PSR-PS20. SIL coupling relay. Data sheet. 1 Description

Similar documents
Redundancy Module QUINT-DIODE/40

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

PHOENIX CONTACT Features

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Safety technique. Emergency stop module BO 5988 safemaster

MINI MCR-SL-R-UI(-SP)

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PFE

CompactLogix Power Supplies Specifications

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

SAFETY MANUAL SIL RELAY MODULE

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

E-STOP relays, safety gate monitors

Power Supplies 3. SDN-P DIN Rail Series

Digital input modules

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

38 Series - Relay interface modules A

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

SAFETY MANUAL SIL Switch Amplifier

RM4TG20 three-phase network control relay RM4-T - range V

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Contact expander modules

38 Series - Relay interface modules A

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

48 SERIES Relay interface modules 10 A

Contact expansion modules

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet _en_02. 1 Description

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

PNOZsigma - Base units

Safety Manual BT50(T) Safety relay / Expansion relay

Inductive sensor NI10-M18-Y1X-H1141

49 Series - Relay interface modules A. Features

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

PHOENIX CONTACT - 01/2007

Pluggable interface relays CR-P Pcb relays

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

MCR1900 Media Converter 19-Slot Chassis

CONFIGURABLE SAFETY RELAYS

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

MasterINTERFACE 39 Series - Relay interface modules

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

E-STOP relays, safety gate monitors

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Telephone- and leased line modem for industrial applications TD-36

DLP-PU/E Instruction Manual

Inductive slot sensor

E-STOP relays, safety gate monitors

Cross-beam scanning system to detect slim objects. 100 mm in

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Technical Data. Dimensions

Modular I/O System Analog and Digital Interface Modules

Product and functional description

Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.

Relés e Contatores de Estado Sólido SIRIUS

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

E-STOP relays, safety gate monitors

80 Series - Modular timers 16 A. Features

E-STOP relays, safety gate monitors

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

MasterINTERFACE 39 Series - Relay interface modules

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Adjustment functions for both span and shift have been incorporated

Analog signal converters CC-E I/I Current / current isolators

mecotron Safety relay ESTOP-2 For emergency stop monitoring

SYSTEM DESCRIPTION Termination Boards

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

Emergency lighting units EM powerled

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

ADM1TE 5/30A DIN rail single phase two wire energy meter

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

TX OPEN RS232/485 module

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Electronic overload relay EF19 and EF45

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Bimetallic Overload Relay Specifications

Transcription:

SIL coupling relay Data sheet 106252_en_00 PHOENIX CONTACT 2015-03-13 1 Description Intended Use The PSR-PS20 SIL coupling relay can be used for power adaptation and electrical isolation in high and low-demand applications up to SIL 3 according to IEC 61508 as well as EN 61511. Using this module, circuits are interrupted in a safety-oriented manner. The category 3 device is designed for installation in zone 2 potentially explosive areas. The safety relay is equipped with an enabling current path and a confirmation current path that drop out without delay according to stop category 0 in accordance with EN 60204-1. By filtering the controller test pulses, premature failure of the safety relays is prevented. If an error occurs inside the module, the internal device input impedance is affected. As such with compatible, safe systems, the test pulses sent from the controller may be disrupted and the error can be reported back to the corresponding digital output without any additional wiring effort. Features SIL 3 coupling relay for safety-related switching off Can be used in high and low-demand applications Approved for Class I, Zone 2 applications Easy proof test: - Active error acknowledgment via A1 - Visually on the device - Evaluation of the force-guided N/C contact Integrated DCS test pulse filter Low inrush current 1 undelayed enabling current path 1 undelayed confirmation current path 1 digital signal output Fixed screw connection 6.8 mm housing width Controller-specific Termination Carrier available on request WARNING: Risk of electric shock Observe the safety instructions in the corresponding section! Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. This data sheet is valid for all products listed on the following pages.

2 Table of contents 1 Description... 1 2 Table of contents... 2 3 Ordering data... 3 4 Technical data... 3 5 Safety notes... 6 5.1 Installation in the Ex area (zone 2)... 7 5.2 Installation in areas with a danger of dust explosions... 7 6 Basic circuit diagram... 8 7 Derating... 8 7.1 Vertical mounting position... 8 7.2 Horizontal mounting position... 8 7.3 Mounting position with module front at the top... 9 8 Load curve... 9 8.1 Ohmic load... 9 9 Operating and indication elements... 10 9.1 Connection versions... 10 9.2 Connection assignment... 10 10 Mounting and connection... 11 11 Startup... 11 12 Proof test... 11 13 Calculating the power dissipation... 12 14 Application examples... 13 14.1 Application example 1 - SIL 3... 13 15 Revision history... 14 106252_en_00 PHOENIX CONTACT 2

3 Ordering data Description Type Order No. Pcs. / Pkt. Coupling relay for SIL 3 high and low-demand applications, couples digital output signals to the I/O, 1 enabling current path, 1 confirmation current path, 1 digital signal output, safe state off applications, test pulse filter, fixed screw terminal block PSR-PS20-1NO-1NC-24DC-SC 2700356 1 4 Technical data Hardware/firmware version HW/FW 00/-- (The technical data and safety characteristics are valid as of the specified HW/FW version.) Input data Rated control supply voltage U S 24 V DC -15 % / +10 % Rated control supply current I S typ. 45 ma Supply voltage 24 V DC -15 % / +10 % (Diagnostic supply voltage U D ) Input current 6 ma (at 21-A2 for U D ; depending on load + 100 ma at M1 and 22) Typical inrush current 400 ma ( t < 10 s at U s ) 2.5 A ( t < 20 s at U D ) Power consumption at U S Filter time typ. 1.08 W max. 2 ms (at A1-A2; test pulse width) 100 ms (at A1-A2; test pulse rate) Typical starting time with U s < 100 ms (when controlled via A1) Typical release time with U s < 35 ms (when controlled via A1) Recovery time 500 ms Maximum switching frequency 1 Hz Operating voltage display 1 x yellow LED Status display 2 x green LEDs Indication 1 x red LED Protective circuit Surge protection Suppressor diode Polarity reversal protection for rated control supply voltage and diagnostic supply voltage Output data Contact type Contact material Minimum switching voltage Maximum switching voltage Nominal current Limiting continuous current Maximum inrush current Inrush current, minimum Sq. Total current 1 enabling current path 1 confirmation current path AgSnO 2 (enabling current path) AgCuNi, + Au (confirmation current path) 20 V AC/DC (N/O contact) 20.4 V DC (N/C contact) 250 V AC/DC (N/O contact) 26.4 V DC (N/C contact) 6 A (N/O contact) 6 A (N/O contact) 100 ma (N/C contact) 6 A (N/O contact) 100 ma (N/C contact) 3 ma (N/O contact) 1 ma (N/C contact) 36 A 2 (see to derating) 106252_en_00 PHOENIX CONTACT 3

Output data Switching capacity min. Mechanical service life Output fuse 60 mw 10 x 10 6 cycles 6 A gl/gg (N/O contact) 4 A gl/gg (for low-demand applications) 150 ma fast blow (Confirmation current path) Alarm outputs Number of outputs 1 (digital, PNP) Voltage 22 V DC (U D - 2 V) Current max. 100 ma Maximum inrush current 500 ma ( t = 1 ms at U s ) Short-circuit protection no General data Relay type Electromechanically forcibly guided, dust-proof relay. Nominal operating mode 100% operating factor Degree of protection IP20 Min. degree of protection of inst. location IP54 Mounting type DIN rail mounting Mounting position vertical, horizontal, with front of module upward Assembly instructions See derating curve Dimensions (W/H/D) 6.8 x 93.1 x 102.5 mm Type of housing PBT yellow Clearances and creepage distances between the power circuits DIN EN 50178, EN 60079-15 Rated insulation voltage 250 V AC Rated surge voltage/insulation Safe isolation, 6 kv reinforced insulation from control circuit, start circuit, confirmation current path, signal output to the enabling current path; 4 kv/basic insulation between all current paths and housing Pollution degree 2 Surge voltage category III Connection data Connection method Screw connection Conductor cross section, solid 0.2 mm²... 2.5 mm² Conductor cross section, stranded 0.2 mm²... 2.5 mm² Conductor cross section AWG/kcmil 26... 12 Stripping length 12 mm Screw thread M3 Ambient conditions Ambient temperature (operation) -40 C... 70 C (observe derating) Ambient temperature (storage/transport) -40 C... 85 C Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing) Max. permissible humidity (storage/transport) Maximum altitude Shock Vibration (operation) 75 % (on average, 85% infrequently, non-condensing) max. 2000 m (Above sea level) 15g 2g Conformance / approvals Conformance Approvals UL, USA / Canada ( E140324 ) CE-compliant culus 106252_en_00 PHOENIX CONTACT 4

Conformance / approvals UL, USA / Canada ( E360692 ) Class I, Zone 2, AEx na nc IIC T4 / Ex na nc IIC Gc T4 X Shipbuilding GL applied for Functional Safety in accordance with IEC 61508 to SIL 3 Safety data Stop category according to IEC 60204 0 Safety parameters for IEC 61508 - High demand Equipment type Type A HFT 1 SIL 3 (< 15% of the overall SIL) PFH d 1.95 x 10-10 (4 A DC13; 5 A AC15; 8760 switching cycles/year) Demand rate < 12 Months Proof test interval 240 Months Duration of use 240 Months For use in high-demand applications, the diagnostics function must be implemented via the confirmation current path. Alternative illustration of the device as 1001 structure for process customers Equipment type Type A HFT 0 SIL 3 (< 15% of the overall SIL) Safe Failure Fraction (SFF) 99.98 % SD 989.32 FIT SU 148.96 FIT DD 52.58 FIT DU 0.20 FIT Total 1191.06 FIT MTBF 80.63 Years PFH 1.95 x 10-10 (4 A DC13; 5 A AC15; 8760 switching cycles/year) Safety parameters for IEC 61508 - Low demand Equipment type Type A HFT 1 SIL 3 (< 15% of the overall SIL) PFD avg 1.27 x 10-4 Proof test interval 72 Months Duration of use 240 Months Alternative illustration of the device as 1001 structure for process customers Equipment type Type A HFT 0 SIL 3 (< 15% of the overall SIL) Safe Failure Fraction (SFF) 99.66 % SD 0 FIT SU 1579 FIT DD 0 FIT DU 5.392 FIT Total 1584 FIT MTBF 63 Years PFD avg 2.36 x 10-5 (For T1 = 1 year) 106252_en_00 PHOENIX CONTACT 5

5 Safety notes WARNING: Risk of electric shock During operation, parts of electrical switching devices carry hazardous voltages. Before working on the switching device, disconnect the power. Please observe the safety regulations of electrical engineering and industrial safety and liability associations! Disregarding these safety regulations may result in death, serious personal injury or damage to equipment. Startup, mounting, modifications, and upgrades should only be carried out by a skilled electrical engineer! WARNING: Risk of automatic machine restart! For emergency stop applications, the machine must be prevented from restarting automatically by a higher-level control system. Protective covers must not be removed when operating electrical switching devices. WARNING: Danger due to faulty devices! The devices may be damaged following an error and correct operation can no longer be ensured. In the event of an error, replace the device immediately. Repairs to the device, especially if the housing must be opened, may only be carried out by the manufacturer or authorized persons. Otherwise the warranty is invalidated. WARNING: danger due to magnetic interference! Do not use the device in the vicinity of strong magnetic fields (e.g., caused by transformers or magnetic iron). The magnetic field strength of the environment must not exceed 30 A/m. NOTE: Risk of damage to equipment due to noise emissions When operating relay modules the operator must meet the requirements for noise emission for electrical and electronic equipment (EN 61000-6-4) on the contact side and, if required, take appropriate measures. NOTE: Risk of damage to equipment due to noise emissions This is a Class A product. In a domestic environment it may cause radion inteference, in which case the user may be required to take adequate measures. Only use power supply units with safe isolation and SELV / PELV in accordance with EN 50178/VDE 0160 (SELV / PELV). NOTE: Electrostatic discharge! The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and EN 61340-5-2. WARNING: Risk due to incorrect installation For reliable operation, the safety relay must be installed in housing protected from dust and humidity (IP54). Carry out wiring according to the application. Refer to the Application examples section for this. WARNING: Risk due to welded relay contacts A suitable and effective protective circuit is to be provided for inductive loads. This is to be implemented parallel to the load and not parallel to the switch contact. 106252_en_00 PHOENIX CONTACT 6

5.1 Installation in the Ex area (zone 2) Ambient temperature in hazardous areas (zone 2) WARNING: Explosion hazard The category 3 device is suitable for installation in the zone 2 potentially explosive area. It fulfills the requirements of EN 60079-0:2012+A11:2013 (IEC 60079-0:2011 6th ED.) and EN 60079-15:2010 (IEC 60079-15:2010 4th ED.). WARNING: Explosion hazard The device should be installed in a housing (control or distributor box) that fulfills the requirements of EN 60079-15:2010 (IEC 60079-15:2010 4th ED.) and at least IP54 (EN/ IEC 60529) degree of protection. WARNING: Explosion hazard The device must be used in no more than a pollution degree 2 environment as defined by EN/ IEC 60664-1. Observe the derating curves. Observe the special temperature conditions according to the rating plate. Output Ambient Temperature NO-contact 250 V AC / 24 V DC 6 A, Resistive B300, R300-20 C to 65 C DO-contact 24 V DC 100 ma Resistive 5.2 Installation in areas with a danger of dust explosions WARNING: Explosion hazard The device is not designed for use in atmospheres with a danger of dust explosions. WARNING: Explosion hazard When installing and connecting the supply and signal circuits observe the requirements of EN/ IEC 60079-14. Only devices suitable for operation in Ex zone 2 and the conditions at the application site may be connected to the circuits in zone 2. In potentially explosive areas, only connect and disconnect cables when the power is disconnected. WARNING: Explosion hazard The device must be stopped and immediately removed from the Ex area if it is damaged or was subject to an impermissible load or stored incorrectly or if it malfunctions. Only use category 3G devices (ATEX 94/9/ EC). 106252_en_00 PHOENIX CONTACT 7

6 Basic circuit diagram 7 Derating A1 21 13 7.1 Vertical mounting position PWR PSR-PS20 ERR DGN K1/2 K1 K2 I TH² [A ] 2 40 36 30 25 24V DC 20 A2 Figure 1 M1 Block diagram 22 14 10 0 12 4 10 20 30 40 50 55 60 65 70 Key: Designation A1 A2 M1 Explanation +24 V control input with active error acknowledgment 0 V (GND) Signal output (PNP) 21 +24 V diagnostics input 22 Diagnostic output +24 V 13/14 Enabling current path, undelayed Confirmation current path 21/22 (N/C contact) is not an electrically isolated current path and may only be connected to a maximum voltage of 26.4 V in relation to A2. Figure 2 Derating curve - vertical mounting position with connected modules Expanded ambient temperature range (with no distance): up to +70 C Conditions: Max. rated control supply voltage 24 V DC Max. total current of the enabling current path 1 A 2 7.2 Horizontal mounting position I TH² [A ² ] 40 36 30 T A [ C] 20 16 10 0 Figure 3 6 1 10 20 30 40 50 55 60 65 70 T A [ C] Derating curve - horizontal mounting position with connected modules Expanded ambient temperature range (with no distance): up to +70 C Conditions: Max. rated control supply voltage 24 V DC Max. total current of the enabling current path 250 ma 2 106252_en_00 PHOENIX CONTACT 8

7.3 Mounting position with module front at the top 8 Load curve I [A ] 2 2 TH² 40 36 30 20 10 25 12 8.1 Ohmic load 0 Figure 4 2 10 20 30 40 50 55 60 65 70 T A [ C] Derating curve - mounting position with module front at the top and aligned modules Expanded ambient temperature range (with no distance): up to +70 C Conditions: Max. rated control supply voltage 24 V DC Max. total current of the enabling current path 250 ma 2 Figure 5 Relay load curve - ohmic load 106252_en_00 PHOENIX CONTACT 9

9 Operating and indication elements 9.1 Connection versions 1 Fixed screw connection 2 Snap-on foot for DIN rail mounting 1 The year the device was constructed can be found underneath the CE designation on the housing. APPROVALS APPROVALS HW/FW: 00/-- HW/FW: 00/-- Serial Serial No. No. xxxxxxxxxx xxxxxxxxxx 2 Warning Warning -- Do Do not not seperate seperate when when energized! energized! PWR AWG 26-12 0,2-2,5 mm 2 PHOENIX CONTACT GmbH & CO.KG Flachsmarktstrasse 8 32825 Blomberg, Germany 14 12 mm 0,5-0,6 Nm 5-7 lb In PWR Figure 6 Connection versions Figure 7 Year of manufacture of the device 9.2 Connection assignment Figure Designation Explanation 22 Diagnostic output +24 V 2 2 2 1 21 +24 V diagnostics input A 2 A2 0 V (GND) A 1 A1 +24 V control input with active error acknowledgment PWR PWR Power LED (yellow) K1/ 2 ERR DGN K1/2 Status indicator safety circuit; LED (green) ERR Error LED (red) DGN Diagnostics LED (green) PS 20 1 3 1 4 M 1 13/14 Enabling current path, undelayed M1 Signal output (PNP) 106252_en_00 PHOENIX CONTACT 10

10 Mounting and connection Mount the module on a 35 mm DIN rail according to EN 60715. 12 Proof test In the proof test, you check the individual relay channels. 1. Activate A1/A2. 2. Apply the 24 V DC diagnosis power supply to contact 21. If the green DGN-LED lights up, the module is functional. (Apply 24 V DC to signal output M1.) Figure 8 Mounting and removing Connect the cables to the connection terminal blocks using a screwdriver. B If the red ERR LED lights up, replace the module. (Apply 0 V DC to signal output M1. Error acknowledgment via A1 is inactive.) If the diagnostic voltage supply is present and the green DGN LED and the red ERR LED are on, replace the module. If the diagnostic voltage supply is present but neither of the LEDs specified is on, replace the module. AWG 26-12 0,2-2,5 mm 2 Replace the device in the event of an error. A 12 mm 0,5-0,6 Nm 5-7 lb In Figure 9 Connection of the cables For compliance with UL approval, use copper wire that is approved up to 60 C/75 C. 11 Startup Apply the rated control supply voltage to terminals A1/A2. The PWR LED and K1/2 LED light up. Enabling current path 13/14 closes, and confirmation current path 21/22 opens. 106252_en_00 PHOENIX CONTACT 11

13 Calculating the power dissipation The total power dissipation of the safety relay is based on the input power dissipation and the contact power dissipation for the same and for different load currents. Input power dissipation P Input = U ² B / (U S /I S ) Contact power dissipation With the same load currents: P Contact = n I ² L 50 mω With different load currents: P Contact = (I ² L1 + I ² L2 +... + I ² Ln ) 50 mω Total power dissipation P Total =P Input + P Contact therefore P Total = U ² B / (U S /I S ) + n I ² L 50 mω or P Total = U ² B / (U S /I S ) + (I ² L1 + I ² L2 +... + I ² Ln ) 50 mω Key: Designation P U B U S I S n I L Explanation Power dissipation in mw Applied operating voltage Rated control supply voltage Rated control supply current Number of enabling current paths used Contact load current 106252_en_00 PHOENIX CONTACT 12

14 Application examples Key: SIS = Safety Instrumented System (safe control) DC = Diagnostic Coverage according to IEC 61508 (line/load diagnostics at DO) DI = Digital input DO = Digital output Applications with the PSR-PS20 14.1 Application example 1 - SIL 3 Low-demand application Single-channel control Diagnostic supply voltage is present Data for the application example as 1001 structure Equipment type A HFT 0 SIL 3 SFF 99.66 % SD 0 FIT SU 1579 FIT DD 0 FIT DU 5.392 FIT Total 1584 FIT MTBF 63 years PFD avg 2.36 x 10-05 (for T1 = 1 year) A fault e.g., open circuit or short circuit of the load is reported by detuning the test pulse of the safe controller. SIS DC 90% DO DO DI L 24V A1 13 ( ) 21 K1 PSR-PS20 A2 14 ( )22 ( ) M1 K2 K1 M K2 M (N) Figure 10 Application example 1 - SIL 3 106252_en_00 PHOENIX CONTACT 13

15 Revision history Version Date Contents 00 2015-03-10 First publication 106252_en_00 PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg Germany 14 phoenixcontact.com