SM 3300 - Interface modules



Similar documents
ES Series 150 W DC POWER SUP PLIES

SM Series 3300 W DC POWER SUP PLIES

SM Se ries 6000 W DC POWER SUP PLIES DELTA ELEKTRONIKA B.V. Mod els Volt age range Cur rent range. Three phase input

SM Se ries 800 W DC POWER SUP PLY

SM Series 1500 Watts DC POWER SUP PLIES

High Power Programmable DC Power Supplies PVS Series

TROU BLE SHOOTING VIKING ALARM VALVES

ASCENT TM Integrated Shipment Management

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

MODEL 62000H-S SERIES

CA723, CA723C. Voltage Regulators Adjustable from 2V to 37V at Output Currents Up to 150mA without External Pass Transistors. Features.

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

1.44 kw Programmable DC Power Supplies XLN Series

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

DCS Series 1 kw, 1.2 kw, & 3 kw

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

MOTION COORDINATOR MC206X Quick Connection Guide

TO-PASS. TO-PASS -FAQ- Remote Monitoring. What is TO-PASS used for? What are the special functions of TO-PASS?

Current Monitoring Kit QUICK START GUIDE

IRS-8B. In stal la tion and Pro gram ming Man ual. Soft ware Ver Man ual N Rev. -

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Model: DC-A2IO Advanced HVAC Controller

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

Copyrights 2010 Victron Energy B.V. All Rights Reserved

SenseLink TM. End-Point Controller. Addendum

Multi-Range Programmable DC Power Supplies 9115 Series

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Multi-Range Programmable DC Power Supplies 9115 Series

Application/Connection Examples

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Temperature & Humidity SMS Alert Controller

Documentation. M-Bus 130-mbx

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

How To Use An Hm804X Series Of Power Supplies

MULTILINK 8 IN PUTS 8 OUTPUTS INTERFACE/PERIPHERAL ML-8

s!nus-elektrotechnikai bt. Industrial IT & Automation

SL Series AC and DC Electronic Loads

UN-436. In stal la tion and Pro gram ming Man ual. Soft ware Ver Man ual n Rev. A

Controller board and power supply for vivimat III systems

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

Bristol ControlWave Redundant Control

SMS GSM Alarm Messenger

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

MIDNITE SOLAR AND SOLAR WASHINGTON

10GBASE -LRM, 220m Reach GX LRMC

Current Monitoring Kit

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

X2 LR Optical Transponder, 10Km Reach

LSNJ...justice for all

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

NEW. EVEN MORE data acquisition and test stand automation

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

IRS-CB. In stal la tion and Pro gram ming Man ual. Soft ware Ver Man ual n Rev. A

M1000 Process Alarm Monitor

Temperature & Humidity SMS Alert Controller

Installation manual. Generator Paralleling Controller GPC multi-line C

Controlers. Controler

650W Single Output Power Supply

Ideal for high dynamic range measurements from compression to noise floor

ELECTRONIC CONTROL UNITS. Machine Management Systems. Description. EC-MMS-1012-H 10 inputs, 12 outputs meter-in systems controller 20

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

NIM High Voltage Power Supplies

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DRM compatible RF Tuner Unit DRT1

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Cables KEITHLEY (U.S. only) ACCESSORIES

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor User Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

Modbus Plus Adapter. EIG Model MP1, a Modbus Plus adapter for DMMS 300+ and Futura+ Monitors. User Manual and Reference Guide Version 1.

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

NTE923 & NTE923D Integrated Circuit Precision Voltage Regulator

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Research RF Sputtering Packages

SCADA and Monitoring for Solar Energy Plant

Power Supplies 3. SDN-P DIN Rail Series

LED BUILT-IN MODULES. LUGA Shop 2013 LED Modules COB for Retail Environments. LUGA SHOP 2013 HiCRI lm TO 5000 lm. LUGA SHOP 2013 HiCRI

Auto mo tive Cor po ra tion TC 237 TRANSFER CASE PARTS MAN UAL

MLC TM Maximum Productivity and Versatility for Control without Compromise!

10/100/1000BASE-T SFP Transceiver

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

Industrial Automation Training Academy. PLC, HMI & Drives Training Programs Duration: 6 Months (180 ~ 240 Hours)

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

Inwall 4 Input / 4 Output Module

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Starlink 9003T1 T1/E1 Dig i tal Trans mis sion Sys tem

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Remote Monitoring and REC 501 Control Unit Product Guide

PT-100. Use and pro gram ming man ual. Soft ware Ver d IST-PT Rev. -

Disturbance Recoder SPCR 8C27. Product Guide

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

USB Plus+ RFID Reader Setup Guide

LONGLINE 2km XFP Optical Transceiver

Transcription:

Vissersdijk 4 4301 ND Zierikzee The Netherlands Tel. +31 111 413656 Fax. +31 111 416919 www.deltapowersupplies.com DELTA ELEKTRONIKA B.V. SM 3300 - Interface modules Mod els Description INT MOD M/S Master/Slave interface INT MOD SIM Simulation interface INT MOD CON Isolated contacts interface INT MOD SER Multi-protocol serial interface INT MOD DIG Dig i tal I/O in ter face INT MOD ANA Isolated analog interface General Plug and play for the SM3300 se ries power sup plies Mul ti ple in ter faces pos si ble per power sup ply Iso lated from the out put volt age Work ing volt age 1000V Float ing with re spect to earth INT MOD M/S INT MOD SIM INT MOD CON Master Slave Interface Easy con trol of se ries or par al lel op er a tion. Mul ti ple power sup plies be have as one power sup ply. Mixed se ries and par al lel is also pos si ble. Simulation Interface High ac cu racy sim u la tion Sim u la tion of pho to vol taic, leadless sense com pen sa tion, in ter nal re sis tance and foldback cur rent Cus tom pro gram ma ble ta ble, for sim u la tion of com plex I-V curves Configurable trough web and GUI Isolated contacts 4 re lays with make-and-break contacts Ad di tional (float ing) In ter lock with 24V en able sys tem Pro gram ma ble via Ethernet INT MOD SER Serial controller interface Multi pro to col RS232, RS485, RS422, USB Web based con fig u ra tion Speeds up to 115.2 kbps Digital (user) I/O INT MOD DIG 8 in puts Logic high = 2.5... 30V, Logic low = 0V 8 Open Drain out puts 0-30V, max. 200mA Pro gram ma ble via Ethernet or se quences INT MOD ANA Analog controller interface High ac cu racy, low drift 16 bit AD and DA conversion Com pat i ble with other Delta Elektronika 15p an a log in ter faces Fac tory cal i brated for op ti mum ac cu racy

DELTA ELEKTRONIKA BV SM3300 INTERFACES Master Slave Interface Ap pli ca tions where more cur rent or volt age is re quired than one power sup ply can de liver. Ap pli ca tions where a sym met ri cal power sup ply is needed. Se ries Operation SM 18-220 SM 66-AR-110 SM 100-AR-75 SM 330-AR-22 SM 660-AR-11 Max. to tal voltage 1000V 1000V 1000V 1330V 1330V Max. de vices 8 Typ i cal ad di tional pro gram ming 4 ms time Pro gram ming Ca ble Mod u lar con nec tor ca ble 6P6C (1 ca ble sup plied with each in ter face) Max. ca ble length 0.5m Assembly Pluggable, SM3300 in ter face slots 1, 2, 3 or 4. See para graph Hard ware In stal la tion in this man ual. Note 1: max 1pcs INT MOD M/S per unit. Note 2: can not be com bined with INT MOD SIM. 70 g Page 1-2 SPECIFICATIONS 2013, rev. March 2015

SM3300 INTERFACES DELTA ELEKTRONIKA BV Simulation Interface Simulation of photovoltaic I-V curve Testing dynamic mppt effiency with EN 50530 standard Compensation for the voltage drop in the load leads without sense wires Custom I-V curve simulation trough custom table Simulation of internal resistance Simulation of foldback current limit Photovoltaic Simulation Re quired ref er ence pa ram e ters Open cir cuit volt age (V oc,stc ), Max i mum power point volt age (V mpp,stc ), Short cir cuit cur rent (I sc,stc ), Max i mum power point cur rent (I mpp,stc ), Tem per a ture at STC (T stc ), Irradiance at STC (G stc ), Tem per a ture co ef fi cient for the cur rent (Tc Isc ), Tem per a ture co ef fi cient for the volt age (Tc Voc ). Re quired panel pa ram e ters Tech nol ogy (csi or Thin Film), Tem per a ture of the pho to vol taic panel (T pv ), Irradiance on the pho to vol taic panel (G pv ). Re quired pa ram e ters for dy namic ef fi ciency test Irradiance high level (G high ), Irradiance low level (G low ), Start-up time, Ramp-up time, Dwell-high time, Ramp-down time, Dwell-low time, Num ber of rep e ti tions. Pro gram ming ac cu racy In ter nal Re sis tance SM 18-220 SM 66-AR-110 SM 100-AR-75 SM 330-AR-22 SM 660-AR-11 Max. configurable R i 13.5 mω 54.5 mω 115 mω 1.35 Ω 5.45 Ω Re sponse time R i Out put Volt age (load = 0W) Out put cur rent step Rise time (10% - 90%) Fall time (90% - 10%) 13.5 mω 16.5 V 20-200 A 3 ms 3 ms 54.5 mω 33 / 66 V 10-100 / 5-50 A 1.25 / 1.25 ms 1.25 / 1.25 ms 115 mω 50 / 100 V 6.6-66 / 3.3-33 A 1.35 Ω 165 / 330 V 2-20 / 1-10 A 5.45 Ω 330 / 660 V 1-10 / 0.5-5 A 2.5 / 2.25 ms 2.5 / 2.25 ms Leadless sense SM 18-220 SM 66-AR-110 SM 100-AR-75 SM 330-AR-22 SM 660-AR-11 Max. configurable R i 13.5 mω 54.5 mω 115 mω 1.35 Ω 5.45 Ω Re sponse time R i Out put Volt age (load = 0W) Out put cur rent step Rise time (10% - 90%) Fall time (90% - 10%) 13.5 mω 16.5 V 20-200 A 5.5 ms 5.5 ms 54.5 mω 33 / 66 V 10-100 / 5-50 A 4 / 4 ms 4 / 4 ms 115 mω 50 / 100 V 6.6-66 / 3.3-33 A 4.25 / 4 ms 4.25 / 4 ms 1.35 Ω 165 / 330 V 2-20 / 1-10 A 5 / 5.25 ms 5 / 5.25 ms 5.45 Ω 330 / 660 V 1-10 / 0.5-5 A 5 / 4.5 ms 5 / 4.5 ms Foldback current SM 18-220 SM 66-AR-110 SM 100-AR-75 SM 330-AR-22 SM 660-AR-11 Pa ram e ter range I fold 0 101% Fold time 0 100 s Assembly Pluggable, SM3300 in ter face slots 2, 3 or 4. See para graph Hard ware In stal la tion in this man ual. Note 1: can not be plugged in slot 1. Note 2: max 1pcs INT MOD SIM per unit. Note 3: can not be com bined with INT MOD ANA. 70 g 2013, rev. March 2015 SPECIFICATIONS Page 1-3

DELTA ELEKTRONIKA BV SM3300 INTERFACES Isolated Contacts Trigger an external safety alarm Interact in automated processes Switch the output On/Off with a remote 24Vdc signal Using a floating signal for triggering the Interlock function Re lay con tacts 1... 4 Con tact volt age Con tact current Max i mum switch ing ca pac ity Floating Interlock Open cir cuit voltage Floating Enable Nom i nal in put volt age In put volt age range In put impedance 60 V 2 A 60 W 5 V 24VDC 15-30VDC 12kOhm prog. con nec tors - in ter nal cir cuits prog. con nec tors - earth Mounting Pluggable, SM3300 in ter face slots 1, 2, 3 and 4. Max i mum 4 per unit. Programming connector Re lay 1 & 2, via a 6 pole push wire or so-called push in con nec tor. Re lay 3 & 4, via a 6 pole push wire / push in con nec tor. In ter lock and En able via a 3 pole push wire / push in con nec tor. For all 3 con nec tors there's a con tra header sup plied. Page 1-4 SPECIFICATIONS 2013, rev. March 2015

SM3300 INTERFACES DELTA ELEKTRONIKA BV Serial interface (multi-protocol) RS232 Programming Balanced RS422 Programming USB Programming Balanced RS485 Bi-directional Programming Communication speeds (bps) 2400, 4800, 9600, 19200, 38400, 57600, 115200 prog. con nec tors - in ter nal cir cuits prog. con nec tors - earth Mounting Pluggable, SM3300 in ter face slots 1, 2, 3 and 4. Max i mum 4 per unit. Programming connector RS422 & RS485 wires via push wire or so-called push in con nec tor (con tra header sup plied) RS232 via 9 pole D-con nec tor (fe male), USB socket type B. 2013, rev. March 2015 SPECIFICATIONS Page 1-5

DELTA ELEKTRONIKA BV SM3300 INTERFACES Digital User I/O Hardware triggering of sequences Interaction with other equipment Stand-alone automation Safety or Alarm indications Logic in puts 1... 8 In put range In put im ped ance Load cur rent +5V Logic out puts 1... 8 Out put type Out put im ped ance 2-30V Rin = 22kOhm 100mA Open Drain (True = 0V, False = open) 7 Ohm (max 30V/200mA) prog. con nec tors - in ter nal cir cuits prog. con nec tors - earth Mounting Pluggable, SM3300 in ter face slots 1, 2, 3 and 4. Max i mum 4 per unit. Programming connector User Out puts via 15 pole D-con nec tor High Den sity (fe male), User In puts via 15 pole D-con nec tor High Den sity (fe male). Page 1-6 SPECIFICATIONS 2013, rev. March 2015

SM3300 INTERFACES DELTA ELEKTRONIKA BV Isolated Analog Controller interface Analog programming of voltage and current Analog monitoring of voltage and current Remote monitoring of the status signals: OverTemp, Limit, PowerSink OverLoad Remote Shut down of the power output using a 5V signal Analog Programming CV CC Programming inputs in put range ac cu racy off set temp. coeff. off set in put im ped ance Monitoring output out put range ac cu racy off set temp. coeff. off set out put im ped ance 0-5 V / 0-10 V - 1... +1 mv (on 5V) 10 µv / C 10 MOhm 0-5 V / 0-10 V - 1... 1 mv (on 5V) 3 µv / C 2 Ohm / max. 4 ma 0-5 V / 0-10 V - 1... + 1 mv (on 5V) 10 µv / C 10 MOhm - 5 V to + 5 V / - 10 to + 10 V - 1... 1 mv (on 5V) 60 µv / C 2 Ohm / max. 4 ma Ref er ence volt age on prog. con nec tor V ref TC +12 V out put V o on prog. Con nec tor I max R o Status outputs CC - sta tus LIM- sta tus OT - sta tus PSOL - sta tus ACF - sta tus DCF - sta tus 5.114 V ± 15 mv (Ro = 2 Ohm, max. 4 ma) 20 ppm 12 V ± 0.2 V 0.2 A 5 Ohm CC - op er a tion 5 V = logic 1 (R o = 500 Ohm) CV or CC limit 5 V = logic 1 (R o = 500 Ohm) Over Tem per a ture 5 V = logic 1 (R o = 500 Ohm) Power Sink Over load 5 V = logic 1 (R o = 500 Ohm) AC - Fail 5 V = logic 1 (R o = 500 Ohm) DC - Fail 2 ) 5 V = logic 1 (R o = 500 Ohm) Remote ShutDown with + 5V, 1 ma or re lay con tact 2 ) out put volt age ± 5% be yond set point prog. con nec tor - in ter nal cir cuits prog. con nec tor - earth Mounting Pluggable, SM3300 in ter face slots 2, 3, 4. Note1: can not be plugged in slot1 Note2: max 1pcs MOD INT ANA per unit. Programming connector 15 pole D-con nec tor (fe male) 2013, rev. March 2015 SPECIFICATIONS Page 1-7