CTB16PCg3 User Manual

Similar documents
mdm-mp3 minidirector with MP3 Player

RS485 Adapters. User Manual October 26, 2008 V1.02 Copyright Light O Rama, Inc. 2006, 2007, 2008 SC485 USB485B USB485 USB485-ISO

3.5 EXTERNAL NETWORK HDD. User s Manual

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Animated Lighting Software Overview

Ethernet Radio Configuration Guide

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

RN-XV-RD2 Evaluation Board

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

=============================== WARNING

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

Application/Connection Examples

Application & Quick-Start Guide

User Manual. EtherUSB

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)


Honeywell Internet Connection Module

How to read this guide

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Transmitter Interface Program

PM1122 INT DIGITAL INTERFACE REMOTE

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

CM500 High Speed Cable Modem User Manual

SAFEPATH 4 Telephone Zone Controller

Getting Started. rp5800, rp5700 and rp3000 Models

Innovative Electronics for a Changing World INDEX

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

P-660HNU-Tx. Wireless N ADSL2+ 4-port Gateway DEFAULT LOGIN DETAILS. Firmware v1.02 Edition 1, 11/2011. IP Address:

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

CM400 High Speed Cable Modem User Manual

Hardware Overview. Ooma Linx devices These are installed around the office and are used to connect phones and other devices to your Ooma Office system

Creating a Project with PSoC Designer

INDEX. Trademarks All name and product s trademarks mentioned below are the property of their respective companies.

STIM202 Evaluation Kit

Dash 8Xe / Dash 8X Data Acquisition Recorder

Supplemental User Guide

Chapter 1 Installing the Gateway

UPS Network Interface. Quick InstallationGuide

GV- RK1352 Card Reader

Paragon Explorer Lite Communication Software

Software User Guide UG-461

In-System Programmer USER MANUAL RN-ISP-UM RN-WIFLYCR-UM

Configure Inverter output for two utility settings, (1)120V/60Hz, (2)220V/50Hz

Troubleshooting and Diagnostics

Cart Interface Installation & Control Board Manual for M38 XP and RX Carts and Legacy M39 Carts

3.5 Mobile LAN Disk. User Guide

WinLIN Setup and Operation:

Phaser 3635MFP Software Upgrade Process

MAINTENANCE & TROUBLESHOOTING

Installation and User Guide

Using GIGABYTE Notebook for the First Time

Select Correct USB Driver

RFID Logger Software User Manual Rev 1.0

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

DVR-4TL/8TL/16TL Setup Guide

DUKANE Intelligent Assembly Solutions

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

SecureLinx Spider Duo Quick Start Guide

LiteKeeper 4 & 8 Programming Guide and User Manual

Quick Start Guide. DVR DS-7200HWI-SH Series DVR. First Choice For Security Professionals

User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600

User Manual. EtherUSB

Guide to programming a Rako wireless module system using Rasoft

Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

IN THIS GUIDE YOU WILL LEARN HOW TO GET YOUR WIFI CABLE MODEM GOING IN NO TIME

Using GIGABYTE Notebook for the First Time

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version

Connecting your Omega/BetaPAT PLUS to a PC via a USB

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

EGCP-3 LS Revision L. Explanation of Software Changes Made for the EGCP-3 LS Control. Application Note 51294

MFC7840W Windows Network Connection Repair Instructions

Chapter 5 Cubix XP4 Blade Server

SSD Firmware Update Utility Guide

RIU-IP Remote IP Interface User Guide

MANUAL PC1000R

PRORAE REMOTE HOST CONTROLLER: COMMUNICATION TROUBLESHOOTING GUIDE

Windows XP.. ELITE Firmware Update procedures.. v1.41

Section 5: Installing the Print Driver

Alber Training and Education Product Tutorial. Battery Monitor Data Manager Software (BMDM)

Now your IviumSoft has been upgraded. After this proceed to upgrade the firmware of your instrument.

How do I configure the wireless printer using a USB or Ethernet cable and install the printer driver in Windows?

PN L, Revision B, October Epic 950 TM. Master Programmer User s Guide

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

VOICE RECORDING SYSTEM ISDN PRI / BRI

Installation and Setup Guides

Maintaining the Content Server

Warnings: This manual is intended to guide a technicians or customers who would like to repair DBL's

Zebra GC420t User Guide VIF-NA-BG-125, V3.0

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

Installing the Gerber P2C Plotter USB Driver

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Win 7 - STIMA CLS / CMP Driver Installation Quick Guide

Transcription:

Table of Contents Light- -Rama g3 User Manual Introduction... 3 What s in the Box... 5 Lighting Curves... 5 g3 with Heat Sinks... 7 Configuring and Testing... 8 Fuses... 8 Voltage Selection Jumper(s)... 8 Reset / Normal Operation Jumper... 9 Connecting Controller-to-PC Data Cable... 9 Auxiliary Display & Inputs Header... 11 Assigning a Unit ID (and DMX address)... 12 Configuring Lighting Curves... 14 Setting Multiple Channels in a Group... 17 Setting Individual Channels... 17 Example... 17 Testing the... 19 Designing and Playing a Sequence... 20 Status LED... 20 AutoConfigure fails to find COM port... 21 Hardware Utility Refresh Fails... 22 Updating Controller Firmware... 22 Specifications... 24 16 Channel Lighting Controller Generation 3 User Manual October 14, 2011 V3.01 Copyright Light O Rama, Inc. 2007-2011

Introduction PlanetChristmas and Light-O-Rama (LOR) are proud to bring you the g3. This full function controller was designed with the Christmas lighting enthusiast in mind. It is our most economical controller that sacrifices nothing in terms of the lighting effects. Whether you choose the Ready-To- Go model or one with some manual assembly labor, you will have a full function controller in a weather resistant plastic box. The is one of the components in the Hobbyist line of Light-O-Rama (LOR) products. It was designed for residential displays. It is a microprocessor based, intelligent controller that can perform a number of lighting effects including dimming, fading, shimmering and twinkling. It can be daisy-chained with any mix of LOR controllers up to the maximum of 240 controllers. The must be used with the LOR Windows Showtime Software Suite. This software allows you to configure and test this controller, design your sequences (sequences are lighting control command sets), arrange your sequences into shows and to schedule and play your shows. To allow your PC to communicate with this controller, you will need one of Light O Rama s RS485 adapters. When you purchase the Generic Starter Package, you get the LOR Showtime Software, a 10 Cat5e network cable and you will be given a choice of two types of USB RS485 adapters or a serial port RS485 adapter. Choose the adapter appropriate for your PC/laptop. The RS485 adapter will allow you to connect your PC/laptop via the Cat5e cable to your lighting controller. This controller is designed to control incandescent and line voltage LED light strings. It operates on 120 VAC (a 240 VAC model is available), 50/60 Hz. It can handle up to 30 amps with the factory heat sinks.. The 30 amp configuration can control approximately 9,000 incandescent mini-lights. This controller includes ghost loads which drain off charge to prevent low brightness LED glow when LEDs should be off. This controller uses higher reliability triacs (25 amp instead of 16 amp.) These are more tolerant of overloads and even survive some direct short circuit situations. This controller provides greater accessory power than previous LOR controllers. This additional power will be used by future accessories. The g3 firmware included with this controller has individual channel lighting curves for smooth, glitchfree dimming and effects with LED lighting. This firmware also increases the number of brightness steps from 250 to 1000 for smoother fading with LEDs. As with all LOR controllers, this controller is field firmware upgradeable so you are guaranteed compatibility with future LOR hardware and software products. 3 4

What s in the Box Included is a fully built and tested lighting controller and this user manual. The latest version of this manual is also available at www.lightorama.com Support g3 RTG User Manual. The voltage selection jumpers are already set and the Normal Operation Jumper is in place. It has been assigned Unit ID 01 at the factory. The process of changing the unit ID is described later in this manual. Caution: This product requires connection to 120/240 volt AC power. The board has many exposed line voltage connections that are dangerous. Be extremely careful if operating the controller with the box opened during testing. Lighting Curves The g3 firmware supports lighting curves. These are used to allow different types of lights to behave similarly when dimming. LEDs tend to go from off to full brightness over a much narrower range of voltages than incandescent lights. This means that a fade going from 0 to 100% voltage with an incandescent light will not produce the same results with LED lights. The LED lights will come on later and reach full brightness sooner than incandescent lights. There is a built-in Standard curve for incandescent lights which behaves as a simple, linear 0 to 100% voltage provider. This is the behavior seen with previous versions of the firmware and most DMX dimmer packs. There is a built-in On/Off curve. This on/off curve is used on a channel where the connected devices do not tolerate dimming, for example, the air blower motors in inflatables. Setting a channel configured for on/off operation to any intensity 50% or greater results in 100% intensity or on. Intensities below 50% result in the channel being off. Finally, a LED curve is provided which is the average for various LED colors and dimmable power supply configurations. This curve is provided with the software, so if you choose to change it you can recover the original. It is custom curve 1. The g3 firmware accepts up to eight downloaded, custom curves. Each channel is configured with its own curve from the ten possible curves the controller may have available. The default location for curve files is Light-O-Rama\DimmingCurves The curve file names are LOR-Curve01.ldc through LOR-Curve08.ldc. A curve file is a list of comma delimited numbers with as many numbers per line as you like. Text on a line preceded by a # is treated as a comment. 5 6

There are 1024 numbers in a curve file. The first number represents off and the last full brightness. A number in the curve file is a value between 0 and 1023. The curve files map into the LOR brightness world for which LOR will provide a conversion utility. g3 with Heat Sinks Configuring and Testing Fuses There are two white fuses located at the left and right bottom of the controller circuit board. The left fuse protects channels 1-8. The right fuse protects channel 9-16. The right fuse also supplies power to the controller electronics. The fuses are 15 amp, fast acting ceramic. Voltage Selection Jumper(s) For 120 VAC operation, both jumpers should be installed on the header that is to the lower right of the transformer. See following picture: 120 VAC SELECTION JUMPERS 30 amp 120 vac g3 Lighting Controller *** 240 VAC operation *** For 240 VAC operation, only one jumper on the center two pins of this header must be installed AND the ghost loads must either not be present or of the correct value. Boards configured for 240VAC operation will be marked with a sticker specifying 240VAC operation allowed. 7 8

Reset / Normal Operation Jumper There is a jumper on header JP3. JP3 is the smaller, 6-pin header to the lower left of the network connection jacks. Pin 1 of this jumper is furthest from the network jacks. For normal operation, the jumper is installed between pins 4 & 5 as shown in the following picture: To reset the controller, power it off, move this jumper to pins 5 & 6 (one pin right) and power the controller on. The status LED will fast blink during reset. Once you see this, power the board off and move the jumper back to pins 4 & 5. Reset resets everything. The Unit ID reverts to 01, all channels are set to the Standard dimming curve and downloaded dimming curves are deleted. Connecting Controller-to-PC Data Cable If you have not installed your RS485 adapter, do it now. If you have an SC485 (PC serial port adapter, shown on the left below), you need only plug it into an available PC 9-pin serial port. The cable from a serial adapter to the first controller is limited to 100 or less. If you have one of the USB adapters (shown center and right above), follow the installation instructions that came with the adapter. If you are using telephone cable to connect your controller to the RS485 adapter, plug one end of the phone cable into the adapter and the other end of the cable into the PHONE CABLE IN jack as indicated in the picture below. If you are using Cat5e LAN cable to connect your controller to the RS485 adapter, plug one end of the data cable into the adapter and the other end into either of the CAT5E CABLE IN or OUT jacks shown in the previous picture. 9 10

Auxiliary Display & Inputs Header This 20-pin header located on the upper left of the controller circuit board provides for an auxiliary display card and interactive trigger inputs. Both the Display Card and an Input Header will be available soon. The Display Card allows the Unit ID to be set without a PC, display controller status and allows testing of the controller. With the Display Card, the Unit ID can be set independently from the DMX address. 20-Pin Header Diagram: Sample input trigger connection XMIT JP4 GND LED INPUT1 TX INPUT3 RX INPUT2 IRQ_N +3.3V STB +5V SCK +9V SDO N/C IR SDI N/C N/C connections should be made to pins other than GND, INPUTn or +9V. Assigning a Unit ID (and DMX address) If you have not installed the Light O Rama Windows Showtime Software, do it now. The board will need to be powered at this point BE VERY CAREFUL there are dangerous voltages present on the exposed circuit board. Take appropriate precautions with children and pets. Plug the power cord(s) into AC power. The LED on the upper left will blink about twice/second. This means that the board has booted and is waiting for the PC to talk to it. Connect the controller to your PC see the Connecting Controller-To-Pc Data Cable section. Start the Hardware Utility click start All Programs LightORama Light-O-Rama Control Panel. There will be a light bulb with a red halo on the right side of the task bar at the bottom of the screen. Right-click the light bulb and select Hardware Utility from the menu. Make sure the LOR Control tab is selected. You will see the following window: The diagram above shows a sample connection for one of the trigger inputs. Do not apply voltages to any pins. The trigger inputs must be simple switch closures. The +9vdc pin may be used to power accessories like motion detection switches. No 11 12

3. Click the Change Unit ID button to set your unit ID. You will see a Unit ID Changed box click OK. The DMX address is set to (Unit ID 1) * 16 + 1. Your is ready for testing. Click the Auto Configure button in the Setup Comm Port section. The Hardware Utility will search for the COM port that your RS485 adapter is plugged into and select it. When assigning a unit ID, only one controller should be plugged into the RS485 adapter on the PC. Be sure you do not have more than one controller connected. Steps to set/change unit ID: 1. In the Change Existing ID section, use the Old Unit ID drop-down menu to select Any Unit, then click OK in the warning box for changing all unit IDs, there should only be one unit attached. 2. Use the New Unit ID drop down menu to select 01 or whatever Unit ID you want to assign to the attached controller. Configuring Lighting Curves Each channel on the controller is assigned a lighting curve. Initially, all channels are configured with the Standard curve. See the Lighting Curves section for more information on what curves are and which curves come with the controller. The Hardware Utility is used to read current curve information from the controller, download new curves to the controller and associate curves with the output channels. Start the Hardware Utility (see the Assigning a Unit ID section). In the Max Units section of the Hardware Utility window, click the Change button. Move the slider in the Change Maximum Units box so that the Max Units is set to 10 (or the maximum number of controllers you have configured.) This will limit the search for controllers to the first 10 unit IDs, otherwise 240 controllers would be searched for taking a long time. Click the Save button. Click the Refresh button to find your controller(s). Select a controller from the drop down menu to the right of the Refresh button. Then click the Configure button at the bottom of the window. You will see this window: 13 14

Click the Advanced Configuration button on the lower right. The Hardware Utility will read the current curve information from the controller, find the curve files on your PC (if any) and display this window: This initial configuration shows all channels configured for the Standard curve, also shown is one custom curve file loaded into the controller and two custom curve files located on the PC disk. The controller is a 16 channel controller so channels 17 through 32 are grayed out. To transfer a new curve from the PC to the controller or update a existing curve on the controller from the PC, click the appropriate Load nn button. The curve file on disk will be transferred to the controller. The vertical progress bar to the right of the Load nn buttons will indicate percent transferred to controller. The Read Unit s Config button will ask the controller for its channel to curve file mapping and show which custom curves are loaded into the controller. 15 16

Setting Multiple Channels in a Group You can change the curve association for multiple channels in channel group 1-8 or channel group 9-16 using the All row above that channel group. If you check the All box, then all channels in that 8 channel group will be affected. If you only want to change some of the channels in the group, check their individual check boxes. Then use the drop down menu in the All row to select the curve for the checked channels and click the Set Checked button. Those channels will be changed to the curve selected. Finally, click the Update Unit s Config button to send the new curve configuration to the controller. Setting Individual Channels Do not check the All box, but do check the boxes to the left of the channels for which you want to change curves. Then use the drop down menu next to the checked box to select the curve you want for that channel. Finally, click the Update Unit s Config button to send the new curve configuration to the controller. Note: If you configure a channel for a curve that does not exist in the controller, the Standard curve will be used. drop-down menus have been used to select the desired curves: Clicking the Update Unit s Config button sends the new curve configuration to the controller. The controller is updated and the text in the upper right box changes to indicate this: Example In the following example, channels 3 and 4 are being set to custom curve 01 and channels 15 and 16 are being set as On/Off only channels. The check boxes for channels 3, 4, 15 and 16 are checked and the 17 18

The Test Unit s Operation section of the screen should be active. Plug some lights into your controller and use the sliders and buttons in this section to test your controller. Testing the In the Max Units section of the Hardware Utility window, click the Change button. Move the slider in the Change Maximum Units box so that the Max Units is set to 10 (or the maximum number of controllers you have configured.) This will limit the search for controllers to the first 10 unit IDs, otherwise 240 controllers would be searched for taking a long time. Click the Save button. In the Select Unit to Configure..Download..Test section of the Hardware Utility screen, click the Refresh button to locate your attached controller(s). Your controller(s) will appear in the drop down menu to the right of the Refresh Button. Select the controller you want to test. Designing and Playing a Sequence Lighting commands for your shows are called Sequences and are designed and implemented using the Sequence Editor Windows software. Stop the Hardware Utility. You will not be able to command your controller from the Sequence Editor if the Hardware Utility is running. Only one program may use the RS485 adapter at a time to talk to lighting controllers. There are Quick Start Guides for creating animation (non-musical) and musical sequences, Flash Tutorials and much more at: www.lightorama.com Support The following Wiki is also an excellent source of information on all things Light-O-Rama: www.lorwiki.com There is also a very active and helpful Light-O-Rama user community on Planet Christmas: www.planetchristmas.comtroubleshooting Status LED LED blinking approximately twice/second: Controller has booted correctly and is waiting for commands. 19 20

The controller is not connected to a Light O Rama network or the network is not active. LED is on solid: Controller is connected to an active network (is receiving the heartbeat and commands from a PC or a Show Director) LED is blinking fast: The normal operation jumper is not on JP3, the controller is resetting. See the section on Reset / Normal Operation Jumper for placement of the jumper. LED is not on at all: There is no power to the right side of the controller, verify power source with a working lamp. The right fuse is blown power the controller off and swap the left and right fuses or try a new fuse on the right side. AutoConfigure fails to find COM port If the COM port is not detected, you can manually select it from the drop down list. If you are not sure which COM port is the RS485 adapter and you have a USB adapter, click start My Computer View System Information Hardware tab Device Manager button. Click the + in front of Ports (COM & LPT) you will see USB Serial Port (COMn) this is the RS485 adapter. Use the Manual Select drop-down box to select that COM port. If you are not sure which COM port is the RS485 adapter and you have a serial port RS485 adapter, you will have to consult your PC s documentation, it is normally COM1, COM2 or COM3. You can try the Unit ID assignment steps with each serial port in succession. Hardware Utility Refresh Fails Use the procedure in the section Assigning a Unit ID to assign a unit ID to the controller. If this has been done and Refresh still does not work, try manually typing the controller number into the box to the right of the Refresh button. Use the options in the Test Unit s Operation section of the Hardware Utility window to see if the controller can be controlled. Updating Controller Firmware Periodically, Light-O-Rama will distribute new firmware for your g3. If you believe you need updated firmware, use the Hardware Utility do determine your current firmware version. Use the Refresh button to find your controller and check its firmware version. The drop-down menu to the right of the Refresh button will be filled in with the attached controllers. The right part of the controller name in this drop-down is the current firmware version. If the controller type or firmware version is not present, get the latest Hardware Utility from www.lightorama.com Support (bottom of page) Download Hardware Utility. Run program downloaded to install the Hardware Utility and devices text file. Retry the Refresh operation. The latest firmware can be found by going to www.lightorama.com Support and scrolling down to the Using the Hardware Documentation and 21 22

Firmware section. Find your controller and roll the mouse over the Firmware button look at the bar in the lower left of the browser window. It will show the name of the firmware file. The file name contains the version at the end. If the version number is greater than what you saw in the Hardware Utility, new firmware is available. Click the Firmware button to download the firmware to your PC remember where you put it. To load new firmware, use a data cable (not wireless) to connect the controller(s) to the PC. Start the Hardware Utility and click the Refresh button to find your controller(s). Select the one you want to update from the drop-down menu to the right of the Refresh button. Click the Firmware button at the bottom of the window. In the Firmware section of the window, under Step 1 Select Unit, select the unit listed above. Under Step 2 Select Firmware File, use the Open button to browse to the firmware file you downloaded. Under Step 3 Press Download Button click the Download button. Do not interrupt this process. Your controller will reboot after the download completes. You can click the Refresh button to see that the new firmware was loaded into your controller. Repeat this process for additional controllers. Specifications Configuration Individual Channel Capacity Individual Bank Capacity Board Capacity Single Power Feed Board Capacity Dual Power Feed Supply Voltage (two separate models) Fuses Isolation Power Connections No Heat Sinks Regular Heat Sinks Plastic enclosure Two banks of 8 channels 1 amp No Heat Sinks 8 amps Regular Heat Sinks 8 amps No Heat Sinks 15 amps Regular Heat Sinks 15 amps No Heat Sinks 15 amps Regular Heat Sinks 16 amps No Heat Sinks 30 amps Regular Heat Sinks 120 VAC, 50/60 Hz 240 VAC, 50/60 Hz 15 amp fast acting Optos isolate line voltage from control logic Quick connects (spade lugs) 6 ¾ w x 5 ¼ h x 1 ½ d 7 ¼ w x 6 ¾ h x 2 ¼ d 9 ½ w x 11 ½ h x 3 ½ d Light-O-Rama, Inc. Tel: (518) 539-9000 Fax: (518) 538-0067 info@lightorama.com 23