B. Submit an installer s certification or recommendation letter from the spray polyurethane foam material manufacturer.

Similar documents
Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

An American Institute of Architects (AIA) Continuing Education Program Credit for this course is 1 AIA/CES HSW Learning Unit

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Fiberglas, Exterior Wall Thermal Insulation

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

Avoiding Air Barrier Pitfalls

Colorado State University. Durrell Center Roof Repair

FIRESTOPPING & SMOKE SEALS

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

Introduction...COMB-2 Design Considerations and Examples...COMB-3

EcoTouch Insulation with PureFiber Technology

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS

Insulating Basements: Part 3 Basement Wall Systems

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

K2 STONE NATURAL VENEER

Architectural Concrete Masonry

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

2.18 INTERIOR & EXTERIOR FINISHES VAPOR & AIR BARRIERS

GigaCrete Specification PlasterMax

Manufactured Stone Veneer Installation Instructions

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Backstop NT. Backstop NT Specifications DS180. A High Performance, Polymer-Based, Noncementitious Water-Resistive Membrane and Air Barrier

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Underwriters Laboratories Testing Information

Tremco Fire Protection Systems Group Technical Bulletin

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

ITEM THERMOPLASTIC MEMBRANE ROOFING

Product Guide Specification

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Water Damage & Repair

SWD URETHANE COATED FOAM ROOFING SYSTEM MASTER ROOF SPECIFICATION SECTION

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

COMMERCIAL BUILDING APPLICATIONS

Sun Windows General Information Sun New Construction Window Installation Instructions

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

The Case for Cross Laminated Timber: Part 2

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

GreenGuard Housewrap Installation Guide

Standard Method for Sampling and Analysis of. of Chlorine Containing Bleaches. Soap Products

UPDATE October 8, 2012 Chicago Roofing Contractors Association CHICAGOLAND S ROOFING, INSULATION, AIR-BARRIER REQUIREMENTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CERTAINTEED CORPORATION

Built to Last. Built for Beauty. Good. Solid. Logix. TM

SCENIC VIEW SV 10 SECTION SOLAR CONTROL FILMS

Springlok Flashing System

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

The Prefab Package. Modular EIFS construction offers benefits to today s busy jobsites. Building Envelope. Roland Serino, P.E., of Dryvit Systems Inc.

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902

Division 9. SignaFlor Pad and Pour Flooring System

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER

SECTION METAL WALL PANELS

LAYING BLOCK AND BRICK

State of Connecticut Department of Public Health RADON PROGRAM

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Fire Resistance of Brick Masonry

R-Value and Densities Chart

Dryvit Finish System For Exterior Soffits

Asphalt Shingle Application Requirements

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Guide for SOLID CONCRETE BLOCK SEALS

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Preventing Ice Dams on Roofs

TEST REPORT. Report No.: A Rendered to: BAMCO INC. Middlesex, New Jersey. PRODUCT TYPE: Wall Cladding System SERIES/MODEL: Dry Concept

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Mold Preventing I nterior System

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

Composite Panel Firewall Systems

Barewood Octagon and Elongated Windows Installation Instructions

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

SECTION THERMOPLASTIC MEMBRANE ROOFING

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

STONE PANELS, INC. 100 South Royal Lane Coppell, TX Phone: (469) * Toll Free: (800) Fax: (469)

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

3 Masonry and Manufactured Stone (Interior and Exterior)

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

Building Owners Guide to a Duro-Last System!

ALPHA 15-Year Permathane II FR w/granules

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

SECTION ACOUSTICAL WALL TREATMENT. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Transcription:

SECTION 07200 SPRAY POLYURETHANE FOAM INSULATION PART 1 GENERAL 1.01 RELATED DOCUMENTS A. The Drawings and provisions of the General Conditions, Supplementary Conditions, and the Sections included under Division 1, General Requirements, are included as a part of this Section as though bound herein. 1.02 SUMMARY A. Provide labor, materials, and equipment necessary to spray-apply polyurethane foam (SPF) insulation, air seal and water repellent treatment for cavity wall throughout the Project. 1.03 SUBMITTALS A. Submit manufacturer s technical product data of material intended for use, including specifications, installation instructions, material safety data sheets, and general recommendations. B. Submit an installer s certification or recommendation letter from the spray polyurethane foam material manufacturer. 1.04 PROJECT CONDITIONS A. Substrate: Proceed with spray polyurethane foam application only after substrate construction, penetration work, and related welding and other hot work has been completed. Verify that mortar has cured sufficiently and masonry substrate is dry by checking surface for moisture with Moisture Detection Paper (MDP) strips. B. Weather Limitations: Do not install spray polyurethane foam during precipitation or when precipitation is imminent. Do not install when the ambient temperature is less than 50 F without specific authorization of the manufacturer. Do not install when the ambient humidity exceeds the manufacturer s limits. 1.05 QUALITY ASSURANCE A. Installer shall be a firm which has had at least 3 years of successful experience in application of spray polyurethane foam. Installer must be an NCFI Gold Star SM certified insulation contractor or have SPF manufacturer s certification for the application. B. Installer will provide equipment to spray-apply polyurethane foam including, but not limited to, high pressure plural component proportioning pump, heated hoses of suitable length, spray gun, drum pumps or other material feeding system, and other ancillary equipment necessary for the Project. 040208 SPRAY POLYURETHANE FOAM INSULATION 07200-1

C. Test application: Prior to start of work, installer will spray-apply an area of approximately 100 square feet at the specified thickness as directed by Architect for the purpose of demonstrating visual and physical effects. Proceed with work only after Architect s acceptance of test application. PART 2 PRODUCTS 2.01 MATERIALS A. Spray polyurethane foam shall be InsulBloc manufactured by NCFI Polyurethanes, Mount Airy, NC. Spray polyurethane foam shall have the following physical properties: Property Value Units Test Method Core Density 1.9-2.2 lb/ft 3 ASTM D-1622 Water Vapor Transmission 1.0 @ 2" thick perms ASTM E-96 R-Value 6.4 (min) @ 1" thick hr ft 2 o F/Btu ASTM C-518 Compressive Strength 15 (min) psi ASTM D-1621 Flame Spread <25 ASTM E-84 Smoke Developed <450 ASTM E-84 Air Leakage 0 @ 1.57 psf cfm/ft 2 ASTM E-283 Tensile Strength 15 psi ASTM D-1623 Hydrostatic Pressure Resistance No Failure @ 55 cm Head Pressure AATCC 127 B. Products of other manufacturers will be considered for acceptance provided they equal or exceed the material requirements and functional qualities of the specified product. Requests for Architect s approval and complete technical data for evaluation must be received at least 10 days prior to bid due date. Additional approved manufacturers will be issued by Addendum. 2.02 MISCELLANEOUS MATERIALS A. Foam Repair Kit: Handi-Foam two part kits from Fomo Products and Touch n Seal 2 component systems from Convenience Products, or other equivalent kits. B. Mineral Wool: Delta Safing Mineral Wool Board, 4 lb./cu. ft. density, manufactured by Rock Wool Manufacturing Co., Leeds, AL. C. Moisture Detection Paper (MDP) Strips: MDP Strips manufactured by NCFI Polyurethanes, Mount Airy, NC. PART 3 EXECUTION 040208 SPRAY POLYURETHANE FOAM INSULATION 07200-2

3.01 PREPARATION A. Clean masonry substrate of substances which would interfere with the adhesion of the spray polyurethane foam. B. Fill voids between masonry and structural steel with mineral wool. C. Mask adjacent materials as needed to prevent overspray. D. Test substrate with Moisture Detection Paper (MDP) strips to affirm that the substrate is dry. 3.02 APPLICATION A. Apply spray polyurethane foam directly to the masonry block in accordance to the manufacturer s installation instructions. All surfaces to be sprayed with foam must be free of all forms of moisture and ice. Surfaces can be checked with NCFI's MDP (Moisture Detection Paper) strips prior to and during foam application. B. Do not apply spray polyurethane foam during inclement weather or when ambient temperature and humidity are outside the ranges prescribed by the manufacturer. C. Apply the spray polyurethane foam to an average thickness of inches with a minimum thickness of inches. Apply the full thickness in any given area the same day. Note to Specifier: Base average thickness on the R-value requirements (1" R-6.5). Specify minimum thickness as average thickness less 1/4 inch per inch of average thickness as in table below. Table 1: Typical R-Values at Specified Thicknesses R-Value of Insulation Average Thickness (inches) Minimum Thickness (inches) 6.4 1 3/4 9.6 1 1/2 1 1/4 13 2 1 1/2 16 2 1/2 2 D. Shield the spray polyurethane foam from interior exposure with an approved thermal barrier. E. Remove overspray from adjacent surfaces. F. If the foam is applied at a thickness in excess of the specified depth and does not interfere with the installation of the brick and does not block the drainage plane, it can be left in place. If these conditions are not met, the foam should be trimmed or sanded back to a depth that alleviates these problems. The planing of the foam thickness can be done with a hand saw to trim off slices when 040208 SPRAY POLYURETHANE FOAM INSULATION 07200-3

the thickness excess is the result of bulges or lumps. If large areas need to be planed, a circular sander or wire wheel grinder may be used. Removing the foam surface skin layer does not diminish the air blockage, dampproofing ability or R value per inch of the foam membrane. Once the foam layer is planed down to a satisfactory depth, no additional treatment is required before the brick veneer is installed. In some cases, such as small areas around penetrations, it may be easier to completely scrape the foam off of the block surface and re-spray the foam. Patching the foam in this manner is acceptable. 3.03 REPAIR TECHNIQUES A. Where damage occurs which violates the spray foam s air seal and moisture seal, repair as needed using the specified spray polyurethane material or the specified foam repair kit material. END OF SECTION 07200 040208 SPRAY POLYURETHANE FOAM INSULATION 07200-4

(Typical) Anchors (Typical) Face Brick InsulBloc Spray Polyurethane Insulation & Dampproofing Note: Apply InsulBloc Spray Polyurethane Insulation in accordance with the appropriate NCFI Polyurethanes Technical Data Sheet. System Dwg. # 1-01 11-25-05

SPRAY-APPLIED POLYURETHANE FOAM INSULATION BRICK BRICK LIMIT OF HORIZONTAL MASONRY REINFORCEMENT LIMIT OF HORIZONTAL MASONRY REINFORCEMENT CONTROL JOINT CONFIGURED AS SPECIFIED BY OTHERS Wall Control Joint Dwg. # 1-02 1-26-07

MASONRY ANCHORS (TYPICAL) STEEL COLUMN SPRAY-APPLIED POLYURETHANE FOAM INSULATION Wall Column Joint Dwg. # 1-03 1-26-07

MASONRY ANCHORS SPRAY-APPLIED POLYURETHANE FOAM INSULATION BRICK FACING CONTINUOUS THRU- WALL FLASHING w/ WEEP VENTS MORTAR FILL Wall Section at Footer Dwg. # 1-04 1-26-07

MASONRY ANCHORS SPRAY-APPLIED POLYURETHANE FOAM INSULATION BRICK FACING CONTINUOUS THRU- WALL, PEEL and STICK FLASHING w/ WEEP VENTS MORTAR FILL Wall Section at Footer Dwg. # 1-04A 3-04-07

ROOF SYSTEM GYPSUM BOARD OR OTHER APPROVED THERMAL BARRIER BRICK FACING SPRAY-APPLIED POLYURETHANE FOAM INSULATION Wall Section at Roof Dwg. # 1-05 1-26-07

P O L Y U R E T H A N E S Masonry Wall Insulation Masonry Wall with Metal Studs (Typical) Dwg. # 1-06 1-2-08