fluids with a contamination level of 21/18/13 per ISO 4066. Operation in fluids with levels more contaminated than this is not recommended. Fluids other than petroleum, severe service cycles, or temperature extremes are cause for adjustment of these codes. Please contact your Eaton Representative for specific duty cycle recommendation. Eaton 620 Series pumps, as with any variable displacement piston pumps, will operate with apparent satisfaction in fluids up to the rating specified here. Experience has shown however, that pump and hydraulic system life is not optimized with high fluid contamination levels (high ISO cleanliness codes). Proper fluid condition is essential for long and satisfac tory life of hydraulic components and systems. Hydraulic fluid must have the correct balance of cleanliness, materials, and additives for protection against wear of components, elevated viscosity and inclusion of air. Essential information on the correct methods for treating hydraulic fluid is included in Eaton publication 561 Eaton Guide to Systemic Contamination Control available from your local Eaton distributor. In this publication, filtration and cleanliness levels for extending the life of axial piston pumps and other system components are listed. Included is an excellent discussion of the selection of products needed to control fluid condition. 32 EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012

EATON 620 Mobile Piston Pump Technical Manual E-PUPI-TM017-E2 August 2012 33

Eaton Hydraulics Group USA 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 952-937-9800 Fax: 952-294-7722 www.eaton.com/hydraulics Eaton Hydraulics Group Europe Route de la Longeraie 7 1110 Morges Switzerland Tel: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601 Eaton Hydraulics Group Asia Pacific Eaton Building No.7 Lane 280 Linhong Road Changning District, Shanghai 200335 China Tel: (+86 21) 5200 0099 Fax: (+86 21) 2230 7240 2012 Eaton Corporation All Rights Reserved Printed in USA Document No. E-PUPI-TM017-E2 August 2012