Viking. Pre-action Systems

Similar documents
BERMAD Fire Protection

TECHNICAL DATA. Dry 122a. November 12, 2013

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

BERMAD Fire Protection

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Pr o d u c t In f o r m at i o n V008.0

EXHIBIT A SCOPE OF WORK

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Sprinkler and Fire Alarm Systems for the Building Official

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting

Transformer Deluge Systems

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

PRESSURE REDUCING CONTROL VALVE

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Preaction System with DV-5 Deluge Valve Single Interlock, Supervised Wet Pilot Actuation 1-1/2 thru 8 Inch (DN40 thru DN200) General Description

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi CONTROL PANEL

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

ESFR "PRE-PRIMED SINGLE INTERLOCKED PREACTION" COLD STORAGE SYSTEM MANUAL

DV-5 Deluge Valve with Remote-Resetting, Pressure-Reducing Trim 4 Inch and 6 Inch (DN100 and DN150) General Description.

I-768 FireLock NXT Dry Valve

Inspection and Testing of Water-Based Systems

Foam Mixing Fire Suppression Package

Potter Electric Sprinkler Monitoring Training Manual

Morrison Bros. Co. General Product Specifications

Sprinkler Guards Model C Model D

FIVE YEAR CERTIFICATION REPORT

ENGINEERING SPECIFICATIONS

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Technical Data. Installation

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Automatic Fire Sprinkler Submittal Requirements

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

Fire Sprinkler Monitoring PRODUCTS. Accessories Alarm Bells Waterflow Detectors Pressure Switches Supervisory Switches Explosion-Proof

FIRE PROTECTION SYSTEMS ACCEPTANCE INSPECTION AND TESTING PROCEDURE

SPECIFICATION FOR A TOTAL FLOOD HFC-227ea CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE Cheetah Xi CONTROL PANEL SYSTEM

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

Release Control Fire Alarm Systems

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Sprinkler Monitoring & Releasing Systems

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

BERMAD Waterworks. High Pressure, Surge Anticipating Control Valve. 800 Series. Model 835-M. Features and Benefits. Major Additional Features

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

BASIC FIRE ALARM TRAINING

VSO MAX HP High Flow Proportional Valve

Series MJC Multiple Jet Controls DN20, DN25, DN40, and DN50, 12 bar BSPT Inlet & Outlets Threads General Description.

Wet alarm valves. Wet alarm valves. FM trim

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

University of Houston Master Construction Specifications Insert Project Name

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

TECHNICAL DATA. NOTES: For use with Trim Chart on page 27 b. (open fold-out)

TD01211 PIN: NX nd Edition. Water Motor Alarm MODEL: NX010 TECHNICAL DATA

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Diameter 3" 4" 6" 8" Flange type PN 16 PN 16 PN 16 PN 16. Orange-red ( RAL 2002) Height (cm) 27,70 26,30 28,

How To Control Water Flow

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

BERMAD Waterworks. Surge Anticipating Control Valve. 700 Series. Model 735-M. Features and Benefits. Major Additional Features

KODAK VERSAMARK, INC.

SECTION FIRE ALARM AND DETECTION SYSTEM

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

SECTION FIRE ALARM AND DETECTION SYSTEMS

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

FIRE ALARM SYSTEM RECORD OF COMPLETION

Automatic Control Valves

EFSN Training i Module Minutes

Instructions for Installation, Operation, Care and Maintenance

FIRE ALARM SYSTEM RECORD OF COMPLETION

Centro-Matic Automatic Lubrication Systems System Controls

AIR LINE VALVES AND GAUGES

FAIRBANKS NIJHUIS FIRE PUMPS.

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

Pilot Operated Pressure Reducing Valve PRV 47 (Steel) PRV47I (St.Steel)

Example. Fluid Power. Circuits

Fire detection, alarm, and suppression systems are installed to:

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

REGULATORS D& HD Series

Attachment 9. Trouble signals. Interfaced equipment. Primary (main) power supply

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

Commercial Semi-Instantaneous Water Heaters

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

AUTOMATIC CHANGEOVER MANIFOLD Series 915

Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container

Automatic Control Valves WATTS EU 100 Series

VFR-400 Installation, Operation, and Instruction Manual

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

SECTION FIRE PROTECTION PIPING SYSTEMS STANDARD CONSTRUCTION STANDARD PART 1: GENERAL

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Transcription:

Viking SureFire Pre-action Systems

Pre-action Systems Are: Fixed fire protection systems with CLOSED sprinklers connected to piping pressurized with air or nitrogen with a dependable water supply controlled by a normally closed Deluge Valve activated by a release system

Pre-action Systems Are Recommended : To prevent water damage due to mechanical damage to system piping. For hazards where fast application of water in fire conditions is important

SureFire Pre-action Systems Are: Operate in the same manner as standard pre-action. SureFire Pre-action provides the ability for the system to operate in the absence of power. Standard electric release preaction systems will not operate without power.

SureFire Pre-action Systems Are Recommended : Where Fail-Safe preaction is required, or where the power supply to the control panel cannot be depended upon.

SINGLE INTERLOCKED OPERATION The Release System must activate.. -(Detection ) Solenoid valve opens -(an alarm will sound) In fire conditions, -After the release system operates water travels from the Deluge Valve to the open sprinkler. -Upon sprinkler opening water flows from sprinkler orifice onto fire. Single interlock preaction does not have the water delivery delay that a double interlock preaction system has.

SYSTEM COMPONENTS

Pre-action System -Components Single Interlocked Sure-Fire Pre-action Sprinklers and Piping Release control panel Deluge Valve Deluge Valve trim System Control Valve Air Supply Riser Check Valve

Pre-action System -Components Sprinklers and Piping Deluge Valve Deluge Valve trim Double Interlocked Sure-Fire Pre-action System Control Valve Air Supply Riser Check Valve

Viking SureFire Release Trim Module To pressurized system piping Normally Open Solenoid Valve Normally Closed Solenoid Valve

VIKING DELUGE VALVES

Deluge Valves Deluge valves are held shut with pressurized water placed in the valve s priming chamber. The priming chamber controls a mechanism that keeps the deluge valve s clapper closed. The release system controls the water in the deluge valve s priming chamber. When the release system operates, the priming chamber is relieved of the priming water, allowing deluge valve clapper to open.

Deluge Valves The priming chamber has to be pressurized before the water control valve can be opened, allowing water pressure against the deluge valve clapper. A connection has to be placed before the water control valve, so the deluge valve can be primed. Once most deluge systems have operated, they have to be manually shut down before they can be put back in service.

Available 2 through 6 Listed at 250 PSI Viking Model E-1E Deluge Valve

Deluge Systems Bronze clamp ring EPDM rubber diaphragm EPDM & stainless steel seat rubber Bronze seat Teflon coated ductile iron clapper Ductile iron body

Deluge Systems Priming chamber Inlet chamber Discharge or outlet chamber

Deluge Systems

Deluge Systems

Deluge Systems

Deluge Systems

Deluge Systems

Deluge Systems

Deluge Systems

Deluge Valve: Model F-1

Model F-1 Deluge Valve

EZ DELUGE VALVE TRIM INSTALLATION & PURPOSE

Deluge Valve Install the Deluge Valve above a water supply control valve

Deluge Valve A flow test valve is connected to the inlet chamber of the deluge valve NFPA 25 (1992 ed) recommends Main Drain Test to be performed quarterly to determine if there has been a change in the water supply piping or control valves.

Deluge Valve Priming line

Deluge Valve Priming line Check valve Restricted orifice Strainer Priming valve (normally open) Connect priming line supply below water supply control valve

Deluge Valve Trim 1/16 Restricted orifice Spring loaded check ¼ Strainer ¼ Priming line ball valve

Deluge Valve Trim 1/16 Restricted orifice prevents the priming chamber from refilling at the same rate as the water is being released through the orifice of the releasing device

Deluge Valve Trim Auxiliary drain (normally Closed) Open to drain outlet & system piping after operation Trim piping connected to outlet chamber Drip check allows moisture to escape from outlet chamber. It seals against notched seat when outlet chamber is pressurized. To open drain cup

Deluge Valve Trim Alarm Connections ½ (15mm) NPT for alarm pressure switch ¾ (20mm) NPT for water motor alarm Viking drain check valve Alarm shut off valve (normally open)

Deluge Valve Trim Alarm test connections & supply pressure connections Water supply pressure gauge Alarm test valve (normally closed)

Deluge Valve Trim To release system Release connections & priming pressure gauge Emergency release Priming pressure gauge To open drain cup

Deluge Valve EZ Trim Prime Shut Off Valve (PSOV) PSOV Prime inlet To open drain cup

Deluge Valve Trim Drain loop To releasing device PSOV From releasing device To open drain cup

Viking PSOV (Prime Shut Off Valve) Eliminates the PORV and shuts OFF the water supply to the priming chamber

Deluge Valve and Trim The trim has been slightly modified to better view operating parts

Deluge Valve Trim To Release system When the hydraulic, electric, or pneumatic detection system has operated and the Viking deluge valve is tripped, the priming shut off valve (PSOV) is activated as shown in the following animation. WARNING!! Do not use this trim for any automatically resettable detection systems, or for pressure regulating valves! The trim has been slightly modified to better view operating parts

Deluge Systems To detection system The deluge valve will be tripped either: Pneumatically (by either pilot sprinklers or fixed temperature devices Hydraulically (by either pilot sprinklers or fixed temperature devices Electrically ( by smoke or heat detectors. Etc., that cause a solenoid valve to open.) The trim has been slightly modified to better view operating parts

Deluge Systems To detection system When the valve trips, water pressure from the discharge side of the valve will enter the sensing side of the PSOV forcing the clapper of the PSOV to close against the priming pressure, because of its mechanical advantage. The trim has been slightly modified to better view operating parts

Deluge Systems PSOV Operation

Deluge Systems PSOV Operation Priming the Deluge Valve

Deluge Systems PSOV Operation Priming the Deluge Valve

Deluge Systems PSOV Operation Priming the Deluge Valve

Deluge Systems PSOV Operation Priming the Deluge Valve

Deluge Systems PSOV Operation Deluge valve tripped, Shutting off priming water

EZ Deluge Trim UL Listed and FM Approved Stainless Steel Trim & Brass Trim also available

SureFire Release Systems Deluge valves are held shut by their release system. In a single interlocked SureFire pre-action system, we use one release module. We will discuss the SureFire release system as it pertains to the deluge valve and it s trim

Electric Release Electric release systems are the most prevalent type of release systems. Electric release offers the most flexibility, as the detection system can be configured in many ways, and the choices in release devices are greater than hydraulic or pneumatic.

Solenoid Valves Solenoid valves are described by their position when non-powered: 1) Normally Open When non-powered the solenoid valve is open 2) Normally Closed When non-powered the solenoid valve is closed

Viking SureFire Release Trim Module To pressurized system piping Normally Open Solenoid Valve Normally Closed Solenoid Valve

Viking SureFire Release Trim Module 24vdc Electric solenoid (normally open) 24vdc Electric solenoid (normally closed) Release Systems

Viking SureFire release trim module 24vdc Electric solenoid (normally open) 24vdc Electric solenoid (normally closed) Release Systems

SureFire Single Interlock Preaction Wiring Schematic Remote Trouble Signal Releaseing Circuit Solenoid One Release should be Normally Closed Releasing Circuit Solenoid Two Release should be Normally Open Alarm Bell

SureFire Single Interlock Preaction Wiring Schematic Detection circuit one Normally open detectors maximum loop resistance is 200 ohms System Two Air pressure supervisory switch System One detection circuit three (optional) WaterFlow switch circuit Detection circuit two closed pressure depends on water supply pressure (See Chart) Detection circuit four (supervisory circuit) closed pressure must be greater than the one from detection two plus 5 psi on pressure loss

SureFire Single Interlock Preaction Wiring Schematic Releaseing Circuit AC power Recommended pressure settings Ampmeter Jack Battery Jack Voltmeter Jack DIP switches See Function Table Stand by Batteries Stand by Batteries Recommended pressure settings Water Supply (psi) 0-100 100-200 200-250 Detection Circuit Two (psi) 15+ 25+ 35+ Detection Circuit Four (psi) 25 35 45 System Air (psi) 30 40 50

SureFire Single Interlock Preaction Wiring Schematic Par 3 Release Panel Function Table

SureFire Single Interlock Preaction Wiring Schematic 4-Wire Smoke Detector Connections To Detection input one

Viking SureFire Double Interlocked Pre-action

SureFire Double-Interlocked Pre-Action A second supervisory Switch is required for Double interlocked SureFire

DOUBLE INTERLOCKED OPERATION The Release System must activate.. -(an alarm will sound) -AND, -Pressure in the sprinkler piping must be reduced-(due to a sprinkler opening in fire conditions) To trip open the Deluge Valve. In fire conditions, - After the release system operates and the sprinkler opens, water needs to travel from the Deluge Valve to the open sprinkler. There may be a time delay similar to a Dry System.

DOUBLE INTERLOCKED OPERATION The Release System must activate.. -(an alarm will sound) -AND, -Pressure in the sprinkler piping must be reduced-(due to a sprinkler opening in fire conditions) To trip open the Deluge Valve. In fire conditions, - After the release system operates and the sprinkler opens, water needs to travel from the Deluge Valve to the open sprinkler. There may be a time delay similar to a Dry System.

DOUBLE INTERLOCKED OPERATION SureFire release trim is the same for either single or double interlocked pre-action. Double interlocked SureFire requires a second supervisory switch in the air supply line to the riser. The second supervisory switch operates the normally closed solenoid valve only after the detection circuit has operated. Both the detection and air pressure has to be lost prior to the normally closed solenoid operating.

Viking SureFire Release Trim Module To pressurized system piping Normally Open Solenoid Valve Normally Closed Solenoid Valve

SureFire Single Interlock Preaction Wiring Schematic Remote Trouble Signal Releasing Circuit Solenoid One Release should be Normally Closed Releasing Circuit Solenoid Two Release should be Normally Open Alarm Bell

SureFire Double Interlock Preaction Wiring Schematic Detection Circuit One Normally Open Detectors System Two Air Pressure Supervisory Switch System One Detection Circuit Three Waterflow Pressure Switch Detection Circuit Two closed pressure depends on water supply pressure Detection Circuit Four (Supervisory Circuit) Closed pressure must be greater than the one from detection circuit two

SureFire Single Interlock Preaction Wiring Schematic 4-Wire Smoke Detector Connections To Detection input one

SureFire Single Interlock Preaction Wiring Schematic Par 3 Release Panel Function Table

SureFire Single Interlock Preaction Wiring Schematic Relay contacts actuated by Detection Circuit input one or two or waterflow alarm switch, input three Supervisory switches, valve tamper, air pressure Etc. input four Detection Circuit Input one Remote Trouble Signal Detection circuit input two Detection circuit input one or two or waterflow alarm switch input three Panel malfunction or fault in field wiring

Thank You