Solbrake Electronic Motor Brake (DC Injection) A, V

Similar documents
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

RVS-DX Instruction Manual

Single Phase Soft Starter

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

MOTOR CONTROL IS OUR NATURE

DLP-PU/E Instruction Manual

RVS-DX Instruction Manual

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Digi-Motor Installation Guide

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

TIG INVERTER INSTRUCTION MANUAL

Thyristor-controlled power supplies and battery chargers

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

WE-350 Series ¼ Turn Electric Actuator

Cross-beam scanning system to detect slim objects. 100 mm in

INSTALLATION & SERVICE MANUAL. Display Panel

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

CQM1-SF200/CS1W-SF200

PSR The compact range Description

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

DC Motor control Reversing

MCR1900 Media Converter 19-Slot Chassis

Power Supplies 3. SDN-P DIN Rail Series

Antec TruePower User's Manual

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Electronic overload relay EF19 and EF45

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

12. Inspection and Maintenance

Phone: Fax: Web: info@clrwtr.com

Data Sheet. Electro-mechanical counters Hengstler 800 series

Three-phase monitoring relay CM-PFE

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

SPEED CONTROL SYSTEM

RVS-DXM Instruction Manual

Contents. Document information

WD-AMX Water Detection Controllers

Principles of Adjustable Frequency Drives

, User s Manual

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

CAT AVR V2.3. Instruction Manual. Voltage regulator for generators. March 2008

Section 10. Application Manual for NEMA Motors. Special Applications

Operating Instructions

Drayton Digistat +2RF/+3RF

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

INSTALLER S & OWNER S MANUAL

Portable Air Conditioner

Thyristor power units and Solid state contactors. TC2000 series. Two-phase control of a three-phase load or control of two single-phase loads

Problem / Solution. The problem:

Installation and Operating Manual

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Circuit Breakers. NRC Series. NRC Series

Softstarters Type PSR

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electronic overload relay EF65, EF96 and EF146

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

HERZ-Thermal Actuators

Bulletin 150 SMC Flex Smart Motor Controller Specifications

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Power Thyristor TS3 (SP) 3ph. Installation Guide

Mounting Instructions. Torque Transducer. A en

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Manual for Fire Suppression & Methane Detection System

ABB i-bus KNX SA/S Switch Actuators Product Manual

Rotary Phase Converters

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

User s Manual Before using the inverter, you need to read and save the safety instructions.

C Standard AC Motors

GPD 506/P5 Start-up Procedure and Checklist

32VFD Variable Frequency Drives for Centrifugal Chillers

BG or BGE Brake Rectifier

User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331)

*.ppt 11/2/ :48 PM 1

Thermistor motor protection

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

Specifying a Variable Frequency Drive s

Diesel Engine Driven Generators Page 1 of 6

Transcription:

Solbrake Electronic Motor Brake (DC Injection) 10-460A, 220-690V Instruction Manual Ver.200605 1

Table of Contents Page Subject 3 Brake selection 4 Installation Notes 5 Mode of operation 6-8 Wiring and operation 9 Potentiometer settings and Start up procedure 10 Fuse Selection Table 11-12 Dimensions 13 Technical Specification 14 Ordering Information * Read this manual carefully before operating the equipment and follow its instructions * Installation, operation and maintenance should be in strict accordance with this manual, national codes and good practice. Installation or operation not performed in strict accordance with these instructions will void manufacturer's warranty. * Disconnect all power inputs before servicing the Solbrake and/or the motor. * After installation, check and verify that no parts (bolts, washers, etc) have fallen into the power Section (IP00). ATTENTION 1. This product was designed and tested for compliance with IEC947-4-2 for class A equipment. 2. The Solbrake brakes are designed to meet UL requirements 3. Use of the product in domestic environments may cause radio interference, in which case the user may be required to employ additional mitigation methods. 4. Utilization category is AC-53a or AC53b. Form1. 5. For further information see Technical Specification WARNING * Internal components and P.C.B's are at mains potential when the Solbrake is connected to mains. This voltage is extremely dangerous and may cause death or severe injury if contacted. * When the Solbrake is connected to mains, even if operation signal is disconnected full voltage may appear on Solbrake output. * Unit must be grounded to ensure correct operation, safety and to prevent damage. * Check that Power Factor capacitors are not connected to the output side of the Solbrake. 2

Brake Selection General The Solbrake - Solid State Motor Brake provides fast, smooth, frictionless braking of three-phase squirrel-cage motors by injecting controlled DC current to the motor windings, after Mains contactor opened. This induces a stationary magnetic field, which exerts a braking torque on the rotor. Stopping time can be similar to the time it takes to reach full speed on a Direct-On-Line starting. Adjustable Braking Torque and Braking Time enable perfect matching of the brake to the driven load. Automatic sensing System turns the brake off automatically when the motor comes to a full stop. This minimizes the motor heating. RPM Brakes ratings and Frame sizes Max Motor FLA (Amp) Brake Type FLC Frame Size Case material 10 Solbrake 10 SB0 PC/ABS 17 Solbrake 17 31 Solbrake 31 SB1 58 Solbrake 58 Aluminum 105 Solbrake 105 SB2 210 Solbrake 210 Metal 310 Solbrake 310 390 Solbrake 390 SB3 460 Solbrake 460 Dimensions (mm) Solbrake Wood Saw Stopping Time Centrifuge Size Width Height Depth SB0 45 75 105 SB1 65 190 114 SB2 154 280 160 SB3 224 384 222 t Select the brake according to the following criteria: Motor Current & starting conditions Motor's Full Load Ampere (FLA) - as indicated on its nameplate (even if the motor is not fully loaded). The Solbrake is designed for a duty cycle of 10% or less; e.g. 10 sec. operation, 90 sec. rest. Duty Cycle - the ratio between operating time and total cycle time (rest time + Braking time). Braking time Duty Cycle = ------------------------------- x 100 (%) Rest time + Braking time Note: If a higher duty cycle is required select a higher Solbrake type to allow enough brake time current. Mains Voltage (line to line) Thyristor's PIV rating, internal circuitry and insulation determines six voltage levels: Each brake is factory set for one of the following levels according to the Ordering Information. Voltage Tolerance 230 V +10-15 % 400 V +10-15 % 440 V +10-15 % 480 V +10-15 % 600 V +10-15 % 690 V (210A-460A) +10-15 % Each brake is factory set for one of the above levels and suitable for 50 or for 60 Hz (± 5%). Options (see Ordering Information) For extended braking time - consult factory and provide the following information: Ambient temperature. Actual stopping current. Actual stopping time. Time interval between starts Load characteristics 3

Installation Notes Prior to Installation Check that Motor's Full Load Ampere (FLA) is lower than or equal to Solbrake Full Load Current (FLC) and verify that Mains voltage and frequency are as indicated on the Solbrake label. Mounting * The Solbrake must be mounted vertically, allow space above and below the unit for sufficient airflow. * It is recommended to mount the Solbrake directly on the rear metal plate for better heat dissipation. * Do not mount the Solbrake near heat sources. * Protect the Solbrake from dust and corrosive atmosphere. Temp. Range and Heat Dissipation The Solbrake is rated to operate over a temperature range of -10 C (14 F) to +50 C (122 F). Relative non-condensed humidity inside the enclosure should not exceed 93%. The average heat dissipation of the Solbrake depends on the Braking Torque setting and on the duty cycle. Heating inside the enclosure can be reduced through the use of additional ventilation. Note: The heat generated in the motor during braking is similar to the heat generated during starting. Therefore, high setting of the Braking Torque and/or a high duty cycle may require an external cooling fan for the motor. It is recommended to use temperature sensor in the motor which will allow restarting only after the motor temperature has reduced to an allowed level. Short Circuit Protection The Solbrake must be protected against short circuit by fast-acting fuses. Recommended I 2 t values in page 9. Transient Protection Line transient voltages can cause malfunctioning of the brake and damage to the SCRs. When high transients are expected, an external protection should be used, (consult factory). Wiring Connections to L 1, L 2, U, V should be done with full size power cables. Connections to terminals 1-6 and W are control wires size. Do not connect two Solbrake brakes in parallel as they are not synchronized and will be damaged. Mechanical and electrical interlock between Mains contactor C 1 and braking contactor C br must be installed to prevent both contactors from being closed simultaneously. Solbrake Wiring The Solbrake (10-17) is meant for installation on a Din- Rail. See options list for other Din-Rail ratings. U V W L1 L2 1 2 3 4 5 6 Power Factor Capacitors Power factor correction capacitors must not be installed on the load side of the Solbrake. When required, capacitors should be installed on the Solbrake line side. Notes: 1. The Solbrake uses Mains power to produce the braking torque. Therefore, a power failure or disconnection will disable the DC braking and the motor will coast to a stop without braking. 2. When required to stop a motor during a power outage, an electro-mechanical brake must be used. 3. The Solbrake cannot be used for continuous holding of loads, after motor had stopped. An electromechanical brake should be used for holding at stop position. Warning Wrong connections of Solbrake line and load sides will cause damage to the brake and motor. 4

Mode of Operation Stop signal opens motor contactor C 1 that in turn initiates the closing of brake contacts C br. The Thyristor is switched on and fire (to inject DC current to the motor) after time delay, to induce the braking current. The torque, which is a function of the DC current, can be controlled by the firing angle of the Thyristor. Note: there is a time delay between opening of one contactor and closing the other one to reduce the EMF. The time delay correlate to the size of the motor. Braking Time Braking time depends on the inertia, friction of the load, speed, and braking current. The required braking time is best established by practical experience. The Solbrake offers two operating modes, Automatic and Manual. Selection between the modes is done by an internal dip switch. Dip sw. On Off Operation Mode Manual Automatic It is recommended to use the Automatic mode (factory default setting) to reduce the braking time and minimize motor heating. Automatic operation DC injection duration is automatically controlled by the Solbrake. Injection ceases when Motor has come to a complete stop. Manual operation DC injection duration is according to the Braking Time setting on the front panel. Braking contactor Closed Notes: 1. Motor heating during braking is similar to heating during Direct On Line starting. Therefore, always adjust for the shortest DC injection time duration. 1 DC Injection Motor Stopped Braking contactor 1 DC Injection Motor Stopped M 2. In general, for improved braking process to be in effect, it is recommended to apply some minimal inertia on the motor shaft. 10 10 Restart Enable Sec. Restart Enable Sec. The Solbrake incorporates the following built-in time delays: Power ON 1-2 Closed 1-2 Open Motor Contactor Brake Contactor DC Injection Start Stop Braking Process t1 t2 t3 t4 t5 Motor Running Where: t 1 - Time delay between opening of motor's contactor C 1 and closing of brake contactor C br, allowing motor's back EMF to diminish (see table below). t 2 - Time delay of 0.05 sec between closing of brake contactor C br and initiation of DC current, to ensure that brake contactor does not switch DC current, enabling the use of regular AC contactor. t 3 - In Auto Mode Enabling of DC current injection. In Manual Mode - time of DC current injection. Range: 1-10 sec. t 4 - Time delay between end of DC current injection and opening of brake contactor C br to ensure that the contactor does not switch DC current, enabling the use of regular AC contactor (see table below). t 5 - Time delay of 0.2 sec. between opening of brake contactor C br and enabling motor's restart. Approximate Time Delays (sec). Solbrake 10 17 58 105 210 390 t 1 0.2 0.3 0.6 1.1 1.7 2.5 t 4 0.2 0.2 0.3 0.8 1.2 1.9 Torque at standstill When required to maintain the DC braking current after the motor has come to a complete stop, set Auto/Man Dip Switch to On (Manual operation). Set Braking Time to a longer time than it takes the motor to come to a complete stop. Note - DC Injection after motor has come to a complete stop may cause excessive heating of both the motor and the brake. 5

Wiring & Operation Solbrake with Direct on Line Starter Motor contactor C 1 (with one N.O + two N.C contacts). * Contact C1 - Holding N.O contact of contactor C 1 * Contact C1 - auxiliary N.C contact of contactor C 1, initiates the braking process. * Contact C1 - auxiliary N.C contact of motor contactor acts as an interlock preventing operation of brake contactor as long as motor contactor is closed. Brake contactor C br (with one N.C contacts). * Contact C br - auxiliary N.C contact of contactor C br, acts as an interlock preventing operation of motor contactor as long as brake contactor is closed. Note: It is recommended to electro mechanically interlock contactors C 1 and C br. Solbrake contacts * Ca contact (Solbrake terminals 3-4), contact closes when Mains voltage is connected to Solbrake terminals and terminal 1-2 are open. * Cb contact (Solbrake terminals 5-6), closes upon stop signal and contact terminals 1-2 closes after time delay t 1. Notes * Motor contactor C 1 cannot be operated when Mains voltage is not connected to terminals L 1 and L 2 (internal contact Ca in Solbrake, controlling motor contactor, closes after Mains voltage is connected and terminal 1-2 are open. * When operating in Manual mode, DC injection will stop after time delay t 3 as set on the Braking Time potentiometer. Operation Upon start signal, as Ca is closed, motor contactor C 1 closes, motor will operate and contact C 1-1 opens. Upon stop signal, motor contactor C 1 opens, contact C 1-1 closes and initiates the braking process. Contact Ca opens, preventing motor contactor operation, and after time delay t1 contact C b closes, closing the brake contactor C br. The yellow LED on Solbrake front panel will light up indicating that brake contactor is closed. After time delay of approx. 0.05 sec. DC current will be injected to motors' winding. The yellow LED on Solbrake front panel will light up indicating that braking current is now injected to the motor. The DC injection will automatically cease when motor comes to a complete stop (when Automatic mode is selected) and the yellow LED turns off. Contact Ca closes after time delay t 5, permitting motor restarting. 6

Wiring & Operation Emergency Brake A dedicated Emergency Stop button, with two contacts initiates braking. When Stop contact is opened, contactor C 1 opens, the Solbrake is not initiated. When Emergency Button is pressed, the Emergency Contact is opened and the N.O. contact of the Emergency Stop closes and initiates the braking process. When Emergency Stop contact is opened, C1 contactor opens and the Solbrake is operated, initiating the braking process. Forward/Reverse C br - Solbrake Contactor. Cf - Forward Contactor Cr - Reversing Contactor Mechanically Interlocked Contactors. Braking process is initiated when Contactors Cf or Cr open. Star-Delta C br - Solbrake Contactor. Cs - Star Contactor Cd - Delta Contactor Cl - Line Contactor T1, T2 - Timer Relays Braking process is initiated when Contactors Cd,Cs & Cl will open. Hence, a mechanical interlock between Cbr and Cl is recommended. 7

Wiring & Operation Star-Delta Forward / Reverse Cf - Forward Contactor Cr - Reversing Contactor C br - Solbrake Contactor Cs - Star Contactor Cd - Delta Contactor Cl - Line Contactor T1, T2 - Timer Relays Braking process is initiated when Contactors Cd, Cs, Cf & Cr will be open. Hence, an electrical interlock between Cbr and Cf & Cr is recommended. 8

Potentiometer Setting Start-Up Procedure 1 10 2 10 Sec. Braking Torque Braking Time (Sec.) Braking torque Determines the value of DC current the Solbrake injects to the motor. The Solbrake can produce a braking current of up to four times motor's nominal current. A too high setting may cause a fast stop and high mechanical shock. A too low setting may result in prolonged time until motor stops. Braking Time * For Automatic Time-out - The setting on the front panel determines the period of time during which the braking contactor is closed. DC current ceases automatically when the motor stops (Factory default internal Dip Switch setting). * For Manual Time-out - The setting on the front panel determines the period of time during which DC current is injected to motor windings, regardless of when the motor stops (can be modified with the internal Dip Switch). Solbrake, Main PCB Dip Sw. S1.1=Auto/Man. Dip Sw. S1.2 = Not in use 1 2 On = Manual Off = Automatic LED Display The Green LED indicates that power supply is connected to the Solbrake (L 1, L 2 ). The Yellow LED indicates that contactor C br is closed. Motor restart is disabled when this LED is lit. The yellow LED indicates that DC current is being injected in the motor windings. On Braking DC Injection On During start-up the dip switch should be in the Off position for Automatic Time-Out. 1. Set Braking Torque to 5 2. Set Braking Time to 10 3. Start motor and wait until it reaches full speed. 4. Stop motor and check the braking procedure. a) If braking has ceased and motor is still turning, increase braking Torque setting and try again. b) If motor has stopped and the Yellow LED remains on, decrease Braking Time setting until the Yellow LED turns off shortly after the yellow LED has turned off. Note: Set Braking Time potentiometer t 3 to a slightly longer time than the time required for motor to come to a complete stop, even if the brake operates in an Automatic mode. This is required for two reasons: 1. Ensuring that even if the automatic time-out circuit did not sense that motor had stopped, the DC injection will cease shortly after motor stopped preventing excessive heating. 2. During time delay t 3, braking contactor remains closed even if the Automatic Time-Out circuit has stopped the DC current. Measuring the Braking Current Approximate measurement of the braking current can be made with a true RMS ammeter. Trouble Shooting 1. Disconnect Mains voltage and check that contacts 3-4 and 5-6 are open. 2. Connect power to L 1 and L 2. The green LED (On) should light up. 3. Check that contact between terminals 3-4 is closed. 4. Check that contact between terminals 5-6 is open. 5. Start the motor. Motor contactor should close. If it doesn't, check connection to contactor. 6. Press Stop button; motor contactor should open and brake contactor should close after a short time delay. Simultaneously the Braking Time and DC injection LEDs should be lit. If LEDs do not light up, check that auxiliary contact of Mains contactor connected between control terminals 1-2 is closed. 9

Fuse Selection Table (400V) FUSE SELECTION (recommended values for mains supply of 400V) RVS-DX Max. Thyristor I 2 t (A 2 Sec) Rated (A) BUSSMAN GEC ALSTOM SIBA P/N Rated (A) P/N Rated (A) P/N FERRAZ SHAWMUT (IEC Style 690/700V) Rated P/N (A) Solbrake 10 400 30 FWP 30B 32 B210612 32 URD 000-32 Solbrake 17 5,000 50 FWP 50B 63 B210615 63 6.6URD30D11A0063 Solbrake 31 12,000 125 FWP 125A 100 X320063 100 6.6URD30D11A0100 Solbrake 58 15,000 150 FWP 150A 125 X320065 125 6.6URD30D11A0125 Solbrake 105 60,000 250 FWP 250A 200 D320071 250 SQB1-250 250 6.6URD30D11A0250 Solbrake 210 200,000 500 FWP 500A 450 D320485 450 SQB1-450 450 6.6URD30D11A0450 Solbrake 310 600,000 700 FWP 700A 630 H320489 630 SQB1-630 630 6.6URD31D11A0630 Solbrake 390 700,000 700 FWP 700A 800 T320591 800 SQB1-800 800 6.6URD31D11A0800 Solbrake 460 1,200,000 1000 FWP 1000A 1000 W320593 900 SQB2-900 1000 6.6URD32D11A1000 Notes: 1. The above table is for maximum stop current of 400 % of FLC, maximum time of 30 sec and rated voltage of 400 V (see note 3 for exception). 2. Rating may change with different external conditions such as ambient temperature, forced cooling etc. Refer to fuse manufacturer catalogs to confirm correct values. 3. Ferraz ratings are simulated for 4xIn, 4 times per hour with a 10 sec. stop time for each stop. 10

Dimensions Solbrake 10A 90 105 U V W L 1 L 2 1 2 3 4 5 6 75 105 Solbrake 17-58A 11

Dimensions Solbrake 105-210A 77 160 280 263 L1 L2 U V W M6 12 17 12 20 12 Solbrake 310-460A 1 1 U L U L 384 63.4 W L V W V L 224 222 12

Technical Specification Environment Supply voltage Frequency Load Two phase, line to line. 220-600VAC (690VAC for 210A 460A) 50 / 60 Hz Three-Phase, Three-Wire, Squirrel Cage Induction Motor +10% -15% Duty cycle 10% max. 10 sec. operation, 90 sec. rest Degree of protection IP 20 up to 58A (IP00 up to 460A) Altitude Adjustments Braking current 1000 m above sea level 1-10 for 0-4 times FLC Braking time 2-10 sec. Optionally 1-30 sec. Protection Automatic stopped motor sensor Switches off the DC injection automatically when motor has come to a complete stop. Indications Indication lights (LEDs) ON - Green C br closed Yellow DC Injection ON - Yellow Illuminates when power is connected to Solbrake on L1 and L2. Illuminates when contactor C br is closed. Illuminates when DC current is being injected to the motor windings. Temperatures Operating -10 to 50 C Storage -20 to 70 C Relative humidity 93 % - non condensed 13

Ordering Information Brake FLC Mains voltage Options Front panel (1) (2) (3) (4) SOLBRAKE 31 400 0 S (1) SOLBRAKE FLC: 10, 17, 31, 58, 105, 210, 310, 390 Amp (2) Mains voltage Specify For 50/60Hz 230 230 Vac +10% -15% 400 400 Vac 440 440 Vac 480 480 Vac 600 600 Vac (3) Required options Specify For 0 No options. E Consult Factory 8 Harsh environment treatment (factory supplied) (4) Front panel Specify For S Standard 14