Elastic, liquid applied, 2 part polyurethane waterproofing membrane system

Similar documents
Elastic, 1-part-polyurethane, liquid waterproofing membrane

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

PRODUCT DATA SHEET Sika Cable System

Construction. Sikalastic -560 Economical and eco-friendly liquid applied roof waterproofing solution. Product Description.

Low viscosity, solvent free elastic adhesive for wood flooring

2-part Epoxy primer, levelling mortar and intermediate layer

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

2-part epoxy textured roller and seal coat

Sikagard -203 W (Steridex)

High-performance, 2-part epoxy anchoring adhesive

Wecryl Waterproofing System under surfacing supplied by others

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Division 9. SignaFlor Pad and Pour Flooring System

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm

BLACK JACK ALL WEATHER ROOF COATING

DENSO WATERPROOFING SYSTEMS

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

RECOATING AND RENEWING SPF ROOFING SYSTEMS

WATERPROOFING OF WET ROOMS

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

SC2000 CEMENT BONDING PROCEDURES

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

Polymeric membrane for roof waterproofing

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data January, 2010

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data March, 2002

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

WATERPROOFING FOR CONCRETE STRUCTURES

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

Technical Data Sheet February 2014

Solvent Cementing Instructions For Plastic Pipe & Fittings

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

Tecnoepo Flooring System 185

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Mineral waterproof coating PCI Dichtschlämme

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

3M Scotchkote Urethane Coating 165HB

BENTLEY ELEMENTS COLLECTION LVT

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

WOOD FLOORING ADHESIVES

Seamless Waterproofing. Systems

G4 is browny translucent in colour and is effected by UV light. Therefore it is for internal use unless top coated to protect it from UV light

Colorado State University. Durrell Center Roof Repair

SIKA BRIDGE DECK WATERPROOFING SYSTEM SIKALASTIC -851 BRIDGE DECK WATERPROOFING SYSTEM

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION

COATING & WRAPPING OF UNDERGROUND PIPING

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

3 Scotch-Weld TM. Structural Adhesive Films AF 6 AF 10 AF 13. Technical Data July, 2001

RESTORATION + DECORATION OF BALCONIES AND TERRACES. Decorative, Easy to Maintain and Slip-Resistant Surfaces

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

Concrete Waterproofing Systems. Integral Protection.

Mold Preventing I nterior System

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET

STERI-SOFT HIGH FOOT TRAFFIC, ULTRAVIOLET RESISTANT, URETHANE RESILIENT FLOORING SYSTEM, 1/8 GREEN BUILDING FEATURES TYPICAL APPLICATIONS

A. The CONTRACTOR shall provide pipe coating, complete and in place, in accordance with the Contract Documents.

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

Epoxy Floor Coating Problem Solving Guide

Note: Minor color change may occur in exposed service, but corrosion protection will not be compromised

TECHNICAL DATA SHEET HAMMERITE METAL PAINT. Smooth Hammered Satin Aerosol

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

12 POLYURETHANE ADHESIVE (PU 105)

WATERPROOFING BASEMENTS

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

PanelTack HM. for the bonding of SVK Ornimat SKG

Crystal Clear Sealant

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

GigaCrete Specification PlasterMax

POLYURETHANE LINING AND COATING ON PIPE RAW WATER

TECHNICAL PROPOSAL FOR WATERPROOFING TREATMENTS SYSTEM RECOMMENDATION

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

Temperature C Cure time to reach hours LSS > 1MPa minutes

Document Library TS Data Sheet M Windo-Weld Super Fast Urethane. Data Sheet. Public

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

The bonded waterproof membrane, which can be verified by non destructive means DENSARE /14 IHö/JP/KK

Transcription:

Product Data Sheet Edition 27/04/2012 Identification no: 02 09 15 20 500 0 000002 Sikalastic -450 h Elastic, liquid applied, 2 part polyurethane waterproofing membrane system Construction Product Description Sikalastic -450 h is an elastic, liquid applied, crack bridging, two part, polyurethane based membrane system. Its performance is maintained even at low temperatures. Uses Seamless coating on flat roofs and concrete structures (horizontal application). Can also be used as an exposed waterproofing membrane on non trafficked areas. Not suitable for permanent water immersion when used as exposed system (needs to be protected with mortar plaster). Characteristics / Advantages Tests Can be applied on concrete, brickwork, asbestos cement, roof tiles (Clay tile, mosaic tile, concrete tiles, etc, not suitable with Glazed/Ceramic/ China mosaic tiles), etc. Crack-bridging Highly elastic Excellent adhesion on multi substrate Easy application Root resistant Weather resistant Approvals / Standards Conforms to: IS 101, IS 2645, ASTM D 638, DIN 53504, DIN 53504. Product Data Form Appearance / Colour Packaging RAL 6005 (Moss green), 3011 (Brown red), RAL 7037 (Grey) liquid Part A: 12.0 kg container Part B: 0.48 kg container x 2 Part (A+B): 12.96 kg Part A: 1.00 kg container x 12 Part B: 0.08 kg container x 12 Part (A+B): 12.96 kg Storage Storage Conditions / Shelf Life 9 months from date of production if stored properly in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 C and +30 C. 1 1/5

Technical Data Chemical Base Density Polyurethane Part A 1.59 kg/l, Part B 1.21 kg/l All density values at +27 C Solid Content ~ 99% at 105 C System Layer Thickness ~ 1.5 mm Shore A hardness 20 ( after 14 days ) Accelerated weathering ( 500 hrs ) No cracking / blistering (According to IS 101) Water permeability Passes (According to IS 2645) Moisture permeability 5 mg/m 2 average (According to IS 101) Crack Bridging 2 mm at +27 C Crack resistance Passes 3 mm (According to IS 101) Tack Free Time Mechanical / Physical Properties 24 hours at +27 C Tensile Strength 1.3 N/mm 2 (28 days / +27 C) ( According to ASTM D 638) Elongation at Break Without Sika Fab-1 50%(28 days / +27 C) (According to DIN 53504) With Sika Fab-1 20% (28 days / +27 C) (According to DIN 53504) System Information System Structure Exposed Roofing-system Layer thickness: 1.5 mm Base Coating: Fabric reinforcement : 1 x Sika Fab 1 Top Coat : 1x Sikalastic -450 h Concealed Roofing-system Layer thickness: 1.5 mm primer Base Coating: Fabric reinforcement : 1 x Sika Fab 1 Top Coat : 1x Sikalastic -450 h + Sand sprinking UV-protection: Screed concrete with slope ( min avg. Thickness 50 mm ) admixed with Sika Fibre h-150 2 2/5

Application Details Consumption / Dosage Coating System Product Consumption Exposed Roofing-system, Concealed Roofing-system (according to ETAG 005) primer 1 x Sika Fab-1 primer 1 x Sika Fab-1 Sika Fibre h-150 0.200-0. 300 kg/m² 0.500 0.600 kg/m² 1 sq.mt / sq.mt 0.700 0.800 kg/m² 0.200-0. 300 kg/m² 0.500 kg/m² 1 sq.mt / sq.mt 0.700 kg/m² 0.900 kg/m3 by weight of cement These figures are theoretical and do not allow for any additional material due to surface porosity, surface profile, variations in level and wastage etc. Substrate Quality Substrate Preparation Priming The substrate must be clean, dry and free of all contamination such as dirt, oil, grease, coatings etc. which hinder an adhesion. The substrate must be sound and of sufficient strength. If in doubt, apply a test area first. Weak concrete must be removed and surface defects such as blowholes and voids must be fully exposed. All dust, loose and friable material must be completely removed from all surfaces before application of the product, preferably by brush and/or vacuum. Prime the prepared substrate with Sikalastic -450 h Primer after mixing two components of the primer. Mixing ratio of the primer Part A : Part B = 100 : 8 by weight. The material should be applied within 30 minutes after mixing. Application Conditions / Substrate Temperature Ambient Temperature Substrate Moisture Content < 4% moisture content. Test method: Sika -Tramex meter No rising moisture according to ASTM (Polyethylene-sheet). Application Conditions / Substrate Temperature Ambient Temperature Substrate Moisture Content Relative Air Humidity Dew Point < 4% moisture content. Test method: Sika -Tramex meter No rising moisture according to ASTM (Polyethylene-sheet). 80% r. h. max. Beware of condensation! The substrate and uncured membrane must be at least 3 C above the dew point to reduce the risk of condensation or blooming on the membrane finish. 3 3/5

Application Instructions Mixing Mixing Time Mixing Tools Application Method / Tools Part A : Part B =100 : 8 ( for both primer and coating ) by parts of weight Sikalastic -450 h is supplied in pre measured packs. Mix Component A mechanically for 2 minutes to break any settlement without introducing air in the material. To this add Component B completely and mix for 3 minutes. Again ensure that no air is introduced due to mixing. Sikalastic -450 h must be thoroughly mixed using a low speed electric stirrer (300-400 rpm) or other suitable equipment. By brush: With a thick haired brush. ( cut the brush hair to limit flapping ) By roller: With a solvent resistant, non-fuzzy roller. Cleaning of Tools Pot Life Waiting Time / Overcoating By spray: Airless spray equipment for 2 component spray application ( approved make Graco pumps ) Apply on vertical up to 300 mm / inclined areas with up to maximum of 3% slope Clean all tools and application equipment with Thinner C immediately after use. Hardened and/or cured material can only be removed mechanically. ~ 30 mins at +27 C Between consecutive coats of Sikalastic -450 h Substrate temperature Minimum Maximum +30 C 24 hour After thorough cleaning 1) 1) Assuming that all dirt has been removed and contamination is avoided Sikalastic -450 h can be overworked with another coat of Sikalastic -450 h at any time Notes on Application / For optimum application, do not allow liquid Sikalastic -450 h to be heated by direct sunlight or other heat sources. Not suitable for permanent water immersion when applied exposed without protection plaster / screed. During the curing process micro bubbles are formed. This is a product characteristic, which does not affect the protective properties. For this reason it should be ensured that the material is not applied at excessive film thicknesses in one layer. Excessive film thickness may create bubbles. The product can be applied by brush, roller or airless spray. Work well with a brush in difficult areas. Apply subsequent layers after the first layer has cured tack free. After Sikalastic -450 h has been exposed to UV light, it will start to yellow slightly without loosing its physical properties though. The product can be over coated with itself without further priming. Only mechanical abrasion over the cured layer and proper cleaning of dust / dirt before application of fresh layer shall be ensured. In order to cover joints, connections or overlaps of bituminous sheets, use strips of e.g. Sika Fab 1 to provide additional thickness. Please ask our technical service department for detailed recommendations depending on the actual site conditions. Curing Details Applied Product ready for use Temperature Rain resistant after Ready for foot traffic 1) (with care) Full cure +30 C ~ 24 hours ~ 3 days ~ 7 days 1) Only for inspection or for application of the next layer, not for permanent traffic. Note: Times are approximate and will be affected by changing ambient conditions. 4 4/5

Construction Value Base Health and Safety Information Legal Notes All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Material Safety Data Sheet containing physical, ecological, toxicological and other safety-related data. The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Sika India Pvt. Ltd. Commercial Complex II 620, Diamond Harbour Road Kolkata, 700 034, India Phone +91 33 2447 2448/2449 Telefax +91 33 2396 8688 ind.sika.com info.india@in.sika.com 5 5/5