Form Date DECKS AND SHEDS

Similar documents
Residential Decks. Planning and Development Services Department

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Residential Deck Safety, Construction, and Repair

Uncovered Decks & Porches

COMMONLY USED RESIDENTIAL BUILDING CODES

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

POST AND FRAME STRUCTURES (Pole Barns)

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings.


RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

Typical Deck Details

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

BUILDING PERMIT SPECIFICATIONS

TOWNSHIP OF TOMS RIVER ZONING OFFICE DECK CONSTRUCTION

Uniform Construction Code (UCC) Manufactured Homes. Modular Homes. Building Permit Application Package

Number of Sides Required to Have a Handrail

Timber Decks. Technical Note. March 2007

Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

STANDARD OPEN PATIO COVER

Patio Covers / Carports

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE. decking guard. rim joist joists

Basic Requirements for Residential Plan Review _

Simplified Steel Stair Design for Commercial and Institutional Buildings

RESIDENTIAL WOOD DECKS

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Building Information Packet

Attached/Detached Patio Cover/Carport

The Homeowner s Building Application Checklist for Constructing a Residential Sundeck

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

Certification: Building Plans Examiner. Exam ID: B3

Sample Drawing Package for One and Two Family Dwelling Applications

Mobile Home Pre-Inspection Checklist

Building Department John Fiedler Construction Official Ext SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev

2015 UCC Residential Code Update

Chapter 3 Pre-Installation, Foundations and Piers

The replacement or modification of existing windows shall comply with the following requirements:

RESIDENTIAL BUILDING PERMITS

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Charter Township of Shelby Harry Reese Building Director

CITY OF TORONTO. BY-LAW No

Single Family Residential Building Permit Questions & Answers

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

ATI Evaluation Service A Division of Architectural Testing Certification Services

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Chapter 6 ROOF-CEILING SYSTEMS

Residential Plan Routing Information

Pennsylvania Uniform Construction Code Homeowner s Guide

Uniform With Exceptions

ESR-1190 Reissued December 1, 2009 This report is subject to re-examination in two years.

2880 International Circle Colorado Springs, CO Telephone Executive Summary Pikes Peak Regional Building Code Revisions

Formwork for Concrete

TYPICAL PATIO COVERS 111

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

DECKING INSTALLATION, CARE & MAINTENANCE INSTRUCTIONS MOISTURESHIELD.COM limited lifetime warranty

Wood Projects Outdoors. Post Hole Specifications. Deck Span Tables. Eakes.com

FINISHED BASEMENT SUBMITTAL GUIDE

TEST REPORT. Rendered to: INTEX MILLWORK SOLUTIONS, LLC. For: Rigid Cellular PVC Guardrail System Hampton RS40

Exterior Elevated Elements Inspection Guidelines

COMMONLY USED RESIDENTIAL BUILDING CODES

A Guide to Detached Residential Garages and Residential Workshops (based on 2006 BCBC)

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

St. Louis County Department of Public Works Division of Code Enforcement. When is a Building Permit required for Residential Projects?

A HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS

Fixed Access Ladders. Table of Contents. 1. Legislative Requirements

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

2014 FLORIDA BUILDING CODE

Estimated Cost of Repair

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Building Code Clarifications - 7. Fire Resistance

Residential Building Permit Process

Residential Foundations and Basements

Physical Address/Intersection: Name of Project: Within a NFIP 100/500yr Floodzone:

Residential Building Permits

CHAPTER 14. STURTEVANT UNIFORM BUILDING CODE (Rep. & recr. #099-08) GENERAL BUILDING INSPECTOR AND PERMITS GARAGES AND ACCESSORY BUILDINGS DECKS

OPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST

STAIRWAY Building code information for one- or twofamily dwellings and townhomes.

INFORMATION BULLETIN NO.

H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh

GENERAL BUILDING PERMIT INFORMATION FOR: RESIDENTIAL ALTERATIONS & ADDITIONS

Mason County Building Department

Introduction...COMB-2 Design Considerations and Examples...COMB-3

PARK COUNTY BUILDING PERMIT GUIDE PO Box 517 Fairplay, CO Fax: Inspections:

SECTION GUARDRAILS

Featuring TJ Rim Board and TimberStrand LSL

TJi 110 TJi 210 TJi 230 TJi 360 TJi. 560 JoiSTS. NEW! now featuring 18" and 20" TJi joists

INFORMATION BULLETIN NO.

MANUFACTURED HOUSING USED AS DWELLINGS

Walking and Working Surface Checklist:

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

The City of Basehor, Kansas

FINAL FAILURE INVESTIGATION WESTCHESTER NORTH LAGOON BRIDGE. Anchorage, Alaska

Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings

Transcription:

DECKS AND SHEDS 1. Is a permit required? A residential storage building needs a zoning permit, regardless of size. If the shed is greater than 500 square feet and accessory to a detached single family dwelling, or greater than 200 square feet and accessory to a two family dwelling or townhouse (measured by the building s footprint), in addition to zoning approval it will also require building department review of construction plans and approval with inspections. For all concrete patios and decks, a zoning permit is required. If the concrete patio will require footings or the deck is thirty (30) inches or more above grade (measured horizontally 36 from any point along the edge of the deck) a building permit is required. 2. What are the setbacks for a deck or shed? The setback requirements for many uses will vary with the zoning district in which the use is located. Please contact the Zoning Officer to determine which zoning district in which the use is located and the setback requirement appropriate for the use. 3. If a homeowner wants to attach a shed to the rear of their home, would it meet the same accessory setbacks as a free-standing one? An accessory building that is attached to the primary building shall be considered as an integral part of said primary building and not as an accessory building. It shall follow the primary use setback criteria accordingly. 4. Who do I contact if I have a question? Carl Jeff Wilson Residential Inspector (610)398-0401, Ext. 238 Keith Zehner Zoning Officer (610)398-0401, Ext. 239 Diane Folland Permits Office (610)398-0401, Ext. 240 Gail Danner Inspections Clerk (610)398-0401, Ext. 241 Page 1 of 9

RESIDENTIAL DECK SUBMITTAL GUIDE Pennsylvania Uniform Construction Code (UCC) referencing the 2009 International Residential Code as adopted by South Whitehall Township Ordinance 797, June 16, 2004 PERMIT REQUIREMENTS An owner or authorized agent who intends to construct, enlarge, alter, repair, move or demolish or change the use or occupancy of a residential building regulated by the Uniform Construction Code shall first apply to the building code official and obtain the required permit. Section 403.62 of the Uniform Construction Code as adopted by South Whitehall Township Ordinance 797. PERMIT APPLICATION A ZONING PERMIT is required for a deck and/or patio located less than 30 above finished grade. A BUILDING PERMIT is required if the walking surface of the deck is 30 or more above finished grade (measured 36 horizontally from any point of edge of deck). Complete a Building/Zoning Permit Application and submit it along with a site plan. BUILDING PERMIT submittals require plans/specifications for the proposed deck project. It is necessary to fill out all applicable areas of the permit application including the signature of the permit applicant, brief description of the project, cost of the proposed project and a Pennsylvania One Call serial number. A PA One Call serial number can be obtained by calling 1-800-242-1776. South Whitehall Township is required to include a PA One Call serial number on all permit applications where the project involves digging. Our staff will assist applicants with questions regarding the permit application at time of submittal. PERMIT FEE SCHEDULE WORKSHEET The permit fee for a deck requiring a zoning permit is $40.00, due at permit application. Permit fees for a residential deck requiring a building permit are based on the value of the deck. The fee is $10 for every $1,000 of value with a minimum fee of $100.00. For example, a deck costing $5,000 requires a permit fee of $100 (the minimum), a deck costing $10,000 requires a permit fee of $100, and a deck costing $15,000 requires a permit fee of $150. One hundred dollars is due at permit application and the balance is due upon permit issuance. PERMIT FEES ARE DUE BY CASH OR CHECK AT TIME OF APPLICATION. Page 2 of 9

PLAN REQUIREMENTS Submit two (2) copies of a site plan (separate from the construction documents) for projects requiring a zoning or building permit. Submit (2) copies of a deck framing plan, two (2) copies of a deck cross section and (2) copies of stairway/guardrail/handrail details (if applicable) for those projects requiring a building permit. At time of permit issuance, the permit applicant will receive an approved set of construction plans and an approved site plan along with the building permit and permit amendments. GENERAL DECK CONSTRUCTION NOTES Lumber shall be southern pine, grade #2 or better and shall be pressure treated ACQ or CA-B. Framing hardware and fasteners shall be hot-dipped galvanized or stainless steel. Decks shall not be attached to house overhangs, cantilevered bay windows, veneers, exterior finishes, or chimneys without the approval of a Pennsylvania registered architect or professional engineer. Inspections for decks include footing (prior to pouring concrete), framing and final. Framing and final inspections may be combined if the deck is elevated a minimum of 36 above grade. Electrical work performed in conjunction with deck projects is subject to the applicable provisions of the electrical code. Electrical work is subject to field inspection at the rough and final stages. Decks shall not be used or occupied until all final inspection approvals are obtained. PLAN SPECIFICATIONS Draw to scale or include dimensions on plans Cross Section Footings: Identify the footing depth below grade and footing dimensions. Footings shall bear on solid ground and be dug to a depth not less than the frost line depth of 36. No less than 12 of concrete is to be placed under all support posts, the bottom of which is 36 below grade. Support Posts: Identify the size of support posts and the elevation of the deck above grade. Post-to Beam Attachment: Identify the location and size of beams and identify the method of attachment between the support posts and beams. Post to beam connections require (2) ½ diameter hot-dipped galvanized or stainless steel thru-bolts with washers. Single ½ diameter bolts are permitted for 2 x 6 beams. IRC R502.9 Floor Framing: Identify the floor joist type, size and span and on center spacing. Floor Overhangs: Cantilevers of up to 3 are permitted with a backspan to cantilever ratio of 2:1. For example, a 3 cantilever requires a minimum 6 joist back span. Connections capable of resisting the uplift forces at the backspan support shall be provided. A full depth rim joist shall be provided at the cantilevered ends of the joists. IRC R502.2.1 Guardrail System: Identify guard systems. Provide attachment methods for securing guard posts to deck structure. Guards shall be designed to withstand a 200 lb. load applied to the top rail at any point and in any direction. IRC R312.1 & R312.2 Page 3 of 9

Page 4 of 9

Stacked washers are optional Page 5 of 9

Stairway Specifications Stair Width: Provide the proposed width of the stairway. Stairways shall not be less than 36 in clear width. Handrails may project into the clear width by not more than 4 ½ on either side of the stairway. Clear width at and blow the handrail height, shall not be less than 31.5 where a handrail is installed on one side and 27 where handrails are provided on both sides. IRC R311.5.1 Stair Treads and Risers: Provide the proposed stairway riser heights and tread depths. Stairway riser height are not to exceed 8 ¼ with no more than a 3/8 variation in riser height within a flight of stairs. The minimum tread depth is 9 measured from tread nosing to tread nosing. The greatest tread depth within any flight of stairs may not exceed the smallest by more than 3/8. IRC R311.5.3 per PA UCC 403.21(2) Risers may be open, but shall not allow the passage of a 4 diameter sphere on stairs with a total rise of 30 or more. Stair Profile: A nosing not less than ¾ but not more than 1 ¼ shall be provided on stairways with solid risers. Stair nosings are not required with a tread depth of 10 or more. IRC R311.5.3.3 Stairway Illumination: Exterior stairs shall be provided with a means to illuminate the stairs, including the landings and treads. Exterior stairs shall be provided with an artificial light source located in the immediate vicinity of the top landing of the stairway. The illumination of exterior stairways shall be controlled from inside the dwelling. IRC R303.6, R303.6.1 Guardrails: Provide an elevation detail of the proposed guard system(s). Guards along elevated deck surfaces shall be no less than 36 in height with openings not to exceed 4. Guards along stairways shall be not less than 34 measured vertically from the stair nosings with openings not to exceed 4 3/8. IRC R312.1, R312.2 Page 6 of 9

Handrails: Provide a cross sectional detail of required graspable handrail. Handrails having a minimum and maximum height of 34 and 38 respectively, measured vertically from the nosing of the treads, shall be provided on at least one side of the stairways of four or more risers. Handrails shall be continuous the full length of the stairs. Handrails shall be graspable and shall be constructed of decay-resistant and/or corrosion resistant material. Circular handrails shall be between 1 ¼ 2 in diameter. Non-circular handrails with a perimeter dimension greater than 6 ¼ shall provide a graspable finger recess area on both sides of the profile. The width of the handrail above the recess shall be between 1 ¼ 2 ¾. IRC R311.5.6 & R311.5.6.3 Page 7 of 9

Deck Framing Plan Ledger Board: Type, size and attachment details for ledger board. Ledger board attachment to the existing house shall be capable of supporting the new deck. Details are to include the existing house construction that will support the ledger, type of flashing, type/size of ledger board, type/size/spacing of ledger anchors. IRC R502.2.2.1 Table Flashing: Remove exterior finishes prior to installing the ledger board. Install flashing where ledgers are secured to existing construction. Flashing is required at ledger connections of wood framed walls. Approved flashing materials include galvanized steel, UV resistant plastics/rubber, stainless steel and copper (attached using copper nails). IRC R703.8 Beams: Identify the location, size, type, number of plies, and span of structural beams. Secure built-up wood beams with no less than two rows of 10d galvanized or stainless steel nails in a staggered pattern 16 on center. 3 rows of 10d nails are needed for beams 10 or deeper. For beams secured to opposite sides of posts, install solid full depth 2x blocking at 4 0 on center. MINIMUM BEAM SIZES FOR SINGLE SPAN JOIST LOADS* Joist Span Minimum Beam Size* 0 6 8 (2) 2 x 6 6 8 11 2 (2) 2 x 8 11 2 15 9 (2) 2 x 10 16 0 18 9 (2) 2 x 12 *Beam sizes are based on support post spacing of 8 with span floor joists extending from ledger board. This table is not applicable for beams carrying floor joist loads from two directions. This table is not applicable for decks supporting hot tubs or other concentrated loads. IRC R501.2 Floor Joists: Identify the size, type, on center spacing and direction of span of the floor joists. MAXIMUM JOIST SPANS ( #2 Pressure Treated Southern Yellow Pine) Joist Size Joist Spacing, On Center Joist Span (no overhang) 2 x 6 16 9 9 2 x 6 24 8 6 2 x 8 16 12 10 2 x 8 24 11 0 2 x 10 16 16 1 2 x 10 24 13 1 2 x 12 16 18 10 2 x 12 24 15 5 2009 IRC Table R502.3.1(2) Spans are based on 40 PSF live load, 10 PSF dead load, southern pine #2, deflection of 1/360. This table is not applicable for decks supporting hot tubs or other concentrated loads. Page 8 of 9

Floor Deck: Identify the type of decking to be installed. Typical materials include 2 x 6 or 5/4 (five-quarter) lumber. Composite decking is permitted if installed per manufacturer s product specifications. Support Posts: Identify the location of support posts on the framing plan. 4 x 4 posts are permitted for decks up to 36 above grade. Decks above 36 are to be supported on 6 x 6 posts. Post to beam connections require (2) ½ diameter hot-dipped galvanized or stainless steel thru-bolts with washers. Single ½ diameter bolts are permitted for 2 x 6 beams. IRC R502.9 Footings: Illustrate footing locations on the framing plan. IRC R401.2 Stairways: Identify stairway(s) and/or deck elevation changes on the framing plan. IRC R311.5 Page 9 of 9