USER S GUIDE Humidity and Temperature USB Datalogger LOG32

Similar documents
USER S GUIDE Humidity and Temperature USB Datalogger

Datalogger Graph Software Help

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

User Guide. Temperature and Humidity Datalogger. Model 42280

EL-USB-1-LCD Temperature Data Logger with LCD


SupcoLog Logger Interface Software

Temperature Datalogger Users Manual

EL-USB mA Current Loop USB Data Logger

USB-500 Series Stand-Alone, Low-Cost Data Loggers

HOBO U14 Data Logger User Manual

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Low-Cost Data Loggers and Accessories

User's Guide. Integrating Sound Level Datalogger. Model Introduction

1. SAFETY INFORMATION

DataView DVTH Data Logger for Temperature and Humidity

HOBO Single Channel Thermocouple Data Logger (UX M) Manual

4-Channel Thermometer / Datalogger

RFID Logger Software User Manual Rev 1.0

TFA. KlimaLogg Pro. User Manual. Revision: 0.1

Model SL355 Noise Dosimeter/Datalogger

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Data-logger evaluation software GSoft V2.8

Weather Capture Software Guide Version 1.4 Revision: June

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Integrating Sound Level Meter and Datalogger

Alarm Security Kit - NVR

SNMP Web Management. User s Manual For SNMP Web Card/Box

Testo FlashUpdate. Instument Software Update and Download Instructions How to Download Instrument Software and Updates from the Internet

DG-100 Data Logger User Manual. Version 1.2

Single Use USB Data Logger EBI 330-T30 / EBI 330-T85. User Manual

User's Guide DylosLogger Software Version 1.6

Audience Response System (Turning Point) A Quick Start Guide

Model: Manual DC: WIRELESS COLOR FORECAST STATION

Using the T&D Thermo App with TR-7wf Data Loggers

etrex 10 quick start manual

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Cellular Edition TM- CELL400 User Guide. 1 TM- CELL400 Rev Temperature@lert

Preparing Log-ic 360 USB Loggers for Use

GPSMAP 62 series quick start manual. For use with the GPSMAP 62, 62s, 62st, 62sc, and 62stc

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Data Logging Solutions from Lascar Electronics

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

GPSMAP 62 series quick start manual. For use with the GPSMAP 62, 62s, and 62st

ExStik TM ph Waterproof Meters

Accessing vlabs using the VMware Horizon View Client for OSX

Current Monitoring Kit QUICK START GUIDE

USB-Based Temperature & Humidity Sensor

OARTEC SIMULATOR TRAINING MONITOR USER MANUAL Version 1.05

Current Monitoring Kit

PTR/DTR. Printing Thermometer Software. Software User Manual

NEED MORE HELP? PLEASE SEE OUR FAQ SECTION AT:

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

AUDITVIEW USER INSTRUCTIONS

User s Manual. Management Software for ATS

SoundLAB Software Download Software from the Bogen website:

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

Using USB Flash Drives

Estação Meteorológica sem fio VEC-STA-003

Surf it Easy. User Guide

GPSMAP 62 series quick start manual. For use with the GPSMAP 62, 62s, 62st, 62sc, and 62stc

Speedlink software will run on Windows NT, Windows 7, and Windows 8; it will run on both 32 byte and 64 byte versions of Windows.

Product information and manual for SensLab BT-Adapter (Model type: BT060721) for wireless data transfer of measurement data of Lactate Scout-handheld

site monitoring Kit Site Monitoring Kit User Manual we prove it.

Dual Laser InfraRed (IR) Thermometer

User Manual Network connection and Mobics Dashboard (MIS) software for Dryer Controller M720

SubCue Analyzer Software - Introduction

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

AUDITVIEW USER INSTRUCTIONS

Digital Photo Frame User s Manual

User Guide Reflow Toaster Oven Controller

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

TECTITE 4.0 (WiFi) and TEC WiFi Link Quick Guide

PowerShield SNMP Adaptor

HWg-STE HWg-STE PoE MANUAL

INSTALLING A/C ADAPTER

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

Field Calibration Software

EC500 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC500 Setup Guide - Page 1

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Copyright. Copyright LogTag Recorders. All rights reserved.

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Corsair Link v2.4 Manual. Initial Set-up. Placing devices within the chassis

EC150 BASIC SOFTWARE SETUP GUIDE. Read This First. Easy Clocking EC150 Setup Guide - Page 1

TC-9102 Series Surface Mount Temperature Controllers

INF-USB2 and SI-USB Quick Start Guide

WAM Remote Wireless Asset Monitoring. Website User Guide

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

USB FLASH DRIVE. User s Manual 1. INTRODUCTION FEATURES SPECIFICATIONS PACKAGE CONTENTS SYSTEM REQUIREMENTS...

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

USER GUIDE. LED Light Meter. Model LT45

How to Install and Set up a Jabra Go 6400 and Pro9400 Series Headset with an Avaya 96x1 Series IP Phone

ScreenBeam. Configurator for. Windows 8.1. User Manual V1.2

Crown Field Support Engineering

Transcription:

USER S GUIDE Humidity and Temperature USB Datalogger LOG32 REC ALM

FEATURES Memory for 32,000 readings (16000 temperature and 16,000 humidity readings) Dew point indication Status Indication USB Interface User-Selectable Alarm Analysis software Multi-mode to start logging Long battery life Selectable measuring cycle: 2s, 5s, 10s, 30s, 1m, 5m, 10m, 30m, 1hr, 2hr, 3hr, 6hr, 12hr, 24hr DISCRIPTION 1. Protective cover 2. USB connector to PC port 3. Start button 4. RH and Temperature sensors 5. Alarm LED(red/yellow) 6. Record LED(green) 7. Mounting clip

LED STATUS GUIDE Green LED REC ALM Red/Yellow LED LEDs Indication Action Both LED lights OFF Logging not active Or Low Battery One green flash every 10 sec. * Logging, no alarm condition** Green double flash every 10 sec. * Delayed start Red single flash every 10 sec. * -Logging, low alarm for RH*** Start logging Replace battery and download the data To start, hold the start button until Green and Yellow LED flash Red double flash every 10 sec. * -Logging, high alarm for RH*** Red single flash every 60 sec. - Low Battery**** Yellow single flash every 10 sec. * -Logging, low alarm for TEMP*** Yellow double flash every 10 sec. * -Logging, high alarm for TEMP*** If logging, it will stop automatically. No data will be lost. Replace battery and download data Yellow single flash every 60 sec. Download data - Logger memory full * To save power, the logger s LED flashing-cycle can be changed to 20s or 30s via the supplied software. ** To save power, alarm LEDs for temperature and humidity can be disabled via the supplied software. ***When both temperature and relative humidity readings exceed alarm level synchronously, LED status indication alternate every cycle. For example: If there is only one alarm, the REC LED blinks for one cycle and alarm LED will blink for next cycle. If there are two alarms, REC LED will not blink. First alarm will blink for first cycle and the next alarm will blink for next cycle. ****When the battery is low, all operations will be disabled automatically. NOTE: Logging automatically stops when the battery weakens (logged data will be retained). The supplied software is required to restart logging and to download logged data. ***** To use the delay function. Run the datalogger Graph software, click on the computer icon on the menu bar (2nd from left) or select LOGGER SET from the LINK pull-down menu. The Setup window will appear, and you will see there are two options: Manual and Instant. If you select the Manual option, after you click the Setup button, the logger won't start logging immediately until you press the yellow button in logger's housing.

SPECIFICATIONS Relative Humidity Overall Range 0 to 100% Accuracy (0 to 20 and 80 to 100%) ±5.0% Accuracy (20 to 40 and 60 to 80%) ±3.5% Accuracy (40 to 60%) ±3.0% Temperature Overall Range -40 to 70 C-40 to 158 F Accuracy (-40 to -10 and +40 to +70 C) ±2 Accuracy (-10 to +40 C) ±1 Accuracy (-40 to +14 and 104 to 158 F) ±3.6 Accuracy (+14 to +104 ) ±1.8 Dew point Temperature Overall Range -40 to 70 C -40 to 158 F Accuracy (25, 40 to 100%RH) ±2.0 (±4.0 ) Logging rate Selectable sampling interval: From 2 seconds up to 24 hours Operating temperature -35 to 80 C -31to 176 F Battery type Battery life Dimensions/Weight 3.6V lithium(1/2aa)(saft LS14250, Tadiran TL-5101 or equivalent) 1 year (typ.) depending on logging rate, ambient temperature & use of Alarm LEDs 101x25x23mm (4x1x.9 )/ 172g (6oz)

BATTERY REPLACEMENT Only use 3.6V lithium batteries. Before replacing the battery, remove the model from the PC. Follow diagrammatic and explaination steps 1 throught 4 below: 1. With a pointed object(d.g. a samll screwdriver or similar), open the casing. Lever the casing off in the direction of the arrow. 2. Pull the data logger from the casing. 3. Replace/Insert the battery into the battery compartment observing the right polarity. The two displays briefly light up for control purposes(alternationg, green, yellow, green). 4. Slide the data logger back into the casing until it snaps into place. Now the data logger is ready for programing. NOTE: Leaving the model plugged into the USB port for longer than necessary will cause some of the battery capacity to be lost. 1 2 3 4 WARNING: Handle lithium batteries carefully, observe warnings on battery casing. Dispose of in accordance with local regulations. Sensor Reconditioning Over time, the internal sensor may be compromised as a result of pollutants, chemical vapors, and other environmental conditions which can lead to inaccurate readings. To recondition the internal sensor, please follow the procedure below: Bake the Logger at 80 C (176 F) at<5%rh for 36 hours followed by 20-30 C (70-90 F) at>74%rh for 48 hour ( for re-hydration) If permanent damage to the internal sensor is suspected, replace the Logger immediately to insure accurate readings.