600-GD & 600-GDL 600 SERIES GAS DETECTOR



Similar documents
BEP FD-2 CONTOUR MATRIX FUME DETECTOR

Manual for Fire Suppression & Methane Detection System

EzFlex Combustible Gas Leak Detector Model EZ40

Advantium 2 Plus Alarm

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

Combustible Gas Leak Detector 720b

CO2 Alarm. Operation. Application

Leak Detection System

Installation Instructions for Alarm Module Kit A043F059

Passive Infrared Motion Detector 5420/90. Installation Instructions

Fire & Security DETECTORS

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Ceiling Mount Air Handler Manual

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

ADM1TE 5/30A DIN rail single phase two wire energy meter

Wireless Alarm System. Alarm Siren. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

USER S MANUAL HSC-24A

i ChatterBox! Motorcycle Security

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

TMS TANK MANAGEMENT SYSTEM

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Portable Air Conditioner

You're reading an excerpt. Click here to read official BH FITNESS T1 BASIC user guide

3000W Power Inverter

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Water Leak Detection System

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Mold Alert... Operation Manual P0270

PSTN Home Alarm System

Installation and Operating Instructions (for chargers shown below)

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

User s Information Guide R1A

MOBILE CALL GSM Alarm System User s Manual

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

StructureScan HD Module. Installation Guide ENGLISH

Intelligent GSM Auto-Dial Alarm System

AD-01 Slave Auto Dialer. Owner s Manual

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Microwave Meter. Instruction Manual

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Wireless Home Security Alarm System AM 500

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

90 Degree PIR Wireless Security Sensor. Installation Instructions 5420/90F

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

User s Manual Before using the inverter, you need to read and save the safety instructions.

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

How To Use A Power Supply Unit (Upu)

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

VK-250 WARRANTY REGISTRATION FORM

User Manual THR840DUK Digital Thermostat

Owner s Guide and Installation Instructions

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

Installation and maintenance instructions. Danfoss Vent

WD-AMX Water Detection Controllers

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

1R / 4-BUTTON SERIES

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

BL-DBK150A DUAL BATTERY 12v 150 AMP SMART SYSTEM

ELECTRIC FENCE ENERGISER

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Owner s Manual & Safety Instructions

ProScan v.1.2. Owner s Manual

T7560A,B,C Digital Wall Module

INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD

CA 1050 Owner s Guide

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

16/32 Channel 1U Rack Mount CCTV Power Supply

AIR-CONDITIONER SPLIT TYPE

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

T H A N K Y OU F O R Y OUR P U R C H A S E O F A N E S S E N T I A V A N I T Y, P L E A S E R E A D T H E S E V A N I T Y C A R E A N D I N S T A L L

Instructional & Operating Manual

14. Troubleshooting Guide

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Dual Laser InfraRed (IR) Thermometer with Color Alert

PK5500 v1.1 Installation Instructions

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Automatic Phone-Out Home Monitoring Systems

Installation Instructions

Touch Tone Controller. Model TR16A. Owner s Manual

How To Program An Autodialer

Owner s Guide. ca6554

User s Manual AURORA 1.2K/2.2K

Transcription:

600-GD & 600-GDL 600 SERIES GAS DETECTOR INSTALLATION AND OPERATING INSTRUCTIONS

This page has been deliberately left blank. Page 1

Table of Contents 1 WARRANTY...3 2 IMPORTANT...3 3 CAUTIONS WHEN USING GAS SENSORS...3 4 FEATURES...4 5 SPECIFICATION...4 6 INTRODUCTION...4 7 FAULT DETECTION...4 8 DIMENSIONS...5 9 WIRING DIAGRAM...6 10 CONTROL HEAD INSTALLATION...7 11 SENSOR INSTALLATION...7 12 OPERATION...7 13 TEST / ALARM MUTE BUTTON...8 14 BYPASS MODE...8 15 INDICATOR DISPLAY...8 16 ACCESSORIES...8 17 USER NOTES...9 Page 2

1 Warranty The warranty of this BEP MARINE LTD product is for Two Years from date of sale to original purchaser. BEP MARINE LTD does not assume the cost of removal or refitting of the product, or any other incidental cost that may arise, as the result of defect in materials or workmanship. Warranty will only be undertaken on equipment returned to either BEP MARINE LTD or their agent. The equipment will be replaced or repaired at the discretion of either BEP MARINE LTD or its agents. As long as the equipment has neither been (1) Abused (2) Wrongly connected (3) Contaminated due to neglect (4) Improper installation, (5) Used in violation of instructions supplied with equipment manufactured by BEP MARINE LTD. On return of equipment for warranty it must be accompanied with proof of purchase and not been tampered with. 2 Important It is the installer s sole responsibility to install and use this product in a manner that will not cause accidents, personal injury or property damage. Please follow the installation instructions supplied. If installation is not correct, the unit may not perform at its designed potential. If in doubt, consult your local BEP MARINE LTD dealer. BEP MARINE LTD disclaims all liability for any use of this product that may cause accidents, damage or be in violation of any laws. Copyright 2005 BEP MARINE LTD. All rights reserved. 3 Cautions when using gas sensors 1. Exposure to silicone vapours If silicone vapours adsorb onto the sensor s surface, the internal sensing element maybe be coated, irreversibly inhibiting sensitivity. Avoid exposure where silicone adhesives, hair grooming materials or silicone rubber/putty may be present. 2. Highly corrosive environment Exposure to corrosive materials such as H2S, SOx, Cl2, HCl, etc. for extended periods may cause irreversible damage to the sensor. 3. Water Sensor performance maybe adversely affected due to soaking, splashing or water condensing on the sensor surface. Exposure to salt water spray will adversely affected sensor performance. Light condensation under conditions of indoor usage should not pose a problem for sensor performance. 4. Freezing If freezing occurs on the sensor s surface irreversible damage may occur to the internal sensing element. 5. Usage in high density of gas Sensor performance maybe adversely affected if exposed to a high density of gas for a long period of time. 6. Explosive Limits Different combustible gasses have their own Lower Explosive Limits (LEL). Our gas sensors are calibrated against 20% LEL LPG in Air. 7. False positive alarms False positive alarms can be caused by differing concentrations of various aerosols, perfumes, resins, epoxies, paints, solvents, alcohol, hydrogen, gases and fuels. Page 3

4 Features The 600-GD and 600-GDL gas detectors offer the following features: - Self testing capability Microprocessor control Dual sensor capability Provision for an external alarm Provision for automatic bilge blower switching Automatic shut-off solenoid control with Pulse and Hold circuit technology for low power draw (600-GDL only) Manual override Important: Disables gas detector (600-GDL only) NOTE: The 600-GDL is designed for 12V DC systems only. For 24V installations a DCVR-4 voltage reducer must be used. 5 Specification Voltage: Current: Alarm: Current at outputs: 600GD 10V-30V DC / 600GDL 10-15V DC Total 350mA Max 20% LEL (Lower Explosive Limit) 800mA Max (per output) NOTE: If you are using a solenoid valve other than BEP s VR2. The solenoid current draw must be checked to make sure it is 800mA or less at 12.5 volts. 6 Introduction The Contour model LPG, Petrol and CNG detector is the product of continuing research and development, which BEP Marine Ltd devotes to their product range. The 600 series detectors use the latest in solid state technology available, with a microprocessor control head connected to the latest in sensor technology. The 600 series detectors have the capability to control two sensors with both visual and audible alarms. There is a test switch to check the operation of the sensors with indicators for fault detection. The 600-GDL has provision for the connection of an external alarm, bilge blower, gas on/off valve and manual override to disable faulty sensor. Read these installation and operation instructions carefully before installing, as any damage caused by faulty installation will result in the warranty being null and void. There is no power on/off switch provided in either unit. It is intended that for maximum protection the unit should be on all the time while you are on your boat or vehicle. 7 Fault Detection The nominal alarm point of the 600 series is 20% of the LEL (Lower Explosive Limit) of LPG/CNG in Air. In the event of a gas leak and the alarm activating, close the manual valve on your gas bottles and open hatches to ventilate the area. All fans and blowers used to ventilate must be ignitionprotected types. In the event of a sensor being contaminated, damaged, cable shorting or a faulty connection, the amber light will come on for the particular sensor. If the sensor fault persists then the sensor could be damaged and will need to be replaced. In detecting LPG the sensor can also detect hydrocarbons in other products such as cleaners and strong adhesives, this can cause nuisance alarms. See section 3 - Cautions when using gas sensors for more details. Page 4

8 Dimensions Copyright BEP Marine Limited, All rights reserved Page 5

9 Wiring Diagram Copyright BEP Marine Limited, All rights reserved Page 6

10 Control Head Installation Copyright BEP Marine Limited, All rights reserved For ease of operation, the control head should be mounted in a convenient position close to your gas appliances and in a position where the control head can be seen and heard easily. The unit can be either surface mounted or recessed into a 2.5mm panel. 11 Sensor Installation The sensor is supplied with a 5-meter cable. For LPG and Petrol fumes, which are heavier than air, mount the sensor in a low dry position where the gas is likely to collect. The sensor must be mounted clear of bilge water. NOTE: If the sensor gets wet then the sensor becomes inoperable and must be replaced. For CNG, which is lighter than air, mount the sensor just below ceiling height but not above cooking or heating appliances. Fasten the sensor with the supplied screws. Route the sensor cable through to the control head and connect as per the wiring diagram. 12 Operation On applying power to the unit, the control head goes through a test cycle. This will take approximately 45 seconds. During this period the sensor heads are being cleaned and tested, at this time there will be a slow beep from the audible alarm and all the lights will flash amber. Towards the end of this period the pulse of the beeper and lights will increase, if the unit senses that the environment is clear then the control head will go into safe mode. The beeper will turn off and the sensor lights will change to green. With the control head in safe mode the gas valve can be turned on and off. When on, the valve light will show red (600-GDL only). Should the control head go into alarm mode the gas valve will be automatically turned off (600-GDL only). A red light will indicate which sensor has detected gas and the alarm will beep quickly. 1. Sensor #1 indicator 2. Sensor #2 indicator 3. Solenoid valve on/off indicator* 4. Solenoid valve on/off switch* 5. Test/alarm mute switch * Refers to 600-GDL features only Page 7

13 Test / Alarm Mute Button Copyright BEP Marine Limited, All rights reserved When the TEST button is pressed in normal operation mode it will - Turn on the external alarm Turn on the blower Turn off the solenoid Sounds the keyboard beeper Turn light red Pressing the TEST button again cancels the above. When the unit is in alarm mode, pressing the TEST button will turn off the external alarm but the keyboard alarm will continue to sound. The detector will stay in alarm mode until the gas disperses. 14 Bypass Mode This is a 600-GDL feature only. Bypass mode disables the sensors. It is important to note that the bilge blower and external alarm features of the 600-GDL are also disabled. To achieve bypass mode press and hold the TEST button for approximately 15 seconds until the sensor LEDs start to flash (green or amber). The sensor LEDs will then continue to flash (1 sec on, 1 sec off) to indicate that the sensor(s) are in bypass mode. Once the fault has been rectified, press and hold the TEST button until the VALVE ON LED comes on. Bypass mode is turned off when the button is released. The 600-GDL will then automatically reset itself and test the sensor(s). 15 Indicator Display VALVE ON INDICATOR Red: Off: Solenoid valve on Solenoid valve off SENSORS #1 AND #2 Green: Sensor on safe, no fumes, no beeping Green flashing: Bypass mode with sensor disabled - Sensor on safe, no fumes, no beeping Amber: Sensor fault detected, slow beeping Amber flashing: Bypass mode with sensor disabled - Sensor fault detected. Red: Alarm. Gas present, fast beeping AUDIBLE ALARM SOUNDS Warming up: Alarm: Fault: Medium slow, all lights flash amber Fast, sensor lights red Slow, sensor lights amber 16 Accessories VR2: Solenoid control valve 53-2764: Remote Alarm SL-L: Sensor and Lead DCVR-4 Voltage reducer NOTE: The 600-GDL is designed for 12V DC systems only. For 24V installations a DCVR-4 voltage reducer must be used. Page 8

17 User Notes Page 9

This page has been deliberately left blank. Page 10

BEP MARINE 13 Tarndale Grove Albany, Auckland, N.Z. Ph: +64 9 415 7261 Fax: +64 9 415 9327 www.bepmarine.com BEP AUTOMOTIVE 13 Tarndale Grove Albany, Auckland, N.Z. Ph: +64 9 415 7261 Fax: +64 9 415 9327 www.bepautomotive.com E-mail: enquiries@bepmarine.com Please visit our website for the latest International Distributor List Page 11