Introduction to Microbiology, Sterile Technique and Micropipetting

Similar documents
Use of Micropipettes

Transferring a Broth Culture to Fresh Broth

Lab Exercise 3: Media, incubation, and aseptic technique

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

Transformation of the bacterium E. coli. using a gene for Green Fluorescent Protein

Transformation Kit BACTERIAL TRANSFORMATION: GREEN FLUORESCENT PROTEIN. Partnership for Biotechnology and Genomics Education

COMMON LABORATORY APPARATUS

Quantifying Bacterial Concentration using a Calibrated Growth Curve

Green Fluorescent Protein (GFP): Genetic Transformation, Synthesis and Purification of the Recombinant Protein

In order to be useful, a smear must have the following qualities:

DNA Electrophoresis Lesson Plan

Transformation Protocol

Microbiology Laboratory Safety and Basic Procedures Safety in a microbiology laboratory is important in the prevention of infection that might be

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Factors Affecting Enzyme Activity

Metabolism: Cellular Respiration, Fermentation and Photosynthesis

GENETIC TRANSFORMATION OF BACTERIA WITH THE GENE FOR GREEN FLUORESCENT PROTEIN (GFP)

Lab 5: DNA Fingerprinting

HYFLAM D3: Report of Scenarios 08/02/2012

BACTERIAL ENUMERATION

Laboratory 5: Properties of Enzymes

PAPER CHROMATOGRAPHY

Archived. Gloves should be changed frequently during the analysis.

Crime Scenes and Genes

Chemical reaction (slow): Enzyme-catalyzed reaction (much faster):

SAMPLE. Bacterial Transformation. Lab 8 BACKGROUND INFORMATION. Neo/SCI Student s Guide Name... Teacher/Section...

RAINBOW ELECTROPHORESIS 1 An Introduction to Gel Electrophoresis

How Does a Doctor Test for AIDS?

LAB 11 PLASMID DNA MINIPREP

Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity

Recovery of Elemental Copper from Copper (II) Nitrate

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 079 MOD: 1st Issue Page: 1 of 7

The Empirical Formula of a Compound

The Awesome Power of Yeast Genetics: Spontaneous and Induced Mutagenesis and Complementation Analysis using Saccharomyces cerevisiae.

Aseptic Technique. A GMP/GTP Training Module

Biology 3308: Microbiology Spring 2007 Lecture Syllabus

THE ACTIVITY OF LACTASE

Fig. 1. Background. Name: Class: Date:

Fuel Cell Characterization Lab

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML SINGLE-USE PEN

RESTRICTION ENZYME ANALYSIS OF DNA

Welcome to Implementing Inquirybased Microbial Project. Veronica Ardi, PhD

IDENTIFICATION OF POLYMERS 1998 by David A. Katz. All rights reserved

MICROSCOPY OF LIVING MICROBES

GROWING BACTERIA INTRODUCTION

Percentage of Water in Popcorn

Enzymes: Amylase Activity in Starch-degrading Soil Isolates

Blood Collection and Processing SOP

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

Fixed and Adjustable Spacing Electronic Pipettes

Experiment 5 Preparation of Cyclohexene

The Analytical Balance

EFFECT OF SALT ON CELL MEMBRANES

National Food Safety Standard Food microbiological examination: Aerobic plate count

1. The Determination of Boiling Point

Catalytic Activity of Enzymes

BUGS" THAT PRODUCE DRUGS TO KILL "BUGS Microbes Produce Antibiotics

Conservation of Momentum Greg Kifer

Objectives: Vocabulary:

The Determination of an Equilibrium Constant

Assessing safety in science experiments

Bydureon 2 mg powder and solvent for prolonged-release suspension for injection in pre-filled pen How to use Bydureon pre-filled pen

Sample Collection Procedures for Insulating Fluid Samples

LAB 16 Rapid Colony Transformation of E. coli with Plasmid DNA

Laboratory Biosafty In Molecular Biology and its levels

Amazing DNA facts. Hands-on DNA: A Question of Taste Amazing facts and quiz questions

Microscopy and Cellular Morphology

The E. coli Insulin Factory

Partner: Jack 17 November Determination of the Molar Mass of Volatile Liquids

Cloning GFP into Mammalian cells

Instructions for Use. Components of the GENOTROPIN PEN 12

Remember the best arguments are based on the strongest evidence and can explain why opposing arguments are incorrect.

Paper Chromatography: Separation and Identification of Five Metal Cations

Cell Biology Prokaryotic and eukaryotic cells

TransformAid Bacterial Transformation Kit

A Fishy Tale. Observing the Circulatory System of a Goldfish with a Compound Light Microscope

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

CLONING IN ESCHERICHIA COLI

6 H2O + 6 CO 2 (g) + energy

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Laboratory Biosafety Plan Template. For Biosafety Level 1 and 2

Determining Equivalent Weight by Copper Electrolysis

Biology for Science Majors

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

Hazardous Waste Procedures

Thin Layer and Column Chromatography

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

Biosafety Level 2 (BSL-2) Safety Guidelines

THE UNIVERSITY OF NEWCASTLE- SCHOOL of BIOMEDICAL SCIENCES

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Determination of the Empirical Formula of Magnesium Oxide

Blood Sampling in Sheep AS-557-W

Decontamination and Waste Management

Agarose Gel Electrophoresis with Food Color- Teacher Guide

HUMULIN 70/30 KwikPen

Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS

Infectious Waste Management Plan

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

LAB 4. Cultivation of Bacteria INTRODUCTION

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Transcription:

Introduction to Microbiology, Sterile Technique and Micropipetting Background: Bacteria represent the most widely distributed and metabolically diverse group of organisms. Because bacteria are relatively simple organisms and are amenable to experimental manipulation, they have provided elegant systems for basic research. Similarly, yeast, which are unicellular eukaryotic organisms, are a good model system for the study of basic cellular processes of eukaryotic cells. Additionally, because a small culture of bacteria or yeast has millions of individual cells, the researcher can quickly screen for rare genetic mutations. Some of the ways that bacteria or yeast are used in research laboratories include the following: 1. simple biochemical models 2. hosts for recombinant DNA 3. as the actual object of study, for example bacterial pathogenesis 4. for biotechnology purposes, such as insulin production or control of oil spills Bacteria and yeast are typically grown on solid media (agar plates) or in liquid culture. Cells are deposited on a plate by streaking from a liquid culture, or by moving dividing cells from one plate to a new plate. The transfer of bacteria or yeast to a sterile substrate in this fashion is called inoculation. Single cells inoculated on a plate grow and divide, forming a mass of cells called a colony. All the bacteria or yeast in a colony are genetically identical, with the exception of rare spontaneous mutants. There are wide variations in growth rates for different strains and species of bacteria. Many strains can double the number of cells in a liquid culture in less than 3 minutes under optimal conditions. On solid media, a single bacterial cell will form a visible colony 1-24 hours after inoculation. Saccharomyces cerevisiae (Baker s yeast) is commonly used in research laboratories around the world, and it has a generation time of 2 hours when grown at 3 º C. STERILE TECHNIQUE: In many laboratory exercises, sterile technique (which will be demonstrated in lab) is absolutely necessary. Sterile technique is a method of careful lab manipulations that prevents foreign cells (from the air or from you) from getting into your plates and cultures and prevents the bacteria in your exercises from escaping into the environment. This requires common sense and a bit of practice. In general, the following manipulations should be used when working with bacterial or yeast cultures (or for preparing samples for PCR): 1. The key to successful sterile technique is to work quickly and efficiently. Before beginning, clear off and disinfect the lab bench with 7% ethanol and arrange the tubes, pipet tips, and culture media within easy reach. Locate the Bunsen burner in a central position on the lab bench to avoid reaching over the flame. The barrel of your micropipettors should be cleaned using 7% ethanol and a Kimwipe. 2. Many of the materials you will use, such as solutions, pipette tips and microcentrifuge tubes, are already sterilized. Be sure these items remain sterile by covering or closing them immediately after use (i.e., close pipette tip boxes, put lids back on jars of solutions, etc.). 1

3. Never touch anything sterile with your fingers or clothes, and avoid directly breathing onto sterile items. Be aware especially of pipette tips once they are on your micropipettor - if they contact you or the bench as you perform manipulations, they are no longer sterile! 4. Wire loops used for transfer of bacteria must be flamed until they are red hot before and after each manipulation. Let the loop cool before it actually contacts the cultures you are working with to insure that you do not kill the cells that you wish to transfer. Alternatively, sterile plastic loops may be used once (without flaming!) and then disposed of. 5. When working with agar plates, minimize the time that plates are left uncovered. Work with the plate close to the base of a lit Bunsen burner when removing the lid (see diagram on right). The rising heat creates a convection current, which prevents microorganisms in the air from dropping onto the open plate. 5. Any pipette tips or materials that are contaminated with bacteria should be placed in Bio-Hazard bags or in the disinfectant jars on the bench tops. HEAT 6. Wipe down the bench with disinfectant when finished. Re-clean the barrel of your micropipettors with 7% ethanol and a Kimwipe. Wash your hands. 2

Exercise 3: Use of Micropipettors (adapted from DNA Science pp. 325-327) Micropipettors are instruments used to accurately transfer small volumes (1 µl to 1 ml) of solution. Because of their accuracy, ease of use, and convenience in sterile techniques they are a practically universal lab tool. In this week s lab you will learn how to properly use this instrument. In the rack at your lab bench, you will find three micropipettors; each one is appropriate for a specific volume range. If you look at the dot on the plunger of each micropipettor you will see a number that represents the maximum volume, in microliters (µl), that can be transferred by that micropipettor. The minimum volume appropriate for each micropipettor is typically ten percent of the maximum. The dot on the plunger is also color-coded and generally matches the color of the disposable tips used with that micropipettor. The table below shows the volume range, expected accuracy, and the appropriate tips for the micropipettors that you will be using. Micropipettor Volume Range (µl) Accuracy Disposable Tip P1 1-1 ± 1. µl Blue P2 2-2 ± 1. µl Yellow P2 1-2 ±.5 µl Yellow 3

In most experiments, accuracy is important when transferring small volumes of liquid with a micropipettor. A researcher needs to be sure that he or she is transferring the volume desired with a reasonable degree of accuracy. The researcher can be confident of this provided two conditions are satisfied. First, the micropipettor has been calibrated and tested for accuracy (this is usually done on a yearly or semi-yearly basis). Second, the researcher must be using the micropipettor properly. Proper use of the Micropipettor Use the text below and the illustration on the previous page to become familiar with the parts of a micropipettor: Barrel - the working end of the micropipettor; a disposable tip is seated on the lower end of the barrel before each use Plunger - the plunger is pressed and released to withdraw and expel liquid Tip ejector button - is used to remove a tip from the barrel without direct handling of the disposable tip Digital volume setting - displays the volume the micropipettor is currently set to deliver Volume adjustment knob - is rotated to change the digital volume setting Part 1: Familiarization with the micropipettor Materials: set of micropipettors Pick up a P2 and set the digital volume setting for 5 µl (reading down, the setting should be 5 ). Push the plunger down and notice that at some point the plunger becomes more resistant and requires more effort to push further. This point is called the first stop. Notice that the plunger can be pushed well beyond the first stop until it reaches the second stop. Be sure you can feel the first stop point and notice how far the plunger travels before reaching this point. Reset the micropipettor to 2 µl ( 2 ). Again push the plunger to the first stop. You should notice now that the plunger travels further to reach the first stop than it did when the micropipettor was set for 5 µl. Examine the P2 and P1 setting windows and plunger tension at various volumes as well. The table below shows how the digital volume display looks for each micropipettor when it is set at its maximum volume. Micropipettor P1 P2 P2 Maximum Setting 1 2 2 4

To transfer solution using a micropipettor: 1. Set the digital volume setting to the desired volume by rotating the volume adjustment knob. Note: the digital volume setting should never be adjusted above the maximum volume specified for a particular micropipettor. Remember that the maximum volume is the largest volume shown on the plunger. 2. Seat a disposable tip on the micropipettor by firmly placing the end of the barrel into a tip. 3. Depress the plunger to the first stop and immerse the end of the tip into the solution to be transferred. SLOWLY release the pressure of your thumb on the plunger to SMOOTHLY draw the solution up into the tip. 4. To expel the solution, put the tip into the next tube (or just above a sheet of paper). Then depress the plunger ALL THE WAY TO THE SECOND STOP. 5. If expelling into a liquid solution, REMOVE the end of the tip from the solution BEFORE releasing the pressure on the plunger with your thumb. 6. You should generally use a new tip for each transfer (or whenever the tip becomes clogged, if you are repeat pipetting from the same, non-sterile solution). When you wish to eject the tip you are using, place the tip over the appropriate waste container (small plastic beaker) and press the tip ejector button. If the tip is difficult to eject it is likely that you are jamming the tips onto the micropipettor harder than necessary. Part 2: Transferring small volumes with a micropipettor Materials: Piece of blotting paper 2X Loading dye P2 and rack of yellow tips Obtain a 4 x 5 inch piece of blotting paper and a microcentrifuge tube containing 2X loading dye. Following the protocol above, use a P2 to spot the following volumes of dye directly onto the paper in a linear order: 1 µl, 3 µl, 5 µl, 7 µl, 1 µl, 15 µl, and 2 µl. Spot each volume twice to check your consistency. Compare the spots you made with those of the instructor. If the spots do not look like those of the instructor, try to determine the cause. 5

Part 3: Transferring large volumes with a micropipettor (adapted from DNA Science page 328) Materials: 2 x 1.5 ml microcentrifuge tubes Solutions I-IV P1 and rack of blue tips This exercise simulates parts of a bacterial transformation or plasmid preparation for which a 1-1 µl micropipettor is used. It is far easier to mismeasure when using a large-volume micropipettor. If the plunger is not released slowly, an air bubble may form or solution may be drawn into the piston. 1. Use a permanent marker to label two 1.5 ml reaction tubes E and F. 2. Use matrix below as a checklist while adding solutions to each reaction tube. Tube Solution 1 Solution II Solution III Solution IV E 1 µl 2 µl 15 µl 55 µl F 15 µl 25 µl 35 µl 25 µl 3. Set micropipettor to add appropriate volumes of Solutions I-IV to tubes E and F. Follow the same procedure as for small-volume pipettor. 4. A total of 1 µl of reactants was added to each tube. To check that your measurements were accurate, set the micropipettor to 1 µl and carefully withdraw solution from each tube. a. Is the tip just filled? or b. Is a small volume of fluid left in the tube? or c. After extracting all fluid, is an air space left in tip's end? (The air can be displaced and actual volume determined simply by rotating the volume adjustment to push the fluid to the very end of the tip. Then, read the volume directly.) 5. If the measurements were inaccurate, repeat the exercise to obtain a nearly perfect result. 6