Magnetic card reader

Similar documents
HCR3.2/.. Chipcard reader HOTEL SOLUTION

Digital input modules

TX OPEN RS232/485 module

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Air damper actuators

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

PCS0100en Persy Control Services B.V. Netherlands

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

13 SERIES. Electronic step relays A

RRV934. Multi-controller. Synco living

Mureva Assembly surface mounted wiring devices

Inwall 4 Input / 4 Output Module

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Digital Keypad Use s Manual

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

OZW30. Central Unit SYNERGYR

Drayton Digistat +2RF/+3RF

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Product and Application Description

Cross-beam scanning system to detect slim objects. 100 mm in

Model 201 Wiegand Touchpad Reader Installation Guide

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

VAV compact controller KNX / PL-Link

Voltage Regulator SPAU 341 C. Product Guide

ZC-24DO CANopen I/O Module: 24 Digital Outputs

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Duct Humidity Transmitter

Wind Sensor W-RS485 with RS485 Interface

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

ACR120 Technical Specifications version 2.9 November 2005

Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

is then retained absolutely without interruption.

Product and functional description

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Processor. Installation Guide

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

StructureScan HD Module. Installation Guide ENGLISH

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Waveguide Access Point WGA631. Product Guide

Modular I/O System Analog and Digital Interface Modules

Manual. Simrad StructureScan LSS-1 Sonar Module. English

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

VAV compact controller KNX / PL-Link

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

INSTALLATION INSTRUCTIONS

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Redundancy Module QUINT-DIODE/40

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Switches and Indicators. Swisstac

Shunt lock function 3066

Quick Connect. quick - simple - efficient.

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Smoke exhaust systems

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

HMI display Installation Guide

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

8 by 8 dot matrix LED displays with Cascadable Serial driver B32CDM8 B48CDM8 B64CDM8 General Description

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

CO2 Alarm. Operation. Application

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Combi switchbox with integrated 3/2 way pilot valve

Rack mounted telephone- and leased line modem for industrial applications

How To Set Up A Modem (Marc) Model (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar

Circuit Board Sensor Products

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

GV- RK1352 Card Reader

Telephone- and leased line modem for industrial applications TD-36

How To Build A Hotel Solution System

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

User Manual. EtherUSB

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation

Transcription:

6 334 HOTEL SOLUTION Magnetic card reader HMR3.1/A Magnetic card reader for hotel room access control Reads access code from Track 2 of the card's magnetic strip Transfers access code to HRC3.. room controller Built-in illuminated display of messages from hotel room Messages indicated by LEDs behind imprinted symbols Membrane switch for doorbell feature Application The HMR3.1/A magnetic card reader is used in conjunction with the HRC3.. room controller. The magnetic card access code is on Track 2 of the magnetic strip. Guest and hotel-staff access codes are read by the HMR3.1/A magnetic card reader and transmitted to the HRC3.. room controller for access control. CM2N6334en 31.07.2008 Building Technologies

Functions The HMR3.1/A magnetic card reader communicates with the HRC3.. room controller via a serial port, performing the following functions: Reads access code from Track 2 of the card's magnetic strip Transfers the access code, after reading, to the HRC3.. room controller Activates the functions programmed in the HRC3.. room controller based on the access code concerned (guest code, hotel staff code, invalid code). Transfers the membrane switch signal for the optional doorbell feature Displays signals from the HRC3.. room controller with illuminated LEDs behind imprinted symbols Types HMR3.1/A Magnetic card reader Ordering When ordering, please specify the quantity, product name and type code: Example 30 Magnetic card readers HMR3.1/A Compatibility Please refer to the assortment overview, N6301. Mechanical design Basic design The HMR3.1/A magnetic card reader comprises the following: Component assembly (carrier, printed circuit board, four LEDs, membrane switch, magnetic card reader-unit and terminal block) Front-plate unit Operator panel The components are snap-mounted in the front-plate unit. The operator panel label has an adhesive strip on the back. After removal of the protective backing, this label can be affixed to the front plate. Display Depending on the standard application configured in the HRC3.. room controller, the following room states can be displayed: Do not disturb "Make up room" or "Room service" call "SOS" call "Guest present" indicator (for hotel staff only) Door open Door closed Access denied 2/6

Key to symbols The symbols are shown in white on the black background of the front plate. T1 V3 V5 V2 V6 Membrane switch for doorbell feature Yellow LED (room service) Yellow LED (do not disturb) Red LED (door closed) Green LED (door open) Engineering notes The magnetic card reader is designed for flush wall mounting in conjunction with baseframes and cover-frames from various manufacturers: SIEMENS-DELTA futura VIMAR idea Bticino Classic GEWISS Playbus AVE Systema 45 Up to four card readers can be connected to the same room bus. The address is set with 2 DIL switches on the back of the unit (see below). STOP Caution The maximum permitted current associated with the supply voltage from the HRC3.. room controller must not be exceeded (for further information, see data sheets N6313, N6314.) Mounting The HMR3.1/A magnetic card reader must be mounted outside the hotel room at the same height as the light switch. First press the card holder into the base-frame and then attach the adhesive label to the front plate. If the front-plate label is fitted first, it is then difficult to press the card holder into the base-frame. To remove the unit, it must be unscrewed from the wall together with the base frame. Ensure that there is enough spare cable in the mounting box to allow operation of the DIL switches on the PCB (for addressing). The device is designed for fixed installation in a dry, enclosed space. For installation in a 4-module mounting box, depth 70 mm Mount horizontally only, with the front plate vertical Do not install AC 230 V devices in the same mounting box Commissioning must be carried out by trained personnel only Do not open the unit Local safety and installation regulations must be observed 3/6

Commissioning If several devices are operated by the same room controller, an address must be set for each one. Only one device will operate with the factory-set default. Bus address Switch 1 Switch 2 0x38 off off 0x39 off on 0x3A on off 0x3B on on Note In the standard application with only one reader, the HMR3.1/A magnetic card reader should be programmed with Address 0x3B. Address 0x3B (both DIL switches ON) is the factory setting for the HMR3.1/A magnetic card reader. Technical data Power supply (from HRC3..) Working voltage (SELV) DC 9..15 V Current 25 ma max. Magnetic card reader Reading speed 10... 150cm/s Service life 500,000 read cycles Track Track 2, ISO 7810 Magnetic cards Format 86 x 54 x 0.76 mm LoCo magnetic strip Membrane switches Service life 100,000 switching operations Bus interface Type RS485 Transmission speed 4800 baud Bus voltage SELV DC 12 V Display Luminous intensity of LEDs: 1.8 mcd Reflective sensor Range 4mm Wavelength of light beam: 940 nm Environmental conditions Operating temperature: -10...50ºC Transport temperature: -30...70ºC Humidity: Max. 90%, non-condensing Air pressure during operation: Min. 700hPa (3000m above sea level) Air pressure during transportation: Min. 700hPa (10,000m above sea level) Standards Safety of IT equipment EN 60950 Electromagnetic compatibility Emitted interference in residential areas Interference immunity in industrial areas EN61000-6-3 EN61000-6-2 Housing protection to EN 60529 IP 20 (with mounting box) Protection class to EN 61 140 III conformity Meets the requirements of EMC Directive 89/336/EEC UL/CUL approval UL/CUL 916 Dimensions See also dimension diagrams 103mm x 52mm x 69mm Suitable for flush mounting in 4-module rectangular flush-mounting box or cavitywall Deep flush-mounting box required, e.g. Siemens5A-002-1 box Color Plastic components Black Front-plate label Pantone black 7U2Y Weight Excluding packaging 70 g With packaging 120 g 4/6

Connection diagrams Device connection Read head 5V GND DATA CK CP Address switch 5V RESET Microcontroller 5V 12V RS485 GND 12V UG UR UP Room bus UN Door close Door open Guest in room Do not disturbe Make up room Bell push Connection to the room bus Pin Signal 1 UP Data signal + 2 UN Data signal 3 UG System neutral (GND) 4 UR Supply voltage DC +12 V Room bus connection terminal (view of pins from above) Wiring diagram 1 2 3 4 S1 S1 Magnetic card reader HMR3.1/A 1 2 3 4 6334A01 N1 HRC3.. room controller X12 N1 STOP Caution Note the cross-over between pins 3 and 4. 5/6

Dimensions Dimensions in mm ca. 70 1,5 65 51 67 100 102,5 9,5 Optional: SIEMENS S.p.A. 5TG9015, 5TG9021-1_*_ 80,5 Optional: SIEMENS S.p.A. 5VA002-1 108 140,5 3 6234M01 6/6 2005-2008 Siemens Switzerland Ltd. Subject to change