Installation & Operating Instructions

Similar documents
OPERATING INSTRUCTIONS

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Fused Spur Time Switch

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Drayton Digistat +2RF/+3RF

Wireless 7 Day Programmable Room Thermostat

Quantec Wiring Instructions

INFRARED QUARTZ WALL HEATER

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

Model 201 Wiegand Touchpad Reader Installation Guide

5W LED Energy Saver PIR Bulkhead

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

60W PIR BULKHEAD LIGHT SLB88-Black/SLW89-White INSTALLATION & OPERATING INSTRUCTIONS

FIREDEX Conventional Fire Panels

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

Section B: Electricity

AC-115 Compact Networked Single Door Controller. Installation and User Manual

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Manual for Fire Suppression & Methane Detection System

HM-W536 Install Guide

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

Emergency voice communications Product Name

Fire. The Fire Installers Mate. A guide to fire alarm systems design

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

12 Volt 30 Amp Digital Solar Charge Controller

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

Digital Keypad Use s Manual

TS510 & TS500. Installation & User Guide. Compatible Equipment

How To Use A Power Supply Unit (Upu)

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

Single Channel Loop Detector

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Advantium 2 Plus Alarm

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

GST301. (Single Protection Zone) Operation Manual

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

WIRELESS HOME ALARM SYSTEM (WHA1)

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Operating Instructions

Contractors Guide Central Inverter System Installation

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

LOXONE 12 Channel Amplifier

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Installation Guide for Hive Active Heating

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

CB200W Water Leak Detection Panel Application Guide

User Manual Color video door phone

Electrical Practices for Construction Work

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains


ADDING AN ELECTRIC AUXILIARY FAN TO RADIATOR STACK ON 03 ALPINE COACH

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Xenon HID Lighting System

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

System Tel (Telephones) Ltd Fax Web

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

MIC-WKT and MIC-WKT-IR

INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Please also see 10 golden rules for correct Saniflo installation on

Residential Gateway (RG) Battery Backup

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HMI display Installation Guide

Shunt lock function 3066

Nest Learning Thermostat Installation Guide. Installation step-by-step

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

SAVE THIS MANUAL FOR FUTURE REFERENCE

Installation Handbook. Interactive Fire Alarm System Release 3. Repeater Panel BU-320 / Information Panel BV-320

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Manual Ranging MultiMeter

EWR2 WIRELESS SIGNAL REPEATER

Fire Alarm Control Panel. Family. Operating Manual

3M Wrist Strap and Footwear Tester 740. User s Guide

WIRELESS STATUS MONITOR

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

Remote Alarm Monitoring System

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

16/32 Channel 1U Rack Mount CCTV Power Supply

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

HP UPS R1500 Generation 3

AudioJoG (TM) Pro 8 Connector PIN LABEL LED Connector PIN LABEL LED. Operations Manual 3.5mm & 6.35mm Mono/Stereo Jacks

conventional system operation

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Transcription:

Emergency assist alarm Models covered: Single Zone Plastic Control Unit Single Zone Stainless Steel Control Unit Plastic Reset Unit Stainless Steel Reset Unit Plastic Over-Door Unit Stainless Steel Over-Door Unit Pull Cord Unit Four Zone Plastic Control Unit Four Zone Stainless Steel Control Unit Single Zone Plastic System Kit Single Zone Stainless Steel System Kit Installation & Operating Instructions

1 1. Models Covered Components Single Zone Plastic Control Unit EACP1 (with battery back up EACP1PR) Single Zone Stainless Steel Control Unit EASSCP1 (with battery back up EASSCP1PR) Plastic Reset Unit EARB1 Stainless Steel Reset Unit EASSRB1 Plastic Over-Door Unit EADF1 Stainless Steel Over-Door Unit EASSDF1 Pull Cord Unit EAPC1 Four Zone Plastic Control Unit EACP4 (with battery back up EACP4PR) Four Zone Stainless Steel Control Unit EASSCP4 (with battery back up EASSCP4PR) Kits Single Zone Plastic System Kit EASZK (with battery back up EASZPRK) Single Zone Stainless Steel System Kit EASSSZK (with battery back up EASSSZPRK) Both of which comprise of components from the above list

Typical Single Zone System (Available as EASZK) Fused Spur (not supplied) Single Zone Control Unit 2-wire 2 Pull Cord Unit 2-wire Over Door Unit 2-wire Reset Unit

Typical Four Zone System There are no four zone kits, but two to four zones can be accommodated by using any of the four zone Control Units in combination with the appropriate number of Reset Units, Over-Door Units and Pull Cord Units. There are no adverse effects if any of the four zone control units input connections are left open. 2-wire Four Zone Control Unit 3 2-wire Pull Cord Unit 2-wire Over Door Unit Reset Unit

4 2. Introduction The basic system consists of a Control Unit (which is powered by AC mains supply) connected by an extra low voltage 2- wire link to a Pull Cord Unit which is in turn connected to an Over-Door Unit by another extra low voltage 2-wire link. The Over-Door Unit is then connected to a Reset Unit by a further extra low voltage 2-wire link. When the pull cord, mounted adjacent to the W.C., is pulled, the red L.E.D. on the Pull Cord Unit is activated until the system is reset, assuring the disabled person in distress that the system has been activated. The sounder and the light on the Over-Door Unit outside the cubicle, are activated intermittently. At the Reset Unit inside the cubicle, the light and sounder are activated intermittently and will both be further reassuring the person in distress. At the Control Unit the alarm light and the sounder are activated continuously. Either the Over-Door Unit or the Control Unit will attract the attention of an appropriate person either directly or indirectly and that person will note the zone in alarm, press the reset button at the Control Unit clearing the alarm and then investigate the toilet cubicle in question. Note: Reset button at the Control Unit can be disabled by moving the reset selection switch to the OFF position. At any time if the difficulty is resolved the person in distress can clear the alarm by pressing the reset button in the cubicle. 3. Installation Important: This system must be installed and maintained by a suitably qualified person. Connect the Extra Low Voltage wiring first. Connect Mains wiring last. See mains ratings in diagram. Mains supply must come from a fused spur and

MUST be switched off at all times while installation is in progress The installation shall be carried out in accordance with all applicable installation rules. None of the units in the system should be subject to dripping or splashing liquids. When using the Control Unit with a 25mm deep box choose the fixing holes to ensure clearance between the screw heads and the rear of the control unit. Wiring and Fixing Holes Final page gives expanded view of this diagram. Reset Selection Battery Holder (Back-up PR versions only) Connector for incoming mains supply Mains rating information 5 Warning Do not connect to mains supply! External Alarm Buzzer Fixing Holes Output Control Unit (Rear) Transformer Fixing Holes Pull Cord Hole Cover Fixing Holes Pull Cord Unit (Backplate) Fixing Holes Fixing Holes Over-Door Unit (Rear) Reset Unit (Rear)

3.1. Control Unit This should be sited (following the recommendations of BS8300) where it can best attract the attention of an appropriate person/member of staff. An example of this is near a reception desk in view of a receptionist. Having located the site, install a flush or surface mount double gang wall box at least 25mm deep. Bring the mains supply cable (1mm 2 twin and earth) into the box and connect to the terminals on the Control Unit marked L and N (see diagram). Connect the incoming wiring as instructed below. 6 Mains Wiring Important: All mains wiring should be provided in accordance with the relevant national wiring rules Bring the mains supply cable (1mm 2 TFE) into the box and connect the Live and Neutral wires to the terminals on the Control Unit marked L and N respectively.(see diagram) Ensure the lengths of wires inside the connectors are prepared correctly. Connection should be made firmly after all strands are entered into the terminals.). Connect the incoming earth wire as instructed below NOTE: This is a class 1 apparatus if a metal box is used and therefore the earth wire MUST be connected to the earth terminal of the metal box itself. If a plastic box is used, connect the earth wire to the Earth connector marked on the Control board. On the stainless steel version, connect the earth wire to the Earth connector on the Control board. The metal box will be earthed via the stainless steel screws provided.

7 Extra Low Voltage Wiring Important: Ensure that low voltage wiring are kept well away from mains wiring. The low voltage wiring must be tied to each other using the tie wrap provided to overcome clearances and creepage distances if any wire becomes detached. Bring the extra low voltage two core cable into the wall box and connect to the terminals marked output (see diagram). The system is not polarity conscious. Fix the Control Unit to the wall box using the screws provided. Insert battery into battery holder Connections are as above diagram for a single zone system. The four zone system is similar except that the four zone Control Unit has 4 outputs, each one being used will have a Pull Cord Unit, an Over-Door Unit and a Reset Unit connected in the same way as the single zone system. Any unused outputs should be left unconnected. The interconnections should be made with two core cable of at least 7/0.2mm copper conductors (bell flex is suitable). Finally, if reset capability is not required at the Control Unit, move the reset selection switch to the OFF position.

8 3.2. Pull Cord Unit BS8300 (code of practice for the design of buildings and their approaches to meet the needs of disabled people) recommends that this should be sited on the ceiling such that for a toilet it can be operated from the W.C. and an adjacent floor area. The lower handle should be set 100mm above the floor (knot and trim off any excess cord) and the upper handle should be set between 800 and 1000mm above the floor (knot the cord at required height). Hold the unit backplate in position on the ceiling and mark through the fixing holes on the unit backplate and drill and plug (if necessary) holes suitable for four No 6 screws. Bring the extra low voltage two core cable from the Control Unit through the backplate and connect to the terminals marked input (see diagram). Bring a further extra low voltage two core cable through the backplate and connect to the terminals marked output. Fit the cover to the backplate and fix with the two screws provided. Attach the two handles to the pull cord as described at the beginning of this section.

9 3.3. Over-Door Unit This should be sited to attract appropriate personnel to the area where assistance is required. An example of this is above the toilet cubicle door. Having located the site, install a flush or surface mount single gang wall box at least 25mm deep. Bring the extra low voltage two core cable from the Pull Cord Unit into the wall box and connect to the terminals marked input (see diagram). Bring a further extra low voltage two core cable into the wall box and connect to the terminals marked output. Fix the Over-Door Unit to the wall box using the screws provided. Fix the W.C sticker to the cubicle door. 3.4. Reset Unit BS8300 recommends that this should be sited on a wall such that for a toilet it can be reached from the W.C. and a wheelchair. The recommended height is between 750 and 1200mm above the floor and horizontally it must not be mounted closer than 350mm to any corner. Having located the site, install a flush or surface mount single gang wall box at least 25mm deep. Bring the extra low voltage two core cable from the Over-Door Unit into the wall box and connect it to the terminals marked input (see diagram). Fix the Reset Unit to the wall box using the screws provided.

4. Battery A battery is provided with the following control units and kits - EACP1PR, EASSCP1PR, EACP4PR or EASSCP4PR and cannot be fitted to other types. To fit the battery remove it from the holder and turn it round and offer it up to the connector and after correct polarity is ensured press the battery into the connector. The battery takes 48 hours to get to full charge from when first connected to the control unit and mains voltage applied to the L and N terminals. An illustration of full reserve capability is as follows: 10 Single zone system Four zone system Typically 4 days on standby with 2 hours continuous alarm. 1 day on standby with 30 minutes continuous alarm (1 zone only). Battery Disposal When battery has reached end of useful life insulate terminals and consult your local authority about disposal. Do not dispose of in fire. Caution. Danger of explosion if battery is incorrectly connected. Replace only with same type of NIMH rechargeable battery. Important. Ensure battery is inserted with correct polarity. Do not force battery onto contacts.

5. Commissioning Switch on the mains supply to the Control Unit and check the left hand Supply On indicator (green) is illuminated. The Fault (yellow) and Alarm (blue) indicators should be off. If the Fault indicator is illuminated this almost certainly indicates that there is an open or short circuit in the extra low voltage wiring. Assuming the Fault indicator is off pull the pull cord and the system should behave as described in the second paragraph of section 2. Having observed this to be the case press the Reset button on the Control Unit to end the alarm. Pull the pull cord again and verify each unit is performing correctly then press the Reset button on the Reset Unit to end the alarm. 11 6. Diagnostics Warning : Switch off mains supply before removing the front cover or dismantling the control unit. Remove all power source including battery when wiring any part of the system. The following possible faults and solutions are for guidelines only. If in doubt contact the Timeguard Helpline on 020 8450 0515

12 Symptoms Possible fault Possible Solution Green LED on Control Unit is OFF Yellow LED on Control Unit is ON Blue LED on Control Unit is continuously ON and cannot be reset Alarm cannot be reset from Control Unit Pull Cord does not initiate an alarm Mains supply not connected Mains switch is off Some units in the system are not properly connected Battery is not fully charged 2 wire link is shorting Battery is too low Reset selector in the OFF position Pull Cord unit is not connected Cord is not properly inserted Check Mains wiring Switch on mains supply Checks the 2 wire link in all units are properly secured in the connectors. If system is running on backup battery, check that the battery is fully charged Check there is no short circuit in any unit Check the 2 wires are not touching Switch on mains supply to charge battery Move Reset selector to the ON position Check connections to the Pull Cord unit See description above

13 7. Specifications Control Unit Supply voltage: 230V (+10%, -15%) 50Hz Operating temperature: +5 to 40 C Reserve battery: Metal Hydride (rechargeable) PP3, 9Volt Alarm Output: DC voltage through 470 ohm resistor. (Do not connect to mains voltage source) Maximum pull force on pull cord: 200N Reset button marking: Visually and with Braille Intensity of sounders: Control Unit and Reset Units 65dB at 30 cm Over-Door Unit 78dB at 30 cm Sound and light are intermittent except Control Unit Angular coverage of indicator: 180 on Over-Door Unit: EC directives: Conforms to 73/23/EEC and 89/336/EEC Dimensions: plastic (stainless steel) Control Unit 145 x 85 x 33, (145 x 85 x 35) mm Pull cord Unit 82 diameter x 20 mm Overdoor Unit 85 x 85 x 24, (85 x 85 x 25) mm Reset Unit 85 x 85 x 12, (85 x 85 x 13) mm 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515.

Installation Wiring and Fixing Holes Reset Selection Battery Holder (Back-up PR versions only) Mains rating information Connector for incoming mains supply Warning Do not connect to mains supply! External Alarm Buzzer Output Fixing Holes Control Unit (Rear) Transformer 14 Fixing Holes Pull Cord Hole Cover Fixing Holes Pull Cord Unit (Backplate) Fixing Holes Fixing Holes Over-Door Unit (Rear) Reset Unit (Rear)

Helpline 020-8450-0515 For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND 020-8452-1112 or email csc@timeguard.com 67.058.192 Iss 1