Instruction Manual IM/LM_3. Field IT. Data Capture Utility. LogMaster



Similar documents
Electromagnetic Flowmeters

Field and Software Tools

Data Management Software

Setup guide IM/WM/VM EN Rev. B. VeriMaster Software tools

SMS Logger Server Software

CalMaster2 Field and Software Tools. The world's first battery- and mains-powered in situ flow verification system

Installation & Upgrade Guide. Hand-Held Configuration Devices Mobility DHH820-DMS. Mobility DHH820-DMS Device Management System Software

User Manual. Thermo Scientific Orion

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flow rates

Global Water Instrumentation, Inc.

GX-2009 Data Logger Management Program Operator s Manual

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

SMS Database System Quick Start. [Version 1.0.3]

Certificate of EC type-examination of a measuring instrument Number: UK/0126/0102

User s Manual. Management Software for ATS

TR-3 Channel Editor. Software Manual

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

Computer Lane Monitor for Windows

Configuring the Siemens TC35 modems for use with the MI2292

Welcome to MaxMobile. Introduction. System Requirements. MaxMobile 10.5 for Windows Mobile Pocket PC

RACEAIR REMOTE PAGER SYSTEM

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

PTR/DTR. Printing Thermometer Software. Software User Manual

Manual. Sealer Monitor Software. Version

IXP120 Alarm Monitor Utility

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7


Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

PARTNER ACS R4.0 Remote Administration R4.0. Getting Started

COMSPHERE 6700 SERIES NETWORK MANAGEMENT SYSTEM

ABUS WIRELESS ALARM SYSTEM

Service catalog Flow products

ScreenMaster RVG200 Paperless recorder FDA-approved record keeping. Measurement made easy

User Guide. Temperature and Humidity Datalogger. Model 42280

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

NortechCommander Software Operating Manual MAN R6

Modbus RTU (RS-485) TCP/IP (Ethernet)

PC Program User s Guide ( ) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

1000 Series Data Loggers PRODUCT MANUAL

AquaMaster Full bore and insertion meters. MagMaster Full bore and insertion meters. Aquaprobe Insertion flow meters

F453. TiF453. User guide 10/11-01 PC

Table of contents TABLE OF CONTENTS... 2 ABOUT THIS MANUAL... 3 IMPORTANT NOTES... 3 PICO LOGGING APPLICATION... 5 ABOUT THE PICO LOGGING PC

ERC-to-MRC JOB TRANSLATOR MANUAL

User s Manual for Fingerprint Door Control Software

Data Analysis Software

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration

Remote Access: Internet Explorer

ADP CollectAll Manager v2.4 User s Guide

GE Security. FHSD Monitor / Web Server user manual

SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards

T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: Version 1.0

OxySense Gen III Operations Manual

GPS Vehicle and personal location tracker. User manual

Hired-Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Part No Rev 6/02 Software Manual Farm Manager

BMV-602 Data Link Manual

Keep it Simple Timing

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

DTAP3000 DTSX3000 Control Visualization Software LAS2.0 Data Conversion Guide

SA-9600 Surface Area Software Manual

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

NDA ISSUE 1 STOCK # CallCenterWorX-Enterprise IMX MAT Quick Reference Guide MAY, NEC America, Inc.

Sentry4 NJEX Odorant System Software Operators Manual. Remote operation Documented audit trail Analyzing and reporting graphs

SAP BusinessObjects Financial Consolidation Web User Guide

Config software for D2 systems USER S MANUAL

Dominion KX II-101-V2

AquaMaster 3 flow measurement Saving every drop of energy and cost naturally!

EGCP-3 LS Revision L. Explanation of Software Changes Made for the EGCP-3 LS Control. Application Note 51294

Call Recorder Apresa User Manual

User's Reference Guide for PowerAlert UPS Management Software Version 10.2 for Windows

Amcrest 960H DVR Quick Start Guide

File Management Utility User Guide

DSG SoftPhone & USB Phone Series User Guide

Real Time Monitor. A Real-Time Windows Operator Interface. DDE Compliant. (for remote data display)

EnergySmart monitor user instructions

Geotech AEMS Data Centre User Guide

AEI RAIL NETWORK SERVER User Manual

MyFaxCentral User Administration Guide

A-Series Data Loggers PRODUCT MANUAL

GV-Data Capture V3 Series User's Manual

Korosi Monitoring System (KMS) Software Manual

DriveRight. Fleet Management Software. Getting Started Guide. CarChip. DriveRight. Drivers. Vehicles. Product #8186

Lifecycle Service Tool. Operator's manual

KM Metering Inc. EKM Dash User Manual. EKM Metering Inc. (831)

Monitoring the autoclaving process in the pharmaceutical industry

HP LaserJet MFP Analog Fax Accessory 300 Send Fax Driver Guide

Device configurator DRC200

Virtual CD v10. Network Management Server Manual. H+H Software GmbH

PDA Software Manual For the Windows CE and Mobile Operating Systems

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

GV-Keyboard. User's Manual V2.0

Cyberex BCM-SFCM Configurator/Monitor User's Manual

Hydras 3 LT Quick Start

USB Driver INSTALLATION GUIDE 6 NOVEMBER 2013 RIGHT SOLUTIONS RIGHT PARTNER D B

NOTE: LakeMaster charts purchased from chartselect.humminbird.com do not need to be registered.

Welcome to MaxMobile. Introduction. System Requirements

Transcription:

Instruction Manual IM/LM_3 Field IT Data Capture Utility LogMaster

ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. The quality, accuracy and performance of the Company s products result from over 100 years experience, combined with a continuous program of innovative design and development to incorporate the latest technology. The UKAS Calibration Laboratory No. 0255 is just one of the ten flow calibration plants operated by the Company, and is indicative of our dedication to quality and accuracy. EN ISO 9001:2000 RE GISTERED Cert. No. Q5907 EN 29001 (ISO 9001) Lenno, Italy Cert. No. 9/90A Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of the Technical Publications Department. Health and Safety To ensure that our products are safe and without risk to health, the following points must be noted: 1. The relevant sections of these instructions must be read carefully before proceeding. 2. Warning labels on containers and packages must be observed. 3. Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and in accordance with the information given. 4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure and/or temperature. 5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. Normal safe handling procedures must be used. 6. When disposing of chemicals ensure that no two chemicals are mixed. Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets (where applicable) may be obtained from the Company address on the back cover, together with servicing and spares information.

CONTENTS 1 INTRODUCTION... 1 2 PREPARATION... 2 2.1 Installing the LogMaster Software... 2 2.2 Connecting a Computer to a Transmitter... 2 2.2.1 Configuring the PC Comms Ports... 2 3 OPERATION... 3 3.1 Starting LogMaster... 3 3.2 The Menus Overview... 3 3.2.1 The Drop-Down Menus... 3 3.2.2 Changing Logger Access Passwords... 4 3.2.3 The Tool Bar Buttons... 5 3.3 Using the Address Book... 6 3.4 Logger Access... 7 3.4.1 Display Data... 8 3.4.2 Change Flow Units... 8 3.5 The Status Bar... 8 1 INTRODUCTION LogMaster is a data capture utility for retrieving log data and device information from ABB AquaMaster water meters. It currently supports direct connection to the AquaMaster and remote connections via modem (GSM enabled AquaMasters only) or Vodafone Paknet Radiopad (Paknet AquaMaster installations only). Log data from the AquaMaster can be saved in comma-separated variable (CSV) format for importing into other applications. For example, spreadsheets for graphing purposes. When requesting log data, LogMaster can be configured to: reset the flow/pressure loggers, reset the flow/pressure loggers with a new logging interval, synchronize the AquaMaster s time and date with that of the PC. LogMaster is compatible with Windows 98 TM, NT TM and Windows 2000 TM. 1

2 PREPARATION 2.1 Installing the LogMaster Software Insert the CD and use the Windows software installation facility to load the LogMaster program. Follow the on-screen instructions. 2.2 Connecting a Computer to a Transmitter Fig. 2.1 Refer to Fig. 2.1 for direct connection to the AquaMaster Transmitter. For remote connections, connect a PC comm port to the connection hardware (modem, GSM terminal, radiopad etc). 2.2.1 Configuring the PC Comms Ports 1) From Comms drop-down menu (see Section 3.2.1) set the Remote Connection Port comm port setting to which the modem or radiopad is connected. 2) Set Direct & Terminal Mode Port to the port number to be used for direct connections or in terminal mode. Metal AquaMaster Transmitter Plastic AquaMaster Transmitter Original Style (requires Laplink Lead - supplied) Current Style ABB Part No. WEBC2000 9-pin female plug connected to serial data socket on PDA or PC Fig. 2.1 Connecting PC to Transmitter 2

3 OPERATION 3.1 Starting LogMaster Select LogMaster from the program menu and the Main Menu is displayed. Windows commands and conventions apply. To ensure that all the data can be seen, maximize the window. 3.2 The Menus Overview The main menu is structured as illustrated below. The Tool Bar, Dialog Bar and Status Bar may be hidden or displayed using switches in the View menu. Tool Bar Dialog Bar Data Display Area Status Bar 3.2.1 The Drop-Down Menus These contain all of the functions. For convenience, commonly required functions are presented as buttons on the Tool Bar see section 3.2.3 for a descrition of each button. 3

3 OPERATION 3.2.1 The Drop-Down Menus Note. Terminal Mode Baud Rate should be set to 4800 for direct connections. 3.2.2 Changing Logger Access Passwords 16 characters maximum Note. The password is used to access the AquaMaster logger. Needed for logger data or header requests. 4

3.2.3 The Tool Bar Buttons The function of each active button is displayed when the pointer rests over it and are further expanded on the Status Bar. Tool Tips also pop up by the buttons if the mouse pointer rests over the button for one second. The function of each relevant button on the Tool Bar is defined below. 3 OPERATION Press to cut connection (hang up). This can be done at any time except during a request. Press to get and display current system AquaMaster version. Press to get logger data. Time span or Record Serial number (RSN) range is achieved by setting parameters in the displayed dialog see 3.4. Requires AquaMaster logger access password else request will fail. Press to activate terminal mode. This locks open a channel to an allocated comms port. Connection timer also starts. There is now direct access to the AquaMaster menu handling system if connected directly. For modem or radiopad communication, manually dial (using AT commands for modem connections) or press dial button if the target site is displayed in the Site window. Press to dial and connect to displayed site. Option only available for modem or radiopad sites. See section 3.3.1. Press to get and display DIB = Device Information Block. Press to get and display logger header data only. This feature is password protected. Choose an appropriate logger, 1, 2 or 3, from the displayed menu. Press to display stored data from previous use of Logger button. Displays status information of last log retrieved. Press to stop current request. Press to display stored DIB from previous use of DIB button. Press for Totaliser (if data has been retrieved from logger 3). Display LogMaster information. 5

3 OPERATION 3.3 Using the Address Book 1 Press to select from drop-down list of sites Press for Locations Editor (see 2 below) 2 Press to remove an existing site address Press for Insert New Location 3 Enter details in each of the fields as required. Press to modify existing entry details 32 characters maximum Site's phone number (modem connections) or NUA (radiopad connections). Disabled for direct connections. Selection of connection type: DIRECT, MDEM, RPAD. 6

3 OPERATION 3.4 Logger Access Press Set up the parameters (see below) to suit. Select the logger to: 1, 2 or 3 Loggers 1 and 2 are flow/pressure loggers. Logger 3 is the Totalizer log. Time synchronization with the PC. Select: Before, After, None Before means synchronize before download After means synchronize after download None means no time synchronization. Select method of data collection. This function is disabled if Last or All Data is selected below. Set up date/time range. Point to highlight date/time elements for changing. If RSN* is selected, then these will be the start/end RSN. 13 If you want the previous hours only, this box and specify how many. Disabled if All Data selected below. ** to retrieve all data in selected logger. * RSN is the Record Serial Number which is unique to each log entry. ** Unavailable if logger 3 is selected. New logging interval after logger reset. to apply new settings after logger reset. to reset the logger - this deletes all logger records. Press OK to retrieve the data. If a prompt for the AquaMaster password is displayed, enter the AquaMaster level 4 password see also Section 3.2.2 to change passwords. 7

3 OPERATION 3.4.1 Display Data Use the buttons on the Tool Bar (shown below) to display the logger data. Press to display stored DIB from previous use of DIB button. Press to display stored data from previous use of Logger button. Press for Totaliser (if data has been retrieved from logger 3). Displays status information of last log retrieved. Press to stop current request. Display LogMaster information. 3.4.2 Change Flow Units Press the down arrow on the Dialog Bar and select from the drop-down list. 3.5 The Status Bar Current activity Site ID Current port Activity progress 8 Communication method (DIRECT, MDEM or RPAD) If modem or radiopad site, phone number or NUA is displayed.

PRODUCTS & CUSTOMER SUPPORT Products Automation Systems for the following industries: Chemical & Pharmaceutical Food & Beverage Manufacturing Metals and Minerals Oil, Gas & Petrochemical Pulp and Paper Drives and Motors AC and DC Drives, AC and DC Machines, AC motors to 1kV Drive systems Force Measurement Servo Drives Customer Support We provide a comprehensive after sales service via a Worldwide Service Organization. Contact one of the following offices for details on your nearest Service and Repair Centre. United Kingdom ABB Limited Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671 United States of America ABB Inc Tel: +1 215-674-6000 Fax: +1 215-674-7183 Controllers & Recorders Single and Multi-loop Controllers Circular Chart, Strip Chart and Paperless Recorders Paperless Recorders Process Indicators Flexible Automation Industrial Robots and Robot Systems Flow Measurement Electromagnetic Flowmeters Mass Flow Meters Turbine Flowmeters Flow Elements Marine Systems & Turbochargers Electrical Systems Marine Equipment Offshore Retrofit and Refurbishment Process Analytics Process Gas Analysis Systems Integration Transmitters Pressure Temperature Level Interface Modules Valves, Actuators and Positioners Control Valves Actuators Positioners Water, Gas & Industrial Analytics Instrumentation ph, conductivity, and dissolved oxygen transmitters and sensors ammonia, nitrate, phosphate, silica, sodium, chloride, fluoride, dissolved oxygen and hydrazine analyzers. Zirconia oxygen analyzers, katharometers, hydrogen purity and purge-gas monitors, thermal conductivity. Client Warranty Prior to installation, the equipment referred to in this manual must be stored in a clean, dry environment, in accordance with the Company's published specification. Periodic checks must be made on the equipment's condition. In the event of a failure under warranty, the following documentation must be provided as substantiation: 1. A listing evidencing process operation and alarm logs at time of failure. 2. Copies of all storage, installation, operating and maintenance records relating to the alleged faulty unit.

ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB 2004 Printed in UK (09.04) IM/LM Issue 3 ABB Limited Oldends Lane, Stonehouse Gloucestershire, GL10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 827856 ABB Inc 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215-674 7183