Ventilation Strategies: International Best Practice

Similar documents
Fire Development and Fire Behavior Indicators

Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases

Fire and Rescue Service Operational Guidance. GRA 5.8 flashover, backdraught and fire gas ignitions

Firefighter Review. Instructor Guide

GENERIC RISK ASSESSMENT 3.6 FIGHTING FIRES - USING POSITIVE PRESSURE VENTILATION

December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?

SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404

NEW SCIENCE FIRE SAFETY ARTICLE INNOVATING FIRE ATTACK TACTICS SUMMER 2013 UL.COM/NEWSCIENCE

Flashover. Newsletter by Vincent Dunn-July 2000

Improving fire safety through engineering (rational designs)

Natural Gas Emergencies

Gas-Fired, Residential Storage Type Water Heaters

Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

A Guide to the European Standard for Safety Storage Cabinets (BS EN )

Fire-Rated Glass and Glazing START

NFPA Fire Fighter II

Decree of the Ministry of the Environment. on fire safety of garages

Australian/New Zealand Standard

Fume Hood Questions and Answers

FIRE RISK ASSESSMENT

Chemical Fume Hoods. Environmental Health and Safety

CBD-233. Fire Alarm and Detection Systems

exit routes and fire protection

Fire Ventilation. Stefan Svensson

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Fire Ground Leader Guide to Certification. FIRE CERTIFICATION PROGRAM, DPSST 4190 Aumsville Hwy. SE Phone Fax

Spray Booth Guideline

Bastille Court 2 Paris Garden London SE1 8ND Telephone: Fax: training@thefpa.co.uk Web:

Work Permits. A Health and Safety Guideline for Your Workplace. When is a Work Permit Needed? What is a Work Permit? Why use a Work Permit?

FIRE RISK ASSESSMENT

Piotr Tofiło a,*, Marek Konecki b, Jerzy Gałaj c, Waldemar Jaskółowski d, Norbert Tuśnio e, Marcin Cisek f

Chemical Reactions Practice Test

Fire Safety Risk Assessment Checklist for Residential Care Premises

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

Fire Resistance and Safety in Case of Fire

Nitrogen Blanketing for Methanol Storage and Transportation

HAZARD CONTROL TECHNOLOGIES, INC. Coal Silo-Bunker Firefighting Procedures

On-Line Fire Extinguisher Training

ON MOST schemes, the architectural design of. Flexible strategy. Case study. The Forum

Fire Risk Assessment For Simple Premises

Influence of fire source locations on the actuation of wet-type sprinklers in an office fire

Safety Storage Cabinets

Fire Response Plan - Code Red

Standardized Terminology for Combustion Appliances and. Combustion Safety Testing

FLA S FIRE SAFETY INITIATIVE

English Victorian Semi-Detached House Fire.

Center for Energy Education Laboratory

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

LASER CUTTING OF STAINLESS STEEL

Process Safety Management of Highly Hazardous & Explosive Chemicals. Safe Work Practices

The soot and scale problems

Preventing Ice Dams on Roofs

LESSON PLAN 1. Fire Science. Key Terms and Concepts. ash chemical reaction combustion Consumer Product Safety Commission endothermic exothermic

FIRE-RESISTANT GLAZING Mr Leslie O May Sales Consultant Wright Style Limited England

Accurate Air Flow Measurement in Electronics Cooling

G SPECIFICATION: GAS METER AND REGULATOR INSTALLATION REQUIREMENTS. 3 and Gas Yellow Book. REVISIONS: (See ) 1/15/14 5 Years

EMERGENCY RESPONSE TEAMS AND INCIDENT MANAGEMENT SYSTEMS

PROBATIONARY FIREFIGHTER HANDBOOK

FIRE PREVENTION PLAN

Class A - Wood, paper, cloth, trash, plastics Solid combustible materials that are not metals. (Class A fires generally leave an Ash.

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

HVAC Code Requirements

FIRE EXTINGUISHER TRAINING

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

INTERNATIONAL FIRE PROTECTION

Boiler Preparation, Start-Up and Shutdown

FSD Circular Letter No. 7/95 Automatic Fire Detection System - Design and Maintenance Considerations

Amendment: Combustion Appliance Testing Standards Removal. Proponent: Brett Dillon, Chair Standards Development Committee

INITIAL ASSESSMENT OF THE IMPACT OF JET FLAME HAZARD FROM HYDROGEN CARS IN ROAD TUNNELS AND THE IMPLICATION ON HYDROGEN CAR DESIGN

Presented by: Rich Perry Marsh Risk Consulting

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

Thermodynamics. Thermodynamics 1

An inventory of hazardous materials used in your workplace will prove useful.

The Current Knowledge & Training Regarding Backdraft, Flashover, and Other Rapid Fire Progression Phenomena

NY Fire Safety Institute

FLAMMABLE AND COMBUSTIBLE LIQUIDS

Condensing Boiler Efficiency

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

FIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

A Plan Outline for Neonatal Intensive Care Unit Evacuation Institution. Draft 1

I. Basic Smoke Control Strategy and Tactics

CFD Computational Fluid Dynamics

RESPONSE TIME INDEX OF SPRINKLERS

TEACHER BACKGROUND INFORMATION THERMAL ENERGY

The Importance of Safe Isolation of Plant and Equipment

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

Sounding the Call Carbon Monoxide What You Need to Know

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

The risk assessment of fire damper installations

9/15/2011. Presented by: Jason Reason, CIH, CSP, CHMM Senior Industrial Hygienist Indiana Occupational Safety and Health Administration

MSC/Circ June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

Fire Risk Assessment Safety Checklist

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM ENGINE COMPANY SKILLS 1 ¾ RESIDENTIAL ATTACK LINES

Description of Thermal Oxidizers

HOT WORK PERMIT PROCEDURES

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

Transcription:

Ventilation Strategies: International Best Practice Ed Hartin, MS, EFO, MIFireE, CFO Introduction The chemistry and physics of fire remains consistent throughout the world. However, there is considerable diversity in the strategies and tactics used by firefighters. From the remotest periods of antiquity to the present time, the business of extinguishing fires has attracted a certain amount of attention; but is a most curious fact that, even now, there is so little method in it in that it is a very rare circumstance to find any two countries, or even any to cities in one country, adopting the same means, or calling their appliances by the same name (Shaw, 1876) For as long as humankind has known about fire, its control has been a topic of study. But for all we know about fire there is much more to learn. Ventilation is a key factor in both fire development and control and yet there continues to be considerable misunderstanding and misapplication of ventilation strategies and tactics. Vertical ventilation (see Figure 1), positive pressure ventilation, and anti-ventilation tactics are often embraced or rejected without any scientific evidence or operational experience. Figure 1. Vertical Ventilation Control of ventilation has been used as a firefighting strategy for many years, but has evolved along two paths. One approach is to exclude air to limit the oxygen required for combustion. The men of the fire brigade were taught to prevent, as much as possible, the access of air to the burning materials. What the open door of the ash-pit is to the furnace of a steamboiler the open street door is to the house on fire. In both cases the door gives vital air to the flames (Braidwood, 1830) On the first discovery of fire, it is of the utmost consequence to shut, and keep shut all doors, windows, or other openings. It may often be observed, after a house has been on CFBT-US, LLC Page 1

fire, that one floor is comparatively untouched, while those above and below are nearly burned out, this arrises from a door on that particular floor having been shut, and the draught directed elsewhere (Braidwood, 1866) However, another approach is to remove hot and toxic smoke and fire gases from the building. One of the major reasons that fires get out of control is the lack of proper and adequate ventilation If you want to move in on a smoky fire, you must ventilate or your will be driven out. Yes, you can and should use masks to hold difficult positions. But most jobs [fires] will be readily controlled by good, fast ventilation and a crew determined to move in (Fried, 1972) While the examples used to illustrate the two basic ventilation strategies were drawn from the 19 th and 20 th centuries and are to some extent reflective of the times, these concepts remain just as valid today. International Differences As Shaw (1876) observed, it is rare for two fire departments, much less two nations to follow exactly the same firefighting practices. However, application of ventilation strategies and other firefighting practices has evolved quite differently in the United States in comparison to Europe and Australia 1. The philosophical approach to ventilation strategies in the United States may best be represented by the common fire service maxim vent early and often. Ventilation to remove smoke from the building is often implemented ahead of or simultaneous with fire control efforts. Ventilation tactics involve both horizontal ventilation through existing building openings and vertical ventilation, often involving cutting roof openings. While firefighting texts and training programs do address the need for coordination, control, and timing, ventilation frequently results in increased fire intensity and in some cases precipitates extreme fire behavior. This is not to say that deliberate and substantial increases in ventilation cannot have a positive impact on life safety and fire control. When used correctly, this strategy is extremely effective. Fire control and ventilation strategies are closely related. Given the tendency to vent aggressively, firefighters in the United States generally use flow rates ranging from 375 lpm (100 gpm) to 1100 lpm (300 gpm) in offensive firefighting operations (tending towards the middle of this range). In contrast, the philosophical approach to ventilation strategies in Europe and Australia is quite different. Increasing ventilation is approached much more cautiously and deliberately and limiting the air supply to the fire (rather than removing the smoke and increasing air supply) is equally likely. Ventilation tactics focus largely on horizontal ventilation. Ventilation operations are more closely controlled with a strong focus on integration of fire control and ventilation operations. Correspondingly, firefighters in Europe and Australia typically use flow rates ranging from 115 lpm (30 gpm) to 750 lpm (198 lpm), tending towards the lower end of this range. 1 It is important to note that these philosophic approaches are extremely generalized and do not necessarily reflect the practices used by a given fire department. CFBT-US, LLC Page 2

Key Questions To start this examination of best practices in the application of ventilation strategies it is necessary to address several questions: 1. What is ventilation? 2. How does it impact fire development and potential for extreme fire behavior? 3. How do ventilation strategies support incident priorities Ventilation For many years, firefighters in the United States were taught that ventilation is the systematic removal of heat, smoke, and fire gases, and replacing them with cooler air (IFSTA, 2007, p. 541) Is this really true? Ventilation is actually the exchange of the atmosphere inside a building with that on the outside. This process goes on all the time and does not necessarily involve heat, smoke, and toxic gases. However, when a compartment fire occurs, ventilation involves supply of air (oxygen) to the fire and exhaust of smoke and hot gases. The extent of this process varies considerably, but if firefighters arrive and observe smoke issuing from the building, some ventilation is taking place. The extent and nature of ventilation may change due to fire effects (e.g., failure of window glass) or as a result of firefighting operations (e.g., opening a door to make entry or deliberately making an opening to change ventilation). Ventilation and Fire Development Ventilation and changes in ventilation have a major influence on compartment fire behavior. A simple combustion model such as the fire tetrahedron can be used to help understand why ventilation is such a critical factor. Figure 2. Fire Tetrahedron Combustion, as an oxidation reaction requires sufficient oxygen to react with the available fuel. When sufficient oxygen is available, fire development is influenced predominantly by fuel characteristics and availability. However, in a compartment fire oxygen may be limited by the compartments ventilation profile. When insufficient oxygen is available, the fire becomes ventilation controlled and fire development is influence predominantly by oxygen concentration. When an incipient or growth stage fire is fuel controlled, a greater amount of ventilation will increase the heat release rate required to reach flashover and slow the time to flashover. This results from convective heat loss as hot smoke and gases exit the compartment. Thermal energy not retained within the compartment is not available to increase pyrolysis and the speed of the combustion reaction. In this situation, there is sufficient atmospheric oxygen to sustain flaming combustion, but loss of thermal energy from the compartment is limiting fire development. On the other side of this equation, less ventilation reduces the heat release rate required and speeds CFBT-US, LLC Page 3

the time to flashover, unless the fire becomes ventilation controlled and enters the decay stage before reaching flashover. Factors that influence the potential for a compartment fire to become ventilation controlled include the size of the compartment and compartmentation within the structure, the ventilation profile (including existing openings; leakage of air and smoke; and the heating, ventilation, and air conditioning system). Given sufficient ventilation and fuel that will provide a sufficient heat release rate, a growth stage compartment fire will reach flashover. However, this does not mean that the fire will not become ventilation controlled. As illustrated in Figure 2, the lowering neutral plane at compartment openings reduces the size of the inlet providing air to the fire. Reduced inlet size may result in the fire becoming ventilation controlled. Figure 3. Neutral Plane and Burning Regime Note: Photos adapted from National Institute of Standards and Technology (NIST) ISO- Room/Living Room Flashover. The fire tetrahedron can be used as a framework to examine the influence of increased air supply to a ventilation controlled compartment fire as illustrated in Table 1. CFBT-US, LLC Page 4

Table 1. Impact of Increased Air to a Ventilation Controlled Fire Heat Fuel Oxygen Chemical Chain Reaction Heat Release Rate Increases Oxygen Concentration Increases Burning Rate Increases Thermal Energy is Lost Due to Convection Gas Phase Fuel (Smoke) Concentration Decreases Gas Phase Fuel and Smoke Mix at the Hot Gas Layer Interface Most fires that progress beyond the incipient stage are ventilation controlled at the point where the fire department arrives. It is essential that firefighters recognize that changes in the ventilation profile have the potential to cause significant changes in fire behavior. Ventilation Induced Extreme Fire Behavior The potential for extreme fire behavior under ventilation controlled decay conditions is discussed at greater length in Extreme Fire Behavior: Understanding the Hazards (Hartin, 2008). However, it is important to review and reinforce how changes in ventilation profile can impact ventilation induced flashover and backdraft. The primary difference between ventilation induced flashover and backdraft is the speed with which the heat release rate increases. Backdraft involves a deflagration (explosion) resulting in an extremely rapid and transient release of energy. On the other hand, ventilation induced flashover involves a rapid transition of a ventilation controlled fire to the fully developed stage with a sustained increase in heat release rate (as illustrated in Figure 3). Figure 4. Ventilation Induced Extreme Fire Behavior CFBT-US, LLC Page 5

Changes to the Ventilation Profile As previously mentioned, the ventilation profile may change for a variety of reasons. Figure 5 illustrates the three ways in which the ventilation profile may change 1) unplanned ventilation as a result of fire effects or human action, 2) tactical ventilation, or 3) tactical anti-ventilation. Figure 5. Ventilation Concept Map Normal ventilation involves the exchange of air inside a structure with outside air. As a fire develops, this exchange provides to support combustion and allows some smoke to escape. As previously discussed, air inside the structure and this normal building ventilation has a significant impact on fire development. One way in which this ventilation profile can change is unplanned ventilation due to human action or fire effects. For example, occupants exiting the structure leaving a door or window open or the fire may cause window glazing to fail due to temperature differential on the two sides of the glass surface. In addition to these causes of unplanned ventilation, firefighters making entry or performing unplanned or uncoordinated ventilation can also create undesirable changes in the ventilation profile. In addition to unplanned openings, wind can be a significant factor when the ventilation profile changes by increasing the volume of air supplied to the fire and/or creating draft effects. While appropriate and planned changes in ventilation can significantly improve conditions inside the building, inappropriate or unplanned ventilation can adversely impact conditions and speed fire development. It is essential to anticipate potential changes to the ventilation profile and their effect on fire behavior. Managing Changes to Ventilation While unplanned ventilation can have significant adverse impact on fire development, appropriate changes in ventilation profile can improve tenability; increase the safety of occupants, and firefighters, and aid in the effectiveness of fire control operations. As discussed earlier in this paper, there are two fundamental strategies for changing ventilation profile, tactical ventilation and tactical anti-ventilation. CFBT-US, LLC Page 6

Tactical Ventilation: Planned and systematic removal of heat, smoke, and fire gases and introduction of fresh air. Tactical ventilation is accomplished by using exhaust and inlet openings to create a selected channel for the flow of hot smoke and fire gases and air. Tactical Anti-Ventilation: Planned and systematic confinement of heat, smoke, and fire gases and exclusion of fresh air. Tactical anti-ventilation is accomplished by closing openings (or keeping openings that are already closed in that position) or pressurizing adjacent compartments to prevent smoke infiltration. Figure 6. Fundamental Strategies Strategic and Tactical Decision-Making When considering action to change the ventilation profile, it is useful for firefighters to keep in mind the advice of a old Japanese proverb: Vision without action is a daydream. Action without vision is a nightmare. In firefighting operations, strategies are what will be done and tactics are how the strategies will be accomplished. Both strategies and tactics must be based on the problems presented by the incident. Consider how tactical ventilation and anti-ventilation influence fire behavior and the environment inside the building. Changes in the ventilation profile can influence fire development, potential for extreme fire behavior, and tenability. The complexity of ventilation decision making is rooted in interrelated and sometimes conflicting outcomes. For example, horizontal ventilation may raise the level of the hot gas layer, temporarily increasing tenability, but (without rapid fire control) the resulting increase in heat release rate may result in a ventilation induced flashover. In other cases, the desired tactic may require more time than is available. Vertical ventilation can have a significant positive impact in many cases, but time is required to access the roof and make the necessary opening. If roof cutting is necessary, this time must be factored into the plan of action. Purpose The first decision in developing a ventilation plan is strategic. What is the purpose of the ventilation strategy? Ventilation strategies can support life safety and fire control tactical priorities. In many cases, tactical ventilation aids in fire control as well as reducing the risk to firefighters and building occupants. CFBT-US, LLC Page 7

Life Safety: Ventilation actions taken to provide or maintain a tenable environment inside the building. This can include tactical ventilation to raise the hot gas layer and draw the fire away from firefighters and occupants or tactical anti-ventilation to confine the fire and smoke or limit fire growth. Fire Control: Ventilation actions to support fire control fire limits fire spread by drawing heat in a specific direction, frequently away from uninvolved fuel or tactical antiventilation to limit the flow of air to the fire (reducing heat release rate) or to confine the spread of smoke and fire. Consider if removal of smoke and replacement with fresh air (tactical ventilation) an effective strategy or is confinement of smoke and limiting entry of air (tactical anti-ventilation) more appropriate. Frequently the answer is both, either sequentially (first one and then the other) or concurrently (in different parts of the building). After making these decisions, it s on to tactics. Table 2 outlines the critical questions in tactical decision making for tactical ventilation and tactical anti-ventilation. Table 2. Ventilation Decision-Making Tactical Ventilation Direction and Location? Method? Sequence? Tactical Anti-Ventilation Location? Method? Sequence? Tactical Ventilation Decisions Direction and Location: In what direction should the smoke and heat be moved? The first part of answering this question is to determine if horizontal or vertical ventilation is indicated. The second is determining the location of the exhaust opening (where smoke will be discharged) and the inlet opening (where air will be introduced). Method: In many cases, tactical ventilation may be accomplished using the pressure and buoyancy of the hot smoke and gases inside the structure along with ambient wind conditions. This is referred to as natural ventilation. However, this is not always adequate to accomplish our objectives. Assisted ventilation involves adding energy through mechanical or hydraulic means to influence the air track. This typically involves use of a positive pressure fan (blower) to introduce air at the inlet opening to create a positive pressure or discharging a fog stream through the exhaust opening to create a negative pressure. Sequence: Ventilation tactics must be appropriately sequenced in relation to fire control actions. Tactical ventilation must not be performed prior to placement of hoselines to deal with the increased heat release rate that will result from additional air supplied to the fire. However, positive pressure ventilation in conjunction with fire attack (positive pressure attack) requires that ventilation be performed prior to making entry into the structure. Negative pressure ventilation should be performed after fire control (as you are working at the exhaust opening). CFBT-US, LLC Page 8

Often, tactical anti-ventilation and tactical ventilation are used in sequence. Door control may be maintained prior to and after entry and tactical ventilation implemented after fire control has been accomplished. In other cases, increased ventilation may result from making entry through a window for search, and anti-ventilation used (close the door to the compartment) to limit its effect to that uninvolved, but smoke logged compartment. Tactical Anti-Ventilation Decisions Location: Effective use of tactical anti-ventilation requires identification of the location of inlet openings and potential barriers to movement of air and smoke. One critical opening is the entry point for firefighting and rescue operations. However, it is also important to think about building compartmentation (location of doors) and potential openings where unplanned (e.g., fire caused) ventilation may occur. Method: In many cases, anti-ventilation will be a simple as maintaining door control at the point of entry (closing the door to as great an extent as possible after firefighters and hoselines have been deployed to the interior of the building. In other cases, it may involve closing interior doors to limit movement of smoke and air. Windows that have failed to fire effects present a greater challenge. However, research is currently underway to explore options for controlling this type of opening (in high-rise buildings). In March 2008 National Institute of Standards and Technology and the Fire Department of the City of New York (FDNY) conducted tests of a device to control inlet openings in wind driven high-rise fires (see Figure 7). Figure 7. Prototype Wind Control Device Note: Photo from NIST Evaluates Firefighting Tactics in NYC High-rise Test Sequence: As with tactical-ventilation, anti-ventilation actions must be sequenced with fire control (i.e., before, during, or after fire control is established). CFBT-US, LLC Page 9

Summary Effective ventilation can reduce the potential for extreme fire behavior and can limit or channel fire spread in a specific direction. However, Ineffective and inappropriate ventilation can cause extreme fire behavior or may spread the fire in an undesired direction. Actions taken to influence (maintain or change) the ventilation profile must be based on knowledge of their influence on fire behavior and the environment inside the building as well as coordinated with other tactical operations. Effective and appropriate ventilation tactics in coordination with fire attack result in: A more survivable environment Faster firefighting operations Limitation of fire spread Reduced extreme fire behavior Less property damage International best practices can be drawn from the philosophical differences between the fire services of the United States, Europe, and Australia. Safety and effectiveness of fireground operations can be improved if the following considerations are addressed in the selection and implementation of ventilation strategies and tactics: Base ventilation decision-making on an understanding of fire dynamics. Recognize and address the influence of both sides of the ventilation equation: Smoke and Air Anticipate the impact of unplanned ventilation due to fire effects Integrate fire control and ventilation strategies. CFBT-US, LLC Page 10

References Shaw, E. (1876). Fire protection. London: Charles and Edwin Layton. Braidwood, J. (1830). On the construction of fire-engines and apparatus, the training of firemen and the methods of proceeding in cases of fire. Edinburg: Royal Society of Edinburg Braidwood, J. (1866). Fire prevention and extinction. London: Bell and Daldy Fried, E. (1972). Fireground tactics (1972). Chicago: H. Marvin Ginn National Institute of Standards and Technology (NIST). (n.d.) ISO-Room/Living Room Flashover. (Available from National Institute of Standards and Technology, Building Fire Research Laboratory, 100 Bureau Drive, Stop 8600, Gaithersburg, MD 20899-8600) Hartin, E. (2008, April). Extreme fire behavior: Understanding the hazards. Paper presented at IV Stručni Skup Vatrogasaca, Opatija, Croatia. International Fire Service Training Association (IFSTA). (2007) Essentials of firefighting, (5 th ed.). Stillwater, OK: Fire Protection Publications. National Institute of Standards and Technology(NIST) (2008, March 22). NIST evaluates firefighting tactics in NYC high-rise test. ScienceDaily. Retrieved March 27, 2008, from http://www.sciencedaily.com /releases/2008/03/080318182728.htm CFBT-US, LLC Page 11