Digital Panoramic X- Ray unit. Product Data

Similar documents
I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

X-Mind. Instinct for perfection

Digital panoramic X-ray for practical diagnostics

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Digital Dental X-ray. Midmark Animal Health Products

The professional for your diagnostics.

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Voltage nominal maximum for test. Inverse voltage. nominal maximum for test. Focal spots (IEC 60336:2005) small large

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

DENTAL Cone beam 3D X-RAY SYSTEM with

Electronic Control Devices The European Product Catalogue 2007

8000C Digital Panoramic and Cephalometric System. User s Guide

Electronic Control Devices The European Product Catalogue 2007

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

ProOne Digital X-ray Imaging Hardware Diagrams and System Requirements

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

CS D Panoramic Cephalometric. Innovation, in reach

X-ray Imaging Systems

Progeny Vantage Panoramic X-ray System

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

PLANMED SOPHIE MAMMOGRAPHY X-RAY UNIT TECHNICAL MANUAL /11 LAT LAT SIN DEX. kv kv. mas. mas CTL

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

X-ray Imaging Systems

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Essential points for X-ray technicians

Frequency Converter Fv

Drayton Digistat +2RF/+3RF

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

user's manual _19

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

In the previous presentation, we discussed how x-rays were discovered and how they are generated at the atomic level. Today we will begin the

ENGLISH. Planmeca ProMax 3D concept

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

3DLevelScanner II TECHNICAL DATA SHEET

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Pocket Tach 99 (PT99) Non-Contact Tachometer

Combi switchbox with integrated 3/2 way pilot valve

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Technical Data FLIR E40bx (incl. Wi-Fi)

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Technical Data Sheet. 3DLevelScanner

Datex-Ohmeda Critical Care Monitor

SEMTech Solutions. Leaders in Refurbished SEMs. SEMTech Solutions Windows 7 SOFTWARE CONTROL SYSTEM

Technical Data. FLIR T (incl. Wi-Fi)

PART 1 PRODUCT (GENERAL)...1.

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

KS-70. Catheterization Table GENERAL

T Substation Maintenance and Commissioning Test Equipment

HERZ-Thermal Actuators

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DICOM Correction Item

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound)

photoelectric highlights

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

COST EFFECTIVE FLAT PANEL DIGITAL RADIOGRAPHY UPGRADE SOLUTIONS

JB-70 Dental X-Ray System

Photovoltaic Solar Energy Unit EESFB

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DS 600. A contact free flux gate based current measurement sensor 600A rms

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Actuator for modulating control AME 435

T0118 T2118 T3118. Instruction Manual

Power Thyristor TS3 (SP) 3ph. Installation Guide

SCHMIDT ManualPress 300 Series Manual Presses with Process Monitoring

IFC 070 Technical Datasheet

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Operating instructions Optical distance sensor O1D100 O1D / / 2012

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Performance testing for Precision 500D Classical R/F System

Bitewing Radiography B.E. DIXON. B.D.S., M.Sc., D.P.D.S.

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

ClearView+ User Manual

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited

Rodenstock Photo Optics

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Transcription:

Digital Panoramic X- Ray unit Product Data Standard examination programs Standard panoramic: adult/child panoramic exam TMJ open/close mouth: 4 slices are taken in the same image (left/right condyle, open/close mouth). Condyles are examined in lateral projection Maxillary Sinus P-A: P one P-A projection, where both the maxillary sinuses are represented. In every program the compensation of spinal column is obtained by means of parameters modulation, optimized in function of the anatomic program. Optional examinations package Panoramic XP - extended Programs Half alf-panoramic panoramic: panoramic acquired only on the right or left side of the mouth. Improved orthogonality dentition: panoramic projection limited to the dentition, obtained with X-ray beam constantly perpendicular to the arch. It allows to reduce superimposition of adjacent teeth and to improve visualization of possible interproximal caries. Frontal dentition: panoramic limited to the frontal dentition (canine to canine), that allows to improve the detail definition on incisors. Low dose panoramic: panoramic with reduced angle of rotation to exclude the ascending ramus from the image. The result is a panoramic limited to the dentition area using a reduced patient dose. Bite-wing (right, left, double): the right or left projection allows the examination of lateral dentition (from eighth to fourth approximately), with optimized trajectory of rotating arm for a higher orthogonality of the x-ray beam on the adjacent teeth, to improve visualization of possible interproximal caries. Double Bite-wing projection performs both Bite-wing views in sequence, joining them on the same image. Product Data Rotograph Prime Rev. 0 Page 1 of 9

Image magnification Image magnification Geometric magnification (*) Magnification after software correction (**) Adult / Child standard 1 : 1.23 Panoramic (constant over dentition part) 1 : 1 TMJ open/closed mouth, 4 images 1 : 1.20 (nominal) 1 : 1 Sinus 1 : 1.22 (nominal) 1 : 1 (*) Note: the magnification factor is calculated in the centre of the focal layer, which is based on a shape of the mouth-ascending ramus complex, as defined in international literature. (**) Note: The declared image magnification value for digital images depends on the calibration of the specific SW used and is therefore valid after proper software calibration. Patient positioning Patient positioning is assured through multiple references: 2 temple clamps 5 types of positioning supports are included: standard with bite stick, reduced height with bite stick, for edentulous patients, for ATM and for Sinuses. Two laser pointers allow to locate the reference planes: mid-sagittal, Frankfurt Selection of dentition morphology through dedicated function on the virtual keyboard, without patient repositioning Pair of patient handles, covered with a special antibacterial paint that prevents the development of microorganisms thanks to the emission of silver ions Anatomic programs Patient type: 2 choices: adult, child Patient size: 3 choices: small, medium, large Arch shape: 3 choices: retracted, standard, protruded Product Data Rotograph Prime Rev. 0 Page 2 of 9

Tube-head features Inverter frequency 90 khz typical kv range 60 70 kvp, 2 kv step kv accuracy ± 8 % ma range 2 7.1 ma, according to R20 scale ma accuracy ± 10 % Nominal power 497 W (70 kvp - 7.1 ma) Duty cycle 1:16 Total filtration 2 mm Al eq. @ 70 kvp HVL (Half value layer) > 2.5 mm Al eq. @ 70 kvp Transformer insulation Oil bath Cooling By convection Leakage radiation at 1 m < 0.5 mgy/h @ 70 kvp - 7.1 ma - 3 s duty cycle 1/16 Tube-head maximum thermal capacity 310 kj (413 khu) X-ray shielding Lead free X-ray Tube Model D-058 Focal spot size 0.5 mm (EN 60336) Inherent filtration 1.0 mmal eq. Anode angle 12.5 Anode material Tungsten Nominal maximum voltage 70 kvp Filament max. current 3 A Filament max. voltage 3.6 V Anode thermal capacity 13 kj (17 khu) Maximum anode heat dissipation 300 W Exposure times Standard programs Panoramic 14.4 s adult / 13.3 s child TMJ Open/Close mouth 4 x 2.44 s (total 9.7 s) Maxillary sinus P-A 9.4 s Examinations package Panoramic XP - extended Programs Hemipanoramic 7.8 s adult / 7.3 s child Improved orthogonality dentition 11.9 s adult / child Frontal dentition 4.4 s adult / child Low dose panoramic 11.9 s adult / 10.8 s child Bite-wing 3.2 s right / left 6.3 s right and left Product Data Rotograph Prime Rev. 0 Page 3 of 9

Accessories Standard chin support with bite stick (standard) Reduced height chin support with bite stick (standard) Chin support for edentulous patients (standard) Reduced height support for Sinus (standard) Specific support for TMJ analyses (standard) 10 bites (standard) X-ray push button with extensible cable (standard) Disposable byte protective sleeves (optional) Onboard user interface 1 2 3 4 5 6 7 8 LEGEND: 1-2: Height adjustment of panoramic unit Up / Down pushbuttons 3: Laser centring device - On / Off pushbuttons 4: Light signalling Ready for X-rays / Cooling down / Axis reset (green led) 5: Light signalling X-rays in progress (yellow led) 6: Light signalling the computer connection status or error status (blue led) 7: Centring / Patient entry Pushbutton for: > Positioning the rotating arm to the initial position to start the exam > Repositioning of the rotating arm to the patient entrance position at the end of the exposure 8: Knob for manual opening/closing of the temple clamps Product Data Rotograph Prime Rev. 0 Page 4 of 9

Virtual control panel 12 11 10 9 8 7 1 6 2 3 4 5 LEGEND: 1: Exam selection on two different levels: exam family, exam type 2: Exam information: selected exam, exposure time, DAP value, exposure parameters 3: Patient selection: Adult / Child 4: Patient size selection: Small / Medium / Large 5: Dentition morphology selection: Retracted / Standard / Protruded 6: ma selection 7: kv selection 8: Function not in use 9: Test mode selection 10: Service menu selection 11: Unit status 12: Service messages bar Product Data Rotograph Prime Rev. 0 Page 5 of 9

Panoramic image sensor Technology: CCD sensor with Cesium Iodide (CsI) scintillator screen Sensor size: 146 x 6 mm Pixel size: 48 µm (96 µm in 2x2 binning mode) Image matrix: 1536 x 2805 pixels in 2x2 binning mode (standard panoramic) Sensor resolution: 10.4 lp/mm maximum theoretical 5.2 lp/mm with CTF 60% real (in 2x2 binning modality) Grey levels: 4096 (12 bits) in acquisition (A/D converter) Max useful image size: equivalent to a 15x30 cm film Image acquisition Rotograph Prime requires a Ethernet connection to the PC in order to acquire the digital images. Software QuickVision Rotograph Prime is equipped with QuickVision software for image acquisition, storage and processing (see dedicated product data for specific details). Software DAP meter (Dose-Area product) Irradiated dose is estimated by software according to the exam exposure factors. Reading accuracy: ±20% DAP value is displayed on the virtual control panel for each selected examination program. Product Data Rotograph Prime Rev. 0 Page 6 of 9

Mechanical features Source to image distance: 500 mm (19,7 ) Vertical column movement: 660 mm (33,5 ), motorized telescopic movement Weight: 62 kg (136,6 lb) complete unit, wall mounted version Total height max: 2180 mm (85,8 ) Room size: minimum 1200 x 1150 mm (47,2" x 45,3") recommended 1600 x 1500 mm (63 x 59 ) Type of installation: wall mounted Electrical features Power supply voltage: Frequency: Maximum line current: Power consumption: Line apparent resistance: 220-240 V / 110-120 V (±10%) single phase 50/60 Hz 3,5 A @ 230 V / 7 A @ 115 V 0,8 kva @ 230 V / 0,8 kva @ 115 V 0,5 Ω Environmental features Operating temperature +10 C +40 C Operating relative humidity 30% 75% Operating atmospheric pressure 630 hpa Transport and storage temperature -20 C +70 C Transport and storage relative humidity < 95 % non condensing Transport and storage atmospheric pressure 630 hpa Standards and Regulations 0051 CE symbol grants the product compliance to the European Directive for Medical Devices 93/42/EEC and its revised versions as a class IIB device Product Data Rotograph Prime Rev. 0 Page 7 of 9

Dimensions wall mounted version (all quotes in mm and inches) 797 (31.4") 1107 (43.6") 975 1635 (38.4" 64.4") 1524 2184 (60.0" 86.0") 953 (37.5") Product Data Rotograph Prime Rev. 0 Page 8 of 9

Dimensions wall mounted with support version (all quotes in mm and inches) 797 (31.4") 1107 (43.6") 975 1635 (38.4" 64.4") 1524 2184 (60.0" 86.0") 953 (37.5") Note: Products are continuously under review in the light of technical advancement. The actual specification may therefore be subject to improvement or modification without notice. VILLA SISTEMI MEDICALI s.p.a. 20090 BUCCINASCO (MI) ITALY, Via delle Azalee, 3 Tel. +39-02-488591, Fax +39-02-4881844 Company with Quality System certified by ISO 9001:2008 E N I S O 1 3 4 8 5 : 2 0 1 2 Product Data Rotograph Prime Rev. 0 Page 9 of 9