Installation instruction

Similar documents
SRP Pricelist 2015 Including VAT. Stoves for every home

556/586 NEW NEW. One step closer to the fire.

SPECIFICATION & INSTALLATION GUIDE FOR MASPORT LE4000 PROVINCIAL INSERT FIRE, NEW ZEALAND MODEL

Installation Instructions

ASX7-4-IOM-7 J

1 DESCRIPTION OF THE APPLIANCE

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Across America. Wood & Coal Brochure

A new range of clean burning multifuel stoves

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

FREESTANDING CLEAN AIR WOODBURNER

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Chimneys in Thatched Properties

INSTRUCTION FOR ASSEMBLY. 150x180 v Traditional sauna cabin

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

The Savannah Steel Series Wood Burning Stoves and Inserts

FIRES WITHOUT COMPROMISE EXCEPTIONAL FIRES JETMASTER INSET STOVE. Installation, Operating and Servicing Instructions JETMASTER MK6

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

version 1.0 Made by NARVI Oy Finland Kota Kuru 14 and 20 sauna heaters Installation, user and maintenance instructions

INFRARED QUARTZ WALL HEATER

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Accessory Manual Ventilation Section Model Comfort Circle

Cooktop Low-Profile Ventilation Hoods

plumbing products guide

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Stove-boiler for solid fuels KW Directions for use and assembling

Installation Instructions

Flue Installation. High Efficiency Condensing Boilers

SIM Spartherm Installation Modules NEW

Handcrafted with passion

39HQ Airovision Air Handling Units

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Window Installation Instructions

Excerpts from the Canadian National Building Code (NBC)

Bergen. NO Monterings- og bruksanvisning 2 GB Installation- and user manual 9 SE Installations- och bruksanvisning 15 FI Kättöohje 21

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Ducoterra Radiant Heating Panel Installation Manual

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

Isola Steel Gutters Strength and design for extreme climate!

Installation Instructions For Slider Casement Air Conditioners

Gas-Fired, Residential Storage Type Water Heaters

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

CELO5. User & Installation Manual.

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Installation, operation and maintenance manual TX 35A

Make sure oven is OFF. Never remove parts or touch the fan unless the oven is OFF.

Installation Instructions

Ravelli Camino Insert Wood Pellet Burning Heater. Wood Pellet Fire Installation Specifications. Safety testing of the

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Installation Instructions

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

THIS BOOK CONTAINS IMPORTANT INFORMATION. PLEASE KEEP IT IN A SAFE PLACE FOR FUTURE REFERENCE.

Assembly Instructions MDM Products Party Tent

A warm welcome home INSERTS AND CASSETTES

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Integral Kit Instructions

The growing popularity of Gas Fireplaces has created a demand for an ever increasing array of styles and sizes to fit every decor and budget.

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

2010 Residential Water Heater Replacement Check List

Energy Company Obligation (ECO): Technical Monitoring Questions

INSPIRE 40/45/55 INSTRUCTIONS OPERATING APPROVED FOR USE IN SMOKE CONTROL AREAS WHEN BURNING DRY WOOD LOGS OR AUTHORISED FUELS. Inspire 40 Inspire 45

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

Saferand easierinstallation

1. Geo Vertical 2. Geo Horizontal

HDA

Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Important Information

LAYING BLOCK AND BRICK

CHIMNEYS AND FIREPLACES

INSTALLATION & USER INSTRUCTIONS

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Cooling Capacity CFM in. w.c. (125 Pa)

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

San josé OWNER S MANUAL

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Installation Instructions

Installer s Guide 18-AH39D1-13

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

VACUUM CLEANER INSTRUCTION MANUAL

Commissioning of Heat Producing Appliances Burning Solid Fuel

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

HEAT WAVE DUCT KIT KIT #

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

Wood Heat The Safe Way

GENUINE PARTS INSTALLATION INSTRUCTIONS

Sun Windows General Information Sun New Construction Window Installation Instructions

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Transcription:

Installation instruction 51 52 52T 53 54 54T www.contura.eu

CERTIFICATE EC Declaration of conformity www.contura.eu Manufacturer name address Place of manufacture NIBE AB/NIBE STOVES Box 134, Skulptörvägen 10, SE-285 23 Markaryd Markaryd, Sweden PrODuct Product type type designation Standard Intended for use fuels Special conditions Stove fired by solid fuel Contura EN 13240 annex ZA Heating of living accommodation Wood logs None ce-marking contura 51, 52, 52t, 53, 54, 54t Issued 2006 nominal output 5 kw fuel type Wood logs flue gas temperature 275 C energy efficiency 79% emission of co 0,13% appendix Lighting and installation instructions Niklas Gunnarsson Business area manager NIBE STOVES Manufacturer's declaration The stove is approved by the Swedish National Testing and Research Institute, SP SITAC and fulfils the applicable rules for CE marking. Manufacture of the product has taken place in accordance with those documents that are the basis for the relevant type approval certification and the required manufacturing checks. ECOLABEL NORDIC 378 001 Contura is a Swan marked wood burning stove. NIBE was the first stove manufacturer in Sweden to commit to Swan marking stoves. The Swan mark is one aspect of our vision to be a company of the future, setting high quality standards regarding the environment. Certification number 378-001.

CONTENTS 51 A warm welcome to Contura. A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new stove. As a new owner of a Contura stove, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production. Read through these installation instructions carefully before installation. Read how to best light your stove in the lighting instructions. List of Contents General 52 Installation distance to walls and ceiling 53 Removing the loose components 55 Supply of combustion air 57 Adjusting and connecting C51 58 Adjusting and connecting C52/C52T 59 Adjusting and connecting C53 61 Adjusting and connecting C54/C54T 62 Connection to the chimney 64 NOTE: Report the installation of a stove to your local authority. The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed of the installation, as this will affect the routines for regular chimney-sweeping services. WARNING! The stove becomes very hot During operation, certain surfaces of the stove become very hot and can cause burn injuries if touched. Also, take heed of the strong heat radiated through the door glass. Placing flammable material closer than the safe distance indicated may cause a fire. Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury. 51

SE Eldningsinstruktion 2 NO Fyringsinstruksjon 5 SE Installationsanvisning DE Heizinstruktionen 2 9 GB Lighting Instructions 13 NO Installasjonsanvisning 17 DK Fyringsvejledning 17 DE Installationsanleitung 33 FI Lämmitysohjeet 21 GB Installation FR Instructions instruction d allumage 49 25 IT Istruzioni per l accensione 29 NL Stookinstructies 33 www.contura.eu www.contura.eu SE 1 www.contura.eu SE NO DE GB SE 1 HANDÖL In accordance with standards below marking was affixed: 2006 European Standard: EN 13240 SE Quality Certification, P-marked: Cert no 220316 NO Standard NS 3059: SINTEF 110-0257 DE and A Standard DINplus and Art 15a B-VG: RRF-40 07 1261 Type: H51/H52/H52T Nominal Output: 5 kw Fuel: Wood Minimun draught: 12 Pa Flue gas temerature: 275 C Energy efficiency: 79% Emission of CO in cumbustion products: 0,13% Distance to cumbustible wall (mm): Behind 1 Beside 0 Corner 1 Production number: Follow the installation instructions. Use only recomended fuels NIBE AB Box 134 SE-285 23 MARKARYD SWEDEN Type: -series Production no. 7090300236 NIBE AB SE-85 21 Markaryd Sweden GB 52 GENERAL Installationsanvisning Eldningsinstruktion Installationsanvisning Installationsanvisning 2 Installasjonsanvisning 17 Installationsanleitung 33 Installation instruction 49 General This manual contains instructions about how the Contura series must be assembled and installed. C 30 51 52 52T 53 54 54T 51 52 52T 53 54 54T Building application Before installing a stove or erecting a chimney it is necessary for you to apply for planning permission from your local authority. Ask your local authority for advice regarding building regulations and the application. To guarantee the function and safety of the stove we recommend that it is installed by a professional. Our Contura agents can recommend a suitable installer. Instructions for lighting and use are also supplied with the stove. Read them carefully and keep them safe for future use. The stove meets with the requirements which allow it to be connected to a chimney with gas temperatures of 3 C, the external connection diameter is Ø1 mm. Supply air from the open air should be used as combustion air. Technical data Output 3-7 kw Nominal output 5 kw Efficiency level 79% Model 51 52 52T 53 54 54T Weight (kg) 128 135 172 143 149 190 Width (mm) 495 495 495 5 5 5 Depth (mm) 420 420 420 455 455 455 Height (mm) 825 825 875 825 825 875 The connection s external diameter is Ø1 mm. Type approved in accordance with: European standard EN-13240 Swedish environmental and quality marking, P-marking cert. no. 22 03 16 (N) NS 3059, Cert.nr SINTEF 110-0257 (DE/A) DINplus, Art. 15a B-VG RRF-40 07 1261 Structural support Check that the wood joists are strong enough to bear the weight of the stove and chimney. The stove and chimney can usually be placed on a normal wooden joist in a single occupancy house if the total weight does not exceed 400 kg. Hearth plate To protect the floor from any embers the stove must be placed on a hearth plate. If the floor under the stove is flammable, it must be protected by a non-flammable material which covers at least 300 mm to the front and 100 mm on each side. The hearth plate can consist of natural stone, concrete or 0.7 mm metal. As an accessory, the hearth plate is available in painted steel. Chimney The stove requires a draft in the chimney of at least 12 Pa. The draught is affected both by the length and area of the chimney, and by how well sealed it is. Minimum recommended chimney length is 3.5 m and a suitable cross section area is 1-200 cm² (140-160 mm in diameter). Carefully check that the chimney is sealed and that there is no leakage around soot hatches and flue connections. Maximum chimney weight loading on the stove 120 kg. Note that a flue with sharp bends and horizontal routing reduces the draught in the chimney. Maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m. It must be possible to sweep the full length of the flue and the soot hatches must be easily accessible. Löstagbart Removable handtag handle Eldstadsbeklädnad Fire-box surround Brasbegränsare Log guard Asklåda Ash-pan Grate Rosterreglage shuttle Förbränningsluftsreglage Air supply control Type Typskylt plate 52 HANDÖL

Installation distance to walls and ceiling INSTALLATION DISTANCE 53 Combustible roof C51, C52 and C52T Position the stove on a hearth plate and check that the installation distances given in the diagrams are met. The minimum distance between the stove opening and combustible parts of the building or décor must be at least 1 m. 2000 520 495 Ø1 135 420 When top connecting a steel flue please refer to the relevant manufacturer s installation instructions. Observe the safety distances to combustible material that steel flues require. A = height from floor to top flue connection, Ø1 B = height from floor to c/c smoke outlet rear, Ø1 D 20 C = D = distance from back to c/c air inlet, Ø64 distance from back to smoke outlet rear, Ø1 295 A 825 B 705 C 65 Combustible wall 1 Permitted area for combustible parts of the building 400 300 200 100 Combustible wall 735 390 380 280 180 80 1 280 0 840 745 Fire-retardant wall of brick or concrete 290 Fire-retardant wall of brick or concrete 635 180 700 200* 445* *To prevent the discolouring of painted fire walls, we recommend a side distance the same as for the combustible wall. 53

54 INSTALLATION DISTANCE Installation distance to walls and ceiling Combustible roof C53, C54 and C54T Position the stove on a hearth plate and check that the installation distances given in the diagrams are met. The minimum distance between the stove opening and combustible parts of the building or décor must be at least 1 m. 2000 5 Ø 1 165 455 When top connecting a steel flue please refer to the relevant manufacturer s installation instructions. Observe the safety distances to combustible material that steel flues require. A = height from floor to top flue connection, Ø1 D 55 B = C = height from floor to c/c smoke outlet rear, Ø1 distance from back to top flue (c/c), Ø64 v A 825 B 705 D = distance from back to smoke outlet rear, Ø1 295 C 100 Combustible wall 1 Permitted area for combustible parts of the building 400 300 200 100 Combustible wall 695 3 0 400 300 200 100 1 315 470 785 745 Fire-retardant wall of brick or concrete Fire-retardant wall of brick or concrete 215, 1** 245, 3** 590, 695** 635, 785** 200* 475* * To prevent the discolouring of painted fire walls, we recommend a side distance the same as for the combustible wall. ** Minimum installation distance when using Contura base plate, applies when combustion air is obtained from the room and when connecting outdoor air through the floor. If outdoor air is NOT to be connected through the floor, the stove can be placed mm from fire walls if Nibe s tear-drop shaped base plate is used. 54

Removing the loose components REMOVING 55 Fire bars Lift the fire bars straight up, clean the ash from the guide groove in the stove base plate before repositioning it in position. Fire box surround When sweeping, the smoke baffle must be lifted out, this can be done when one side has been dismantled. Smoke baffle 55

56 REMOVING Stove base plate The stove base plate is lifted out when all the cladding has been removed. Fixed or removable handle The stove handle is fitted on delivery. To make the handle removable, replace the screw for the lock hook with the shorter screw supplied. 56

Supply of combustion air COMBUSTION AIR 57 Combustion air can be provided directly via a duct from outside, or indirectly via a vent in the outer wall of the room where the stove is to be placed. The amount of combustion air used for combustion is approximately 25 m 3 /h. Some installation alternatives are shown to the right. On certain models, C54 and C54T, when supply air is retrieved via walls behind, there is a knock out for inserting the combustion air hose, see figure below. HK The air duct connection on the stove has an external diameter of Ø64 mm. In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor (plastic). It is important that the lead-in between the pipe and the wall (or floor) is sealed using jointing compound. When duct routing for further than 1 m the pipe diameter must be increased to 100 mm and a correspondingly larger wall vent must be selected. HK A 1 m length of condensation insulated ducting for combustion air is available as an accessory. Cover for C51, C52, C52T and 53 Ducting to cover the outdoor air connection hose is available (accessory). The duct can be installed after the stove is installed. Knock out on C54 and C54T To insert the combustion air hose, the knockout in the base is tapped out using a hammer, remember to protect the floor. HK 30 mm HK 57

58 ADJUSTING AND CONNECTING Adjusting and connecting Contura 51 Preparations before rear connection The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around. Dismantle the cladding as instructed previously, see page 55. Tap out the knock out in the stove s back panel, remember to protect the floor. Then unscrew both the connector and the cover. Switch places and reinstall the screws. Adjusting the stove Position the stove on the hearth plate. Uninstall the rear sections of the legs. Adjust the height of the four adjustable feet until the stove is horizontal. When the rear sections have been reinstalled, cover the screws with the plastic plugs supplied. 58

Adjusting and connecting ADJUSTING AND CONNECTING 59 Contura 52 / 52T Preparations before rear connection The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around. Dismantle the cladding as instructed previously, see page 55. Tap out the knock out in the stove s back panel, remember to protect the floor. Then unscrew both the connector and the cover. Switch places and reinstall the screws. Adjusting the stove Position the stove on the hearth plate. Uninstall the inner covers of the legs. Adjust the height of the four adjustable feet until the stove is horizontal. When the inner sections have been reinstalled, cover the screws with the plastic plugs supplied. 59

60 ADJUSTING AND CONNECTING Soapstone installation Contura 52T Handle soapstone with care, the edges are susceptible to damage. Soapstone is most easily cleaned using a cloth dampened with acetone. Remove the upper securing plate. Position with the decorative groove downward so that the turned up edge holds the soapstone in place. Install and secure the upper securing plate so that panel edge locks the soapstone. Do the same on the opposite side and then position the soapstone cap. When connecting from behind, position the cover provided over the hole for the top connection. A hotplate is available as an accessory for installation in the hole in the top plate. Continue with the section Connecting to the chimney on page 64. 60

Adjusting and connecting ADJUSTING AND CONNECTING 61 Contura 53 Preparations before rear connection The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around. Dismantle the cladding as instructed previously, see page 55. Tap out the knock out in the stove s back panel, remember to protect the floor. Then unscrew both the connector and the cover. Switch places and reinstall the screws. Adjusting the stove Position the stove on the hearth plate. Uninstall the rear sections of the legs. Adjust the height of the four adjustable feet until the stove is horizontal. When the rear sections have been reinstalled, cover the screws with the plastic plugs supplied. Continue with the section Connecting to the chimney on page 64. 61

62 ADJUSTING AND CONNECTING Adjusting and connecting Contura 54 / 54T Preparations before rear connection C54 The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around. Dismantle the cladding as instructed previously, see page 55. Tap out the knock out in the stove s back panel, remember to protect the floor. Then unscrew both the connector and the cover. Switch places and reinstall the screws. Preparations before rear connection C54T The stove is prepared for top connection on delivery. When connecting from the rear, the cover and connection must be swapped around. Unscrew both the upper screws and lift off the back. Tap out the knock out in the stove s back panel, tap from the inside of the back, remember to protect the floor. Then unscrew both the connector and the cover. Switch places and reinstall the back. 62

ADJUSTING AND CONNECTING 63 Adjusting the stove Position the stove on the hearth plate. Unscrew the cover plate. Twist the cover plate as indicated by the arrow. Adjust the adjustable feet until the stove is horizontal and then reinstall the cover plate. Soapstone installation C54T Handle soapstone with care, the edges are susceptible to damage. Soapstone is most easily cleaned using a cloth dampened with acetone. Remove the upper securing plate. Position with the decorative groove downward in the lower soapstone holder so that the turned up edge holds the soapstone in place. Install and secure the upper securing plate so that panel edge locks the soapstone. Do the same on the opposite side and then position the soapstone cap. When connecting from behind, position the cover provided over the hole for the top connection. A hotplate is available as an accessory for installation in the hole in the top plate. Continue with the section Connecting to the chimney on page 64. 63

64 CONNECTION THE CHIMNEY Connection to the chimney After the stove has been adjusted and positioned according to the installation distances, connection to the chimney is carried out. Select one of the following alternatives. Important! Maximum chimney weight loading on the stove 120 kg. Top connection to the steel flue Press the start pipe onto the connection, continue the chimney installation according to the chimney installation instructions. Rearwards to a masonry chimney Connection to a masonry chimney can be the back or the top of the stove. Mark out centre for making a hole in the wall to the flue. Check that the connection height in the chimney breast corresponds to the height of the connection pipe from the stove. Cut a hole approximately 180 mm in diameter. Then cement in a wall connector with fire proof mortar (not supplied). Let the mortar dry before the stove is connected to the chimney. LEK Install the connection pipe on the connection. Make sure that the gasket does not work loose from its position. Caulk between the connection pipe and the connector in the wall using caulking rope. If further sealing material is required, heat-resistant sealant may be used. 64 811100 IAV SE-EX C-2 2012-10-08 NIBE AB Box 134 SE-285 23 Markaryd Sweden www.contura.eu Contura reserves the right to change colours, materials, dimensions and models at any time without special notice. Your dealer can give you the most up to date information. Stoves shown in brochures may have optional extras.