Improved Aromatic Acids Analysis: Saving Significant Time, Solvent, Sample and Money with 1.9 µm Agilent InfinityLab Poroshell 120 Columns

Similar documents
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

A Complete Solution for Method Linearity in HPLC and UHPLC

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

How To Use An Agilent 9 Infinity Lc

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Protocol: HPLC (amino acids)

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

PAPER CHROMATOGRAPHY

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

FREE SAMPLE PACK Just ask.

Chemical analysis service, Turner s Green Technology Group

Q-TOF User s Booklet. Enter your username and password to login. After you login, the data acquisition program will automatically start.

Expectations for GC-MS Lab

Filter Vials. Product Knowledge. PTFE PVDF Nylon PES. Pat. US #7,790,117 Worldwide patents pending. Thomson Instrument Company Toll Free

How To Use An Acquity Qda Detector

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Thermo Scientific Vanquish UHPLC System. Revolutionize Your. UHPLC Experience

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

Analysis of Liquid Samples on the Agilent GC-MS

Robert Birdsall, Eoin Cosgrave, Henry Shion, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Separation of Amino Acids by Paper Chromatography

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

Diffusion and Fluid Flow

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Fractional Distillation and Gas Chromatography

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

designed to never let you down PerkinElmer Series 200 HPLC Systems

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

The Theory of HPLC. Gradient HPLC

Determination of Caffeine in Beverages HPLC-1

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Smartline HPLC by design

How To Test For Contamination In Large Volume Water

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Quantitative Evaluation of Perfume Fleuressence Samples using the znose

Analysis of Fat-Soluble Vitamin Capsules using UltraPerformance Convergence Chromatography (UPC 2 )

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

The LC Handbook Guide to LC Columns and Method Development

Gas Chromatography Liner Selection Guide

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Electrospray Ion Trap Mass Spectrometry. Introduction

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

HypercarbColumns 100% porous graphitic carbon for extended separation capabilities

GC-xt. The most flexible GC /GC-MS liquid sample injector

SUCRALOSE. White to off-white, practically odourless crystalline powder

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Purification of reaction mixtures using flash chromatography.

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

Oasis HLB Cartridges and 96-Well Plates

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Ultra High Performance Liquid Chromatograph. Nexera XR C196-E082B

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Tips & Tricks GPC/SEC: Analysis and Calibration For Low Molar Mass Macromolecules

Introduction to HPLC. Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke. Introduction to HPLC p.1/17

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Analytical Test Report

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

ChromQuest 5.0 Chromatography Data System

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Supplementary Materials and Methods (Metabolomics analysis)

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Background Information

PURIFICATION. Preparative Chromatography Modular Solutions from Manual Systems to Full Automation. Scale Up. Reverse. Phase. Impurity Isolation

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study

SPE and HPLC. Dr Iva Chianella Lecturer in Analytical Chemistry Cranfield Health +44 (0)

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

The Use of Hydrogen Carrier Gas for GC/MS

Transcription:

Improved Aromatic Acids Analysis: Saving Significant Time, Solvent, Sample and Money with 1.9 µm Agilent InfinityLab Poroshell 12 Columns Application Note Agriculture, Food Testing, Small Molecule Pharmaceuticals Author Anne Mack Agilent Technologies, Inc. Wilgton, DE, USA Abstract Six aromatic acids were analyzed using a formic acid and acetonitrile gradient. The performance of four columns was evaluated for this separation. The original analysis was performed on a 4.6 25 mm, 5 µm totally porous particle Agilent ZRBAX Eclipse Plus C18 column, and compared to 1.9, 2.7, and 4 µm superficially porous particle Agilent InfinityLab Poroshell 12 EC-C18 columns in 2.1 5 mm format. The selectivity of all columns was similar, requiring no method development between column comparisons. All columns achieved successful separation of the aromatic acids, with a imum resolution of 1.8. Compared to the long 5 µm column, the short 1.9 µm InfinityLab Poroshell 12 EC-C18 column was able to achieve better imum resolution (2.9 versus 2.4), 12x faster, while using 96 % less mobile phase and 75 % less sample. Further method modifications showed that the 1.9 µm InfinityLab Poroshell 12 EC-C18 column can be pushed even faster to fully resolve these six aromatic acids in.35 utes, with a imum resolution of 2.3 at a speed 13x faster than the original analysis.

Introduction Superficially porous particle LC columns are a popular tool in liquid chromatography. Superficially porous particle columns generate high efficiency at lower pressure, relative to their totally porous particle column counterparts 1. This is primarily due to a shorter mass transfer distance and substantially narrower particle size distribution of the particles in the column 2. The current trend with superficially porous particles is reducing particle size for further efficiency improvements. The higher efficiency can be used to speed up analyses or improve results by increasing resolution and sensitivity. Within the Agilent family of LC columns, significant work has been done to ensure easy method transferability and scalability. Stationary phase chemistries are similar among totally porous particle Agilent ZRBAX and superficially porous particle Agilent InfinityLab Poroshell columns so that methods can easily be updated without needing further method development 3. This work shows how small Poroshell particles can be used to improve a separation of aromatic acids compared to a traditional 5 µm analyses. Significant time, solvent, sample, and money savings are demonstrated with the use of Poroshell columns. Experimental An Agilent 129 Infinity LC system was used in this experiment. The system was modified from its standard configuration to have low system volume and dispersion. Table 1 shows the configuration details and the four Agilent LC columns used in this experiment. Table 2 shows the LC method parameters for all analyses. With the exception of the fast 1.9 µm analysis, all methods were geometrically scaled according to column volume to preserve the chromatographic separation from column to column. Table 1. UHPLC system configuration. Agilent 129 Infinity LC System Configuration Agilent 129 Infinity Binary Pump (G422A) Agilent 129 Infinity High Performance Autosampler (G4226A) Agilent 129 Infinity Thermostatted Column Compartment (G1316C) Agilent 129 Infinity Diode Array Detector (G4212A) Agilent penlab CDS ChemStation Edition, revision C.1.5 [35] G422A: B.6.53 [13] G4226A: A.6.5 [3] G1316C: A.6.53 [2] G4212A: B.6.53 [13] 35 µl Solvent mixer: Agilent Jet Weaver, 35 µl/1 µl (G422-66) Seat assembly, ultralow dispersion, for Agilent 129 Infinity Autosampler (G4226-873) Autosampler to heater: capillary, stainless steel,.75 22 mm, SV/SLV (567-4784) Vial, screw top, amber with write-on spot, certified, 2 ml, 1/pk (5182-716) Cap, screw, blue, PTFE/red silicone septa, 1/pk (5182-717) Vial insert, 25 µl, glass with polymer feet, 1/pk (5181-127) Heat exchanger, low dispersion, 1.6 µl, double (G1316-65) Heater to column: InfinityLab Quick Connect assembly, 15 mm,.75 mm (567-5961) Column to flow cell: capillary, stainless steel,.75 22 mm, SV/SLV (567-4784) Agilent Ultralow dispersion Max-Light cartridge flow cell, 1 mm (G4212-638) Agilent LC Columns Agilent ZRBAX Eclipse Plus C18, 4.6 x 25 mm, 5 µm (95999-92) Agilent InfinityLab Poroshell 12 EC-C18, 2.1 5 mm, 1.9 µm (699675-92) Agilent InfinityLab Poroshell 12 EC-C18, 2.1 5 mm, 2.7 µm (699775-92) Agilent InfinityLab Poroshell 12 EC-C18, 2.1 5 mm, 4 µm (69977-92) Table 2. UHPLC method parameters. Column Mobile phase Agilent ZRBAX Eclipse Plus C18, 4.6 25 mm, 5 μm 2.1 5 mm, 1.9 μm 2.1 5 mm, 2.7 μm 2.1 5 mm, 4 μm 2.1 5 mm, 1.9 μm (fast) A).2 % formic acid in water B) acetonitrile Flow rate (ml/) Gradient 1. 8 35 %B in 36 utes.5 8 35 %B in 3 utes 2.2 8 26 %B in.3 utes Injection volume (μl) Sample 2.1 mg/ml each of protocatechuic acid, 5 3,4-dihydroxyphenylacetic acid (DPAC), 4-aobenzoic acid (PABA), vanillic acid, syringic acid, salicylic acid in water Compounds are listed in elution order, see Figure 1 for structures. Thermostatted Column Compartment ( C) Diode Array Detector 25 28 nm, 8 Hz 6 28 nm, 16 Hz 2

Six aromatic acids were analyzed in this work; their structures are shown in Figure 1. Each of these compounds, as well as the formic acid mobile phase modifier, was purchased from Sigma Aldrich. Acetonitrile was purchased from Honeywell (Burdick and Jackson). Water was.2 µm filtered 18 MW from a Milli-Q system (Millipore). Results and Discussion The original separation of six aromatic acids was demonstrated on a 4.6 25 mm, 5 µm totally porous particle ZRBAX Eclipse Plus C18 column. This separation was accomplished in 36 utes with a imum resolution of 2.4, and is shown in Figure 2. Figure 2 also shows the same LC method transferred to a 2.1 5 mm, 1.9 µm superficially porous particle InfinityLab Poroshell 12 EC-C18 column. ZRBAX Eclipse Plus C18 and Poroshell 12 EC-C18 have similar bonded chemistries for highly correlated overall selectivity, so no changes to the method are needed. However, because the columns are different dimensions, the gradient, flow rate, and injection volume are geometrically scaled for the smaller column volume. Flow rate is also increased for the 1.9 µm Poroshell column to run at the optimal flow rate for this smaller particle. The resulting chromatogram is 12x faster, uses 96 % less mobile phase, 75 % less sample, and still maintains a imum resolution of 2.9. Protocatechuic acid 3,4-Dihydroxyphenylacetic acid (DPAC) 4-aobenzoic acid (PABA) CH CH 3 CH 3 3 Vanillic acid Syringic acid Salicylic acid Figure 1. Compounds of interest 8 6 4 2 35 3 25 2 15 1 5 5 1 15 2 25 5 1 15 2 25 NH 2 Agilent ZRBAX Eclipse Plus C18, 4.6 25 mm, 5 µm 1. ml/, 8 35 %B in 36 utes, 25 C, 28 nm Minimum resolution = 2.4 Agilent InfinityLab Poroshell 12 EC-C18, 2.1 5 mm, 1.9 µm.5 ml/, 8 35 %B in 3 utes, 25 C, 28 nm Minimum resolution = 2.9 Compared to 25 mm, 5 µm analysis: 12x faster 96 % less mobile phase used 75 % less sample injected Figure 2. A 25 mm, 5 μm Agilent ZRBAX analysis of aromatic acids is improved by transferring to a high-performance 5 mm, 1.9 μm Agilent InfinityLab Poroshell column; imum resolution is improved, while saving significant time, sample, solvent, and money. 3

The 1.9 µm Poroshell analysis generates 472 bar in pressure. This may be inhibitory for some analysts depending on their instrument pressure specifications. Within the Agilent Poroshell 12 family there are three particle size options: 1.9, 2.7, and 4 µm. These different particle sizes use the same bonded phases for easy method transferability. Figure 3 shows the same selectivity for all three particle sizes using this separation of aromatic acids; all method parameters are identical. As particle size increases, pressure decreases. However, this comes at the cost of reduced resolution and peak capacity with larger particle sizes. In this situation, an analyst should choose the column that best suits their needs, whether they are limited by the operating pressure of their existing instrumentation, or if they are looking for the best possible resolution. The benefit of using small superficially porous particles is that they offer high efficiency and resolution. This high performance can be used to run ultrafast analyses, if your LC system pressure limit allows. In Figure 4, the 1.9 µm Poroshell column was pushed to its limit. High temperature was used to decrease the mobile phase viscosity so that the flow rate could be pushed to 2.2 ml/, generating 1,15 bar. The gradient also was slightly adjusted from the previous methods to ensure the fastest possible separation from this column with this sample of aromatic acids. The result is that all six compounds separated in.35 utes with a imum resolution of 2.3. Compared to the 25 mm, 5 µm Eclipse Plus method, this analysis is 13x faster, and uses 98 % less mobile phase while maintaining the imum resolution. 35 3 25 2 15 1 5 35 3 25 2 15 1 5 35 3 25 2 15 1 5 35 3 25 2 15 1 5.5.1.15.2.25.3 Agilent InfinityLab Poroshell 12 EC-C18, 2.1 5 mm, 1.9 µm.5 ml/, 8 35 %B in 3 utes, 25 C, 28 nm Maximum pressure = 472 bar Minimum resolution = 2.9 Peak capacity = 58.5 1. 1.5 2. 2.5 Agilent InfinityLab Poroshell 12 EC-C18, 2.1 5 mm, 2.7 µm.5 ml/, 8 35 %B in 3 utes, 25 C, 28 nm Maximum pressure = 281 bar Minimum resolution = 2.1 Peak capacity = 52.5 1. 1.5 2. 2.5 Agilent InfinityLab Poroshell 12 EC-C18, 2.1 5 mm, 4 µm.5 ml/, 8 35 %B in 3 utes, 25 C, 28 nm Maximum pressure = 141 bar Minimum resolution = 1.8 Peak capacity = 43.5 1. 1.5 2. 2.5 Figure 3. Similar selectivity among Agilent InfinityLab Poroshell particle sizes allows analysts to choose their column configuration based on instrument pressure limits or method performance requirements without needing to do additional method development. Agilent InfinityLab Poroshell 12 EC-C18, 2.1 5 mm, 1.9 µm 2.2 ml/, 8 26 %B in.3 utes, 6 C, 28 nm Minimum resolution = 2.3 Compared to 25 mm 5 µm analysis: 13x faster 98 % less mobile phase used Figure 4. Additional time, solvent, and money can be saved by operating the highly perforg 5 mm, 1.9 μm Agilent InfinityLab Poroshell column near its pressure limit without compromising method performance. 4

Table 3 shows a summary and comparison of all chromatographic results. Table 3. Comparison of aromatic acid analyses with different LC columns. Column Agilent ZRBAX Eclipse Plus C18, 4.6 25 mm, 5 μm 2.1 5 mm, 1.9 μm 2.1 5 mm, 2.7 μm 2.1 5 mm, 4 μm 2.1 5 mm, 1.9 μm (ultrafast) Pressure (bar) Minimum resolution Conditional peak capacity (nc) Run time () Mobile phase consumption (ml) 193 2.4 88 36 riginal 5 μm analysis 36 riginal 5 μm analysis 472 2.9 58 3. 12x Faster than original 5 μm analysis 281 2.1 52 141 1.8 43 115 2.3 37.35 13x Faster than original 5 μm analysis 1.5 Uses 96 % less mobile phase than original 5 μm analysis.77 Uses 98 % less mobile phase than original 5 μm analysis Conclusions The highly efficient 1.9 μm Agilent InfinityLab Poroshell 12 column can be used to improve existing methods using traditional columns, such as a 5 µm Agilent ZRBAX Eclipse Plus C18. The Poroshell and ZRBAX families offer similar bonded phase chemistries so that methods are easily transferred, often requiring no additional method development. If the pressure generated by the 1.9 µm particle is too high for LC system limits, there are also Agilent Poroshell 12, 2.7 and 4 μm particles available that offer the same selectivities. However, when LC system pressure limits allow, the 1.9 µm Poroshell column can be pushed to accomplish an ultra-fast separation, which will save significant time, solvent, sample, and money compared to traditional LC columns. 5

References 1. Gratzfield-Hugsen, A.; Naegele, E. Maximizing efficiency using Agilent Poroshell 12 Columns, Agilent Technologies Application Note, publication number 599-562EN, 216. 2. Meyer, V. R. In Practical High Performance Liquid Chromatography. Fourth Edition, Wiley: 24; p. 34. 3. Transfer of Methods between Poroshell 12 EC-C18 and ZRBAX Eclipse Plus C18 Columns, Agilent Technologies Application Note, publication number 599-6588EN, 211. www.agilent.com/chem This information is subject to change without notice. Agilent Technologies, Inc., 216 Published in the USA, November 1, 216 5991-7518EN