FiveEasy TM. Simplify Your Lab Quality Measurement for the Budget Minded. FiveEasy TM Bench Instruments FiveEasy Plus TM. FiveEasy

Similar documents
Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

Operating Instructions

Compact ph Measuring Instruments

SevenGo Duo. Quick and Reliable Measurements for Results at your Fingertips. SevenGo Duo Portables SevenGo Duo SevenGo Duo pro

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters

Operating Instructions Bedienungsanleitung Mode d'emploi Instrucciones de manejo Istruzioni d'uso

Conductivity and TDS Meters

Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

ph Measurement and Control

Milwaukee USER MANUAL

HND-R. Hand-held ph, Redox and Temperature Measuring Units

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Ion-selective Measurements

USEPA Electrode Method Method 8156

Portable Hardness Tester

UltraBasic Benchtop ph Meter Operation Manual

ph and Acidity in Wine and Fruit Juice

Hand-held thermometer Model CTH7000

SenTix 950 SenTix 980

Unmatched Metal Hardness Testing

User Manual. Thermo Scientific Orion VERSA STAR

ExStik TM ph Waterproof Meters

Density/Specific Gravity/ Concentration Meter DMA 500

1.44 kw Programmable DC Power Supplies XLN Series

OT 40L / 90L. Laboratory Steam Sterilizers

Stainless Steel Dissolved Oxygen Electrodes

Density- & Refractometers

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Mitos P-Pump. product datasheet

Melting Point Apparatus

ph 200 ph-/redox-/temperature Meter Operating instructions

Test equipment for temperature and its reduction

JUMO tecline HD ph and JUMO tecline HD Rd

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

Compact Water Quality Meter B-700 series

Physical Specifications (Custom design available.)

Classic Balances NewClassic ML Precise results Compact and portable Affordable for all budgets

REDOX AND REFERENCE ELECTRODE USER MANUAL

Portable digital microprocessor thermometers with interchangeable probes

DISSOLVED OXYGEN METER Model : DO-5509

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Multifunction HVAC and IAQ Meter

Digital inductive conductivity transmitter

X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS

Product Information Sheet UH36 Hi Pot Tester

Highly efficient flue gas analyzer

General Purpose ph/orp Sensors

Laboratory Control Software

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG

Material test chamber with mechanical convection

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Product Information. QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications

SWISS MADE. Series 320 XB MASTER. Analytical. Precision

DISSOLVED OXYGEN PROBE

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS

K-Type Thermocouple Sensor User s Guide

High-Precision Platforms

Galvanic Parts Per Million Dissolved Oxygen Systems

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Fixed and Adjustable Spacing Electronic Pipettes

Others ph conductivity measurement module ph and conductivity measurement in 96 deep well plates

Hand-held marking system FlyMarker mini

LabX titration Software

Model 4510 Conductivity/TDS Meter Operating Manual

TR Series Surface Roughness Tester for workshop and laboratory

SPY-BATT Battery Tutor Device Installation Manual Rev /04/2016

ph, redox and I.S.E. electrodes

Measurement by Ion Selective Electrodes

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Conductivity measurements are used for applications such as in the production of ultrapure water or determining the salinity of sea water.

Agilent 4339B/4349B High Resistance Meters

CyberScan 6000 Series. Bench Meters. ph ph FET ORP Ion Conductivity TDS Salinity Resistivity Dissolved Oxygen BOD (OUR,SOUR)

NEW. EVEN MORE data acquisition and test stand automation

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Current Monitoring Kit QUICK START GUIDE

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Cond-IS RF Conducted Immunity System

Current Monitoring Kit

USB-500/600 Series Low-Cost Data Loggers and Accessories

RTD Temperature Probe for the Food/Pharmaceutical Industry

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

BOS 73K... BOS 74K...

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

Color Measurement Solutions for the Food Industry. Trusted by Over 70% of the Top 100 Global Food and Drink Companies*

4-Channel Thermometer / Datalogger

73 Series Spectrophotometers

Vacuum drying oven for non-flammable solvents

TurbiDirect TurbiCheck TurbiCheck WL

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Transcription:

FiveEasy TM FiveEasy TM Bench Instruments FiveEasy Plus TM FiveEasy TM ph mv / ORP TDS Salinity Simplify Your Lab Quality Measurement for the Budget Minded

Introducing the FiveEasy TM Series Keeping ph Measurements Simple Intuitive Solutions for Your Lab Time is an ever more valuable asset. Thanks to the Five's intuitive operation, sleek design and simple data export functions, you can maximize your time spent measuring instead of dealing with complex system and measurement setups. Ideally suited for applications in the laboratory, the new FiveEasy and FiveEasy Plus benchtop instruments provide high quality ph/mv or conductivity measurements with the simple click of a button. Compact in design, and featuring various data export opportunities, the FiveEasy series instruments are the perfect companion to get reliable measurement data, all at a reasonable price. Intuitive Operation Measurement Made Easy Compact Design Save Space Fast Connectivity Simple and Secure Data Transfer Featuring a large, well-structured display for easy viewing, the instruments' intuitive button arrangement and simple menu ensure measurements can be performed in just a few clicks. Thanks to its compact design, little bench space is needed for the Five series meters. The sensor holder can be easily removed and stored on the side of the meter after use. The FiveEasy Plus series meters allows data to be exported either directly to a printer or a PC for further processing using its RS232 or USB ports. 2

Food & Beverage Environment Agriculture Industry Academia The New FiveEasy TM Series ph and conductivity measurements made easy, wherever your lab is situated. 3

Technical Specifications A Look Inside Specified for Your Measurements The well-priced ph/mv and conductivity FiveEasy and FiveEasy Plus benchtop meters are the perfect choice for a wide range of laboratory applications. Technical Specifications Specifications General Measurement Data Storage Connectors General Measuring range Resolution Error limits Temperature compensation Automatic and manual endpoint recording Acoustic endpoint signal Visual endpoint signal Calibration Memory size FiveEasy Plus ph FP20-2.00 16.00 ph -2000 2000 mv -5 105 C (23 221 F) FiveEasy ph F20 0.00 14.00 ph 0 100 C (32 212 F) 0.01/0.1 ph 0.01 ph 1 mv 0.1 C 0.1 C ± 0.01 ph ± 1 mv FiveEasy Plus FP30 0.01 µs/cm 500 ms/cm (conductivity) 0.01 mg/l 300 g/l (TDS) 0.00 42 psu (salinity) - -5 105 C (23 221 F) Automatic range ± 0.5% of the measured value FiveEasy F30 0.01 µs/cm 200 ms/cm (conductivity) 0.01 mg/l 200 g/l (TDS) 0 100 C (32 212 F) ± 0.3 C ± 0.5 C ± 0.3 C ± 0.5 C ATC and MTC Linear: 0.00 %/ C 10.00 %/ C, reference temperature: 20 and 25 C Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes max. 5 point max. 3 point 1 point 1 point Linear/segmented Linear - - 4 predefined buffer groups 200 measurements, current calibration Current calibration 3 predefined standards, manual cell constant input 200 measurements, current calibration Sensor inputs BNC, Cinch BNC, Cinch Mini-DIN Mini-DIN RS232 interface Yes - Yes - USB interface Yes - Yes - Reference input Yes - - - Analog output - Yes - - Power supply Display Housing Size / Weight Input: 100 240 V / 50 60 Hz Output: 12 V DC 4.3" segmented LCD ABS 227 x 147 x 70 mm / 0.63 kg 3 predefined standards Current calibration 4

Food & Beverage Environment Agriculture Industry Academia Optimally designed for work on bench surfaces in a wide range of workplaces, including laboratories in academia. 5

The FiveEasy Portfolio A Complete Overview Solutions Suited for Your Needs Different combinations of FiveEasy and FiveEasy Plus meters, sensors and accessories are available. These kits are ideally suited for specific applications and samples. Kits Overview and Order Information ph/mv, ORP Meter Kits Kits description Order Number Ideally suited for FiveEasy Plus FP20 ph/mv FiveEasy F20 ph/mv FiveEasy Plus FP30 FiveEasy F30 FP20-Meter FP20-Standard FP20-Bio FP20-Micro FP20-TRIS F20-Meter F20-Standard FP30-Meter FP30-Standard F30-Meter F30-Standard meter only Standard kit with LE438 sensor Kit with LE410 sensor Kit with LE422 sensor 30266627 30266628 30266629 30266940 Kit with LE420 sensor 30266941 Meter only Standard kit with LE438 sensor Meter only Standard kit with LE703 sensor Meter only Standard kit with LE703 sensor 30266658 30266626 30266944 30266945 30266942 30266943 Applications that require a specific sensor not included in a kit Wide range of general aqueous samples Fast results in aqueous samples such as acids, bases etc. Small samples in vials and test tubes Demanding, 'dirty' samples such as emulsions, oily samples, waste water, TRIS, etc. Applications that require a specific sensor not included in a kit Wide range of general aqueous samples Applications that require a specific sensor not included in a kit Aqueous samples with mid to high conductivity Applications that require a specific sensor not included in a kit Aqueous samples with mid to high conductivity Accessories for FiveEasy Plus / FiveEasy Description Order Number FiveEasy Plus / FiveEasy electrode arm (includes sensor holder and pole) 30239139 FiveEasy Plus / FiveEasy electrode arm extension for larger sample beakers 30239140 FiveEasy Plus / FiveEasy rubber cap (2 pieces for electrode arm opening on instrument) 51302952 FiveEasy Plus / FiveEasy side cover 30239146 6

Sensors & Applications Type Description Plug/Connection Order Number LE438 3-in-1 plastic electrode with integrated temperature sensor for field use, samples with fluctuating temperatures; low-maintenance BNC/Cinch 51340242 LE407 Robust plastic ph electrode with gel electrolyte, suitable for simple applications and easy samples such as water; low-maintenance BNC 51340330 LE408 LE409 LE410 LE420 LE422 Robust plastic ph electrode with liquid electrolyte, suitable for simple applications; refillable electrolyte Glass ph electrode with liquid electrolyte for simple and rapid measurements in the labo ratory, aqueous samples such as acids, bases etc.; refillable electrolyte 3-in-1 glass ph electrode with integrated temperature sensor and with liquid electrolyte for rapid measurements in the laboratory; for aqueous samples such as acids, bases etc.; refillable electrolyte Glass electrode with movable PTFE-sleeve junction for demanding, dirty samples such as waste water, emulsions (e.g. milk), oily samples; refillable electrolyte Micro ph electrode with gel electrolyte, suitable for small samples in vials and test tubes; low-maintenance; 4.3 mm diameter BNC 51340347 BNC 51340331 BNC/Cinch 51340348 BNC 51340332 BNC 30089747 LE427 BNC 51340333 The spear tip design makes it ideal for solid samples such as meat, fruit, cheese, soil and many more; low-maintenance LE427-S7* S7 51340334* LE703 Robust conductivity probe for medium to high conductivities (10 µs/cm 200 ms/cm) Mini-DIN 51340335 LE740 Robust conductivity probe from low to medium conductivities (0.01 µs/cm 500 µs/cm) Mini-DIN 51340336 LE501 Glass ORP electrode with platinum pin for lab use BNC 51340338 LE510 Robust plastic ORP electrode with platinum pin for field use, e.g. swimming pools BNC 51340339 NTC 30kOhm Separate temperature sensor Cinch 51300164 * No cable is included, a selection of cables is available for connection to various instruments, e.g. Red S7-BNC, 1.0 m (Order no. 59902392) for METTLER TOLEDO, Hanna etc. More cable information is available at www.mt.com/electrode-guide. For more information and documetns on the new FiveEasy (Plus) meters, kits, and accessories, visit: www.mt.com/fiveeasy 7

More Meters and Accessories FiveGo Portable meters with IP67 protection and data memory to measure ph, conductivity or dissolved oxygen: www.mt.com/fivego Buffers and Solutions Learn more about our portfolio of certified buffers and solutions: www.mt.com/buffersandmore SevenCompact Universal quality benchtop meters for reliable ph and conductivity measurements: www.mt.com/sevencompact www.mt.com/ph For more information Mettler-Toledo AG, Analytical CH-8603 Schwerzenbach, Switzerland Tel. +41 22 567 53 22 Fax +41 22 567 53 23 Subject to technical changes 11/2015 Mettler-Toledo AG, 30279225 GlobalMarCom Switzerland / RT