24 Hour Mechanical Time Switch

Similar documents
OPERATING INSTRUCTIONS

Fused Spur Time Switch

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

5W LED Energy Saver PIR Bulkhead

Wireless 7 Day Programmable Room Thermostat

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

Installation & User Instructions

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Operating Instructions. Room temperature controller

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

CR9986 ROBERTS. Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use

2400W PIR LIGHT C O N T R O L L E R Cat No. SLW2400

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

INFRARED QUARTZ WALL HEATER

GB/DAS User Instruction

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

INSTANT HOT WATER RECIRCULATING SYSTEM

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

EBDSPIR-PRM, EBDSPIR-PRM-IP

Drayton Digistat +2RF/+3RF

HERZ-Thermal Actuators

WARNING: Important: Keep these instructions for future reference. Gate Instructions (1) Assembly and Installation Instructions

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Model 201 Wiegand Touchpad Reader Installation Guide

Electric Rotary Actuator - On/Off or programmable control actuator

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

100 Series Maxi Internal Filters. Instruction Manual

PS6500 Storage Arrays Rack Mount Instructions

3 IN 1 BATHROOM HEATER

LUCCI AIRFUSION QUEST II CEILING FAN

User Operating Instructions Horstmann 425 Coronet Electro-mechanical Timeswitch

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

Permanent Magnet Motor Kit, Magnetic Reed Type. (SKY-ReedMotorKit) Instructions

Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty

REDWALL-V adjustment procedures guide

Enterprise Telephone. Model OPERATING INSTRUCTIONS

Single Channel Loop Detector

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Chill 4 Hole Bath Shower Mixer

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

IH E Sigma Island 90

INSTALLATION INSTRUCTIONS

EBDSPIR-DD, EBDSPIR-DD-IP

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Power Socket (2 Gang)

Aerona Air Source Heat Pumps

Installation Instructions. Thermo Call TC3

Installation Guide. DEVIreg 530. Electronic Thermostat.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Solid State Timers Type F

How To Set Up An Inverter

TerraWave Solutions MIMO Site Survey Battery Pack (Part # TW-SSBP-007) Instructions For Use

User's Instructions. Alpha HE CB25/33 and HE SY25

Original Assembly Guide

LED Security Spotlight User Manual

12-Volt Negative Ground Installation Instructions

HP UPS R1500 Generation 3

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

5800 Temperature Sensor Cable Assembly

Product and functional description

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

MTX-D, Oil Temperature/Pressure Gauge

MIC-WKT and MIC-WKT-IR

LED MOTION ACTIVATED FLOOD LIGHT

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

TRIMBLE TX5 3D LASER SCANNER QUICK START GUIDE

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Converse 320. Userfriendly Guide

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

OPERATING INSTRUCTIONS

V94 BULK TAPE DEGAUSSER

Installation Guide Smart-UPS X Tower/Rack-Mount 2U 2000/2200/3000 VA

Article: Version:

Serial ATA to Serial ATA

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

HM-W536 Install Guide

S03, S05 Series Low-Torque Spring- Return Direct-Coupled Actuators

Meaco 30L and Meaco 40L dehumidifier instruction manual

INSTALLATION AND OPERATION MANUAL

Operating Manual Color Changing Fountains

Laserlyte-Flex Alignment System

INDEPENDENT HOBS WITH HIC ELECTRONIC CONTROL

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

Transcription:

24 Hour Mechanical Time Switch Model: NTT01 Immersion Timer Installation & Operating Instructions

NTT01 Immersion Timer Power LED Output LED (NTT01 only) Programme ring Bezel fixing screws ON segment Bezel Time indicator 1 Time control segments: 1 segment = 15 minutes, push segment down for on, pull up for off. Control switch: 1 = permanently on, Timer symbol = timed control, 0 = permanently off. 1. General: This time switch is a compact and easy to use segment timer, which fits on a single gang wall box. It can control outputs of up to 16A which makes it suitable for domestic immersion heaters. 2. Features: Permanent On/Off facility. This enables the heater under control to be turned off when alternative methods of heating are available, or during a holiday period. It also enables the heater to be permanently turned on. Shortest switching time of 15 minutes increasing in 15 minute steps. Up to 48 programmes per day.

2 3. Installation: We recommend that this unit be fitted by a qualified electrician. Install in accordance to wiring and current building regulations. Please read the instructions carefully. If in any doubt contact the Timeguard Helpline. Important: Switch off mains electricity before commencing work. Remove the two bezel fixing screws, and remove bezel from timer module and back plate. Separate the timer module from the back plate, and remove the wall fixing screws. Ensuring that the free terminals on the back plate are at the top, connect the installation wiring to the terminal block, according to the legend on the wiring label. The earth wires should be connected to the wall box earthing terminal, or should be connected together using a single way connector block if there is no suitable earth terminal in the back box. Fit the wall mounting screws through the back plate into the wall box threaded holes, and tighten until the back plate is firmly fastened. Fit the timer module to the back plate, ensuring the time indicator is on the bottom right hand side, and the locating holes on the timer are set correctly on the pegs on the back plate. Fit the bezel over the timer module, and secure to the back plate with the two screws provided.

For other wiring, the terminals are marked as follows: L Live supply. N Neutral supply. N OUT Neutral to immersion heater. SL Live output to immersion heater. 3 4. Programming the time switch: a) Decide what times you would like the time switch to switch ON and Off. b) Push the required segments down for the duration of an on period, and pull them up for the duration of an off period. The minimum switching interval is 15 minutes, and this can be increased in 15 minute steps. c) Set the correct time, by rotating the dial clockwise until the correct time is indicated by the triangular pointer. Note that as the dial is rotated there will be an increased resistance to turning as on/off periods are passed. Points to note: The segment dial can be turned whilst the time controller is operating. In case of power failure, re-adjust the time controller to the correct time of day by turning the dial in a clockwise direction until the correct time is indicated by the pointer.

5. Permanent Override: The main slider on the timer can be set to permanent on by sliding it to the left, aligning the arrow head to the 1 symbol. In the middle position, with the arrow head pointing at the timer symbol, the timer is in automatic mode. If the slider is moved to the right, and the arrow head points at the 0 symbol, the timer is permanently off. 4 6. Specifications: Operating temperature: 0 C to 40 C Operating voltage: 230V 50Hz Switch rating: 16A resistive, 6A inductive Minimum depth of wall box: 32mm Switch type: 22A micro switch Voltage free contact: No Contact type: Normally open Power on light: Yes Output Light: Yes Time period: 24 hours Note: Product not suitable for discharge lighting.

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. for years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515. Note: a proof of purchase is required in all cases. for all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside the UK. All shipping costs are to be paid in advance before a replacement is sent. For assistance with the product please contact: HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com 67.058.475 (issue 3). Zerofour April 2013