NFPA 285: Fire Testing of Exterior Wall Assemblies Containing Combustible Components. Maria Spinu, PhD, LEED AP DuPont Building Innovations

Similar documents
From the popularity of building

Continuous Insulation Using Polyiso Wall Sheathing

Meeting the Fire Code with Continuous Foam Plastic Insulation

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Fire Testing of Recycled Materials for Building Applications

Underwriters Laboratories Testing Information

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2C Energy & IAQ (2013) Related TEK: 2-5B, 6-1C, 6-4B, 6-11A, 6-12C, 6-12D, 6-12E

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

The Case for Cross Laminated Timber: Part 2

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

Fiberglas, Exterior Wall Thermal Insulation

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Fire Barriers & Fire Stopping

CommercialComplete Wall System NFPA 285 Tested Wall Assemblies

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Tremco Fire Protection Systems Group Technical Bulletin

03/05/14 REVISOR RSI/JC RD3945

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Wood use in Type I and II (noncombustible) construction

Fire-Rated Glass and Glazing START

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

2014 British Columbia Building Code Changes

Fire testing for BCA compliance

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

Fire Resistance of Brick Masonry

COMMERCIAL BUILDING APPLICATIONS

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

Avoiding Air Barrier Pitfalls

2009 IECC Update. Scope. Content. International Energy Conservation Code

Building Code Clarifications - 7. Fire Resistance

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

EcoTouch Insulation with PureFiber Technology

FIRE-RESISTANCE RATINGS WITH STEEL JOISTS

R-VALUES AND U-FACTORS OF SINGLE WYTHE CONCRETE MASONRY WALLS. TEK 6-2B Energy & IAQ (2009) Related TEK: 6-1B, 6-11, 6-12C INTRODUCTION

Building Envelope Design. ComfortBoard IS. Exterior Insulated Sheathing for High-Performance Residential Wall Systems

Polyurethane Products

R-Value and Densities Chart

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Fire or Ignition Resistant? Building Materials & Vegetation

ISO Types 1-6: Construction Code Descriptions

CHAPTER 7: Building Systems ROOFING SYSTEMS

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

NC Rehab Code Case Study Cheerwine Building January 17, 2002; rev 4/12/02

Comment Form on Proposed Gut Rehabilitation Alternatives

Performance of 8 Passive House Envelopes in Cold Climates

Insulating Basements: Part 3 Basement Wall Systems

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ICYNENE, INC.

Class Number May FM Approvals LLC. All rights reserved.

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

Product Guide Specification

Excerpts from the Canadian National Building Code (NBC)

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

Heating Load Calculation

From Wired Glass to Clear Solutions: Designing with Fire Rated Glass Today

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Commercial Wall Designs using Continuous Insulation (CI) under Cladding BCBEC Vancouver and Victoria May 25 th & 26 th, 2011

DESIGN GUIDE. Thermal Design and Code Compliance for Cold-Formed Steel Walls Edition

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

Terms and Definitions In Canada

PB301 July Lightweight Building Solutions. Bushfire Protection.

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

DEFAULT HEAT LOSS COEFFICIENTS

Insulation R-Value Comparisons

Approval Standard for Class 1 Fire Rating of Building Panels or Interior Finish Materials

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

Scottsdale, Arizona. Presentation by: Hermes Norero, P.E. President and CEO

Water Vapor Permeance of Wood Structural Panels and Wood Wall Construction

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

A ROAD MAP FOR YOUR CODE, SMOKE BARRIER & SMOKE PARTITION REQUIREMENTS

In accordance with NFPA 30, these containers are not to store Class I flammable liquids.

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

FIRE-RESISTANCE-RATED CONSTRUCTION

Fire-Retardant-Treated (FRT) Plywood

FIRE AND SMOKE PROTECTION FEATURES

Pyroguard Wired Glass

FIRE-RESISTANCE-RATED CONSTRUCTION

Transcription:

NFPA 285: Fire Testing of Exterior Wall Assemblies Containing Combustible Components Maria Spinu, PhD, LEED AP DuPont Building Innovations

AIA/CES LU Learning Objectives 1. Understand fire performance requirements in International Building Code (IBC) 2. Learn about fire related tests referenced by IBC 3. Understand NFPA 285 wall assembly testing 4. Understand which assembly components trigger NFPA 285 testing 5. Understand how to determine if your assembly requires NFPA 285 testing 6. Learn about potential alternative options to address compliance with NFPA 285

Section 1: Understand International Building Code Requirements for Fire Performance

SECTION 1 Construction Types (IBC Ch. 5, 6) (Table 601 lists the fire resistant rating requirements for building elements, in hours) Combustible Type V: Combustible Construction Non- Combustible Type IV: Non-Combustible Exterior Walls/ Combustible interior structural frames Type III: Non-Combustible Exterior Walls/ Combustible interior structural frames Type II: Non-Combustible Structure Type I: Non-Combustible Structure Each Type has an A and a B sub-category; A has increased fire protection requirements (see example below): Type I-A: 3-hr rated structural frame Type I-B: 2-hr rated structural frame Type II-A: 1-hr rated structural frame Type II-B: unprotected structural frame

SECTION 1 NFPA 285 Definitions 3.3.2 Combustible (Material). A material that, in the form in which it is used and under the conditions anticipated, will ignite and burn; a material that does not meet the definition of noncombustible or limited-combustible. [5000, 2012] 3.3.5 Noncombustible Material. A material that, in the form in which it is used and under the conditions anticipated, will not ignite, burn, support combustion, or release flammable vapors when subjected to fire or heat. Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C, shall be considered noncombustible materials. 3.3.4 Limited-Combustible (Material). Refers to a building construction material not complying with the definition of noncombustible material that, in the form in which it is used, has a potential heat value not exceeding 3500 Btu/lb (8141 kj/kg), when tested in accordance with NFPA 259, Standard Test Method for Potential Heat of Building Materials,...etc...

SECTION 1 Construction Types Examples http://desource.uvu.edu/ctc/iaco/iaco_01.php Fitzgerald's Heavy Timber Construction, Inc., 2006 Mark Martin @ http://www.houstonrealestateobserver.com Type V Type IV Type III Type I Type II Wikimedia Commons, Daniel Schwen Firefightersenemy.com, dc802

SECTION 1 Maximum Building Height (IBC Table 503) Type V Type IV Type III Type II Type I Including 1-story sprinkler system increase* Building Use Combustible Heavy Timber Non-Combustible Exterior Residential (IRC) Non-Combustible Components Fire-Rated Structure Type V Type IV Type III Type II Type I Type V Type IV Type III Non-Combustible Type II Fire-Rated Type I Combustible Heavy Timber Non-Combustible Combustible Heavy Timber Non-Combustible Exterior Residential 3 n/a n/a n/a n/a Non-Combustible Components Components Fire-Rated Structure Structure Building Use Residential Commercial** (IRC) (IBC) Exterior Residential Assembly*** Building Use Residential 3 (IRC) n/a 4 n/a 4 n/a 4 Unlimited n/a Education Residential 23 n/a 4 n/a 4 n/a 4 Unlimited n/a Building Use Commercial** (IBC) Assembly*** Business Building Use Commercial** 3 4 (IBC) 4 6 4 6 4 6 Unlimited Unlimited Education Factory/Ind Assembly*** 2 43 64 54 64 Unlimited Business High Education Hazard 4 2 6 4 6 4 6 4 Unlimited Factory/Ind Institutional Business 34 56 5 6 56 Unlimited High Mercantile Factory/Ind Hazard 4 56 6 5 56 Unlimited Institutional Residential High Hazard 3 4 5 6 5 6 5 6 Unlimited Mercantile Storage Institutional 4 53 65 5 65 Unlimited Residential Utility Mercantile 34 5 45 5 Unlimited Storage Residential 54 65 5 65 Unlimited Utility Storage 35 56 45 56 Unlimited * Where a building is equipped with an approved automatic sprinkler system the maximum number of stories is increased by one Source: 2012 International Building Code

SECTION 1 IBC Fire Related Tests and Reports Product Properties ASTM E84 Surface Burning Characteristics ASTM E1354 Cone Calorimeter Test ICC ES Reports (compliance aid, not a test method) Assembly Properties ASTM E 119 or UL 263 Fire Rated Walls NFPA 268 Radiant Ignitibility of Assemblies NFPA 285 Walls With Combustible Components

SECTION 1 What is NFPA 285? Test of the actual wall assembly is generally required when noncombustible walls contain combustible materials Is not new, but awareness has increased due to code changes In high-rise buildings: Assembly fire performance is critical for evacuation and life safety. www.bfm.co.th/index.php?m=product&a=index&lang=en www.bfm.co.th/index.php?m=product&a=index&lang=en 9

SECTION 1 History of NFPA 285 Energy Crisis: Leads to increased exterior insulation applications 1988: Uniform Building Code adopts UBC 17-6 1997: Uniform Building Code adopts UBC 26-9 2000: IBC begins requiring NFPA 285 testing 1970 s 1980 s 1990 s 2000 s 2010 s Late 70 s: SPI develops full-scale test 1998: NFPA adopts UBC 26-9 as NFPA 285 2012: IBC expands NFPA 285 testing to WRB Full-scale Fire Test UBC 17-6 / UBC 26-4 Reduced-scale Fire Test UBC 26-9 / NFPA 285 Source: NFPA 285: What you Need to Know by Jesse J. Beitel JBED Summer 2012 issue

SECTION 1 IBC NFPA 285 Testing - Material Triggers Foam Plastic Insulation (Ch. 26) Applies to Type I IV construction (~1988) Applies to buildings of any height Combustible Exterior Cladding (Ch. 14) EIFS - (~2000 IBC) MCMs - (~2003 IBC) FRPs - (~2009 IBC) HPLs - (~2012 IBC) REQUIRED Water-Resistive Barriers (Ch. 14) Applies to Type I, II, III, IV buildings over 40 ft Applies to combustible WRB s - (2012 IBC)

Section 1: Understand International Building Code Requirements for Fire Performance

Section 2: Wall Configuration and Performance Parameters for Assembly Testing

SECTION 2 NFPA 285 Multi-Story Test 2 Story Test with Interior & Exterior Burners Architectural Testing, Inc. Informational Bulletin # 61 17.5 ft high 13.3 ft wide (5.3 m high 4.1 m wide)

SECTION 2 NFPA 285 Fire Test - Components 6 Concrete Slab 2 nd Floor Room Test Wall Assembly 18 0 Tall Min x 13 4 Wide Min CMU Walls 8 Concrete Slab 1 st Floor Room Room Burner 6 Concrete Slab 78 Wide Window Opening Window Burner

SECTION 2 NFPA 285 Fire Test Parameters (Flame Spread) No flame propagation into the 2 nd floor room 10.2.5. Flames in Second-Story Test Room. Flames shall not occur in the second-story test room.

SECTION 2 NFPA 285 Fire Test Parameters (Flame Spread) Externally, Flames shall not reach 10 ft. above the window s top Externally, Flames shall not reach 5 ft. laterally from the window s centerline

........ SECTION 2 NFPA 285 Fire Test Parameters (Max. Temperature) Thermocouples inside wall assembly shall not exceed 1000 ºF during the test.

Section 2: Successful Assembly Performance: Test Configuration and Required Parameters

Section 3: Combustible Components in an Exterior Wall intended for Noncombustible Construction

SECTION 3 Building Envelope Assembly Components Interior Drywall Vapor Barrier* Cavity Insulation Base Wall Structure Exterior Sheathing Air & Water Barrier Exterior Insulation Exterior Cladding * Vapor Barrier s use and location in the wall is climate specific

SECTION 3 IBC NFPA 285 Requirements -- Triggers Foam Plastic Insulation Combustible Claddings (EIFS, MCM, FRP, HPL) Air & Water Barriers (WRBs) Installations over 40 (Type I, II, III, or IV) Foam Plastic and Foam Plastic core materials

SECTION 3 IBC Combustible Component Requirements Air & Water Barriers (WRBs) 1403.5 (2012) Combustible Claddings EIFS - 1408.2 (2000) MCM - 1407.10 (2003) FRP - 2612.5 (2009) HPL - 1409.10 (2012) Foam Plastic Insulation 2603.5.5

SECTION 3 IBC NFPA 285 Testing Requirements Is FOAM PLASTIC Insulation in the exterior wall assembly? YES REQUIRED NO YES Non-Combustible Construction Types I, II, III, or IV? Is EXTERIOR CLADDING Combustible? NO AND Installed greater than 40 above grade YES (Per Commercial Building Code, IBC) NO Is WRB* Combustible? NO AND Installed greater than 40 above grade *PER 2012 IBC REVISION, EXCEPTIONS APPROVED FOR 2015 IBC RELEASE YES NFPA 285 Compliance NOT REQUIRED

SECTION 3 IBC Combustible Component Requirements Foam Plastic Insulation Combustible Claddings (EIFS, MCM, FRP, HPL) Air & Water Barriers Material Requirements, IBC Type I-IV Taller than 40 Products are Labeled and Identified by manufacturer Flame Spread Index 25 (ASTM E84) Class A Smoke Development Index 450 (ASTM E84) Maintain assembly fire rating (ASTM E119 or UL 263) Separated from interior by a Thermal Barrier (gyp. board)

SECTION 3 NFPA 285 Wall Assembly: Exterior Insulation Air & Water Barriers 1403.5 Combustible Claddings EIFS - 1408.2 MCM - 1407.10 FRP - 2612.5 HPL - 1409.10 2603.5.5

SECTION 3 Climate Zones & Continuous Insulation Requirements Increasing Mandatory use of Continuous Insulation (ci) in EVERY climate zone ASHRAE 90.1 2010 2013

24 o.c. 16 o.c. SECTION 3 Impact of Thermal Bridging on Effective Installed R-Value for Steel-Framed Walls

SECTION 3 NFPA 285 Wall Assembly: Exterior Insulation Common Insulation Types Glass Fiber Batt R-value: ~3.3 R/in Permeability: 118 perm-in Spray Polyurethane Foam R-value: ~6 R/in (high density)* Permeability: ~1.9 perm-in EPS (Expanded Polystyrene) R-value: ~4 R/in Permeability: ~2.7 perm-in XPS (Extruded Polystyrene) R-value: ~5 R/in Permeability: ~0.8 perm-in Polyisocyanurate R-value: ~6 R/in Permeability: ~0.75 perm-in Mineral Fiber R-value: ~4 R/in Permeability: ~54 perm-in Source: 2009 ASHRAE Handbook-Fundamentals, * 1997 ASHRAE Handbook-Fundamentals

SECTION 3 NFPA 285 Wall Assembly: Combustible Claddings Air & Water Barriers 1403.5 EIFS - 1408.2 MCM - 1407.10 FRP - 2612.5 HPL - 1409.10 Foam Plastic Insulation 2603.5.5

SECTION 3 NFPA 285 Wall Assembly: Exterior Cladding COMBUSTIBLE Exterior Insulation Finishing Systems (EIFS) Metal Composite Materials (MCMs) Fiber Reinforced Plastics (FRPs) High Pressure Laminates (HPLs) NON-COMBUSTIBLE Brick / Masonry / Stone / Terracotta Concrete / Cementitious Stucco Fiber Cement Boards / Panels

SECTION 3 NFPA 285 Wall Assembly: Exterior Cladding Exterior Insulation Finishing Systems (EIFS) - - 1408.2 IBC regulates under Foam Plastic Requirements 1408.2: Meet the EIFS performance requirements of ASTM E2568 Metal Composite Materials (MCMs) Fiber Reinforced Plastics (FRPs) High Pressure Laminates (HPLs)

SECTION 3 NFPA 285 Wall Assembly: Exterior Cladding Exterior Insulation Finishing Systems (EIFS) Metal Composite Materials (MCMs) - 1407.10 Excludes Foam Plastic core materials Different core materials have different fire performance characteristics Available in Open and Closed Joint Systems Approximate 4mm-12mm panel thickness 1407.10.4. Comply with NFPA 285 acceptance criteria. Full-scale tests... performed with the MCM in the max. thickness intended for use Fiber Reinforced Plastics (FRPs) High Pressure Laminates (HPLs)

SECTION 3 NFPA 285 Wall Assembly: Exterior Cladding Exterior Insulation Finishing Systems (EIFS) Metal Composite Materials (MCMs) Fiber Reinforced Plastics (FRPs) 2612.5 Foam cores comply with Foam Plastic Req s Surface Burning Characteristics: Flame Spread Index 75 and smoke-developed index 450 (ASTM E84) Installations less than 40 above grade http://www.cranecomposites.com Limited to 10% area when separation <10 Flame Spread Index 200 (ASTM E84) Fireblocking Required High Pressure Laminates (HPLs)

SECTION 3 NFPA 285 Wall Assembly: Exterior Cladding Exterior Insulation Finishing Systems (EIFS) Metal Composite Materials (MCMs) Fiber Reinforced Plastics (FRPs) High Pressure Laminates (HPLs) - 1409.10 Available in Open and Closed Joint Systems Approximate 4mm-12mm panel thickness Different core materials have different fire performance characteristics Installations less than 40 above grade Limited to 10% area when separation < 5 http://www.trespa.com

SECTION 3 NFPA 285 Wall Assembly: Air & Water Barrier Air & Water Barriers 1403.5 Combustible Claddings EIFS - 1408.2 MCM - 1407.10 FRP - 2612.5 HPL - 1409.10 Foam Plastic Insulation 2603.5.5

SECTION 3 NFPA 285 Wall Assembly: Air & Water Barrier COMBUSTIBLE Water Resistive Barriers (WRBs) Building Wraps Self Adhered Building Wraps Self Adhered Membranes Fluid Applied Membranes 2012 IBC: Installations over 40 above grade must meet the requirements of NFPA 285 (Type I, II, III, or IV) 2015 IBC has approved WRB exceptions based on material properties and fuel load potential

SECTION 3 NFPA 285 Wall Assembly: Air & Water Barrier IBC NFPA 285 Test Requirements for WRBs NFPA 285 Test Req s Pre-2012 2012 2015 None Installations over 40 above grade must meet the requirements of NFPA 285 (Type I, II, III, or IV) Exceptions N/A None 1. WRB is the only combustible wall component and the wall has a non-combustible covering (Table 1405.2) 2. WRB is the only combustible wall component and: - ASTM E84 Product Test: Type A -flame spread index of 25 or less -smoke-developed index of 450 Class A - ASTM E1354 (Cone Calorimeter)Product Test: - Incident radiant heat flux of 50 kw/m 2. - Effective Heat of Combustion of less than 18 MJ/kg - Peak Heat Release Rate less than 150 kw/m 2 - Total Heat Release of less than 20 MJ/m 2 3. Windows and doors, and window/door flashings

Section 3: Combustible Components in a Noncombustible Wall Assembly WRBs Cladding Foam Insulation

Section 4: NFPA 285 Compliant Assemblies

SECTION 4 NFPA 285 Test Logistics Limited Testing Laboratory Availability Intertek (San Antonio, TX) Southwest Research (San Antonio, TX) Architectural Testing (York, PA) Potentially High Project Costs High Testing Cost Long Lead Time Product Selection Planning in Design Results are owned by the company paying for the test No directory of listed assemblies No direct method for substituting assembly components

SECTION 4 Wall Designs with Combustible Components 1. Use existing NFPA 285 tested compliant system OR 2. Test new assembly per NFPA 285 OR 3. Modify an existing NFPA 285 compliant system with local Authority Having Jurisdiction (AHJ) approval, such as building officials

SECTION 4 NFPA 285 Compliant Assemblies are Specific Required for various components in all configurations For example, there is no one test or test assembly to qualify a WRB for use in all assemblies Changes in configurations (air gaps, attachment systems, etc.) can cause different results If a New combustible component is added in the wall assembly, then new testing required for all of the various configurations.

SECTION 4 Variations in Wall Assemblies = Many Tests WRB / Polyiso WRB / Polyiso / WRB / Polyiso / Over / Polyiso Over / Polyiso / Over / Polyiso / / Fiber Cement WRB / XPS WRB / XPS WRB / XPS XPS / Over / Over / XPS / XPS Over / / Stucco WRB / Mineral Fiber / WRB/ Mineral Fiber WRB/ Mineral Fiber Over / Mineral Fiber Over / Mineral Fiber / Over / Mineral Fiber / EIFS

SECTION 4 NFPA 285 Assembly Compliance Considerations Substitutions of one material for another can cause different test results Addition of combustibles (insulation, WRBs, etc.) can cause different test results Wall systems made of a number of previously NFPA 285 tested materials does not ensure a successful NFPA 285 test Tests are required for many various claddings and other combustible wall components insulation, WRBs

SECTION 4 Engineering Judgment Letter Written by a independent source, approved by the building official competent and experienced in engineering principles of materials, methods or system analysis References Specific NFPA 285 PASS test results (owned by manufacturer) Specifies all corresponding wall components evaluated (structure, insulations, WRB, Claddings etc.) Outlines opening details and flashing conditions evaluated

SECTION 4 Engineering Judgment Letter: WRB Example http://www.exponent.com Letter Expands Assembly Test Results by 4 Products

AIA/CES LU Learning Objectives Understand fire performance requirements in International Building Code (IBC) Learn about fire related tests referenced by IBC Understand NFPA 285 wall assembly testing Understand which assembly components trigger NFPA 285 testing Understand how to determine if your assembly requires NFPA 285 testing Learn about potential alternative options to address compliance with NFPA 285

AIA/CES LU This concludes the American Institute of Architects Continuing Education Systems Program DuPont Building Innovations DuPont Tyvek Weatherization Systems Maria.spinu@dupont.com