Fire and Rescue Service Operational Guidance. GRA 5.8 flashover, backdraught and fire gas ignitions
|
|
|
- Erin Maude Carroll
- 9 years ago
- Views:
Transcription
1 Fire and Rescue Service Operational Guidance GRA 5.8 flashover, backdraught and fire gas ignitions
2 Generic Risk Assessment 5.8 Flashover, backdraught and fire gas ignitions August 2009 London: TSO
3 Published by TSO (The Stationery Office) and available from: Online Mail, Telephone, Fax & TSO PO Box 29, Norwich, NR3 1GN Telephone orders/general enquiries: Fax orders: Textphone: and other Accredited Agents Customers can also order publications from: TSO Ireland 16 Arthur Street, Belfast BT1 4GD Tel Fax Published with the permission of the Department for Communities and Local Government on behalf of Her Majesty s Stationery Office. Crown Copyright 2009 ISBN Copyright in the typographical arrangement and design rests with the Crown. This is a value added publication which falls outside the scope of the HMSO Class Licence. Applications for reproduction should be made to Office of Public Sector Information, Information Policy Team, Kew, Richmond, Surrey, TW9 4DU.
4 The Generic Risk Assessments in this series only apply to England. Contents SECTION 1 GRA 5.8 Flashover, backdraught and fire gas ignitions 5 Scope 5 Significant hazards and risks 5 Flashover 5 Backdraught 5 Fire gas ignitions 6 Key control measures 7 Recognition of the signs of backdraught and flashover 7 Training 8 Pre-determined attendance 8 Personal protective equipment 8 Incident command and control 9 Additional equipment 9 Technical references 10 Glossary 10 Neutral Pressure Place 10 Deflagration 10 Pyrolysis 10 SECTION 2 Summary of GRA 5.8 Flashover, backdraught and fire gas ignitions 11
5
6 SECTION 1 GRA 5.8 Flashover, backdraught and fire gas ignitions Scope This generic risk assessment (GRA) examines the hazards, risks and controls that relate to Fire and Rescue Service staff and others who may be affected when the phenomenon of Flashover, Backdraught or Fire Gas Ignition is experienced. As with all GRAs, this assessment provides a starting point for FRSs to conduct their own assessments within the context of local conditions and existing organisational arrangements. Significant hazards and risks Flashover In a compartment fire there may come a stage where the total thermal radiation from the fire plume, hot gases and hot compartment boundaries (ceilings and walls) causes the radiative ignition of all exposed combustible surfaces within the compartment. Where the compartment is adequately ventilated, this sudden and sustained transition of a growing fire to a fully developed fire is known as a flashover. Backdraught A backdraught is where limited ventilation can lead to a fire in a compartment producing fire gases containing significant proportions of partial combustion products and unburnt pyrolysis products. If these accumulate, the admission of air when an opening is made to the compartment can lead to a sudden deflagration. This deflagration moving through the compartment and out of the opening is a backdraught. There are two scenarios of which firefighters must be fully aware: Scenario 1 If the fire is still burning within a compartment when the door is opened, especially if the combustion gases are not escaping, the incoming air will mix with the gases and create an explosive mixture. If the gases within the compartment are hot enough, they will auto-ignite and flame will spread back into the compartment along with the fresh air. This would result in rapid fire growth, but not necessarily in a backdraught. Alternatively, if the gases are not sufficiently hot they will only be ignited once sufficient oxygen has reached the gases surrounding the fire. The flame will then travel across the compartment towards, and out of the doorway, driven by the expanding gases behind it. 5
7 Scenario 2 A more dangerous situation can occur if the fire in the compartment has almost died out. Once the door is opened air flows in and an explosive mixture may be created. There is the potential for ignition of these gases not to occur immediately. Once the firefighters enter the room however, and start to disturb the contents (e.g. turning over), an ignition source may be exposed and result in total flame engulfment. This is defined as a delayed backdraught. Fire gas ignitions Fire gas ignitions occur when gases from a compartment fire are leaked into an adjacent compartment and mixed with the air within this additional area. This mixture may then fall within the appropriate flammable limits that if ignited, will create an increase in pressure either with or without explosive force. Where this process occurs it is not necessary for an opening to be opened for such ignition to take place. If an explosive force is experienced, this is commonly termed a smoke explosion. Where an ignition occurs with much less pressure, the term flash fire is more appropriate. The backdraught, flashover and fire gas ignition phenomena described above can have potentially fatal outcomes. It should be recognised that although their outcomes may be similar the phenomena themselves are in fact significantly different in terms of the following: their pre-conditions evolution recognisable indicators. At one incident, in the same structure, there may well exist the preconditions for each phenomenon. Further detailed information of the nature and preconditions for backdraught, flashover and fire gas ignitions is provided in the Fire and Rescue Service Manual Volume 2 Fire Service Operations, Compartment Fires and Tactical Ventilation. Experience has shown that standard personal protective equipment (PPE), in itself, will not afford adequate protection against the effects of either flashover or backdraught. Therefore, it is vital that FRSs consider all the key control measures in order to reduce the risk to personnel to a tolerable level. 6
8 Key control measures FRSs should consider how they control the hazards and risks described above. Key measures are as follows. Recognition of the signs of backdraught and flashover The first consideration that there is a possibility of a backdraught occurring will be dependant upon the fire history. Therefore, as much information as possible should be gathered in the early stages of the incident. External signs of backdraught Fire in a compartment with limited ventilation: Fire has been burning for some time Fire gases being pushed out under pressure from gaps Windows blackened with no visible signs of flame Fire gases pulsing out from gaps. Internal signs of backdraught Fire in a compartment with limited ventilation: Low neutral pressure plane Darkening of fire gases Inrush of air and fire gases forced out, through the opening Pulsation of fire gases through an opening Deflagration through the opening. Signs of flashover Flames visible in the fire gases Combustible materials gassing off due to pyrolysis High temperatures, and increasing rate of combustion Neutral plane moving down Sudden increase in development of fire Pyrolysis at floor level in the compartment. 7
9 Training The level and nature of training undertaken should be based upon an informed assessment of the operational need for each Fire and Rescue Service and within agreed guidance for competency based training (CBT). Personnel engaged in an operational firefighting role should receive information instruction and training which should include: chemistry of combustion the effects of walls and the ceiling on the fire plume signs and symptoms of backdraught, flashover and fire gas ignitions door entry and gas cooling procedures safe system of work for dealing with incidents where flashover and backdraught may occur physiological stress and its management. The outcomes of training must be evaluated to ensure that the training is: appropriate effective up-to-date meeting the identified operational need. Pre-determined attendance FRSs should ensure that the operational response to a building fire will be sufficient to allow relevant safe systems of work to undertake the activity. This will initially be determined by information received from the caller and followed and supplemented by the assessment of the Incident Commander. Personal protective equipment PPE manufactured to the current accepted standard should be worn. When choosing suitable protective garments, the standard of clothing worn beneath the PPE should also be considered. Retained and auxiliary personnel may not have sufficient protection afforded by this clothing and therefore appropriate guidance/restrictions should be provided. 8
10 Incident command and control The National Incident Command System should be adopted on arrival at the incident. Where a high risk of backdraught is identified, consideration should be given to the initial adoption of defensive firefighting tactics. Detailed guidance on operational tactics is published in the Fire and Rescue Service Manual, Volume 2, Fire Service Operations Incident Command, 3rd Edition Ventilation of the premises should be conducted in a controlled and considered manner with due account taken of wind conditions. Effective communications are essential for this to be achieved. Ventilation points and exposed risks should be covered by water sprays to reduce the risk of external fire spread. Suitable communications will be needed to ensure that the Incident Commander and sector commanders are able to communicate at all times. The area outside the building on fire should be controlled (Inner Cordon Management) to reduce the number of persons at risk to the minimum necessary should a backdraught occur. This may include the tactical positioning of breathing apparatus entry control boards and fire appliances. Additional equipment An informed assessment of the risks within a FRS area will allow FRSs to consider the provision, and use of any additional equipment. Equipment may include: thermal imaging cameras ventilation tools hose reel spray branches PPV fans. 9
11 Technical references 1 Table of contents, Volume 3 Guide to Operational Risk Assessment 2 Fire and Rescue Service Manual Volume 2 Compartment Fires and Tactical Ventilation (1997) 3 Fire and Rescue Service Manual, Volume 2, Fire Service Operations Incident Command, 3rd Edition 2008 TSO 4 The principles of Operational Training Fire Service Circular 5/96 5 Institute of Occupational Medicine; Home Office, FRDG Fire Research Reports and Memoranda, 18/96 6 Study of the Physiological Effect of Wearing BA (Institute of Occupational Medicine). DFM letter and DCO letter 8/1997 (Management of Physiological Stress) 7 GRA 3.6 Fighting Fires Using PPV, HMSO BS EN 469 Protective clothing for firefighters & Personal Protective Equipment at Work: guidance on Regulations: Personal Protective Equipment at Work Regulations Dynamic Management of Risk at Operational Incidents, HMSO Home Office Technical Bulletin 1/97 Breathing Apparatus Command and Control 11 Euro Firefighter Global firefighting Strategy and Tactics, Command and Control, Firefighter Safety Paul Grimwood FIFireE Glossary Neutral Pressure Plane Fire in a compartment causes smoke and gases to rapidly expand with the hot gases rising due to their lower density and greater buoyancy. This results in a higher (positive) pressure in the fire room than the areas outside of the compartment. The forces, once fully developed, create an equilibrium whereby negative pressure relative to the outside, exists in the lower part of the room an positive pressure exists in the higher levels. Where these two zones meet is known as the Neutral Pressure Plane. Deflagration To burn or cause to burn with great heat and intense light. Pyrolysis Transformation of a substance produced by the action of heat. 10
12 SECTION 2 Summary of GRA 5.8 Flashover, backdraught and fire gas ignitions Ref. No Task Hazard Risk Persons at risk Control Measures 1 Entering an outer compartment potentially affected by a fire gas ignition Rapid fire spread Total flame engulfment of firefighters within the fire compartment Burns and scalds Fire and explosion Blast injury Wholetime Day crewed Retained Volunteers Other emergency service personnel Operational procedures as per FRS policy and supervision Training in identification of indicators and methods of attack PPE manufactured to the current accepted standard 2 Opening up a compartment containing oxygen starved fire Rapid fire spread/backdraught Burns and scalds Fire and explosion Blast injury Public Wholetime Day crewed Retained Volunteers Other emergency service personnel Operational procedures as per FRS policy and supervision Training in identification of indicators and methods of attack PPE manufactured to the current accepted standard 3 Working in compartment with flammable gases present and exposing a source of ignition Total flame engulfment of firefighters within the fire compartment Burns and scalds Fire and explosion Blast injury Public Wholetime Day crewed Retained Volunteers Public Operational procedures as per FRS policy and supervision Training in identification of risks. PPE manufactured to the current accepted standard 11
13 Ref. No Task Hazard Risk Persons at risk Control Measures 4 Carrying out tactical ventilation Rapid fire spread/backdraught Burns and scalds Fire and explosion Blast injury Wholetime Day crewed Retained Volunteers Other emergency service personnel Operational procedures as per FRS policy and supervision Training in identification of indicators and methods of ventilation PPE manufactured to the current accepted standard 5 Opening up a compartment where the thermal radiation generated by the fire is high, causing the room contents to give off flammable gases. Rapid fire spread/flashover Burns and scalds Fire and explosion Blast injury Public Wholetime Day crewed Retained Volunteers Other emergency service personnel Public Operational procedures as per FRS policy and supervision Training in identification of indicators and methods of attack PPE manufactured to the current accepted standard Explanatory Key Description Reference number for the risk Task the specific activity being carried out Hazard Hazard present giving rise to the risk Risk the chance, high or low, that somebody could be harmed by these and other hazards, together with an indication of how serious Persons at risk this should detail either employee, and / or member of public Control measures That could be used by the Service to reduce the risk 12
GENERIC RISK ASSESSMENT 3.6 FIGHTING FIRES - USING POSITIVE PRESSURE VENTILATION
GENERIC RISK ASSESSMENT 3.6 FIGHTING FIRES - USING POSITIVE PRESSURE VENTILATION SCOPE This document examines the hazards, risks and controls that relate to the use of Positive Pressure Ventilation (PPV)
ARRANGEMENTS FOR HANDLING HERITAGE APPLICATIONS NOTIFICATION TO THE SECRETARY OF STATE (ENGLAND) DIRECTION 2009
DEPARTMENT FOR COMMUNITIES AND LOCAL GOVERNMENT Communities and Local Government Circular 08/2009 Department for Communities and Local Government Eland House, Bressenden Place, London SWIE 5DU November
Fire Development and Fire Behavior Indicators
Battalion Chief Ed Hartin, MS, EFO, MIFireE, CFO Introduction Building Factors, Smoke, Air Track, Heat, and Flame (B-SAHF) are critical fire behavior indicators. Understanding the indicators is important,
CODE OF RECOMMENDED PRACTICE ON LOCAL AUTHORITY PUBLICITY
Department for Communities and Local Government Communities and Local Government Circular 01/2011 Department for Communities and Local Government Eland House, Bressenden Place, London SWIE 5DU 31 March
Treaty Series No. 12 (2013)
Treaty Series No. 12 (2013) Exchange of Letters between the Government of the United Kingdom of Great Britain and Northern Ireland and the Government of the French Republic Amending the Agreement between
Flashover. Newsletter by Vincent Dunn-July 2000
Newsletter by Vincent Dunn-July 2000 Flashover Flashover! It is the most dangerous time of a fire. When the room bursts into flame, flashover has occurred. The scientific definition of flashover states
Controlling fire and explosion risks in the workplace
Controlling fire and explosion risks in the workplace A brief guide to the Dangerous Substances and Explosive Atmospheres Regulations Introduction to DSEAR This leaflet provides a brief introduction to
December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?
Photo By: Steve Spak December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference? What is a backdraft explosion and how does differ from a flashover? Explosions kill and injure
Examples of pressure systems and equipment are:
Pressure systems A brief guide to safety Introduction Pressure systems A brief guide to safety If pressure equipment fails in use, it can seriously injure or kill people nearby and cause serious damage
Fire Safety Risk Assessment Checklist for Residential Care Premises
Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or
Surrey Fire & Rescue Service Report of Fire
SEFIG/FI/6 Issue 1 Surrey Fire & Rescue Service Report of Fire Incident No.: 007905/2015 Address: Clandon Park The Street West Clandon, GU4 7RQ Owner: National Trust Date and time: Friday 29 th April 2015
Natural Gas Emergencies
Natural Gas Emergencies Purpose To protect the personnel within the department, and citizens from the hazards involved in a natural gas emergency. The Incident Commander is to use his/her best judgment
Settlement Agreements
July 2013 Code of Practice 4 Settlement Agreements (under section 111A of the Employment Rights Act 1996) Published by TSO (The Stationery Office) and available from: Online www.tsoshop.co.uk Mail, Telephone,
March 2015 Code of Practice 1 CODE OF PRACTICE ON DISCIPLINARY AND GRIEVANCE PROCEDURES
March 2015 Code of Practice 1 CODE OF PRACTICE ON DISCIPLINARY AND GRIEVANCE PROCEDURES Published by TSO (The Stationery Office) and available from: Online www.tsoshop.co.uk Mail, Telephone, Fax & E-mail
FLA S FIRE SAFETY INITIATIVE
Improving Workers Lives Worldwide FLA S FIRE SAFETY INITIATIVE Preventing fires and saving lives by empowering workers and factory managers SCENARIO 1 OCCURS AT FACTORY ABC, WHICH HAS NOT IMPLEMENTED NECESSARY
WORKING IN CONFINED SPACES GUIDELINES
WORKING IN CONFINED SPACES GUIDELINES Contents 1 Introduction... 2 2 Scope... 2 3 Definitions... 2 4 Responsibilities... 3 4.1 Permit Authoriser... 3 4.2 Permit Receiver... 3 4.3 Responsible UOW Officer...
Fire and Rescue Service Operational Guidance. GRA 5.10 Working at heights
Fire and Rescue Service Operational Guidance GRA 5.10 Working at heights Generic Risk Assessment 5.10 Working at heights October 2009 London: TSO Published by TSO (The Stationery Office) and available
Material Safety Data Sheet
1 IDENTIFICATION OF THE SUBSTANCE AND COMPANY a) SUBSTANCE: Natural Gas b) COMPANY: Bord Gáis Éireann PO Box 51 Gasworks Road Cork Telephone: (021) 453 4000 Emergency Telephone: 1850 20 50 50 2 COMPOSITION/INFORMATION
IFE Level 3 Certificate for Operational Supervisory Managers in Fire and Rescue Services (VRQ)
IFE Level 3 Certificate for Operational Supervisory Managers in Fire and Rescue Services (VRQ) Introduction The IFE Level 3 Certificate for Operational Supervisory Managers in Fire and Rescue Services
FLAMMABLE LIQUIDS COMPLIANCE NOTE
Issued by: Heather Rice Page: 1 of 7 COMPLIANCE NOTE INTRODUCTION This document provides additional guidance to support the Arrangement on Flammable Liquids (Ref No. CYC/HS/A27) CONTENTS Section Topic
Guide Main use Offices and shops
offices and shops Published by TSO (The Stationery Office) and available from: Online www.tsoshop.co.uk Mail, Telephone, Fax & E-mail TSO PO Box 29, Norwich, NR3 1GN Telephone orders/general enquiries:
UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS
Fire Safety Technical Guide UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS 1.0. BACKGROUND 1.1. The Regulatory Reform (Fire Safety) Order (known Fire Safety Order) applies to England and Wales (Northern
Essence of Care. Benchmarks for Communication
Essence of Care 2010 Document Purpose Best Practice Guidance ROCR Ref: 0 Gateway Ref: 14641 0 Title Author Publication Date Target Audience ESSENCE OF CARE 2010 DEPARTMENT OF HEALTH 1ST OCTOBER 2010 PCT
The Current Knowledge & Training Regarding Backdraft, Flashover, and Other Rapid Fire Progression Phenomena
The Current Knowledge & Training Regarding Backdraft, Flashover, and Other Rapid Fire Progression Phenomena Gregory E. Gorbett, CFPS, MIFireE Professor Ronald Hopkins, MS, CFPS Presentation at the National
notes Video User s s Guide Accident Involving Radioactive Material
Emergency Response to a Transportation Accident Involving Radioactive Material DISCLAIMER Viewing this video and completing the enclosed printed study material do not by themselves provide sufficient skills
NEW FIRE SAFETY LEGISLATION
NEW FIRE SAFETY LEGISLATION The Fire and Rescue Services (Northern Ireland) Order 2006 The Fire Safety Regulations (Northern Ireland) 2010 Fire Safety legislation changed A SHORT GUIDE TO MAKING YOUR PREMISES
Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition
Compliance Document for New Zealand Building Code Clause F7 Warning Systems Fourth Edition Prepared by the Department of Building and Housing This Compliance Document is prepared by the Department of Building
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.
Hazardous Materials Response Clear Creek Fire Authority This plan provides a basic philosophy and strategic plan for hazardous materials situations. All Clear Creek Fire policies and procedures, unless
Fire and Rescue Service Operational Guidance
Fire and Rescue Service Operational Guidance GRA 3.5 Fighting fires in farms Generic Risk Assessment 3.5 Fighting fires in farms June 2011 London: TSO Published by TSO (The Stationery Office) and available
IN CASE OF EMERGENCY. Emergency Telephone Number 112
IN CASE OF EMERGENCY Emergency Telephone Number 112 Police, Fire, Ambulance Dial 112 in case of fire, medical emergency, serious or life threatening traffic or other accident. Tell the operator: What has
FIRE SAFETY GUIDANCE NOTE Regulatory Reform (Fire Safety) Order 2005
FIRE SAFETY GUIDANCE NOTE Regulatory Reform (Fire Safety) Order 2005 Number: GN66 This Guidance Note provides advice on the requirements of the Regulatory Reform (Fire Safety) Order 2005 and how to complete
: GLADE Aerosol - Lavender
1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING Product information Product identifier : Relevant identified uses of the substance or mixture and uses advised against : Air Freshener
Gambling (Licensing and Advertising) Act 2014
Gambling (Licensing and Advertising) Act 2014 CHAPTER 17 Explanatory Notes have been produced to assist in the understanding of this Act and are available separately 6.00 Gambling (Licensing and Advertising)
FIRE INVESTIGATOR LEAD EVALUATOR HANDBOOK
LEAD EVALUATOR HANDBOOK Reference Material needed for this course: NFPA 1033: Standard for Professional Qualifications for fire Investigator, 2009 Edition Jones and Bartlett, Fire Investigator, 3 rd Edition
Treaty Series No. 28 (2005) Agreement
The Agreement was previously Published as France No. 1 (2005) Cm 6444 Treaty Series No. 28 (2005) Agreement between the Government of the United Kingdom of Great Britain and Northern Ireland and the Government
Written schemes of examination
Written schemes of examination Pressure Systems Safety Regulations 2000 Under the Pressure Systems Safety Regulations 2000, users and owners of pressure systems are required to demonstrate that they know
EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT
EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT OVERVIEW ASSESSING THE RISK RELATIONSHIP BETWEEN FIRES AND EXPLOSIONS CLASSIFYING HAZARDOUS AREAS INTO ZONES
LINCOLNSHIRE FIRE AND RESCUE
LINCOLNSHIRE FIRE AND RESCUE FIRE RISK ASSESSMENT FOR SMALLER PREMISES AND THE WORKPLACE FIRE PRECAUTIONS LEGISLATION The Fire Precautions (Workplace) Regulations 1997 The Fire Precautions (Workplace)
A Guide to the European Standard for Safety Storage Cabinets (BS EN 14470-1)
White Paper A Guide to the European Standard for Safety Storage Cabinets (BS EN 14470-1) Published: May 2012 Author: Greg Smith, Labtex In this Labtex White Paper: Safety Storage Cabinets Overview What
Safe Operating Procedure
Safe Operating Procedure (Revised 07/09) HOT WORK PERMIT OPERATIONS (For assistance, please contact EHS at (402) 472-4925, or visit our web site at http://ehs.unl.edu/) Authority In recognition of the
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
CONFINED SPACE PROCEDURE
Document uncontrolled when printed Procedure ID no 0460/05 CONFINED SPACE PROCEDURE This procedure is applicable to: All Department of Education and Children's Services employees. DOCUMENT CONTROL Managed
Fire and Rescue Authorities Operational Guidance
Fire and Rescue Authorities Operational Guidance GRA 2.1 Rescues from confined spaces Generic Risk Assessment 2.1 Rescues from confined spaces April 2013 London: TSO Published by TSO (The Stationery Office)
WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA-D
1. PRODUCT AND COMPANY IDENTIFICATION Product information Product name : WINDEX ORIGINAL GLASS CLEANER WITH AMMONIA- D Recommended use : Hard Surface Cleaner Manufacturer, importer, supplier : S.C. Johnson
Safety Storage Cabinets
Safety Storage Cabinets Safe storage of flammables? The workplace without a fire resistant Safety Storage Cabinet Dangers, risks and your disadvantages... STORAGE ROOM Transport/working time - Increased
SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture
Revision Date: 05/19/2015 Date of issue: 05/19/2015 Version: 1.0 SECTION 1: IDENTIFICATION 1.1. Product Identifier Product Form: Mixture Product Name: 10X Spheroid Formation ECM Product Code: 3500-096-01
English Victorian Semi-Detached House Fire.
English Victorian Semi-Detached House Fire. The Front and Side Plan View of an English Victorian semi-detached house, above, consisting of three floors and a basement of traditional brick construction
small and medium places of assembly
small and medium places of assembly Published by TSO (The Stationery Office) and available from: Online www.tsoshop.co.uk Mail, Telephone, Fax & E-mail TSO PO Box 29, Norwich, NR3 1GN Telephone orders/general
ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600
OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done
MEMORANDUM TO THE BUSINESS, INNOVATION AND SKILLS SELECT COMMITTEE. Post-Legislative Assessment of the Further Education and Training Act 2007
MEMORANDUM TO THE BUSINESS, INNOVATION AND SKILLS SELECT COMMITTEE Post-Legislative Assessment of the Further Education and Training Act 2007 Presented to Parliament by the Secretary of State for Business,
SOUTH LYON FIRE DEPARTMENT Manual of Procedures 404
GENERAL STRUCTURAL FIRE FIGHTING Issued: February 6, 2011 Revised: March 6, 2015 Approved: Chief Mike Kennedy I. SCOPE The general structural firefighting procedure will provide guidelines to incident
Take care with oxygen Fire and explosion hazards in the use of oxygen
Fire and explosion hazards in the use of oxygen This leaflet provides information on the fire and explosion hazards in the use of oxygen. It is for anyone who uses oxygen gas in cylinders. Hazards from
Fire Safety Policy. Fire Safety Policy: May 2011 Page 1 of 6. Version 1. Scope:
Version 1 Fire Safety Policy Scope: Effective Date: Review Date: Signed Off by: Author: Policy Owned by: This policy applies to Hackney Homes Ltd working on behalf of the London Borough of Hackney July
SECTION 2: HAZARDS IDENTIFICATION Classification of the Substance or Mixture Classification (GHS-US) Not classified
Revision Date: 09/08/2014 Date of issue: 09/08/2014 Version: 1.0 SECTION 1: IDENTIFICATION Product Identifier Product Form: Fabric Product Name: Oil-Only Sorbent Product Code: All M, OSW, OBW, OPW, OS,
Compressed Gas Cylinder Program
Department of Environmental Health & Safety Procedures Compressed Gas Cylinder Program March 2010 Compressed Gas Cylinder Program Page 1 of 8 Table of Contents I. Introduction II. III. IV. Policy Scope
IGEM/UP/16 Communication 1756
Communication 1756 Design for Natural Gas installations on industrial and commercial premises with respect to hazardous area classification and preparation of risk assessments Founded 1863 Royal Charter
SURVIVE INSIDE: Employee Safety in Confined Spaces
SURVIVE INSIDE: Employee Safety in Confined Spaces This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description of the
Managing fire safety in the workplace
Managing fire safety in the workplace Health and safety information for small businesses Contents: 3 Introduction 5 Responsibilities 6 How do fires start? 7 Where do I start? 8 What is a risk assessment?
Fire Safety Requirements for Child Care Centre
Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,
SAFETY SIGNAGE PROCEDURE
Page 1 of 10 SAFETY SIGNAGE PROCEDURE 1.0 PURPOSE 1.1 To enable a reference to signage to meet legislative requirements and ensure in cases of emergency appropriate signage is visible. 2.0 SCOPE 2.1 This
Notes. Material 1. Personal Protective Equipment 2.
29CFR 1926.20(b)-Accident Reduction, 29CFR 1926.21- Safety Training & Education 29CFR 1926.20(a)-Unsafe Working Conditions 29 CFR 1910.132-138, the "Personal Protection Equipment" standard. & 20 CFR 1910.134
Fire Risk Assessment Safety Checklist
Fire Risk Assessment Safety Checklist This checklist has been prepared to help you comply with The Regulatory Reform Fire Safety Order 2005 What is the Regulatory Reform (Fire Safety) Order 2005? The Regulatory
FIRE RISK ASSESSMENT
The Regulatory Reform (Fire Safety) Order 2005 FIRE RISK ASSESSMENT Employer or other responsible person Name of Premises Address Post Code Telephone N o Name of Assessor(s) Date of Assessment Date of
MAIB SAFETY BULLETIN 1/2006. Fire on board the Bermuda registered cruise ship. Star Princess
MAIB SAFETY BULLETIN 1/2006 Fire on board the Bermuda registered cruise ship Star Princess on 23 March 2006 MAIB SAFETY BULLETIN 1/2006 This document, containing safety lessons, has been produced for marine
Bastille Court 2 Paris Garden London SE1 8ND Telephone: 020 7902 5314 Fax: 020 7902 5301 E-mail: [email protected] Web: http://www.thefpa.co.
Bastille Court 2 Paris Garden London SE1 8ND Telephone: 020 7902 5314 Fax: 020 7902 5301 E-mail: [email protected] Web: http://www.thefpa.co.uk Fire Risk Assessment Course Health & Safety at Work Inspectorate,
Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases
VENTILATION Fire is the rapid oxidation of a combustible material, releasing heat, light, smoke, and various toxic gases If a fire is contained in a building, the heat, smoke, and toxic gases will spread.
ESCAMBIA COUNTY FIRE-RESCUE 3500.015. Implemented: 7/07//10 Revised:
, Fire Chief Page 1 of 7 PURPOSE This guideline is designed to provide a standardized method of establishing and managing rehabilitation operations at the scene of an emergency or during training evolutions.
SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012
Page : 1 1. Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Trade name : Product code : Identification of the product : NILE BLUE CHLORIDE CAS No :2381-85-3
An inventory of hazardous materials used in your workplace will prove useful.
Introduction Fire Protection is an organized approach designed to prevent fires. In the event of a fire, a fire protection program will help prevent or minimize personal injuries, losses, and harm to the
sleeping accommodation
sleeping accommodation Published by TSO (The Stationery Office) and available from: Online www.tsoshop.co.uk Mail, Telephone, Fax & E-mail TSO PO Box 29, Norwich, NR3 1GN Telephone orders/general enquiries:
HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids
Flammable Liquids Storage Introduction This guideline is designed to help you store flammable liquids safely. It is based on the requirements of the Ontario Fire Code, Part 4, and of the Regulations for
Emergency Response Guide
Emergency Response Guide Honda Fuel Cell Vehicle Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel by American Honda Motor Co., Inc. Contents Key Components...2
Carriage of Dangerous Goods: Approved Derogations and Transitional Provisions
Carriage of Dangerous Goods: Approved Derogations and Transitional Provisions United Kingdom April 2012 Carriage of Dangerous Goods: Approved Derogations and Transitional Provisions Issued by: the Secretary
FIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation
FIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation Number: GN75 This Guidance Note provides information on the legislation relating to risk assessments
This leaflet provides information on
This leaflet provides information on the fire and explosion hazards in the use of oxygen. It is for anyone who uses oxygen gas in cylinders. HSE8(rev2) Hazards from oxygen Oxygen gas in cylinders is used
SAFETY AND HEALTH PROGRAM
PROGRAM NUMBER NO. PAGES 05-005 10 REVISION ISSUE DATE Revision 2 11/1/2005 SAFETY AND HEALTH PROGRAM Confined Space Entry 1.0 INTRODUCTION Confined Space Entry is a serious workplace hazard, capable of
REGULATORY REFORM (FIRE SAFETY) ORDER 2005. Fire Risk Assessment. 145 Drury Lane Covent Garden London WC2B 5TA
REGULATORY REFORM (FIRE SAFETY) ORDER 2005 Fire Risk Assessment 145 Drury Lane Covent Garden London WC2B 5TA Annex A (informative) Model pro-forma for documentation of the fire risk assessment for premises
: MR MUSCLE Window & Glass Cleaner
1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING Product information Product identifier : Relevant identified uses of the substance or mixture and uses advised against : Hard Surface
: Microscope Slide containing Various Human or Animal Blood samples
Microscope Slide containing Various Human or Animal Blood Date of issue: 01/06/2015 Revision date: 01/12/2015 Version: 1.2 SECTION 1: Identification of the substance/mixture and of the company/undertaking
FIREFIGHTER SAFETY. Stay safe during substation fires
FIREFIGHTER SAFETY Stay safe during substation fires FIREFIGHTERS AND SUBSTATIONS Electrical substations reduce the high voltages used to move electricity over long distances to the lower voltages that
Australia No. 1 (2013) TREATY
Australia No. 1 (2013) TREATY between the Government of the United Kingdom of Great Britain and Northern Ireland and the Government of Australia for Defence and Security Cooperation Perth, 18 January 2013
SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012
Page : 1 1. Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Trade name : ODIUM Product code : Identification of the product : NICOTINAMIDE ADENINE DINUCLEOTIDE
Service Standard 6.1.5. Live Fire Training
Service Standard 6.1.5 Live Fire Training Date of Issue 19 August 2013 Version Number 1.0 1. Purpose 1.1 The ongoing training of members is the cornerstone of good fire suppression in today s world. However,
Wilkins Safety Group
H & S Guidance - Flammable Liquids See also: other pages INTRODUCTION Flammable liquids are liquids with a flashpoint of 55ºC or below and hence includes all liquids that are classified as flammable, highly
OCCUPATIONAL SAFETY AND HEALTH PROGRAM
OCCUPATIONAL SAFETY AND HEALTH PROGRAM As stated in NFPA 1500, Standard on Fire Department Occupational Safety and Health Program, "Firefighting has been recognized as the most hazardous occupation in
Integrated Risk Management Planning Guidance Note 4:
Integrated Risk Management Planning Guidance Note 4: A risk assessment based approach to managing a fire safety inspection programe www.communities.gov.uk community, opportunity, prosperity Integrated
Confined spaces can be deadly. What is a confined space?
Confined spaces A brief guide to working safely This leaflet explains what you, as an employer, may need to do to protect your employees when working in confined spaces. It will also be useful to the self-employed
Fire Risk Assessment For Simple Premises
Fire Risk Assessment For Simple Premises Responsible Person (Employer or other person having control of the relevant premises) Company / Premises Name Address of Premises Postcode Primary Use of Premises
HAZARD COMMUNICATION & THE GLOBAL HARMONIZING SYSTEM EMPLOYEE TRAINING
HAZARD COMMUNICATION & THE GLOBAL HARMONIZING SYSTEM EMPLOYEE TRAINING This easy-to-use Leader s Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief
Time off for trade union duties and activities
January 2010 Code of Practice 3 Time off for trade union duties activities including guidance on time off for union learning representatives Publishedby TSO(TheStationeryOffice) availablefrom: Online www.tsoshop.co.uk
The Smoke and Carbon Monoxide Alarm (England) Regulations 2015
The Smoke and Carbon Monoxide Alarm (England) Regulations 2015 Q&A Booklet for the Private Rented Sector landlords and tenants September 2015 Department for Communities and Local Government Crown copyright,
Presented by: Rich Perry Marsh Risk Consulting
Flammable and Combustible Liquids Presented by: Rich Perry Marsh Risk Consulting What s the Big Deal? Flammable and combustible liquids are easily ignited Ignite with explosive force Burn readily and give
