TANDEM DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE 830 TANDEM CLASS B TANDEM CLASS A PRESSURE REGULATOR OR GAS FLOW ADJUSTER

Similar documents
820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

System 8. ü ( System 8

Assisted lift operated 2/2-way solenoid valves Type EV250B

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

G670 Intermittent Pilot Ignition Controls

3/2-way Solenoid Valve, direct-acting, NC or NO

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

2/2 and 3/2 Way Size 6 Seat Valves

AGA GAS MARK 2 BURNER (CONVERSION) FITTING INSTRUCTIONS

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Spare Parts List M96A.24SM/B M96A.28SM/B

Electro-pneumatic control valves

VR46../VR86.. series COMPACT AUTOMATIC COMBINATION GAS CONTROLS APPLICATION. Contents PRODUCT HANDBOOK

HERZ-Thermal Actuators

TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/ kw GS20D 58/ kw

STC 3S A Series Solenoid Valves

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

4/2-Way Pneumatic Solenoid Valve

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Spare Parts List Activ A 12OV Activ A 15OV Activ A 20OV Activ A 25OV

Oil - kerosene burners

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

ELECTRIC CENTRAL HEATING FLOW BOILER

servo-controlled 3-WaY vacuum solenoid valves WiTH

Valves. Sub-Base Mounted Valves to ISO 5599/2

I D F GB E NL GS3 551T GS3 551T1

Hydraulic Control Solutions

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

4 Posiflow Proportional Solenoid Valves

Electric Rotary Actuator - On/Off or programmable control actuator

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

Proportional pressure regulators VPPE

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

3/2 Solenoid Cartridge Valve, Size 6

Mikrotherm. Manual radiator valves. To be precise.


Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Solenoid valves 2/2-way direct-operated Type EV210A

Chapter 5: Flow Valves

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Chapter 6: Check Valves

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

SOLENOID VALVES 3-4 WAY

INSTALLATION INSTRUCTIONS BL-8704

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

Cable Plug acc. to DIN EN , Form A

Please also see 10 golden rules for correct Saniflo installation on

INSTALLATION INSTRUCTIONS MK-8704

HEAVY DUTY STORAGE GAS

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2- and 2/2-way cartridge valve type BVE

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

RY2 miniature industrial relays

Pressure switches for gas and air Pressure sensors

Series description: Wilo-Drain TC 40

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

How To Use A Ds340 (Dsp)

OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.

G1/4 Q8. Standard with biased position

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

Quick Connect. quick - simple - efficient.

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Line-Mounted Valves L Series

Solenoid valves Type EVU

MODULATING LIGHT OIL BURNERS RL/M SERIES

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Weishaupt gas burners type G Gas/oil dual fuel burners types GL and RGL Sizes 1 and 3 1/2000 GB

Safety Manual BT50(T) Safety relay / Expansion relay

3/2-way Mini Solenoid Valve

MVX-Series Diesel Engine Air Shut Down Valves

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

! WARNING. Before using product, read and understand instructions.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

M A N U A L

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

RI27 CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

Coils - Connectors. Coils Connectors. Summary. RE / /10 Replaces: RE / Description

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS kw FS kw FS kw FS kw FS kw

Please keep this manual for f uture reference.

zamak nitrile rubber selfestinguishing technopolymer aluminum B10 24 V DC (± 10%) holding 0,32 W, pick-up 5,5 W (25 ms) IP65 button with tool

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Transcription:

SIT Group 830-83 TANDEM MULTIFUNCTIONAL GAS CONTROL DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE 830 TANDEM CLASS B - 83 TANDEM CLASS A PRESSURE REGULATOR OR GAS FLOW ADJUSTER ADJUSTABLE STEP IGNITION PIN 63AP7060/4

AUTOMATIC MULTIFUNCTIONAL CONTROL Multifunctional control with two automatic, near-silent, on-off valves: - 830 TANDEM in class B - 83 TANDEM in class A Pressure regulator or, alternatively, gas flow adjustment device. An adjustable-flow, step ignition device can be fitted on request. 830-83 TANDEM is suitable for installation on gas appliances fitted with automatic ignition and flame supervision systems, with or without intermittent pilot burner. MAIN FEATURES Two near-silent automatic shut-off valves: - 830 TANDEM: EV1 + EV in class B. - 83 TANDEM: EV1 + EV in class A. Pressure regulator C; alternatively, gas flow adjustment device. Adjustable flow step ignition device (optional). Pilot outlet (optional) with gas flow restrictor. Inlet and pilot filters. Inlet and outlet pressure test points. Threaded gas inlet and outlet with provision for flange connection. Connection for pressure regulator / combustion chamber compensation. Data refer to EN 16

DESCRIPTION 1 Shut-off solenoid valve EV1 Pressure regulator setting device, or, alternatively, outlet flow setting screw 3 Pilot gas flow restrictor 4 Step ignition flow adjustment screw 5 Inlet pressure test point 6 Outlet pressure test point 7 Shut-off solenoid valve EV 8 Pilot outlet 9 Main gas outlet 10 Holes (M5) for fixing flanges 11 Connection for pressure regulator / combustion chamber compensation 3 4 5 6 11 1 7 10 9 8 TECHNICAL DATA Gas connections: Rp 1/ ISO 7 Installation position: any position Gas families: I, II and III Maximum gas inlet pressure: 60 mbar Outlet pressure setting range: 3... 50 mbar (0... 50 on request) Working temperature range: 0... 60 C (-0... +60 on request) Pressure regulator: Class C Automatic solenoid valves 830 TANDEM Class B Automatic solenoid valves 83 TANDEM Class A ELECTRICAL DATA AUTOMATIC VALVES 830 TANDEM Class B 83 TANDEM Class A Voltage (AC) 30 V 50 Hz Consumption (ma) 80 Consumption (ma) 80 0 V 60 Hz 90-4 V 50 Hz 850 900 4 V 60 Hz 900-4 V 50 Hz Low Energy 500-4 V 60 Hz Low Energy 600 - Electrical protection rating IP54 with 150 type connectors. Data refer to EN 16

DIMENSIONS 33 5,5 1 1 4,5 48 108 11 30 86 14,5 17 Rp 1/ Rp 1/ 8 1 1 7,5 3 M4 65 14,5 17 5,5 5,5 96,5 105 FLOW RATE AS A FUNCTION OF PRESSURE DROP Q [m Q [m 3 /h, d=0.6] 3 /h gas, d=0.6] 8 Q [m 3 /h gas, d=0.6] 6 CLASS B+B 4 CLASS B+B I Family (d = 0.45) Q = 5.6 m 3 /h p = 5 mbar II Family (d = 0.6) Q =4.8 m 3 /h p = 5 mbar III Family (d = 1.7) Q = 6. kg/h p = 5 mbar 0 5 p p [mbar]

OPERATION Reading the inlet pressure The inlet pressure can be read at the pressure test point E with or without both automatic shut-off valves energized. Pilot burner ignition When the automatic shut-off valve EV1 is powered, it permits the gas to supply the pilot burner outlet (applications with intermittent pilot) after passing through the inlet filter, the pilot filter and the pilot flow rate restrictor (PILOT). Main burner ignition When both automatic valves, EV1 and EV, are energized, gas passage to the main burner is opened. Outlet pressure The outlet pressure is read at the test point A. PILOT E A EV1 EV REGULATED FLOW RATE IN ACCORDANCE WITH EN 88 Q [m Q 3 [m /h, 3 d=0.6] /h gas, d=0.6] 10 8 6 4 L H 0 4 6 8 10 1 14 16 Pu PU [mbar] CLASS B+B Inlet pressure range (mbar) Gas type Nominal Max. Min. H 0 5 17 L 5 30 0 Outlet pressure tolerance +10%...-15% STEP IGNITION Q max Qs Ignition gas flow as a function of time Maximum step ignition flow Qs as a function of the gas flow Q to the burner. Gas H Qs [m 3 /h] 3 tr Time Tempo (s) (s) 1 II Family III Family Step ignition time tr: 4 s 3 s Step ignition* reset time: 40 s (10 s on request) 0 1 3 4 5 6 Q [m 3 /h] *Reset time: time interval necessary for reactivating the step ignition device after solenoid valve closure.

INSTALLATION Main gas connection The connection is made using gas pipes with Rp 1/ ISO 7 threading. Torque: 5 Nm. If, alternatively, flanges (available on request) are used, first screw the pipes onto t he flanges and then the flanges to the valve. Recommended torque for the flange fixing screws: 3 Nm. Connection to the pilot burner Pipes with a 4 mm, 6 mm or 1/4 Ø can be used. Use a nut and olive of appropriate dimensions. Tighten to 7 Nm torque. CAUTION: if the pilot outlet is not used, seal it using the accessory, code 0.97.041. Torque: 7 Nm. Connection to the combustion chamber Pressure regulator / combustion chamber compensation is possible when the latter is pressurized (see figure). Use the special SIT hose connectors for this purpose. Torque: 1 Nm. Electrical connections Use the special connectors for the connection of the mains-powered versions. To ensure that the valve is connected to the earth circuit of the appliance it is necessary for the power connector, which includes the earth terminal, to be used at all times and secured by means of the associated screw. The 4Vac versions must be powered by means of an isolating transformer (with a very low safety voltage to EN 6074). Use terminals AMP 6.3 x 0.8 mm, DIN 4644 for the connection. Carry out the connections in accordance with the rules for the appliance. The electrical safety cut-off devices (for example, the flame supervision device, limit thermostat, and the like) must cut off the power supply to both safety solenoid valves simultaneously. CAUTION: after making the connections, check gas tightness and electrical insulation. A Connection to the combustion chamber

SETTINGS AND ADJUSTMENTS Measurement of the inlet and outlet pressure The inlet and outlet pressures of the gas can be measured by unscrewing the provided test point sealing screws. Replace screws with.5 Nm torque. Outlet pressure adjustment In versions with pressure regulator, screw in the adjustment screw (RP) to increase pressure; screw it out to reduce it. In versions with flow adjuster, screw in the adjustment screw (RQ) to reduce the pressure; screw it out to increase it. Overriding the pressure regulator In versions with pressure regulator, screw the adjustment (RP) screw fully in. Overriding gas flow-rate adjustment In versions with flow adjuster, un screw the adjustment screw (RQ) untill destop is reached. Gas flow-rate adjustment to the pilot (applications with intermittent pilot burner) Screw in the PILOT screw to reduce the flow or unscrew it to increase flow. Overriding gas flow-rate adjustment to the pilot (applications with intermittent pilot burner) It is sufficient to screw the PILOT screw in flush and then screw it out two complete turns. Step ignition flow adjustment Screw in the I STEP screw to reduce step ignition flow or unscrew it to increase flow. Changing the gas family or group Check suitability for use with the gas family or group of interest. Following the instructions given above, adjust the outlet pressure to the values indicated in the instruction booklet of the appliance. If required: override the pressure regulator and gas flow adjustment to the pilot. RP/RQ Outlet pressure adjustment I STEP PILOT CAUTION: Check tightness and efficiency and seal the adjustment devices. Implement the provisions in the Use and Maintenance manual - code 9.956.830 - for installation, adjustment and use Step ignition flow adjustment

830-83 TANDEM Multifunctional control with double solenoid valve: - 830 TANDEM in class B, - 83 TANDEM in class A, for gas appliances provided with automatic ignition and flame supervision devices. SIT La Precisa Viale dell'industria 31/33 3519 PADOVA - ITALY Tel. 049/893111 - Fax 049/8070093 - Telex 430130 SITEC I 9.955.985 R00 GRAPHIC DESIGN BY START - PD - ITALY