DeltaV Power Supplies

Similar documents
S-series DC to DC Power Supply

M-series MD Plus Controller

DeltaV SISnet Repeater

S-series SQ Controller

S-series Mass Connection Solutions

M-series FOUNDATION Fieldbus I/O

Power Supplies 3. SDN-P DIN Rail Series

S-series DeviceNet Interface Card

M-series Virtual I/O Module 2

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

CompactLogix Power Supplies Specifications

3500/62 Process Variable Monitor

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

RM4TG20 three-phase network control relay RM4-T - range V

DeltaV S-series Traditional I/O

Redundancy Module QUINT-DIODE/40

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Actuator-Sensor-Interface

Cisco Unified IP Phone Power Injector

Modular I/O System Analog and Digital Interface Modules

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

SYSTEM DESCRIPTION Termination Boards

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop

3500/25 Enhanced Keyphasor*Module

DeltaV Control Network Hardware

IMR 6000/10../20../30

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

STRATO LED Drivers 70W, Single output

Wireless Field Data Backhaul

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Power Supplies 3. SDN-C Compact DIN Rail Series

1756 ControlLogix Chassis Specifications

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Safety technique. Emergency stop module BO 5988 safemaster

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

3500/93 System Display

S-series Electronic Marshalling

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Telephone- and leased line modem for industrial applications TD-36

PHOENIX CONTACT Features

Electronic Control Devices The European Product Catalogue 2007

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Foxboro Evo Process Automation System

WD-AMX Water Detection Controllers

MCR1900 Media Converter 19-Slot Chassis

How To Protect Your Deltav Controllers From Cyber Attacks

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Chassis, Power Supply, and Element Management

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

Agilent 87421A/87422A Power Supply

NX safety stand-alone

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

3500/40M Proximitor* Monitor

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

LOGO!Power. Power supply. LOGO!Power. Overview. Safety instructions. Description, device design, dimension drawing. Mounting/disassembly

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Electronic Control Devices The European Product Catalogue 2007

SINEAX U553 Transducer for AC Voltage

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

BETA Protecting SITOR Semiconductor Fuses

Intersection Preassembled 19-inch Rack

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

MLC TM Maximum Productivity and Versatility for Control without Compromise!

1756 ControlLogix Power Supplies Specifications

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Preset Counter signo 721

Digital input modules

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

EGSTON Standard E2xFxWx 12W

Transcription:

December 2003 Page 1 Bulk AC to12 VDC power supply Bulk AC to 24 VDC power supply System power supply Control network Field wires Easy to use Flexible and cost-effective Secure Introduction Power your system won t operate without it. DeltaV power supplies offer you the most efficient and reliable power solution for your money. The DeltaV power supply suite provides power to the system electronics and to the field. This is all the power required for your DeltaV system. Benefits Easy to use. The system and passthrough power supplies are plug-and-play components. They fit into either position on the 2-wide power/controller carrier. The DeltaV power supplies are modular, easy to install, and secure. This carrier contains internal power buses, eliminating the need for external cabling to connect the system power supply to the DeltaV controller and I/O interfaces. The carrier mounts easily onto a T-type DIN rail easy! Flexible and cost-effective. The DeltaV power supply suite is modular. Add power to the field, controller and I/O subsystems as you need it. The power supplies load-sharing capabilities enable you to add more power or provide power redundancy to your system. Secure. Your I/O is always accurate because the I/O subsystem and controller always receive a consistent and accurate 12- or 5-VDC power supply. The power supplies are compliant with EMC and CSA standards; there is immediate notification of power failure; and system and field power provisions are completely isolated.

December 2003 Page 2 Product Description and Specification Two DeltaV system power supplies are available for use in your plant: the 115/220 VAC AC to DC system power supply and the 12/24VDC DC to DC system power supply. Plug-and play components. The system and passthrough power supply components fit into either position on the 2-wide power/controller carrier. This interchangeability means you can expand or replace power components. Just pull out one power supply component and snap in the other. 1 Rail mounted. Power supply installation is simple. Mount the 2-wide power/controller carrier into place on a T-type DIN rail. Then plug the system or passthrough power supplies into the carrier. Internal power bus. The 2-wide power/controller carrier contains internal power buses. You don t need to use external cabling to connect the system power supply to the DeltaV controller and the I/O interface carriers. Modular power. You know your power requirements today, but what about the future? Lay a solid foundation now and build on it later. A modular power structure allows you to simply snap on additional power to the field, controller, and I/O subsystems. You can add 2-wide power/controller carriers as you need them and install additional system power supplies. Accurate output. The system power supplies accept a wide range of power inputs and translate the inputs into accurate power output. Power redundancy. DeltaV system power supplies can be redundant at 1-to-N versus 1-to-1 in other systems. This provides an economical solution to creating system redundancy. No power overload. Distribution prevents power overloading on the I/O and 2-wide power/controller carriers. No more than 8 A can be carried on the backplane to the controller and the I/O subsystem. Standard compliance. The power supplies are compliant with EMC and CSA standards. Their design meets the new European power factor correction standards. No power degradation. The power supplies provide consistent power to the system and the field devices. No de-rating to the power supplies occurs when the temperature is within defined specifications. Immediate notification of power failure. Internal relay outputs change status and alert the user if the incoming voltage fails or if the system power supply fails. Also, the LED on the power supply housing displays the power status. System and field power isolation. The system and field power provisions are completely isolated. For example, if the Bulk AC to 24 VDC power supply providing power to the field fails, the system power supply (AC/DC) is unaffected. Power supply removal. You don t need to unscrew connections to remove the system power or the system passthrough power supplies. Simply unplug the connectors. Field power distribution to I/O interfaces. If multiple I/O modules in the same I/O subsystem need the same VDC to the field, you can wire the I/O modules together, creating a single power connection to the I/O interface carrier. 1 Refer to Zone 2 installation instructions (12P2046) and/or Class 1 Division 2 installation instructions (12P1293) for details.

December 2003 Page 3 AC/DC system power supply The system power supply directs DC power to the controller and I/O subsystem. It resides on either slot of the 2-wide power/controller carrier. Power is isolated from the field. Refer to Zone 2 installation instructions (12P2046) and/or Class 1 Division 2 installation instructions (12P1293) for information on installing in hazardous areas. Input Inrush (soft start) Description AC/DC System Power Supply Specifications 85 VAC to 264 VAC, 47 Hz to 63 Hz, single-phase 35 A peak maximum for one cycle or less at 230 VAC input Output power 25 W total at 60 C Output voltages +12 VDC at 2.1 A maximum +5 VDC at 2.0 A maximum +3.3 VDC at 0.5 A maximum Combined 5 VDC and 3.3 VDC output = 10 W maximum Input protection Internally fused, non-replaceable Overvoltage protection Output protected at 110 to 120% Hold-up time Operating temperature Storage temperature Relative humidity Airborne contaminants Hazardous areas Shock Vibration Mounting LED indicators Green AC power Red Error External connectors: Primary power Alarm contact Output: remains within 5% of nominal at full load and 155 VAC input for 20 ms 0 to 60 C (32 to 140 F) without derating -40 to 70 C (-40 to 158 F) 5 to 95%, non-condensing ISA-S71.04-1985 Airborne Contaminants Class G2 Class I, Div. II approval 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 Hz to 16 Hz, 0.5 g from 16 Hz to 150 Hz On either slot of 2-wide power/controller carrier Input AC power is applied and internal fuse is sound Outputs are not within ±4% of nominal (normal conditions). AC input: 3-wire 2-wire normally open relay; relay is closed when outputs are within ±4% of nominal; 2.0 A at 30 VDC, 2.0 A at 250 VAC

December 2003 Page 4 Redundant system power supply DeltaV controller 2-wide power and controller carrier AC/DC load-sharing or redundancy system power supply.

December 2003 Page 5 24/12 VDC System Power Supply This power supply accepts 12 or 24 VDC power and passes it to the 2-wide power/controller carrier. It resides on the power/controller carrier. System power is isolated from the field power supply. Input Inrush (soft start) Output power Description 24/12 VDC System Power Supply Specifications 11.4 to 12.6 (12 VDC Input) 21.6 to 26.4 (24 VDC Input) 12 A peak maximum for 5 ms over 12 VDC input range (excluding 12 VDC passthrough output) 20 A peak maximum for 5 ms over 24 VDC input range (including 12 VDC output) 10 W total at 60 C (combined outputs of 5 VDC and 3.3 VDC) Output voltages 13 A max (12 VDC Input) 12 VDC @ 4.5 A Max (if converted from 24 VDC) 2.0 A at +5 VDC 2.0 A at +3.3 VDC Input protection Internally fused, non-replaceable Overvoltage protection Output protected at 110% to 120% Hold-up time Operating temperature Storage temperature Relative humidity Airborne contaminants Shock Vibration Mounting Green DC Power Red Error Primary power Alarm contact LED Indicators: External connectors: Environmental Rating: Output: remains within 5% of nominal at full load and minimum input voltage for 5 ms (excluding 12 VDC current with 12 VDC input) 0 to 60 C (32 to 140 F) without derating -40 to 70 C (-40 to 158 F) 5 to 95%, non-condensing ISA-S71.04-1985 airborne contaminants class G3 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 Hz to 16 Hz, 0.5 g from 16 Hz to 150 Hz On either slot of 2-wide power/controller carrier Input DC power is applied and internal fuse/diode is sound. The +5 VDC and +3.3 VDC outputs are out of tolerance. DC input, 2-wire 2-wire normally open relay; relay is closed when 3.3 and 5 VDC outputs are within ±4% of nominal; 2.0 A at 30 VDC, 2.0 at 250 VAC FM Class 1 Div 2; Cenelec Zone 2 A, B, C, D T4 Hazardous locations ATEX 3 G IIC T4 -nc

December 2003 Page 6 Bulk Power Supplies The system bulk power supply provides a centralized power supply and distributes power to passthrough power supplies in various areas. The DeltaV bulk AC to 24 VDC power supply comes in a 300 W version. It converts 120/230 VAC power to 24 VDC power. The 24 VDC power provides power to the field devices via power distribution. Purchase off-the-shelf bulk power supply from Emerson Process Management. Or, use your own 12 VDC distribution network. One I/O interface carrier provides four power-input pairs for bussed field power. Refer to the I/O Interface Carrier product data sheet for specifications. AC input DC output voltage Description Bulk AC to 24 VDC Power Supply and Bulk AC to 12 VDC Power Supply Specifications 120/230 VAC nominal, 90 VAC to 264 VAC range, 47 Hz to 63 Hz, single-phase 24 VDC nominal 12 VDC nominal DC output power options 300 W at 60 C Inrush current Hold-up time 100/40A maximum (hot/cold start) 20 ms (from 90 to 264 VAC input) Output Overvoltage protection 125% (± 5%) Power factor Fuse protection Operating temperature Storage temperature Relative humidity Airborne contaminants Shock Vibration 0.98 at full rated load 10 A, 250 VAC 3AB or equivalent, non-replaceable fuse 0 to 60 C (32 to 140 F) at 300 W and altitude = 914 m (3000 ft) -55 to 85 C (-67 to 185 F) 5 to 95%, non-condensing ISA-S71.04-1985 airborne contaminants class G2 MIL-STD-810D Method 516.3, Procedure III MIL-STD-810D Method 514.3, Category 1, Procedure I Approvals CSA certified to C22.2 No. 234-950 UL recognized to UL 1950 TUV licensed to IEC 950, EN60950, FCC, VDE (Level B) CE certified to EN50081-1, EN50082-1 Meets IEEE 587 for input transients Dimensions Depth Width Height Weight Mounting options 39.37 cm (15.5 in.) 12.70 cm (5 in.) 6.35 cm (2.5 in.) 2.63 kg (5.79 lb) Wall mount or panel mount

December 2003 Page 7 Power Calculations System Power Supplies One AC/DC system power supply is sufficient for most DeltaV installations. The power supply provides 1.25 A. This is enough for: 20 discrete I/O cards 10 analog I/O cards Any combination of two discrete I/O cards to one analog I/O card to the limits listed above. One new 12/24-volt or one 12-volt DC/DC system power supply is sufficient for the maximum DeltaV subsystem size. Bulk Power Supplies for System Power The bulk AC to 12 VDC power supply and the bulk 24 VDC to 12 VDC power supply have the capacity to supply power to any single DeltaV system. However, if you are using the bulk power supply to provide power for more than one DeltaV system or for other equipment, please refer to the I/O card specifications. Bulk Power Supplies for Bussed Field Power The bulk AC to 24 VDC power supply provides power to field devices. In general, AI cards, AO cards, and dry contact DI cards use small amounts of current. The bulk AC to 24 VDC power supply provides enough power for approximately 40 of these types of I/O cards. If you are supplying power to I/O cards with high side switches, you must evaluate the power requirements carefully. Please refer to the manufacturer s specification for your field devices to determine the load.

December 2003 Page 8 Ordering Information Description Model Number 115/220 VAC AC to DC System Power Supply VE5001 24/12 VDC DC to DC System Power Supply VE5008 Bulk AC to 24 VDC Power Supply Bulk AC to 12 VDC Power Supply Bulk 24 VDC to 12 VDC Power Supply VE5003 VE5004 VE5005 To locate a sales office near you, visit our website at: www.easydeltav.com/reach or call us at: Asia Pacific: 65.777.8211 Europe, Middle East: 41.41.768.6111 North America, Latin America: +1 800.833.8314 or +1 512.832.3774 For large power, water, and wastewater applications contact Power and Water Solutions at: www.emersonprocess-powerwater.com Fisher-Rosemount Systems, Inc. 1996 2004 All rights reserved. or call us at: Asia Pacific: 65.777.8211 Europe, Middle East, Africa: 48.22.630.2443 North America, Latin America: +1 412.963.4000 DeltaV, the DeltaV design, SureService, the SureService design, SureNet, the SureNet design, and PlantWeb are marks of one of the Emerson Process Management group of companies. All other marks are property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice.