Lecture VI Magnetic Design



Similar documents
Development of Radiation Resistant Quadrupoles Based on High Temperature Superconductors for the Fragment Separator

Introduction. Magnet Coordinate System

The half cell of the storage ring SESAME looks like: Magnetic length =

LHC MACHINE PROTECTION

Follow up and checkpoints of cable properties

Brookhaven Magnet Division - Nuclear Physics Program Support Activities

Mark Jaski. Multi-Bend-Achromat (MBA) Magnets

HIGH-ENERGY COLLIDER PARAMETERS: e + e Colliders (I)

physics 112N magnetic fields and forces

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Damping Wigglers in PETRA III

Zero Degree Extraction using an Electrostatic Separator

LHC optics measurement & correction procedures. M. Aiba, R. Calaga, A. Morita, R. Tomás & G. Vanbavinckhove

Manufacturing and Testing of Accelerator Superconducting Magnets

CABLE DESIGN AND RELATED ISSUES IN A FAST-CYCLING SUPERCONDUCTING MAGNETS

Industrial Involvement in the Construction of Synchrotron Light Sources

THE ALIGNMENT STRATEGY FOR THE SPIRAL2 SUPERCONDUCTING LINAC CRYOMODULES

Slice Emittance Measurements at the SLAC Gun Test Facility*

BEPC UPGRADES AND TAU-CHARM FACTORY DESIGN

B098N USERS: MACHINE MANUFACTURERS DRAUGHTSMEN OPERATORS MAINTENANCE WORKERS ANY OTHERS

Lab 4: Magnetic Force on Electrons

3D Printed Injection Molding Tool ("PIMT") Guide. Objet Ltd.

Cathode Ray Tube. Introduction. Functional principle

Insertion Devices Lecture 4 Permanent Magnet Undulators. Jim Clarke ASTeC Daresbury Laboratory

DOUBLE DRUM TRACTION WINCH SYSTEMS FOR OCEANOGRAPHIC RESEARCH 1.0 TRACTION WINCH SYSTEM ADVANTAGES 11-2

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

The performance improvement by ferrite loading means - increasing, - increasing of ratio, implicitly related to the input impedance.

x = u cos z =-u sin where d~ = - ~ B(s). ds 2p 1.2 Compensation by skew guadrupoles 2,3) - 8n~ E B(s) ds

Results: Low current ( ) Worst case: 800 MHz, GeV, 4 turns Energy oscillation amplitude 154 MeV, where

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

POWDER PROPERTIES LABORATORY

Hydraulics Laboratory Experiment Report

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999

Experiment 6: Magnetic Force on a Current Carrying Wire

The commissioning of the LHC: first the technical systems, then the commissioning with beam

DISCLAIMER. This document was prepared as an account of work sponsored by an agency of the United States

Trace Layer Import for Printed Circuit Boards Under Icepak

Enhanced Stripline Scanning Array B.M. Cahill and J.C. Batchelor

How to choose the very best connectors for your speaker cables and enjoy superb sound from your music system

Injection moulding and modelling on a micro scale

Linear DC Motors Magnetic Flux Permanent Bar Magnets

Information about the T9 beam line and experimental facilities

BRUSHHOLDERS AND THE PERFORMANCE OF CARBON BRUSHES

Vehicle Design Summit Electric Hub Motor (V2) Eric Conner Harvey Tang Matthew Peddie

Tensile Testing of Steel

Integration of a fin experiment into the undergraduate heat transfer laboratory

Undulators at PETRA: Experience and Perspectives

Etch Drawing Preparation

Cross section, Flux, Luminosity, Scattering Rates

SLOT FRINGING EFFECT ON THE MAGNETIC CHARACTERISTICS OF ELECTRICAL MACHINES

Examples of magnetic field calculations and applications. 1 Example of a magnetic moment calculation

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

Module 2 GEARS. Lecture 3 - INVOLUTE SPUR GEARS

The BESSY HOM Damped Cavity with Ferrite Absorbers. Review of prototype cavity test results, taperedwaveguidesvshomogenouswaveguides

HIGH SPEED PERMANENT MAGNET SYNCHRONOUS MOTOR / GENERATOR DESIGN FOR FLYWHEEL APPLICATIONS

Testing the In-Memory Column Store for in-database physics analysis. Dr. Maaike Limper

A Study of a MV Cable Joint

Direct Attach Cable with Micro Coaxial Wire for Data Center

A new extraction system for the upgraded AIC-144 cyclotron

Frequency Map Experiments at the Advanced Light Source. David Robin Advanced Light Source

AP Physics 1 and 2 Lab Investigations

Objectives. Capacitors 262 CHAPTER 5 ENERGY

Bending, Forming and Flexing Printed Circuits

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Solid shape molding is not desired in injection molding due to following reasons.

Engineering & Design: Coordinate Dimensioning

Optical Digitizing by ATOS for Press Parts and Tools

1150 hp motor design, electromagnetic and thermal analysis

XI / PHYSICS FLUIDS IN MOTION 11/PA

Calculation of Eigenmodes in Superconducting Cavities

High Power Neutral Beam Injection in LHD

Modern Physics Laboratory e/m with Teltron Deflection Tube

Part 4 fitting with energy loss and multiple scattering non gaussian uncertainties outliers

NetShape - MIM. Metal Injection Molding Design Guide. NetShape Technologies - MIM Phone: Solon Road FAX:

Optimization of Support Point Locations and Force Levels of the Primary Mirror Support System

A complete software package for transformer design optimization and economic evaluation analysis

The DC Motor/Generator Commutation Mystery. Commutation and Brushes. DC Machine Basics

SAMPLE TEST PAPER - I

1. A wire carries 15 A. You form the wire into a single-turn circular loop with magnetic field 80 µ T at the loop center. What is the loop radius?

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

*Currently employed at UTAS, work for this paper was carried out while the author was formerly employed at MSC Software.

* This work is an official contribution of the National Institute of Standards and Technology and

Conceptual: 1, 3, 5, 6, 8, 16, 18, 19. Problems: 4, 6, 8, 11, 16, 20, 23, 27, 34, 41, 45, 56, 60, 65. Conceptual Questions

The Determination of Uncertainties in Charpy Impact Testing

KNOW YOUR OPTIONS: 230 KV POWER CABLES

Development of Ultra-Multilayer. printed circuit board

MECHANICS OF SOLIDS - BEAMS TUTORIAL 1 STRESSES IN BEAMS DUE TO BENDING. On completion of this tutorial you should be able to do the following.

Formula. = base of natural logarithms. = friction factor of the ropes in the grooves. = angle of wrap of the ropes on the traction sheave (radians).

Flux Conference High Efficiency Motor Design for Electric Vehicles

Force on Moving Charges in a Magnetic Field

Transcription:

Lecture VI Magnetic Design Field Quality Adjustment After Construction (or After the Start of Production Run) Ramesh Gupta Superconducting Brookhaven National Laboratory US Particle Accelerator School University of California Santa Barbara June 23-27, 2003 USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 1 of Lecture 6

A Flexible Design Approach Conventional Approach: Fix design parameters as soon as possible. Alternate Approach: Develop a flexible design that can accommodate variation in parts, etc. It also allows variations in design (for example, as requested by accelerator physicists) It assures a good field quality during the production while maintaining the schedule and cost. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 2 of Lecture 6

Another Related Subject Adjustment After Construction Some time, it is more efficient to find ways make small adjustments, then to iterate the original design to achieve the desired field quality. Moreover, in magnets that require very high field quality, some adjustments or tuning may be essential to overcome the errors due to tolerances in parts and manufacturing. Developing a magnet design that allows such adjustments is more likely to achieve desired field quality and may also be more cost-effective, in overall sense. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 3 of Lecture 6

Feedback in design from HERA experience: The Real Magnet Vs. Paper Design Note: Integral B.dl Note: Sextupole Parameters do deviate from nominal value. It takes time to locate the cause of the problem and then fix it (conventionally that included a cross section iteration). Takes too long and the magnet production can not stop. An alternate design strategy accommodate such variations. Make a flexible design that assures good field quality despite such deviations. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 4 of Lecture 6

Feedback in design from HERA experience A Method to Adjust Integral Field and Skew Quad Iron laminations were successfully used in RHIC to adjust transfer function saturation in different length magnets and to control skew quad in main dipoles. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 5 of Lecture 6

What happens in a typical first magnet? 1. Pre-stress (and/or effective cable thickness) is not right by a significant amount. An attempt to get right compression messes up field quality. 2. Higher order harmonics are OK but lower order are not (generally first two). Need 1+2 = 3 parameters to fix the above three quantities. But usually we are almost there: measured harmonics are 10-3 instead of required 10-4. And corresponding relative mechanical errors are small as compared to the overall coil dimensions. What is generally done? Change cross-section (change wedges, cable size, coil tooling, etc.) which makes mechanical changes relatively large. As a result the process becomes time consuming and expensive and due to a large change it does not always converge in one iteration. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 6 of Lecture 6

What was done in RHIC Insertion dipoles? Approach used in RHIC insertion dipoles for faster progress (Goal: attempt to make the first magnet itself a field quality magnet): A flexible design (opposite to fixing parameters ASAP). Geometric: midplane caps, pole shims and wedge insulation. Saturation control: Holes in the iron, later filled with iron rods. Moke up model showed wrong pre-stress and harmonics, as usual. Fixed in the first magnet assembly itself and obtain the desired pre-stress and small body harmonics. Used the adjustments (as planned and outlined above). The above adjustments were further used in later magnets for compensating end harmonics and for reducing measured current dependence (saturationinduced) in harmonics. The above adjustments are faster and cheaper than normal cross-section iterations. The coil cross-section was specified before the first magnet was tested and was never changed during production. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 7 of Lecture 6

Design Philosophy: A Flexible Design from the Beginning pole Start out a design from the beginning itself, that allows significant adjustability for field harmonics and mechanical parameters (cable thickness, wedges, etc.). Insulation A flexible design is generally economical, efficient and produces magnets with better performance. I think it s a prudent approach. midplane Geometric: Start with a larger than required shim and midplane cap. Then adjust it, as required without changing the cross-section of the cured coil. One can also adjust the layers of wedge/cable insulation, if needed. These three parameters can adjust, first two allowed harmonics and pre-stress or cable insulation. This approach was used extensively in various RHIC magnets. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 8 of Lecture 6

RHIC 100 mm Aperture Insertion Dipole: The first magnet gets the body harmonics right Geometric Field Errors on the X-axis of DRZ101 Body First magnet and first attempt in RHIC 100 mm aperture insertion dipole A number of things were done in the test assembly to get pre-stress & harmonics right dby/bo 5.E-04 4.E-04 3.E-04 2.E-04 1.E-04 0.E+00-1.E-04-2.E-04-3.E-04-4.E-04-5.E-04 Field Error Profile on the midplane at an Intermediate Field -80-60 -40-20 0 20 40 60 80 Percentage of Coil Radius Note: Field errors are within 10-4 at 60% of coil radius and ~4*10-4 at 80% radius. Later magnets had adjustments for integral field and saturation control. The coil cross-section never changed. Harmonics at 2 ka (mostly geometric). Measured in 0.23 m long straigth section. Reference radius = 31 mm b1-0.39 a2-1.06 b2-0.39 a3-0.19 b3-0.07 a4 0.21 b4 0.78 a5 0.05 b5-0.05 a6-0.20 b6 0.13 a7 0.02 b7-0.03 a8-0.16 b8 0.14 a9-0.01 b9 0.02 a10 0.01 b10-0.04 a11-0.06 b11 0.03 a12-0.01 b12 0.16 a13 0.06 b13-0.03 a14 0.03 b14-0.10 a15 0.02 All harmonics are within or close to one sigma of RHIC arc dipoles. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 9 of Lecture 6

Impact of Cable Thickness on Field Quality Basic Analysis: A thicker cable makes bigger coils, as measured outside the magnet (though coil size can be controlled by adjusting curing pressure). However, inside the magnet, the collars determine the coil geometry. Right half of the coil Cable thickness has a major impact on the pre-stress on coils. But to a first order, it does not have a major impact on field errors for a reasonable deviations in insulated cable thickness (the prestress variation will become a bigger issue before the harmonics). Rapid variations in cable thickness are averaged out over a large number of turns and over the length of magnet. The location of midplane determines skew harmonics. Though the overall cavity is well defined by collars, the location of coil midplane is not. It is determined by the relative size of upper and lower coils. If coils are matched, the coil midplane and the magnet midplane will also match. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 10 of Lecture 6

Practical Challenges: Started out with ~ 1 mil (25 µm) uncertainty in insulated cable thickness. The RHIC IR Quadrupoles (A Flexible Design from the Beginning) Fixed Rectangular Wedge Total ~27 mils (order of magnitude more than the typical 2 mil) in overall coil dimensions for 27 turns. Conventional Approach : Fix cable first. Fixed Alternate Approach : A field quality design that can absorb this. Developed a design in which all of the difference was absorbed in a rectangular wedge! No change in pole angle means: No change in coil curing press No change in collar/spacer No change in first allowed harmonic (b 5 ) USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 11 of Lecture 6 Coil Cross section of the 130 mm aperture RHIC insertion quadrupole

Different Size Cable (within spec) from Two Different Vendors Specifications : +/- 0.25 mil (6.5 micron); 0.5 mil variation (13 micron) Two vendors gave cable which differ systematically (but within specifications) by ~ 0.35 mil (however, had a small RMS) 27 turns => 9 mil (0.24 mm) much larger than desired. A flexible design accommodate it! USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 12 of Lecture 6

Flexible Design (Adjustment in b 5 During Production in Q1) Design Changes/Adjustments During Production δb5 (at 40 mm) 3 2.5 Design#1 2 Design#4 1.5 Design #3 1 0.5 0-0.5-1 -1.5-2.5-2 Design#2-3 102 104 106 108 110 112 114 116 118 120 122 124 126 128 Magnet Number b5 Errors before Tuning Shims b5 Errors after Tuning Shims USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 13 of Lecture 6

Importance of Field Quality in RHIC Interaction Region Quad USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 14 of Lecture 6

Expected Field Quality in Superconducting Magnets The field quality in interaction region magnets may significantly influence the ultimate luminosity performance of modern high energy collider such as RHIC. The field quality in any magnet depends on: The design The errors in parts used (practical tolerances) The Manufacturing process In most magnet, they produce a cumulative errors of 25-50 micron These mechanical errors translates to a relative field errors of 10-4. To overcome, these basic magnet, manufacturing errors, one must apply correction after construction. The RHIC Tuning shim method, reduces the field errors to a few parts in 10-5. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 15 of Lecture 6

Basic Principle of Harmonic Correction by Tuning Shim If a magnetic material (shim) is placed in the aperture of the magnet, it will get magnetized. This will distort the field. The distortion from the nominal field can be expressed in terms of harmonic coefficients. Use these harmonics to cancel out the measured harmonics. A properly chosen size and location of n magnetic shims can compensate n non-zero measured harmonic coefficients. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 16 of Lecture 6

Advantage of Tuning Shims The tuning shims achieve field quality in superconducting magnets significantly better than what is expected from normal manufacturing errors. They are relatively easy to implement. They correct the field errors in the magnets, where it is and therefore may be more efficient than the global and lumped corrector. This difference is important in low beta optics where the beam size changes rapidly in the interaction region. Lower field error may reduce the coil aperture, which in turn may increase the field gradient for a given maximum field in the coil. For best efficiency, the tuning shim should be considered as an integral part of the design and should be incorporated from the beginning. Since the maximum luminosity is desired at the top energy, the shim should be tuned at that field. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 17 of Lecture 6

15 Harmonic Correction As A Function Of Tuning Shim Thickness These are the changes in harmonics relative to the "no shim" or "zero iron thickness" case for each shim. The eight symbols represent the measurements for the eight tuning shim locations and eight lines are the calculations for these locations. 15 10 10 Delta-a2 (units) 5 0-5 Delta-b2 (units) 5 0-5 -10-10 -15 0 1 2 3 4 5 6 7 Shim Thickness (mm) -15 0 1 2 3 4 5 6 7 Shim Thickness (mm) 6 4 5 4 3 Delta-a3 (units) 2 0-2 Delta-b3 (units) 2 1 0-1 -2-4 -6 0 1 2 3 4 5 6 7 Shim Thickness (mm) -3-4 -5 0 1 2 3 4 5 6 7 Shim Thickness (mm) USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 18 of Lecture 6

Tuning Shims for 10-5 Field Quality at 2/3 of coil radius GOAL : Make field errors in magnets much smaller than that is possible from the normal tolerances. Basic Principle of Tuning Shims: Magnetized iron shims modify the magnet harmonics. Eight measured harmonics are corrected by adjusting the amount of iron in eight Tuning Shims. Iron Brass Procedure for using tuning shims in a magnet: 1. Measure field harmonics in a magnet. Tuning Shim 2. Determine the composition of magnetic iron (and remaining non-magnetic brass) for each of the eight tuning shim. In general it would be different for each shim and for each magnet. 3. Install tuning shims. The tuning shims are inserted without opening the magnet (if the magnet is opened and re-assembled again, the field harmonics may get changed by a small but a significant amount). 4. Measure harmonics after tuning shims for confirmation. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 19 of Lecture 6

<b n > at 40 mm 1.00 0.50 0.00-0.50-1.00 Mean Before Shim (W) After Shim (5 ka) 2 3 4 5 6 7 8 9 Harm onic Number (b n ) Field Quality Improvements with Tuning Shims (Normal Harmonics) Befor Shim(W) After Shim (W) After Shim (5kA) σ(b n ) at 40 mm 10.00 1.00 0.10 0.01 Standard Deviations Before Shim (W) After Shim (5 ka) 2 3 4 5 6 7 8 9 Harm onic Numbe r (b n ) LOG SCALE Befor Shim(W) After Shim (W) After Shim (5kA) <b n > (n=2 is sextupole) σ(b n ) n Befor Shim(W) After Shim (W) After Shim (5kA) Befor Shim(W) After Shim (W) After Shim (5kA) 2 0.41 0.01 0.05 1.74 0.41 0.56 3 0.87-0.76 0.08 1.19 0.60 0.49 4 0.06 0.03-0.17 0.42 0.20 0.27 5-0.07 0.00 0.05 0.78 0.78 0.36 6 0.01 0.05 0.05 0.11 0.21 0.18 7-0.26-0.07-0.14 0.04 0.17 0.14 8 0.00 0.01 0.04 0.03 0.04 0.06 9-0.03-0.30-0.14 USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 0.17 0.18 0.19 Slide No. 20 of Lecture 6

The best in field quality with tuning shims A few parts in 10-5 at 2/3 of coil radius Field Quality in RHIC Insertion Quadrupoles Improvements in field errors with tuning shims: Summary of field quality in QRK magnets (With Shims: only magnets since the sextant test included) Harmonics in units at 40 mm (0.615 x coil radius) 1.00 Before Shim n <b n> (n=3:sextupole) σ (b n) No Shims Shims (W) Shims (5kA) No Shims Shims (W) Shims (5kA) 17 Magnets 10 Magnets 8 Magnets 17 Magnets 10 Magnets 8 Magnets 3 0.58-0.17 0.30 1.87 0.47 0.27 4-0.11-1.21 (a) 0.02 0.56 0.23 0.17 5-0.18 0.05-0.12 0.40 0.13 0.16 6 2.68 0.48 (b) 0.59 (b) 0.37 0.08 0.07 7 0.01 0.02-0.01 0.09 0.25 0.24 8-0.25-0.11-0.14 0.05 0.09 0.08 9-0.02-0.02 0.01 0.03 0.02 0.04 10-0.10-0.32-0.20 0.07 0.03 0.03 11 0.00 0.00 0.01 0.01 0.02 0.02 (a) Non-zero mean to account for warm-cold difference and saturation. (b) Non-zero mean to account for lead end effects. <a n> (n=3:sextupole) σ (a n) n No Shims Shims (W) Shims (5kA) No Shims Shims (W) Shims (5kA) 17 Magnets 10 Magnets 8 Magnets 17 Magnets 10 Magnets 8 Magnets 3 1.24-0.18 0.09 1.67 0.56 0.50 4-0.38 0.04-0.01 0.88 0.27 0.26 5-0.02 0.00 0.06 0.30 0.14 0.15 6-0.21-0.07-0.13 0.12 0.05 0.04 7-0.01 0.05-0.02 0.14 0.27 0.16 8 0.01-0.01 0.00 0.10 0.12 0.13 9 0.01 0.01-0.02 0.04 0.04 0.06 10 0.05 0.05 0.05 0.01 0.02 0.02 11 0.01 0.01 0.02 0.01 0.02 0.03 bn an 0.10 0.01 1.00 0.10 0.01 After Shim 3 4 5 6 7 8 9 10 11 Harmonic Number After Shim Before Shim 3 4 5 6 7 8 9 10 11 Harmonic Number Normal harmonics << Plots for RMS errors. The Mean error in harmonics is generally lower. Note: Both Mean and RMS errors are a few parts in 10-5. Skew harmonics USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 21 of Lecture 6

SUMMARY A flexible design approach allows efficient adjustments in the design. This also permits a strong interaction between accelerator physicists and magnet scientists during the course of magnet manufacturing. Reasonable variations in parts accommodated Tolerances in parts reduced A good field quality in magnet assured Tuning shim allows significant improvement in field quality in accelerator magnets over what can be typically expected from normal tolerances in parts and manufacturing. Tuning shims may improve the ultimate luminosity performance of the machine. USPAS Course on Superconducting Accelerator Magnets, June 23-27, 2003 Slide No. 22 of Lecture 6