2 FCP 32/FCH 32 Conventional Automatic Fire Detectors Thermal sensor (temperature sensor) A thermistor in a resistance network is used as a thermal se

Similar documents
Conventional Automatic Detectors FCP-320/FCH-320. Operation Guide

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Smoke detector 500 Series The art of invisible fire detection

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Fire detection equipment

Analogue addressable devices

Auto-iris Motorized Zoom Lenses

Product Guide Specification

G3A Series AutoDome Indoor Systems

MINERVA MX MX Virtual Multi-Sensor Detectors

AlarmSense 2-wire detection and alarm system. Product Guide

D287/D288/D292/D293A/D293E

LBB 442x/xx Power Amplifiers

Premier M Plus & Infinity 8

LBC 14x0/x0 MK Volume Controls and LBC 1430/10 Program Selector

VG4 Fiber Optic Media Converter

Input module, input/output module

MIC-WKT and MIC-WKT-IR

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Smoke exhaust systems

Fire Detection Product Range

Product and Application Description

Product Information Fire alarm panel 8000 C

HERZ-Thermal Actuators

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Digital Pressure Measuring Instrument MDR480

CB Zone Conventional Control Panel

Rosemount 333 HART Tri-Loop

Rosemount 333 HART Tri-Loop

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

W 260: Standard photoelectric switch series for a broad range of applications

LTC 8900 Series Allegiant Matrix/Control Systems - Modular

DLO1191 Linear smoke detector

Accessory Packages for the Allegiant

Cross-beam scanning system to detect slim objects. 100 mm in

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

RM4TG20 three-phase network control relay RM4-T - range V

Fire & Security DETECTORS

FACTORY AUTOMATION EXPERTISE AND SERVICE OPEN DOORS RADAR SENSORS FROM PEPPERL+FUCHS

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

RRV934. Multi-controller. Synco living

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

welcome to our world fire alarm systems - series 600

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

ACS-30-EU-EMDR-10-MOD

Mitel DECT Base Stations

Dräger Alcotest 9510 Evidential Alcohol Measuring Device

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Fire Alarm system Installation Guide

Combi B Alarm box. Mounting instructions

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

UML Series 42- and 55-inch High Performance HD LED Monitors

PIEZOMETER AIRFLOW MEASURING RING

Flameproof Audible Signal 115 db (A) Series YA90

Busch-Watchdog Presence EIB Type:

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

Fire Alarm System Accessories

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

SERIES 65 ENGINEERING PRODUCT GUIDE

TMS TANK MANAGEMENT SYSTEM

PRODUCT PROFILE FEATURES

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

BS5839 Part 1:2002 Overview

Operating Instructions. Room temperature controller

Vacuum drying oven for non-flammable solvents

Divar - Digital Video Recorder

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

FIREDEX Conventional Fire Panels

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Preset Counter signo 721

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

W 36: Mastering complex tasks reliably

Rittal TopTherm fan-and-filter unit

The supplier and installer of the system should be approved by the local civil defence authority.

Vario-Series Accessories

Frequency Converter Fv

Shunt lock function 3066

IS76 Beacon with Ferrite Antenna Installation Manual

Fire alarm system EBL512 G3

intelligent solutions

J TB/TW Temperature limiter, temperature monitor

COOL Shelf Quick Connect

Modular I/O System Analog and Digital Interface Modules

Transcription:

Fire Alarm Systems FCP 32/FCH 32 Conventional Automatic Fire Detectors FCP 32/FCH 32 Conventional Automatic Fire Detectors www.boschsecurity.com High reliability of detection thanks to evaluation electronics Active adjustment of the threshold (drift compensation) if the optical sensor becomes dirty Activation of a remote external detector alarm display possible Mechanical removal lock (can be activated/deactivated) Dust-repellent labyrinth and cap construction The FCP 32/FCH 32 Series Conventional Automatic Fire Detectors set new standards in fire detection technology through a combination of optical, thermal and chemical (gas) sensors and intelligent evaluation electronics. Their most impressive feature is their ability to prevent false alarms, as well as speed and accuracy of detection. The enhanced operating voltage range of 8,5 V DC up to 3 V DC and the two variants with 82 Ω alarm resistor or 47 Ω alarm resistor enables the detector application with nearly all conventional fire panels. System overview Operating mode OC32 OT32 O32 FCH- T32/ T32- FSA Combined x x - - Optical (scattered light measurement) x x x - Thermal max. - x - x Thermal differential - x - x Chemical (gas measurement) Functions x - - - The OC32 and OT32 Multisensor Detectors each combine two detection principles. All sensor signals are analyzed continually by the internal evaluation electronics and are linked with each other. If a signal combination fits the detector's programmed code field, an alarm is automatically triggered. By linking the sensors, the combined detectors can also be used in places where work carried out gives rise to light smoke, steam or dust. Optical sensor (smoke sensor) The optical sensor uses the scattered-light method. An LED transmits light to the measuring chamber, where it is absorbed by the labyrinth structure. In the event of a fire, smoke enters the measuring chamber and the smoke particles scatter the light from the LED. The amount of light hitting the photo diode is converted into a proportional electrical signal.

2 FCP 32/FCH 32 Conventional Automatic Fire Detectors Thermal sensor (temperature sensor) A thermistor in a resistance network is used as a thermal sensor; an analog-digital converter measures the temperature-dependent voltage at regular intervals. When the maximum temperature of 54 C is exceeded (thermal maximum), or if the temperature rises by a defined amount within a specified time (thermal differential), the temperature sensor triggers the alarm status. Chemical sensor (CO gas sensor) The main function of the gas sensor is to detect carbon monoxide (CO) generated as a result of a fire, but it will also detect hydrogen (H) and nitrous monoxide (NO). The sensor signal value is proportional to the concentration of gas. The gas sensor delivers additional information to effectively suppress deceptive values. Depending on the service life of the gas sensor, the OC 31 detector switches off the C sensors after five years of operation. The detector will continue to function as an O detector. The detector should then be exchanged immediately in order to be able to keep using the higher reliability of detection of the OC detector. Special features Drift compensation in optical unit Drift compensation in the gas sensor OC32 Certifications and approvals The detectors comply with: OT32 O32 FCH- T32 / T32-FSA x x x - x - - - EN54 5:2/ A1:22 EN54 7:2/ A1:22 OC32 OC32-R47 OT32 OT32-R47 O32 O32-R47 FCH-T32 T32-R471 FCH-T32-FSA Region Certification Germany G 283 FCH-T32_-R47 G 284 FCH-T32-FSA G 281 O32_-R47 Europe CE /FCH-32 G 282 OT32_-R47 G 285 OC32_-R47 786--2353 FCH-T32_FCH- T32-R47 786--2354 FCH-T32-FSA 786--2351 O32_ O32-R47 786--2355 OC32_ OC32-R47 786--2352 OT32_ OT32-R47 18/1 O32 Installation/configuration notes Up to 32 detectors can be connected per primary line. Maximum cable length: 1 m, for J- Y(St) Y n x 2 x.6/.8 Country-specific standards and guidelines must be observed during the planning phase. The detector can be painted (cap and base) and thereby adapted to the surrounding colour scheme. Note the information in the Painting Instructions (Document Number F.1U.89.231). Installation/configuration notes in accordance with /VDE/DIBt Planning for multisensor detectors follows the guidelines for optical detectors, unless a specific planning guideline is available (see DIN VDE 833 Part 2 and VDS 295). The OC and OT types are planned using the guidelines for optical detectors if operated as optical detectors or as combined detectors; see DIN VDE 833 Part 2 and VDS 295. When planning fire barriers according to DIBt, you have to use the FCH-T32-FSA. This detector has the characteristic curve corresponds to class A1R. Parts included Q t y. Components OC32 1 Multisensor Detector Optical/Chemical OT32 1 Multisensor Detector Optical/Thermal O32 1 Optical Smoke Detector

3 FCP 32/FCH 32 Conventional Automatic Fire Detectors FCH-T32 1 Heat Detector (Thermal Differential/Thermal Maximum) FCH-T32- FSA Technical specifications Electrical Operating voltage Current consumption Alarm output Indicator output Mechanics 1 Heat Detector for Fire Barriers conforming to DIBt, Quality-controlled (Thermal Differential/ Thermal Maximum) 8.5 V DC to 3 V DC <.12 ma Increase in current (alarm resistance 82 Ωor 47 Ω) Open collector connects V in the event of an alarm over 3.92 kω Maximum installation height OC32, OT32, O32 16 m (Heed local guidelines!) 16 m (Heed local guidelines!) FCH-T32 6 m (Heed local guidelines!) Special features Response sensitivity Optical part <.2 db/m, in line with EN 54 T7 Thermal maximum part Thermal rate-of-rise part (in line with pren 54 5) >54 C FCH-T32: A2R FCH-T32-FSA: A1R Chemical part In ppm range Color code Individual display Dimensions LED red OC32 Blue ring OT32 Black ring Without base Ø 99.5 x 52 mm With base Ø 12 x 63.5 mm Housing material Plastic, ABS Housing color White, similar to RAL 91, matt finish Weight Without / with packaging OC32 Approx. 85 g / approx 13 g OT32 / O32 / FCH-T32 / FCH-T32-FSA Environmental conditions Approx. 8 g / approx. 12 g Protection class as per EN 6529 IP 4, IP 43 with detector base with damp room seal Permissible relative humidity Permissible air speed Permissible operating temperature 95% (non-condensing) 2 m/s OC32-1 C to +5 C OT32-2 C to +5 C O32-2 C to +65 C FCH-T32 / T32-FSA -2 C to +5 C Planning Monitoring area OC32, OT32, O32 Max. 12 m 2 (Heed local guidelines!) O32 No marking FCH-T32 / T32-FSA Red ring Ordering information FCP O32 Optical Smoke Detector conventional technology, with 82 Ohm alarm resistor Order number O32 FCP OT32 Multisensor Detector Optical/Thermal conventional technology, with 82 Ohm alarm resistor Order number OT32 FCP OC32 Multisensor Detector Optical/Chemical conventional technology, with 82 Ohm alarm resistor Order number OC32 FCP OC32 R47 Multisensor Detector Optical/Chemical conventional technology, with 47 Ohm alarm resistor Order number OC32-R47 FCP OT32 R47 Multisensor Detector Optical/Thermal conventional technology, with 47 Ohm alarm resistor Order number OT32-R47 FCP O32 R47 Optical Smoke Detector conventional technology, with 47 Ohm alarm resistor Order number O32-R47 FCH T32 Heat Detector conventional technology, thermal differential/thermal maximum detector, with 82 Ohm alarm resistor Order number FCH-T32 FCH-T32 Max. 4 m 2 (Heed local guidelines!)

4 FCP 32/FCH 32 Conventional Automatic Fire Detectors FCH T32 R47 Heat Detector thermal differential/thermal maximum detector, conventional technology, with 47 Ohm alarm resistor Order number FCH-T32-R47 FCH-T32-FSA Heat Detector, for Fire Barriers conforming to DIBt thermal differential/thermal maximum detector, conventional technology, with 82 Ohm alarm resistor Order number FCH-T32-FSA Accessories MS 4 Detector Base Order number MS 4 MS 4 B Detector Base Bosch-branded detector base for surface mounted and flush-mounted cable feed Order number MS 4 B MSC 42 Additional Base with Damp Room Seal for surface-mounted cable feed Order number MSC 42 MH 4 Detector Heating Element usable at locations where the functional safety of the detector might be impaired by condensation Order number MH 4 SK 4 Protective Basket prevents damage Order number SK 4 SSK 4 Protective Dust Cover (packing unit = 1 units) Order number SSK 4 TP4 4 Support Plate for Detector Identification (packing unit = 5 units) Order number TP4 4 TP8 4 Support Plate for Detector Identification (packing unit = 5 units) Order number TP8 4 MSR 32 Conventional Detector Base with Relay with a change-over relay (Form C) Order number MSR 32 MSD 32 Conventional Detector Base with Diode for Great Britain Order number MSD 32 MSS 3 Detector Base Sounder White Control via C-point of the detector Order number MSS 3 MSS 3-WH EC Detector Base Sounder White Control through fire panel via interface Order number MSS3-WH-EC MSR 32 Conventional Detector Base with Relay with a change-over relay (Form C) Order number MSR 32 MPA External Detector Alarm Display according to DIN 14623 the transparent red alarm display conforms to DIN 14623 Order number MPA FAA 42 RI Remote Indicator required if the detector is not directly visible or has been mounted in false ceilings or false floors Order number FAA-42-RI Mounting Bracket for Fire Detectors on False Floor Stilts Order number FMX-DET-MB MK 4 Detector Console Console for DIBt compliant mounting of detectors above doors etc., including detector base Order number MK 4

5 FCP 32/FCH 32 Conventional Automatic Fire Detectors 32/FCH-32 Conventional Automatic Fire Detectors FCP O32 Optical Smoke Detector FCP OC32 Multisensor Detector Optical/Chemical FCP OT32 Multisensor Detector Optical/Thermal optical optical/chemical optical/thermal Operating voltage 8.5 V DC... 33 V DC 8.5 V DC... 33 V DC 8.5 V DC... 33 V DC Current consumption <.12 ma <.12 ma <.12 ma Protection category IP 4, IP 43 with MSF 4 IP 4, IP 43 with MSF 4 IP 4, IP 43 with MSF 4 Permissible operating temperature -2 C... +65 C -1 C... +5 C -2 C... +5 C Monitoring area max. 12 m² max. 12 m² max. 12 m² Maximum installation height 16 m 16 m 16 m Alarm resistance 82 Ω 82 Ω 82 Ω Color code no marking blue loop black loop For fire barriers conforming to DIBt, quality-controlled FCP O32 R47 Optical Smoke Detector FCP OC32 R47 Multisensor Detector Optical/Chemical FCP OT32 R47 Multisensor Detector Optical/Thermal optical optical/chemical optical/thermal Operating voltage 8.5 V DC... 33 V DC 8.5 V DC... 33 V DC 8.5 V DC... 33 V DC Current consumption <.12 ma <.12 ma <.12 ma Protection category IP 4, IP 43 with MSF 4 IP 4, IP 43 with MSF 4 IP 4, IP 43 with MSF 4 Permissible operating temperature -2 C... +65 C -1 C... +5 C -2 C... +5 C Monitoring area max. 12 m² max. 12 m² max. 12 m² Maximum installation height 16 m 16 m 16 m Alarm resistance 47 Ω 47 Ω 47 Ω Color code no marking blue loop black loop For fire barriers conforming to DIBt, quality-controlled

6 FCP 32/FCH 32 Conventional Automatic Fire Detectors FCH T32 Heat Detector FCH T32 R47 Heat Detector FCH-T32-FSA Heat Detector, for Fire Barriers conforming to DIBt thermal differential/thermal maximum thermal differential/thermal maximum thermal differential/thermal maximum Operating voltage 8.5 V DC... 33 V DC 8.5 V DC... 33 V DC 8.5 V DC... 33 V DC Current consumption <.12 ma <.12 ma <.12 ma Protection category IP 4, IP 43 with MSF 4 IP 4, IP 43 with MSF 4 IP 4, IP 43 with MSF 4 Permissible operating temperature -2 C... +5 C -2 C... +5 C -2 C... +5 C Monitoring area max. 4 m² max. 4 m² max. 4 m² Maximum installation height 6 m 6 m 6 m Alarm resistance 82 Ω 47 Ω 82 Ω Color code red loop red loop red loop For fire barriers conforming to DIBt, quality-controlled Represented by: Americas: Europe, Middle East, Africa: Asia-Pacific: China: America Latina: Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Bosch (Shanghai) Security Systems Ltd. Robert Bosch Ltda Security Systems Division 13 Perinton Parkway Fairport, New York, 1445, USA Phone: +1 8 289 96 Fax: +1 585 223 918 security.sales@us.bosch.com www.boschsecurity.us P.O. Box 82 5617 BA Eindhoven, The Netherlands Phone: + 31 4 2577 284 Fax: +31 4 2577 33 emea.securitysystems@bosch.com www.boschsecurity.com Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 288 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia 21 Building, No. 333 Fuquan Road North IBP Changning District, Shanghai 2335 China Phone +86 21 22181111 Fax: +86 21 22182398 www.boschsecurity.com.cn Via Anhanguera, Km 98 CEP 1365-9 Campinas, Sao Paulo, Brazil Phone: +55 19 213 286 Fax: +55 19 213 2862 al.securitysystems@bosch.com www.boschsecurity.com Bosch Security Systems 212 Data subject to change without notice 1265936267 en, V4, 26. Nov 212