Tailored Application Solutions



Similar documents
How To Run A Valley Field Tractor

CENTER PIVOT IRRIGATION

water application solutions

Produced by Agricultural Communications, The Texas A&M University System Extension publications can be found on the Web at:

Chemigation Calibration for Center Pivot Irrigation Systems

cams Management Systems Technology focused on conserving energy Performance. Period.

Irrigation Efficiency Rewards

Lecture 12 Center Pivot Design & Operation. I. Introduction and General Comments

DEFINITIONS Water Conveyance Efficiency (E c. ): The percentage of source water that reaches the field. E c. = 100 (W f. / W s.

1. Sprinkler selection 2. Design of the system layout 3. Design of the laterals 4. Design of the mainline 5. Pump and power unit selection

Greenhouse Sprinkler Systems

United States Department of Agriculture. Natural Resources Conservation Service

Valley. Controls RELIABLE DURABLE PRECISE ADVANCED RESPONSIVE

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

2005 WJTA American Waterjet Conference August 21-23, 2005 Houston, Texas Paper SAFE WATERJET CLEANING OF STEEL PROCESS LINES

Selection and Management of Efficient Low Volume Irrigation System

Small-Scale Irrigation Options

Technical Service Bulletin

Free Stall Cleaner System with Cable. A new generation of equipment and systems. GEA Farm Equipment Houle

Hose Clamps & Fittings

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.

Valu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.

System 9000 BEREGNUNGSSYSTEME

Redefining Spray Technology

Irrigation can increase the production of

Application Data Important Safety Information

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

Spouts and Flow Regulators

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Cost-effective solutions for all applications.

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Optimizing Tank Cleaning Operations

Firefighter Review. Instructor Guide

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

Lecture No Active summer cooling systems Fan-and Pad cooling system Fog cooling system

How to Pre-empt a Significant Profit Drain: Nozzle Wear

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

EIN DOR EMITTERS. Sprinklers and Sprayers

Hose and Tube Fittings Series 1-3

SPRINKLER IRRIGATION:

Wildland Fire Remote Monitor

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

SAFETY SAFETY APPAREL 20,000 PSI

Nebraska Department of Roads Drainage and Erosion Control Manual December 2011 Appendix C: Pipe Material Policy Page C-1 PIPE MATERIAL POLICY

The conditions below apply to the curves shown on the following pages.

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

GROW MORE WITH LESS MEGANET SPRINKLERS

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

30 minutes in class, 2 hours to make the first time

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

INSTALLATION. General. Important Note. Design. Transport

WAVELET WATER QUALITY MONITORING KIT

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

IRRIGATION FOR PEACHES Irrigation Systems for Peaches

ELECTRIC PERISTALTIC MORTAR POINTING PUMP


SPEEDROC D30. Surface Drill Rig for marble, granite, sandstone and limestone in the dimension stone industry.

EUPEN Cable Inc. North & South America

Flow Measurement Options for Pipeline and Open Channel Flow

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

Water Saving Technology

Operators manual Basic water heater

Manual piston sampler...m 11

5000 Series Rotors 5000, Plus, PRS, SAM

AIR LINE VALVES AND GAUGES

Product catalogue, pipe and sewer cleaning systems

Industrial Monitors. Weight lbs. (Kg) Style. 55* (24.9 kg) 14"** (356 mm) * Less nozzle ** Less handle. Weight lbs. (kg) Style / 16"** (538 mm)

Fiberstars Mini Lighted Laminar Flow Fountains

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

exactly what is needed

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

4" SUBMERSIBLE PUMPS

Offering more. Series

DECONTAMINATION PRODUCTS

FULL COVERAGE IRRIGATION for tree & vine crops the facts.

WANJET. Sprayers. Wanjet sprayers has been produced since 1978.

Effect of Temperature

BULLOCK CART LOADED SPV WATER PUMPING SYSTEM FOR SMALL FARMERS

Clinical Solutions.

Ponds- Planning, Design, Construction

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

400B SERIES DIAPHRAGM PUMP

DISC HARROWS IN X-ARRANGEMENT FOR TRACTORS FROM 90 TO 300 HP

Many Products...One Source

Potted Plant Watering Systems

FOR ANY QUESTIONS, PLEASE CALL M-F 8:00a.m.-8:00p.m. EST. REAR BRAKES 1 AEROSPACE COMPONENTS

Stainless Steel Single and Dual Circulation Kits

SWIMMING POOL HEAT PUMP

Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION

Pipe Cutting and Beveling Clamshells

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Drive shaft, servicing

Performance assessment, monitoring and evaluation of a portable sprinkler irrigation system at CSIR-Crops Research Institute

1.1 DIMENSIONS AND WEIGHT PAG LOAD CENTRE FOR LIFTING PAG STORAGE CONDITIONS PAG. 2

The Symbol of Excellence. Hydraulic Dumpers

Transcription:

Tailored Application Solutions Performance. Period. A Step-By-Step Guide

What are Your Needs? Step 1: Determine Your Application Needs Deciding on the correct water application solution is vital to your pivot s, or linear s, performance. First, determine your needs with this step-by-step guide and choose the best solution for your field. Tailored application packages offer you water management, fertilizer application and/or pesticide control. Selecting the right application package can reduce your energy costs and save water. Your options are practically limitless, but the results are the same: providing you the best water application solutions to increase your productivity and profitability.

Selecting an Application System When you re selecting an application system, there are several things to think about. First, what kind? The choices are a fixed pad, a rotating pad, impact sprinklers or LEPA. Each has its distinct set of uses and advantages. If you decide to use a system with pads, then you need to choose the style of pad, which affects the flow of water onto the field. Your choices involve the shape of the pad, the kind of grooves it contains and the depth of the grooves. You ll also decide just where the water s coming from. It can come from the top of the pipe, the top of the crop canopy, down in the canopy or right on the ground. How important are the following to meeting your needs? Rank Impact of Selection Importance Water to You Type Pad Position Conservation Drift Infiltration Fertigation Placement Uniformity Chemigation Herbicide Insecticide Fungicide Chemigation/ Fertigation Equipment enables you to apply agricultural crop protection products and fertilizer uniformly and efficiently, above or below the crop canopy. You save on labor, application costs and up to 25% on some products. Other Energy Cost Crop Cooling Soil Amendments

The Right Package Step 2: Select Application Package Fixed Pad Simple in design, yet offers precision water delivery. Choose from various groove designs to offer you the best water droplet characteristic for your field. Efficient er cost Targeted water placement Senninger LDN Valley -Energy Nozzles (LEN) Nelson D3000 cost water and energy saver Wide variety of available pads Flip-over dual spray cap -high application rate 6-40 psi (,4-2,8 bars) 24-36' (7,3-11 m) wetted diameter Unique shape for movement through crop Only pivot company with exclusive sprinklers 6-40 psi (,4-2,8 bars) 24-36' (7,3-11 m) wetted diameter Crop-guarded body for low energy, in canopy application 6-40 psi (,4-2,8 bars) 28-40' (8,5-12,2 m) wetted diameter Energy Precision Application (LEPA) A complete water management system with low-energy requirements that eliminates drift and offers advanced placement with its drop-tube design. No drift No water on foliage Sock Senninger Quad Spray Minimize erosion to furrow blocks Least cost 6-15 psi (,4-1,0 bar) Very high application rate Two bubble modes eliminate misting and reduce soil redistribution 6-15 psi (,4-1,0 bar)

Rotating Pad Offers better infiltration with a wider wetted diameter (40') and larger drops, reducing drift and evaporation. Better infiltration Less drift Nelson Rotators Nelson Spinners Nelson Accelerator Senninger I-Wob 4, 6, or 8 stream pads available flow capacity Improved water penetration Gentle application -medium application rate uniformity in-canopy -medium application rate 15-50 psi (1,0-3,4 bars) 10-20 psi (,7-1,4 bars) 10-15 psi (0.7-1.0 bars) 10-20 psi (,7-1,4 bars) 50-60' (15,2-18,3 m) wetted diameter 45-55' (13,7-16,8 m) wetted diameter 25-40 (7,6-12,2 m) wetted diamter 50-55' (15,2-16,8 m) wetted diameter Impact Delivers the best soil infiltration through the largest wetted diameter. Best Infiltration Saves water formerly lost to wind drift angle, low angle or part circle Nelson Senninger angle Sturdy brass drive arm 25-60 psi (1,7-4,1 bars) 100' (30,5 m) wetted diameter 6º trajectory fights wind drift and evaporation Plastic body 25-60 psi (1,7-4,1 bars) 70-95' (21,3-29,0 m) wetted diameter Part Circle Sprinklers 180º spray pattern keeps wheels dry for better traction and minimized wheel tracks. Dry wheel tracks Several options available to help reduce wheel track depths Nelson Part Circle Spinner Rotator uniformity 10-30 psi (0,7-2,0 bars) 20-40' (6,1-12,2 m) wetted radius Senninger LDN Part Circle Spray Concave groove 6-40 psi (,4-2,7 bars) 15-30' (4,6-9,1 m) wetted diameter Nelson Part Circle Spray Concave medium groove 6-40 psi (,4-2,7 bars) 15-30' (4,6-9,1 m) wetted radius

Step 3: Choose Your Application Position Drops Minimizes water drift and evaporation Hose Seven year proven track record Non-corrosive-can be installed with PVC U-pipe Flexible-designed to be drug through crop Reduces spray and drift losses caused by wind, low humidity and high temperatures Can be installed when building span Utilizes 3/4 reinforced hose Galvanized Available for truss rod height (8.5 ) applications PVC Rigid drop works well with rotators, spinners and spray nozzles Utilizes schedule 40, 3/4 galvanized steel Non-corrosive Semi-rigid drops work well with rotators, spinners and spray nozzles Multiple lengths available down to ground clearance (5.5 ) Utilizes schedule 80, 3/4 sunlight resistant material with stainless steel insert in thread area Polyethylene Corrosion resistant Semi rigid, to hang straight but will flex Boombacks Discharge water behind drive unit Utilized with part circle sprinklers to help keep wheel track dry Utilizes 6 (152,4 mm), 6 5/8 (168,3 mm), 8 (203,2 mm), 8 5/8 (219,1 mm) and 10 (254,0 mm) pipe clamps and 3/4 steel tubing for support Remote Drains Minimize wheel tracks in the field with standard drains placed off to the side or through one of the drop tubes for the sprinkler package

Step 4: Select Spacing Step 5: Pressure Regulator Ensure uniform water application, even on hilly or rolling terrain. A properly selected pressure regulator at the base of each sprinkler or spray nozzle will provide a constant flow rate over wide variations in elevation. If there is a variation of 10% or more due to field elevation, pressure regulators are recommended. Valley All Range Regulators 0.5 to 15 gpm (,03,95 lps) capability Available in 6 to 30 psi (0,4 2,0 bar) outlet pressures Valley offers the proper regulator application to meet your requirements Step 6: End Gun Komet SR101 Komet Twin Max Nelson SR100 Nelson SR75 85 Rainbird 65 Rainbird Step 7: Booster Pump Boost end gun pressure on low-pressure machines to improve end gun performance. 2 HP 28 psi (1,9 bars) booster on end gun flows up to 130 gpm (8,2 lps) 5 HP 35 psi (2,4 bars) booster on end gun flows up to 175 gpm (11,0 lps) 7.5 HP 52 psi (3,5 bars) booster on end gun flows up to 230 gpm (14,5 lps)

Create Your Water Application System Step 1: Determine your application needs Step 2: Select application package Step 3: Choose your application position and select drop Step 4: Select spacing Step 5: Pressure Regulators: Yes or No Step 6: End Guns: Yes or No If yes, then make a selection: Step 7: Booster Pumps: Yes or No If yes, then make a selection: See your local authorized Valley Dealer: 7002 North 288th Street Valley, Nebraska 68064-0358 USA Phone: 402-359-2201 (Ext. 3415) Fax: 402-359-4429 E-mail: irrigation@valmont.com International Fax: 402-359-4948 E-mail: vintl@valmont.com www.valmont.com/irrigation/ Valmont Irrigation has a policy of continuous product improvement and development. As a result, certain changes in standard equipment, options, price, etc., may have occurred after the publication of this catalog. Some photographs and specifications may not be identical to current production. Your local Valley dealer is your best source for up-to-date information. Valmont Irrigation reserves the right to change product design and specification at any time without incurring obligations. 2005 Valmont Industries, Inc., Valley, NE 68064 USA. All rights reserved. AD10185 JN 04/05