Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Similar documents
CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

HERZ-Thermal Actuators

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Three-phase monitoring relay CM-PFE

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Drayton Digistat +2RF/+3RF

RRV934. Multi-controller. Synco living

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Adjustable room thermostat for heating only or cooling only systems

Actuator-Sensor-Interface

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Heating Controller. Building Technologies HVAC Products

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Thermistor motor protection

Type: DILM32 10(24V50HZ) Article No.:

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Thyristor power units and Solid state contactors. TC2000 series. Two-phase control of a three-phase load or control of two single-phase loads

Quick Connect. quick - simple - efficient.

Power Supplies 3. SDN-P DIN Rail Series

Relés e Contatores de Estado Sólido SIRIUS

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

CompactLogix Power Supplies Specifications

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Type: DILM9 10(24VDC) Article No.:

Safety technique. Emergency stop module BO 5988 safemaster

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

is then retained absolutely without interruption.

Digital input modules

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Product and functional description

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

RM4TG20 three-phase network control relay RM4-T - range V

HCR3.2/.. Chipcard reader HOTEL SOLUTION

E-STOP relays, safety gate monitors

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Electronic Control Devices The European Product Catalogue 2007

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Redundancy Module QUINT-DIODE/40

R.C.C.B. s two-pole LEXIC

Solid State Relays for Heaters

Cross-beam scanning system to detect slim objects. 100 mm in

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF19 and EF45

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Operating Manual UWAPS-TINY Series

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

CQM1-SF200/CS1W-SF200

How To Select A Solid State Relay For A Three Phase Resistive Load

Unified requirements for systems with voltages above 1 kv up to 15 kv

Electronic overload relay EF65, EF96 and EF146

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

OZW30. Central Unit SYNERGYR

Installation and User Guide

Thyristor-controlled power supplies and battery chargers

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

Energy Management Energy Meter Type EM23 DIN

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Flush-mounted room thermostats

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Controls Solid-State Switching Devices

Material test chamber with mechanical convection

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Waveguide Access Point WGA631. Product Guide

Digital inductive conductivity transmitter

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

J TB/TW Temperature limiter, temperature monitor

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

PHOENIX CONTACT Features

Transcription:

4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and air conditioning plant, e.g.: Electric heating coils Fan coil units Induction units Electric radiators Electric underfloor and ceiling heating systems Reheaters in fan coil units and supply air ducts Convector heaters and panel heating The current valves are designed to switch the following resistive loads: oad voltage Minimum switching capacity 1) Maximum switching capacity 2) 1 x AC 230 V 0.04 kw 5.75 kw (= 25A) 1 x AC 400 V 0.06 kw 10.0 kw (= 25A) 1) Used for sizing the load; has nothing to do with controllability 2) The maximum switching capacity applies to single-phase applications. For higher switching capacities, see connection diagrams 1 4. CM1N4937en 14.01.2004 Siemens Building Technologies Building Automation

Ordering When ordering, please state the quantity, product name and type code, e.g. 10 Current valves Type SEA45.1 Compatibility The current valves can be controlled by any device capable of delivering one of the following control signals: AC 24 V pulse/pause control signal Proportional DC 0 10 V control signal 1) On/off control signal, DC 0 or 10 V 1) 1) Requires conversion into an AC 24 V pulse/pause control signal. The SEM61.4 signal converter is available for this purpose (see data sheet 5102). Technical design The current valve is a solid-state power switch (thyristor). It regulates the amount of electrical energy supplied to the connected heating element. The output power is determined by the AC 24 V pulse/pause control signal. It is switched at the zero-voltage crossing point, in order to avoid the introduction of mains interference. The control signal and power signal are electrically isolated (by opto-coupler), enabling the controller and the current valve to be powered by different phases. Mechanical design The current valve consists of a black aluminum heat sink (with four channels for heat dissipation) suitable for mounting on a DIN rail. A plastic housing accommodating the electronic circuit and connection terminals is snap-mounted onto this base. The underside of the baseplate has a snap-on facility for fixing the current valve to a DIN rail. The printed circuit board is not encapsulated. In fact, it is actually ventilated by thermal convection through the unused terminal cavities. The front plate of the electronics housing accommodates the type label and an electrical diagram to assist with wiring. An operating diagram is printed on the side of the electronics housing, showing the maximum permissible load current as a function of the ambient temperature. ED display An ED located below terminal (above the relay symbol) lights up when the control signal is "ON". Engineering The equipment must be installed in such a way as to ensure that the permissible ambient conditions are maintained. Ensure adequate ventilation especially when installing current valves in control panels. The maximum permissible load current (effective value) is dependent on the ambient temperature. At temperatures above 40 C the load current must be reduced (see diagram): 2/8

I [A] 30 25 20 10 1 T 20 10 0 10 20 30 40 50 60 70 [ C] 4936D01 I T oad current (effective value) Ambient temperature In control panels or fan coil units where the ambient temperature during operation exceeds 40 C, a fan must be provided for bottom-to-top ventilation. Warning: The graph below shows the quantity of heat to be dissipated as a function of the load current. It serves as a basis for calculating the cooling requirements. 30 25 Power dissipation [W] 20 15 10 5 0 0 5 10 15 20 25 30 oad current [A AC] Mains voltage tolerances must be included in load calculations. The maximum allowable load current of 25 A must not be exceeded. The rated current of the connected heating element must not be lower than the minimum load current of the current valve (see "Technical data"). The load input (terminal ) may only be fused with fast-acting fuses: 25 A (I 2 t <6600 A 2 s). The system voltage and load voltage may have different phases. At least one thermal cut-out must be provided for protection of a heater battery. This must not be interlocked with the current valve on the control side: instead, it should cut off the power supply to the heating element, either directly or via a switching contactor. Heater batteries must not be fitted with short-circuit high-temperature cut-outs. The heat sink may be earthed. Warning: Under normal operation, the heat sink may become very hot (approx. 90 C). Personnel must be warned to avoid touching the heat sink during or directly after operation. Maintained a safe distance from cable ducts. The following minimum clearance between the current valve and other devices must be maintained: 10 mm on either side of the current valve 100 mm above the current valve 20 mm below the current valve 3/8

Mounting and installation Mounting location: on wall or in control panel, with forced ventilation precautions where necessary. Mounting method: snap-mounting on DIN rail ocal electrical installation regulations must be observed. Mounting instructions are supplied with the current valve. Warning: Always install current valves so that the cooling fins are vertical. Forced ventilation of the control panel must be from bottom to top only, to support natural convection through the heat-sink cooling channels. Forced ventilation must not be directed horizontally at the devices, as this can impede natural convection through the cooling channels. Current valves must not be installed one above the other. 01539 C 1... 23 W! 01900 01538 A 100 mm 10 mm 10 mm 20 mm 4/8

Technical data Control side Control voltage (SEV) (Terminal, ) AC 24 V ± 20 % Frequency 50/60 Hz Power consumption (AC 24 V) 0.5 VA Control signal voltage (pulse/pause) AC 24 V (Terminal ) Switch-on voltage Switch-off voltage AC 18.5 V AC 6 V oad side Mains voltage (terminal, ) AC 42 660 V Frequency 50/60 Hz Current, I eff at 40 C 1) Max. 25 A 1) Min. 0.15 A Power 0.04... 5.75 kw (230V) Power 0.06... 10 kw (400V) Power loss across thyristor 1... 23 W eneral device data Switching action Zero voltage switch Max. cable length (terminals and ) for 300 m 0.6 mm diameter Cu cable Connection terminals on control side Max 1 x 4 mm 2 Connection terminals on load side Max 1 x 25 mm 2 Insulation resistance Control circuit load circuit oad circuit heat sink AC 4 kv AC 4 kv Housing protection standard IP 20 to EN 60 529 Protection class II to EN 60 730 Ambient conditions Normal operation Transport IEC 721-3-3 IEC 721-3-2 Environmental conditions Class 3K5 Class 2K3 Temperature 1) 5...+70 C 1) 25...+70 C Humidity (avoid condensation) 5...95 % rh Humidity <95 % rh Mechanical conditions Class 3M2 Class 2M2 Electromagnetic Emitted interference EN 61000-6-4 compatibility Interference immunity EN 61000-6-2 compliance Meets the requirements for CE marking in EMC directive 89/336/EEC ow voltage directive 73/23/EEC Approval U and CSA compliant Product standards ow-voltage switchgear and controlgear Part 1: eneral rules EN 60 947-1 Part 4-3: AC semiconductor controllers EN 60 947-4-3 and contactors for non-motor loads Weight Weight excluding packaging 0.360 kg 1) At temperatures above 40 C, the load current must be reduced, see page 3. Connection diagrams Connection diagram 493601 System voltage on control side (SEV) AC 24 V AC 24 V pulse/pause control signal Mains potential AC 42 660V oad (resistive) 5/8

Field connection diagrams Connection diagram 1 The following field-connection diagrams show only the basic connection of the current valves. The diagrams do not show switch-off functions and overrides. These depend on the plant and can vary from system to system. SEA45.1 with and without signal converter: 1-wire connection plus neutral conductor for AC 42 230 V with 1, 2 and 3 current valves phases loaded asymmetrically. With signal converter Without signal converter 01792 1 2 3 0 N1 0 E U1 / 0 BO N2 N 0 2 3 5.7 kw 5.7 kw 5.7 kw 4 5.7 kw 1 x AC 230 V, 5.7 kw 2 x AC 230 V, 11.4 kw 3 x AC 230 V, 17.1 kw Connection diagram 2 SEA45.1 with and without signal converter: 2-wire connection for AC 42 400 V with 1, 2 and 3 current valves phases loaded asymmetrically With signal converter Without signal converter 01793 1 2 3 0 N1 0 E U1 / 0 BO N2 2 3 4 0 10 kw 10 kw 10 kw 10 kw 1 x AC 400 V, 10 kw 2 x AC 400 V, 20 kw 3 x AC 400 V, 30 kw 6/8

Connection diagram 3 (standard circuit) SEA45.1 with signal converter: 3-wire connection for AC230 V or AC 400 V symmetrically loaded phases. 1 2 3 01794 E 0 N1 0 U1 2 3 N 0 1 ) 3 x AC 230 V, 10 kw 2 ) 3 x AC 400 V, 17,1 kw Connection diagram 4 (economy circuit: CAUTION: Observe all national regulations! SEA45.1 with signal converter: 3-wire connection for AC230 V or AC 400 V symmetrically loaded phases. 1 2 3 E 01795 0 N1 0 U1 2 0 3 x AC 230 V, 10 kw 2 ) 3 x AC 400 V, 17.1 kw Key to connection diagrams 1 4 N1 Control unit (e.g. controller) with DC 0 10V or DC 0/10 V output signal N2 Control unit (e.g. controller) with AC 24 V pulse/pause output signal U1 Signal converter SEM61.4 4 Current valve SEA45.1 K Safety "chain", e.g. safety thermostat and high-temperature cut-out Very fast-acting fuse F Overcurrent trip 1) Star point can be connected to N 2) Valid for a voltage of AC 230 V across the conductors 7/8

Dimensions Dimensions in mm 12.5 5 01901 94 81.7 102.6 45 51.8 46.4 103 8/8 2004 Siemens Building Technologies td. Subject to change