ELECTROMAGNETIC FLOWMETER COMPACT



Similar documents
How To Use A Flowmeter

Plastic tube flowmeters Series PT/PS

Conductive Level Switch FK 2 Technical Data:

Quick Connect. quick - simple - efficient.

Turbine Flow Sensor Series VTR

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

HERZ-Thermal Actuators

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Flow switches Series AD/VH

SITRANS F flowmeters SITRANS F M

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Digital inductive conductivity transmitter

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Relative and absolute pressure switch type 529

Digital display DA 48

Electronic Pressure Switch EDS 300

Operating Instructions for Plastic Flow Meter. Model: KSK

Multifunction devices

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Turbine Flowmeter Vision 1000 Flowrates 0,1-2,5L/min. Turbine Flowmeter Vision 2000 Flowrates 0,5-35L/min

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Electromagnetic Flow Meter

Inductive Proximity Sensors

Features. Picture. Specifications

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Combi switchbox with integrated 3/2 way pilot valve

Assisted lift operated 2/2-way solenoid valves Type EV250B

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Precision Mass Flow Meters / Controllers for Liquids and Gases

Electronic Pressure Switch EDS 3000

Digital input modules

Solenoid valves 2/2-way direct-operated Type EV210A

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Cable Plug acc. to DIN EN , Form A

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Liquid Leakage Sensor Amplifier

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

3/2-way Solenoid Valve, direct-acting, NC or NO

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

IFC 070 Technical Datasheet

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

COMBIMASS. Technical Data COMBIMASS eco-bio +

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Electric Rotary Actuator - On/Off or programmable control actuator

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

Flexible Counter Series in DIN size 24 x 48 mm

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Panel Meters and Controllers Modular Panel Meter Type EDM 35

PIEZOMETER AIRFLOW MEASURING RING

J TB/TW Temperature limiter, temperature monitor

CONFIGURABLE SAFETY RELAYS

Digital Keypad Use s Manual

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

LC/LCD ranges level controllers

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Compact pressure switch Flameproof enclosure Ex d Model PCA

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Operating Instructions

Vacuum drying oven for non-flammable solvents

Datalogger DL/N 70 Version:

Solenoid valves Type EVU

Proximity Sensors Inductive Thermoplastic Polyester Housing Types EI, DC, M 12, M 18, M 30

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Liquid Level Limit Switch liquiphant T FTL 20

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Duct Humidity Transmitter

Proportional pressure regulators VPPE

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TMS TANK MANAGEMENT SYSTEM

Short information Parameters are programmed via front-side membrane keypad

Three-phase monitoring relay CM-PFE

Maximum Demand Control

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Sanitary Type Electronic Flow Switches

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Pressure transmitter For general industrial applications Model A-10

API Marine. BMS Presentation. Ballast Measurement Systems

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Transcription:

R ELECTROMAGNETIC FLOWMETER COMPACT For conductivit Liquids MIK frequency-, switching-, analog otput digital plug on display Range from liquids, acids and caustic solutions:0.01-0.5...35-7000l/min Accuracy: ± 2,0% of full scale P max : bar; t max : 80ºC Connection:G½...2¾ male, diverse accessories Material: normal liquids: PPS, stainless steel agressive liquids: PVDF, Hastelloy or Tantalum Advantage: no moving parts in the mesuring tube low pressure los any mounting position short reaction time - replacement for zcalorimetric flow switch high quality for lowest price dosing eletronic compact eletronic

Despriction The new KOBOLD Flow meter Type MIK is used for measuring and monitoring smaller and medium-sized ow of conductivity liquids in pipes. The device operates according to the electromagnetic measurement principle. According to Faraday s Law of magnetic induction a voltage is induced in a conductor moving through a magnetic field. The electrically conductive measuring agent acts as the moved conductor. The voltage induced in the measuring agent is proportional to the flow velocity and is therefore a value for the volumetric flow. The flowing media must have a minimum conductivity. The induced voltage is picked up by two sensing electrodes which are in contact with the measuring agent and sent to the measuring ampli er. The flow rate will be calculated based on the cross sectional area of the pipe. The measurement is not depending on the process liquid and its material properties such as density, viscosity and temperature. The device may be equipped with a switch, frequency or analogue output. Moreover, there is a compact electronic system to be selected from, which contains a switch and an analogue output. The device series is completed by an optionally obtainable dosing and counter electronic system. The counter electronics system shows the current flow rate on the first line of the display and shows the partial or overall volume on the second line. A dosing electronic system controls simple filling duties and also measures the flow rate, overall volume and filling volume. The analogue output and two relay outputs can be utilised for the further processing of signals. Medias Electric conductivity liquids Acids and caustic solutions Drinking, cooling and waste water Ground water, raw water Aggressive or salty solution Unsuitable for oil (missing conductivity) Areas of Applicationn Flow monitoring, flow measuring, dosing and counting for Machine building Chemical Industry Paper Industry Automobile Industry Cement Industry Laboratory Technical Datan Range: see table Accuracy: ±2.0 % of f. s. Repeat accuracy: ±1.0 % of f. s. (f. s. = full scale) Measurement process: electromagnetic Electrical conductivity: min. 30 µs /cm Mounting position: in all directions, flow in direction of the arrow In-/Outlet: 3 x DN / 2 x DN Media temperature: -20... +80 C (max. +60 C with PVC-connection set) Ambient temperature: -10... +60 C Max. pressure: 10 bar Max. pressure loss: max. 250 mbar at f.s. Wetted Partsn Sensor housing: PPS or PVDF, fibreglass-reinforced Connection set: PVC-glue connection or hose connection, weld-on ends stainless steel 1.4404 Elektrodes: stainless steel 1.4404, Hastelloy C4 or Tantalum Seal: NBR, FPM or FFKM Response time t 90 : ca. 1 s Protection: IP 65 Connection/Ranges

MIK-...F300, MIK-...F390 Impulse output: PNP, Open Collector, max. 200 ma 500 Hz at f. s. (...F300) 50...1000 Hz at f. s. (...F390) factoryset as per customer request Power supply: 24 V DC ±20 % Power consumption: 60 ma MIK-...S300, MIK-...S30D Electrical connection: plug M 12 x 1 duo-led for switch status Switching output: relay SPDT, max. 1A/30V DC or aktive 24 V DC, N/C / N/O Schaltpunkt: 10...100% of f. s. in 10%-Steps that can be con gured by the customer using a rotary switch Power supply: 24 V DC ±20 % Power consumption: 80 ma Electrical connection: plug M 12 x 1, 5-pin MIK-...L303; MIK-...L343 Output: 0(4)-20 ma, 3-wire Max. load: 500 Ω Spannungsversorgung: 24 VD C ±20% Power consumption: 80 ma Electrical connection: plug M 12 x 1 MIK-...L443 (usage with AUF- 3000) Output: 4-20 ma, 3-wire Max. load: 500 Ω Power supply: 24 VD C ±20% Power consumption: 80 ma Electrical connection: plug DIN 43650 MIK-...C3xx (Compact electronics) 3-digit LED Analogue output: (0)4...20 ma adjustable (only MIK-...C34x) Max. load: 500 Ω Switching output: 1(2) semiconductor PNP or NPN, set at factory Contact function: N/C / N/O-frequency programmable Settings: via 2 buttons Power supply: 24 V DC ±20 %, 3-wire Power consumption: 120 ma Electrical connection: plug M 12 x 1 MIK-...Exxx (Counter electronics) Quantity meter: Analogue output: Load: Switching output: Settings: Functions: Power supply: Power consumption: Electrical connections: LCD, 2 x 8 digit, illuminated total, part and flow quantities, units selectable 8-digit (0)4...20 ma adjustable max. 500 Ω 2 relays, max. 250 V/5 A/1000 VA via 4 buttons reset, MIN / MAX memory, flow monitor, monitoring for part and total quantity, language 24 V DC ±20 %, 3-wire approx. 150 ma cable connection or M 12 plug more technical details see data sheet ZED in the brochure Z2 MIK-...Gxxx (Dosing electronics) Quantity meter: Dosage: Analogue output: Load: Switching output: Settings: Functions: Power supply: Power consumption: Electrical connection: LCD, 2 x 8 digit, illuminated dosing-, total-, and flow quantity, units selectable 8-digit 5-digit (0)4...20 ma adjustable max. 500 Ω 2 relays, max. 250 V/5 A/1000 VA via 4 buttons dosing (relay S2), start, stop, reset, fine dosing, correction amount, flow switch, total quantity, language 24 V DC ±20 %, 3-wire approx. 150 ma cable connection or M 12 plug more technical details see data sheet ZED in the brochure Z2

Electrical Connections MIK-...S300 MIK-...S30D MIK-...L3x3, MIK-...F3x0 MIK-...L443 MIK-...C30* MIK-...C34* MIK-...E14R, MIK-...G14 Cable Connection Plug Connection

Order Details (Example:MIK-5NA 10 A F300) Weight Sensor Weight Electronics

Dimensions MIK-...F3x0, MIK-...S30x, MIK-...L3x3 MIK-...L443 MIK-...C3xx MIK-...Ex4R, MIK-...Gx4R

Dimensions connection set PVC-glue connection Dimensions connection set PVC-hose connection Dimensions connection set stainless steel weld-on ends