Imaging in the SEM. Monte Carlo simulations of electrons in silicon. » Images are formed. » These interactions do. » The size of this volume

Similar documents
View of ΣIGMA TM (Ref. 1)

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

7. advanced SEM. Latest generation of SEM SEM

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

The Basics of Scanning Electron Microscopy

Ion Beam Sputtering: Practical Applications to Electron Microscopy

Name: Due: September 21 st Physics 7230 Laboratory 3: High Resolution SEM Imaging

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

Scanning Electron Microscopy Primer

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

Scanning Electron Microscopy: an overview on application and perspective

Vacuum Evaporation Recap

Physics 441/2: Transmission Electron Microscope

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

TOF FUNDAMENTALS TUTORIAL

CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 8: Microscopy and Imaging

X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION

Electron Microscopy SEM and TEM

How To Understand Light And Color

Scanning He + Ion Beam Microscopy and Metrology. David C Joy University of Tennessee, and Oak Ridge National Laboratory

Lenses and Apertures of A TEM

Sound absorption and acoustic surface impedance

Fundamentals of Scanning Electron Microscopy

EDXRF of Used Automotive Catalytic Converters

Coating Thickness and Composition Analysis by Micro-EDXRF

Atomic Force Microscopy. Long Phan Nanotechnology Summer Series May 15, 2013

Coating Technology: Evaporation Vs Sputtering

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

Usage of AFM, SEM and TEM for the research of carbon nanotubes

Evaluating Surface Roughness of Si Following Selected Lapping and Polishing Processes

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Looking through the fish-eye the Electron Ronchigram. Duncan T.L. Alexander CIME seminar May 24, 2012

The Focused Ion Beam Scanning Electron Microscope: A tool for sample preparation, two and three dimensional imaging. Jacob R.

Graphical displays are generally of two types: vector displays and raster displays. Vector displays

Infrared Viewers. Manual

A Remote Plasma Sputter Process for High Rate Web Coating of Low Temperature Plastic Film with High Quality Thin Film Metals and Insulators

Nanoelectronics 09. Atsufumi Hirohata Department of Electronics. Quick Review over the Last Lecture

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Cathode Ray Tube. Introduction. Functional principle

X-ray thin-film measurement techniques

Objectives 200 CHAPTER 4 RESISTANCE

Copyright by Mark Brandt, Ph.D. 12

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Information about the T9 beam line and experimental facilities

Principles of Ion Implant

Nano-Spectroscopy. Solutions AFM-Raman, TERS, NSOM Chemical imaging at the nanoscale

Bar Code Label Detection. Size and Edge Detection APPLICATIONS

Mass production, R&D Failure analysis. Fault site pin-pointing (EM, OBIRCH, FIB, etc. ) Bottleneck Physical science analysis (SEM, TEM, Auger, etc.

Properties of Electrons, their Interactions with Matter and Applications in Electron Microscopy

Sample preparation for X-ray fluorescence analysis

Dose enhancement near metal electrodes in diamond X- ray detectors. A. Lohstroh*, and D. Alamoudi

Usage of Carbon Nanotubes in Scanning Probe Microscopes as Probe. Keywords: Carbon Nanotube, Scanning Probe Microscope

Introduction to Geiger Counters

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Solid State Detectors = Semi-Conductor based Detectors

Encoders for Linear Motors in the Electronics Industry

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Diffraction of a Circular Aperture

Preface Light Microscopy X-ray Diffraction Methods

CREOL, College of Optics & Photonics, University of Central Florida

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

VCR Ion Beam Sputter Coater

ENGINEERING METROLOGY

EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system

Physics 30 Worksheet # 14: Michelson Experiment

Lecture 6 Scanning Tunneling Microscopy (STM) General components of STM; Tunneling current; Feedback system; Tip --- the probe.

DualBeam Solutions for Electrical Nanoprobing

British Journal of Science 43 September 2012, Vol. 6 (2) Study of the Objective Focal Properties for Asymmetrical Double Polepiece Magnetic Lens

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

OmniBSI TM Technology Backgrounder. Embargoed News: June 22, OmniVision Technologies, Inc.

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Light Control and Efficacy using Light Guides and Diffusers

Lapping and Polishing Basics

Secondary Ion Mass Spectrometry

Introduction to microstructure

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE Dr. Alan Doolittle

THERMO NORAN SYSTEM SIX ENERGY DISPERSIVE X- RAY SPECTROMETER. Insert Nickname Here. Operating Instructions

Experiment 5. Lasers and laser mode structure

It has long been a goal to achieve higher spatial resolution in optical imaging and

Near-field scanning optical microscopy (SNOM)

Laserlyte-Flex Alignment System

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Alignement of a ring cavity laser

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Experiment 3 Lenses and Images

Theremino System Theremino Spectrometer Technology

Appendix A. An Overview of Monte Carlo N-Particle Software

Microscopy and Nanoindentation. Combining Orientation Imaging. to investigate localized. deformation behaviour. Felix Reinauer

Lectures about XRF (X-Ray Fluorescence)

Applications of confocal fluorescence microscopy in biological sciences

This paper describes Digital Equipment Corporation Semiconductor Division s

BB-18 Black Body High Vacuum System Technical Description

Ultrasonic Wave Propagation Review

Introduction to the Scanning Electron Microscope

Transcription:

Signal Detection

Imaging in the SEM» Images are formed because of the beam interactions that occur» These interactions do not occur at a point, but all through some volume of the sample» The size of this volume varies with beam energy... Monte Carlo simulations of electrons in silicon

Shape of interaction volume».and the shape of the interaction volume depends on the atomic number Z» High Z elements give more elastic scattering so the electrons are deflected more Carbon Z = 6 Copper Z = 29 Gold Z = 79

Detector efficiency contrast» SE emitted towards the detector are more likely to be collected than those traveling away from the detector since typical SE detectors collect <50% Beam not collected Detector collected» The position of a surface relative to the detector will therefore affect how bright it looks in the image.» This detector efficiency contrast is combined with topographic contrast 10% collected -dark 50% collected - somewhat bright 100% collected - bright

Lower Detector» The detector position therefore affects the image appearance Indent in Si» The lower (ET) detector views the sample from one side and so the face looking away from the detector is shadowed To detector

Upper detector» The upper (through the lens) detector views the sample from above» The SE collection is now symmetrical and so all faces of the indent are equally visible. They are brighter than the flat surface because of topographic contrast.

Back Scattered Electrons» Although secondary electron imaging is the most popular mode in the SEM, back scattered electrons (BSE) are very versatile and offer some unique kinds of information» Key difference - BSE are incident electrons scattered back out of the sample, SE are electrons which start out in the specimen» The BSE yield increases with Z and incident angle» Large, symmetric BSE detector required Z contrast from Igneous rock

Imaging performance» The probe size is determined by the combined effect of the aberrations of the lens» The magnitude of the aberrations vary with the focal length of the lens - which is about equal to the working distance» Some lens designs are more capable than others at combining both high performance and good sample access

The pinhole lens» The original SEM lens - designed so as to produce no magnetic field in the sample chamber» Good sample access» Long working distance (focal length) and so high aberrations» Poor EM screening» Asymmetric SE collection due to position of ET

The immersion lens» Short focal length - so low aberrations» Good EM screening» Very stable specimen mounting in lens» Symmetric SE collection using the through the lens (TTL) detector system» But restricted to small samples (3mm discs)

Snorkel (or Single Pole) Lens» Based on an original idea by Prof.Tom Mulvey in 1970» Short focal length - so low aberrations and high performance» Good EM screening» The sample is outside the lens so there is no limitation on the size of the specimen» Can support BSE + two SE detectors for great imaging flexibility.. S-4700 lens configuration Excitation - 1000 amp.turns

SE detectors» Snorkel lens permits multiple detectors to be used» In-lens (TTL) detector gives a shadow free image with ultrahigh topographical resolution. With ExB filter also acts as a BSE detector» Lower (ET) detector gives SE images with material contrast information and high efficiency at high tilt angles» These detectors can be used separately or combined Snorkel lenses allow multiple detectors

Two detectors - different signals» The upper and lower detectors have a different viewpoint of the specimen and so they see the specimen differently» In addition these two detectors collect a different mix of the electrons emitted from the sample...

Image Content SE1 TTL» SE1 - produced as the beam enters the sample. These are the high resolution SE Lens BSE SE2 Detector ET» SE2 - are produced by the BSE as they leave. Low resolution SE SE escape SE2 SE1 SE3» SE3 - tertiary signal, not from the specimen at all

SE Comparison Upper SE Detector Lower SE Detector Vision Goggles- This sample is a hole-punched silicon wafer with various metals deposited on its surface. The upper detector image shows the metal layer banding on the inside walls of the holes. We are able to see into the holes to gain an understanding of the location of contamination within. The lower detector image emphasizes the surface details and the top portion of the contaminants without the effect of charging in the image.

The signal mix» Measurements show that lower detector sees a signal which is typically 40% SE3, 45% SE2, about 15% SE1 and some direct BSE signal» The upper (TTL) detector sees a signal mix which is about 75% SE2 and 25% SE1» The upper detector therefore contains a much lower BS component in its signal output and so gives higher contrast images

Alignment/Collection Dilemma f d f d f f

S-4700 Detection System» The ExB filter can now be used to select the mix of electrons reaching the upper detector» The system can be adjusted to give images consisting of from pure SE to pure BSE, and anywhere in between» This provides great flexibility in overcoming charging and in optimizing imaging contrast SE BSE» SE to BSE ratio changes by altering the amount of SEs collected

New E B e Upper Detector New E B e Upper Detector Topo - SE Mode Compo - BSE Mode SE >> BSE SE BSE BSE + SE Positive Negative

100% SE image» At one end of the range the TTL detector sees a true SE image» The energy range of the electrons from which this image is formed can further be tuned by using the stage bias Device imaged in S-4700 with ExB

100% BSE» At the other end of the control range a true BSE image is available» Between these two extremes are mixtures which combine the features of both SE and BSE but may be much less prone to charging 100% BSE image S-4700 with ExB

Upper Detector Versatility SE Image Edge effect (no detail) Topographic information Charged-up SE/BSE Image No edge effect, detailed edges Composite information No charging visible

Minimizes Charge Appearance Full SE Mode Full BSE Mode Teflon Tape- Notorious for its charging characteristics, this sample is actually charging in both images. However, the right image is made up of electrons (BSEs) that do not represent the top surface where the charge is occurring.

Reduces Contamination Appearance Images thru contamination! Full SE Mode BSE Mix Mode ITO Film- Even in the cleanest vacuum systems hydrocarbons on the sample s surface can interfere with low voltage imaging because of its shallow interaction volume. By selecting a moderate setting on the ExB filter, the contamination is removed from the image and the sample details beneath the hydrocarbons can be seen.

High Resolution BSE Imaging Vias- Here the backscattered electron signal highlights the tantalum barrier as well as the surface structure within the vias. With the ExB image we can confidently measure the thickness of the tantalum barrier. Notice the short WD for high resolution. This is a valuable benefit of the ExB Filter. Other BSE detectors force the WD to 8mm and longer.

Biological Applications Salmonella Bacteria- Here the BSE signal highlights the gold label particles on the salmonella bacteria. The gold labels are used to mark various proteins of interest. These high resolution images confirm the theory that the particles are 10nm in diameter and show that most tagged proteins are located on the strands between the bacteria.

S-4800 Signal Detection» Same ExB Filter as S- 4700» Addition of plates within the objective lens designed to collect and convert BSEs into SEs» Therefore ratio of SE to BSE changes by adjusting SE and BSE signal SE BSE

S-5200 ExB Detection Mode 1 2 e Pure SE e Filtered SE Plate SED2 Plate SED2 (Option) (Option) ExB ExB SED1 SED1 (STD) (STD) Electrode Electrode SE BSE SE BSE sample sample

S-5200 ExB Detection Mode 3 4 e Compo-rich e BSE Plate SED2 Plate SED2 (Option) (Option) ExB ExB SED1 SED1 (STD) (STD) Electrode Electrode SE BSE SE BSE sample sample

STEM in the SEM sample Image courtesy Bill Roth NSA To ET detector Scatter surface» A FEGSEM also allows excellent STEM operation. A simple adapter permits bright and dark field STEM observation.» Ideal for biological science - high contrast even from unstained samples.

STEM Imaging Objective Lens Sample STEM Aperture STEM Detector Primary Beam Actual STEM Holder Sample External View of Detector Low voltage STEM imaging at 30kV in an SEM can provide high contrast on low atomic number materials. STEM images of various sample types is possible, from semiconductors to powders to biological samples. The BF-STEM detector is always mounted to the chamber so it is easy to switch between STEM imaging from other imaging modes. The majority of the following examples have both SE and STEM images so that comparisons can be made. The STEM signal is selectable in the software so that alignment and image focus can be done using the SE image and then compared to STEM information.

LVSTEM S-5000 Image» In STEM mode the beam penetration is high.» Here a metal contact, prepared for 100keV TEM observation is viewed in STEM at 30keV. Note excellent contrast and resolution Bright field STEM image from S-5000 FEG SEM.

Simultaneous STEM Imaging Obj lens Upper SE Detector SE DF-STEM Detector Sample BF-STEM 50nm Reflection plate DF-STEM 50nm Aperture for BF-STEM BF- STEM Detector 50nm

Carbon Nanotubes B A SE A step towards their practical use is in the purification of catalytic metals. Using the STEM detector, the inner contents of these nanotubes is visible. In combination with EDS analysis, we can measure 20nm or less of iron that is used in the growing process. A STEM Fe B

STEM Carbon Nanotube The SE image below shows excellent surface structure. The structure is also visible in STEM mode. At 800,000x the internal growth structure of the nanotube and internal tube diameter can be accurately measured. SE STEM 5nm