station) on the serial port

Similar documents
Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

WeatherLink for Alarm Output. Introduction. Hardware Installation and Requirements. Addendum

WeatherLink for Vantage Pro and Vantage Pro2

Reference Guide. Vantage PRO2 Quick

For more detailed information, see your Vantage Vue Console manual.

WeatherLink for Vantage Pro and Vantage Pro2

USER MANUAL. Console. For Vantage Pro2 and Vantage Pro2 Plus

Vantage Pro2 Console Manual. For Vantage Pro2 & Vantage Pro2 Plus Weather Stations

Estação Meteorológica sem fio VEC-STA-003

8. Barometric Trend Arrow 9. Graph Icon 10. Current Rain Icon 11. Station Number Indicator 12. Weather Ticker 13. Graph Field 14.

EXPLANATION OF WEATHER ELEMENTS AND VARIABLES FOR THE DAVIS VANTAGE PRO 2 MIDSTREAM WEATHER STATION

3465 Diablo Avenue, Hayward, CA U.S.A Fax:

WeatherLink for Emergency Response Teams Addendum

Weather Station Digital Display User s Manual. Version 1.5

Wireless Vantage Pro 2 & Vantage Pro Plus 2 Stations

Setup of an internet enabled Davis Vantage Pro2 weather station using a Raspberry Pi Zeist Hoge Dennen October 2014

User Manual for CH-PFC76810

Weather Capture Software Guide Version 1.4 Revision: June

Vue. Davis Instruments, 3465 Diablo Avenue, Hayward, CA U.S.A

Cabled Vantage Pro2 & Vantage Pro2 Plus Stations

PROFESSIONAL WEATHER STATION (WIND AND AIR PRESSURE) Operation Manual

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

SDI Multi Sensor Module with Charger Enclosure Station Support

GETTING STARTED GUIDE. Envoy8X

HTTP Data Logging Protocol

Complete System Shelter

CABLE FREE TM WEATHER STATION

WEATHER STATION FOR SOLAR FARM MONITORING

=============================== WARNING

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

[USING THE NM150 WITH ADULTICIDING] July 13, 2015

Modbus and ION Technology

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

Weather Instruments. Precision. new Davis. weather products: See our. Weather Monitoring Systems for Home, School, Industry & Agriculture

Metering for today s systems

USER MANUAL INTRODUCTION CONTENTS PACKAGING CONTENTS BASE STATION WIND SENSOR TEMPERATURE & HUMIDITY SENSOR

WS1093 PROFESSIONAL WIRELESS WEATHER STATION WITH TOUCHSCREEN AND USB UPLOAD

Precision. Weather Instruments. Weather Monitoring Systems for Home, Agriculture, Industry and School. Your Weather Catalog

Activity 8 Drawing Isobars Level 2

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

TOUCH SCREEN WEATHER STATION (WIND AND AIR PRESSURE) WH-1080PC. Operation Manual

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

USER MANUAL. Vantage Connect. Vantage Vue and Weather Envoy. Product numbers 6620 & 6621

WEB log. Device connection plans

Vantage Pro2 Temperature/Humidity Sensor Replacement Kit

INSTALLING A/C ADAPTER

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

MoTeC USA GPS. Part # M GPS BL Available in 10 Hz or 20 Hz. USER MANUAL Version 1.4

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

Weather Instruments. new! Precision

Fingerprint Based Biometric Attendance System

IntesisBox KNX LG Air Conditioning

Basic Climatological Station Metadata Current status. Metadata compiled: 30 JAN Synoptic Network, Reference Climate Stations

USER MANUAL V5.0 ST100

WEATHER INSTRUMENTS. Your Weather in Real Time. Precision LOCAL OR REMOTE: WEATHER MONITORING SYSTEMS FOR HOME, AGRICULTURE, INDUSTRY AND SCHOOL

WEB log. Device connection plans

Temperature & Humidity SMS Alert Controller

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

1. SAFETY INFORMATION

APPENDIX C METEOROLOGICAL STATION DATA

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

1 Application Description Objective Goals... 3

MANUAL PC1000R

How To Set Up A Protocessor Protonode

Modbus and ION Technology

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

06MAR THU 12: User Manual

DS1621 Digital Thermometer and Thermostat

Portable BACnet /IP to MS/TP Router

KTA-223 Arduino Compatible Relay Controller

La Crosse Technology. Heavy Weather. Software User s Guide. (for 2800 series weather stations with USB connectivity) Revision: 1.3

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SKY LIGHT INTERSECTION SYSTEM

Vaisala Weather Transmitter WXT510 The Most Essential of Weather

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Digital and Analog I/O

Unidirectional Transmitter/ Receiver Units Introduction

Wireless Soil Moisture and Weather Monitoring System Caipos

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

USING WIRELESS DIAGNOSTICS Application Note 31

RPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:

PRODUCT LIST Facility DDC Access WebXL DDC

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

VOICE RECORDING SYSTEM ISDN PRI / BRI

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

RC2200DK Demonstration Kit User Manual

IntesisBox KNX Mitsubishi Heavy Industries AC

Bluetooth UART/RS232 Module

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

SAUTER BACnet PICS EY-modulo 5 moduweb500 BACnet Protocol Implementation Conformance Statement

FLYPORT Wi-Fi G

IntesisBox ASCII Server - LON

MCS-BMS-GATEWAY STARTUP GUIDE

SMART SENSOR COLLECTION

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

Transcription:

Connects a Davis VantagePro2 or Vantage Vue to a BACnet network BACnet MS/TP over RS-485 compatible Easy BACnet network configuration via onboard switches Various selectable metric and imperial unit conversions Compatible with new Davis firmware; provides additional weather data Configurable alarm on gateway with two open collector outputs Connections Connection Description V + Power Positive (8 to 28V DC; 100mW) GND Power Negative (Ground) D + RS-485 Data + D - RS-485 Data - GND Ground Male DE-9 Serial communications (RS-232) between KTA-302 and Weather station via WeatherLink cable Ethernet The Ethernet connector is not used for BACnet functions. OC1 Open Collector Output 1 OC2 Open Collector Output 2 LED Red Tx LED (next to RS-485 terminal) Green Rx LED (next to RS-485 terminal) Green Rx LED next to DE-9 connector Red Tx LED next to DE-9 connector Function Indicates serial communications sent on RS-485 Indicates serial communications received RS-485 Indicates serial communications received (from weather station) on the serial port Indicates serial communications sent on the serial port Setting Up BACnet Address and Baud Rate The BACnet address and the baud rate are set through the switches near to the RS-485 connector. Setting the Baud Rate: Baud Rate Switch 7 Switch 8 9600 OFF OFF 19200 ON OFF 38400 OFF ON 78800 ON ON Setting the BACnet MAC ID The BACnet MAC ID is set through the bit switches from 1 to 6 using binary decoding. Each switch represents the binary value and the address is set by the combination of those switches. The configurable range is from 0 to 63. See address table bellow. 7 Apr 2016 oceancontrols.com.au 1 of 7

Address SW1 SW2 SW3 SW4 SW5 SW6 Address SW1 SW2 SW3 SW4 SW5 SW6 0 OFF OFF OFF OFF OFF OFF 32 ON OFF OFF OFF OFF OFF 1 OFF OFF OFF OFF OFF ON 33 ON OFF OFF OFF OFF ON 2 OFF OFF OFF OFF ON OFF 34 ON OFF OFF OFF ON OFF 3 OFF OFF OFF OFF ON ON 35 ON OFF OFF OFF ON ON 4 OFF OFF OFF ON OFF OFF 36 ON OFF OFF ON OFF OFF 5 OFF OFF OFF ON OFF ON 37 ON OFF OFF ON OFF ON 6 OFF OFF OFF ON ON OFF 38 ON OFF OFF ON ON OFF 7 OFF OFF OFF ON ON ON 39 ON OFF OFF ON ON ON 8 OFF OFF ON OFF OFF OFF 40 ON OFF ON OFF OFF OFF 9 OFF OFF ON OFF OFF ON 41 ON OFF ON OFF OFF ON 10 OFF OFF ON OFF ON OFF 42 ON OFF ON OFF ON OFF 11 OFF OFF ON OFF ON ON 43 ON OFF ON OFF ON ON 12 OFF OFF ON ON OFF OFF 44 ON OFF ON ON OFF OFF 13 OFF OFF ON ON OFF ON 45 ON OFF ON ON OFF ON 14 OFF OFF ON ON ON OFF 46 ON OFF ON ON ON OFF 15 OFF OFF ON ON ON ON 47 ON OFF ON ON ON ON 16 OFF ON OFF OFF OFF OFF 48 ON ON OFF OFF OFF OFF 17 OFF ON OFF OFF OFF ON 49 ON ON OFF OFF OFF ON 18 OFF ON OFF OFF ON OFF 50 ON ON OFF OFF ON OFF 19 OFF ON OFF OFF ON ON 51 ON ON OFF OFF ON ON 20 OFF ON OFF ON OFF OFF 52 ON ON OFF ON OFF OFF 21 OFF ON OFF ON OFF ON 53 ON ON OFF ON OFF ON 22 OFF ON OFF ON ON OFF 54 ON ON OFF ON ON OFF 23 OFF ON OFF ON ON ON 55 ON ON OFF ON ON ON 24 OFF ON ON OFF OFF OFF 56 ON ON ON OFF OFF OFF 25 OFF ON ON OFF OFF ON 57 ON ON ON OFF OFF ON 26 OFF ON ON OFF ON OFF 58 ON ON ON OFF ON OFF 27 OFF ON ON OFF ON ON 59 ON ON ON OFF ON ON 28 OFF ON ON ON OFF OFF 60 ON ON ON ON OFF OFF 29 OFF ON ON ON OFF ON 61 ON ON ON ON OFF ON 30 OFF ON ON ON ON OFF 62 ON ON ON ON ON OFF 31 OFF ON ON ON ON ON 63 ON ON ON ON ON ON BACnet Services Supported Read Property Read Property Multiple Write Property Device Communication Control Reinitialise Device Who-Has Who-Is Standard Object-Types Supported Analogue Input Analogue Value Binary Value Device Date Value Integer Value Time Value Data Link Layer Option BACnet MS/TP master. Baud rates: 9600, 19200, 38400 and 78800 7 Apr 2016 oceancontrols.com.au 2 of 7

Device Object Properties Property Name/ID Access Default Object Identifier R 838000 + MAC Address Object Name R KTA-302 Object Type R Device System Status R Operational Vendor Name R Ocean Controls Vendor Identifier R 838 Model Name R KTA-302 BACnet Protocol Version R 1 Protocol Revision R 14 Max APDU Lenght R 128 APDU Timeout R 3000 ms Number APDU Retries R 3 Analogue Input Objects Analogue Input Objects are the values read from the Davis Weather Station. Analogue Objects Properties Object Identifier R See table bellow Object Name R See table bellow Object Type R ANALOG INPUT Present Value R Value read from Weather Station * Event State R NORMAL Out Of Service R FALSE Units R/W See table bellow for default *Alarm Flag set to true when the Davis Weather Station alarm is reached. The alarms have to be configured by Weather Link Software or on Weather Station Console. Analogue Objects Supported Object Name Instance Default Unit Supported Units Barometer Trend 3h 0 No_Units No_Units Barometer 1 mmhg InHg,mmHg,mb Inside Temperature 2 Deg C Deg F, Deg C Inside Humidity 3 % % Outside Temperature 4 Deg C Deg F, Deg C Wind Speed 5 m/s Mph, m/s, fps, kph Wind Speed Average 6 m/s Mph, m/s, fps, kph Wind Direction 7 Deg Deg Angular Extra Temperature 1 8 Deg C Deg F, Deg C Extra Temperature 2 9 Deg C Deg F, Deg C Extra Temperature 3 10 Deg C Deg F, Deg C Extra Temperature 4 11 Deg C Deg F, Deg C Extra Temperature 5 12 Deg C Deg F, Deg C Extra Temperature 6 13 Deg C Deg F, Deg C Extra Temperature 7 14 Deg C Deg F, Deg C 7 Apr 2016 oceancontrols.com.au 3 of 7

Soil Temperature 1 15 Deg C Deg F, Deg C Soil Temperature 2 16 Deg C Deg F, Deg C Soil Temperature 3 17 Deg C Deg F, Deg C Soil Temperature 4 18 Deg C Deg F, Deg C Leaf Temperature 1 19 Deg C Deg F, Deg C Leaf Temperature 2 20 Deg C Deg F, Deg C Leaf Temperature 3 21 Deg C Deg F, Deg C Leaf Temperature 4 22 Deg C Deg F, Deg C Outside Humidity 23 % % Extra Humidity 1 24 % % Extra Humidity 2 25 % % Extra Humidity 3 26 % % Extra Humidity 4 27 % % Extra Humidity 5 28 % % Extra Humidity 6 29 % % Extra Humidity 7 30 % % Rain Rate per Hour 31 mm In, mm UV Index 32 No_units No_units Solar Radiation 33 W/m2 W/m2 Storm Rain 34 mm In, mm Day Rain 35 mm In, mm Month Rain 36 mm In, mm Year Rain 37 mm In, mm Day Evapotranspiration 38 mm In, mm Month Evapotranspiration 39 mm In, mm Year Evapotranspitarion 40 mm In, mm Soil Moisture 1 41 millibar millibar Soil Moisture 2 42 millibar millibar Soil Moisture 3 43 millibar millibar Soil Moisture 4 44 millibar millibar Leaf Weatenesses 1 45 No_Units No_Units Leaf Weatenesses 2 46 No_Units No_Units Leaf Weatenesses 3 47 No_Units No_Units Leaf Weatenesses 4 48 No_Units No_Units Console Battery Voltage 49 V V Wet Bulb 50 Deg C Deg F, Deg C Wind Speed last 2 minutes 51 m/s Mph, m/s, fps, kph Wind Gust last 10 minutes 52 m/s Mph, m/s, fps, kph Wind Direction for 10 minutes gust 53 m/s Mph, m/s, fps, kph Dew Point 54 Deg C Deg F, Deg C Heat Index 55 Deg C Deg F, Deg C Wind Chill 56 Deg C Deg F, Deg C THSW Index 57 Deg C Deg F, Deg C Rain Last 15 minutes 58 mm In, mm Rain Last Hour 59 mm In, mm Rain Last 24 Hours 60 mm In, mm Barometric Sensor Raw Reading 61 mmhg InHg,mmHg,mb Absolute Barometric Pressure 62 mmhg InHg,mmHg,mb 7 Apr 2016 oceancontrols.com.au 4 of 7

Analogue Units Supported Unit Abrev. BACnet Code Degrees Fahrenheit Deg F 64 Degrees Celsius Deg C 62 Percent Relative Humidity % 29 Inches Of Mercury inhg 61 Millimetres of Mercury mmhg 59 Millibar mb 134 Inches In 32 Millimetres mm 30 Miles per Hour mph 78 Meters per Second m/s 74 Feet per Second fps 76 Kilometres per Hour kph 75 Volts V 5 Degrees Angular Deg 90 Watts per Square Meter W/m2 35 No Units No_Units 95 Time Objects Time Objects are read from the Davis Weather Station. Time Object Properties Object Name R (0) Time of Sunset (1) Time of Sunrise Object Type R TIME (50) Present Value R Values are read from Weather Station *These values require longitude and latitude to be set. Longitude and latitude can be set using the WeatherLink software or the Weather Station console. Date Object Date Object is read from the Davis Weather Station. Date Object Properties Object Identifier R 0 Object Name R Start date of current storm Object Type R DATE (42) Present Value R Value is read from Weather Station *These values require longitude and latitude to be set. Longitude and latitude can be set using the WeatherLink software or the Weather Station console. Analogue Value Objects Analogue Value Objects define the alarm set point value. See Alarm Section for further information. 7 Apr 2016 oceancontrols.com.au 5 of 7

Analogue Value Object Properties Object Name R (0) Set Point 1 (1) Set Point 2 Object Type R ANALOG VALUE Present Value R/W 0 Event State R NORMAL Out Of Service R FALSE Units R No_Units Relinquish Default R 0 *Proprietary Property /3306 R/W 1 See on Alarm Section *Proprietary Property has data type Enumerated. Integer Value Objects Integer Value Objects define which instance number will be controlled by alarm set points. See Alarm Section for further information. Integer Value Object Properties Object Name R (0) Instance of SP1 (1) Instance of SP2 Object Type R INTEGER VALUE Present Value R/W 0 Instance number of Analogue Input Object that should be controlled by alarm. Out Of Service R/W TRUE Write true to disable respective alarm Units R No_Units Relinquish Default R 0 Binary Value Objects Binary Value Objects show the status of the alarm open collector outputs. See Alarm Section for further information. Binary Value Object Properties Object Name R (0) OC Output 1 (1) OC Output 2 Object Type R BINARY VALUE Present Value R 0 Status of output Out Of Service R FALSE Event State R NORMAL Polarity R NORMAL 7 Apr 2016 oceancontrols.com.au 6 of 7

Alarms The KTA-302 BACnet Gateway provides two configurable alarms which can enable or disable two open collector outputs. To activate those alarms, the user has to set false in the Out of Service property of the Integer Value Object and configure the desirable parameters. Alarm 1 Object/Name Property Integer Value 0 / Instance of SP1 Present Value Write the instance number of the analogue input object to be controlled. Integer Value 0 / Instance of SP1 Out Of Service Enable or Disable the alarm Analogue Value 0 / Set Point 1 Present Value Write the desirable set point Analogue Value 0 / Set Point 1 Proprietary Property / 3306 Activate Alarm when: 0 Equal to SP 1 Greater than SP 2 Lower than SP 3 The alarm flag is activated Binary Value 0 / OC Output 1 Present Value Shows status of the OC1 output. Alarm 2 Object/Name Property Note Integer Value 1 / Instance of SP2 Present Value Write the instance number of the analogue input object to be controlled. Integer Value 1 / Instance of SP2 Out Of Service Enable or Disable the alarm Analogue Value 1 / Set Point 2 Present Value Write the desirable set point Analogue Value 1 / Set Point 2 Proprietary Property / 3306 Activate Alarm when: 0 Equal to SP 1 Greater than SP 2 Lower than SP 3 The alarm flag is activated Binary Value 1 / OC Output 2 Present Value Shows status of the OC2 output. 7 Apr 2016 oceancontrols.com.au 7 of 7