CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN 13501-1:2007



Similar documents
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN : 2007

Fire Test Laboratory

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

Master Panel 1000 W Wall

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

BRE Global Test Report

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN

Loss Prevention Standard

Dubai Municipality Standard DMS 1: Part 5: 2004

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Master Panel 1000 R5 Roof

Classification of reaction to fire of glass products Recommendation from Glass for Europe

Loss Prevention Standard

RPV - RP - RA air handling units

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

A new approach to the Danish guidelines for fire protection of combustible insulation

Test Report: ICL/H11/979. BS 7837: 1996 Flammability performance for textiles used in the construction of marquees and similar textile structures.

Technical Specifications BIO-BLOK 80 HD G

FIRE BEHAVIOR CERTIFICATION OF THERMAL INSULATION MATERIALS

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Composite Panel Firewall Systems

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

Fire testing for BCA compliance

CERTIFICATE OF APPROVAL No ME 5078

Report Number BTC 17755F

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Eco-Sol Ltd. Document Reference:

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

Code of Practice for fire resisting metal doorsets

Fire Life Safety ORC Review Guidelines for PPD Experimental Installations

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Technical Specification Fire Blanket Firemaster Fire Protection-Cables Tray Fire Protection Department

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

>active antimicrobial wall cladding for hygienic environments

Tremco Fire Protection Systems Group Technical Bulletin

STENCA HT PIPE. Quality Insulation made of calcium silicate.

Annex of the certificate (Page 1/6) Accreditation Scope

The soot and scale problems

Light-Weight Panels. High quality panels.

STENCA PIPE. High quality pipe insulation.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Terms and Definitions In Canada

Rockwool Flexi Insulation Application Guide

Fire safety in timber buildings

Fire safety in buildings and implementation of European fire test standards

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

: ARLIN - TEXTILE WALLCOVERING

FIREPROOF Panels Trimoterm

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Testing Rules for Thermal Conductivity October 2015

Fire Testing of Recycled Materials for Building Applications

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Gurit (UK) Ltd. Document Reference:

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

TEST REPORT Page 1 of 30

sound reduction systems for commercial, educational and industrial environments

LOW COST PREFABRICATED CONSTRUCTION SYSTEM

EN Export Manager Pulastic Sports Surfaces The Netherlands

MICRO FIBER OPTIC CABLE BLOWING MACHINE WITH ELECTRIC

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Organize Sanayi Bölgesi 21.Cadde No:1 ESKİŞEHİR FAX NO: Attention : Mustafa Günay (mgunay@doganglass.com)

A few inches will give your business room to grow...

PYROSWISS VETROFLAM CONTRAFLAM

ENVIRONMENTAL PRODUCT DECLARATION as per ISO and EN 15804

Fire Safety Requirements for Child Care Centre

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Fire-rated Aluminum Doors

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

1-085 Fire safety performance of materials

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

MINIFOK MACHINES MINI FIBER OPTIC CABLE BLOWING MACHINE. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

Test report No

CPME CABLE PUSHING MACHINE WITH ELECTRIC MOTOR. fokmachine.com FIBER OPTIC CABLE BLOWING MACHINES

Morgue refrigeration unit

Quality Regulations for Profiles

PRODUCT SHEET 1 MIDLAND LEAD MANUFACTURERS LTD S CAST LEAD SHEET

18 June 2001 GUIDELINES ON FIRE TEST PROCEDURES FOR ACCEPTANCE OF FIRE-RETARDANT MATERIALS FOR THE CONSTRUCTION OF LIFEBOATS

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

furnishings flammability characteristics

Product Information. Tel: x2426 or x2443 Fax:

Test Report Nr CT-IST-00

Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports.

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Understanding BS EN 771-3: Aggregate concrete masonry units

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Passive Fire Protection

Structural fire design Eurocode Timber structures

Transcription:

ERA YÖNETİM DANIŞMANLIĞI HİZMETLERİ A.Ş. ERA Fire Test Laboratory Accredited Body tified Body : AB-00-T : 2184 CLASSIFICATION OF REACTION TO FIRE IN ACCORDANCE WITH EN 1501-1:2007 Sponsor Prepared by Product name : İZOPOLİ YAPI ELEMANLARI TAAHHÜT SAN. ve TİC. A.Ş. Çırağan Cad. :97 Ortaköy, İSTANBUL / TURKEY : ERA YÖNETİM DANIŞMANLIĞI HİZMETLERİ A.Ş. Tümsan 1. Sanayi Sitesi, 8. Blok, :25, İkitelli Organize Sanayi Bölgesi, Küçükçekmece, İstanbul, TURKEY : IZOPOLI WALL & COLD STORE PANELS Classification report. : ERA - 10-017 Issue Number : 1/2 Date of issue : 22.0.2010 This classification report consists of 5 pages and may only be used or reproduced in its entirety. Address: Tümsan 1. Sanayi Sitesi, 8. Blok, :25, İkitelli Organize Sanayi Bölgesi, Küçükçekmece, İstanbul, TURKEY Tel: 02 4862762 Fax:02 486276 E-mail:info@erayonetim.com Web: www.erayonetim.com

REACTION TO FIRE CLASSIFICATION REPORT.ERA-09-017 Page 2 1. INTRODUCTION This classification report defines the classification assigned to IZOPOLI WALL & COLD STORE PANELS in accordance with the procedures given in EN 1501-1:2007 2. DETAILS OF CLASSIFIED PRODUCT 2.1. Nature and end use application: The product IZOPOLI WALL & COLD STORE PANELS is defined as a type of classified product. Its classification is valid for the following end use application: Sandwich panel products according to the EN 14509 standard: Self supporting double skin metal faced insulating panels Factory made products - Specifications 2.2. Description: The product IZOPOLI WALL & COLD STORE PANELS is fully described in the test reports in support of the classification listed in clause. The tested product has been selected as a representing product of the following product group: SUPERLAMBRI MEGALAMBRI IZOCOLD. TEST REPORTS AND TEST RESULTS IN SUPPORT OF CLASSIFICATION.1. Test reports Name of laboratory Name of sponsor Test report ref. no. Test method İZOPOLİ YAPI ERA YÖNETİM FTST09188 TS EN 182 ELEMANLARI DANIŞMANLIĞI FTST09196 TAAHHÜT SAN. ve HİZMETLERİ A.Ş. TİC. A.Ş. FTST09192

REACTION TO FIRE CLASSIFICATION REPORT.ERA-09-017 Page.2. Test results Test method Flame exposition: 0 s TS EN 182 : t applicable (1): Surface flame attack (2): Edge flame attack Parameter Fs 150 mm(1) ignition of filter paper (1) Fs 150 mm(2) ignition of filter paper (2) FIGRA 0,2 MJ (W/s) LFS > edge THR 600 s (MJ) SMOGRA (m 2 /s 2 ) TSP 600 s (m 2 ) Number of test Continuous parameter mean (m) 92,5 4,9 6,4 22,1 Results Compliance parameters Flaming droplet(s)/particle (s) Test method Parameter Parameter TS EN 182 : t applicable (1): Surface flame attack (2): Edge flame attack Fs 150 mm ignition of filter paper Compliance parameters (B - D) (d0) FIGRA 0,2MJ [W/s] 92,5 0 (B) THR 600s [MJ] 4,9 4,0 (B) LFS < edge yes Yes (B) SMOGRA [m 2 /s 2 ] 6,4 0 (s1) TSP 600s [m 2 ] 22,1 50 (s1) Burning time of flaming droplets/particles [s] ne (d0) 4. CLASSIFICATION AND FIELD OF APPLICATION 4.1. Reference of classification This classification has been carried out in accordance with the clauses 11.6, 11.9.2 and 11.10.1. of EN 1501-1:2007 4.2. Classification The product, IZOPOLI WALL & COLD STORE PANELS, in relation to its reaction to fire behaviour is classified: B

REACTION TO FIRE CLASSIFICATION REPORT.ERA-09-017 Page 4 The additional classification in relation to smoke production is: The additional classification in relation to flaming droplets / particles is: s1 d0 The format of the reaction to fire classification for IZOPOLI WALL & COLD STORE PANELS is: Fire behaviour Smoke production Flaming droplets B - s 1, d 0 Reaction to fire classification: B-s1, d0 4.. Field of application This classification is valid for the following product parameters: For core material (IPN Foam): For panel: Surface paint coating: For galvanized steel coating: Density: 40 ±6 kg/m minal thickness: 100 to 150 mm Thickness 25 µm Thickness: 0,5 to 1,0 mm The classification is valid for the following end use applications: - Product directly fixed without backing boards with vertical joints and inner/outer corner L profiles. - Black, non-combustible silicone seal SOUDAL was used in the joints for assembly of samples

REACTION TO FIRE CLASSIFICATION REPORT.ERA-09-017 Page 5 5. LIMITATIONS 5.1. Restrictions This classification report is valid until 22 nd of March 2015, provided that the technical specifications of the product will not be changed. 5.2. Warning This classification document does not represent type approval or certification of the product. Signed: Approved:...... Ali BAYRAKTAR Onur DAĞ Laboratory Manager